“`html
Product Information
Specifications:
-
Model: VT-81014
-
SKU: 23430
-
HF System: 24Ghz CW Radar, ISM Band
-
Input Voltage: AC: 110-240V, 50/60 Hz
-
Rated Load: Max. 2000W (220-240V/AC), 1000W
(110-130V/AC), 1000W (220-240V/AC), 500W (110-130V/AC) -
Time Delay Detection Range: +LED
-
Compatible with: V-TAC LED (Range up to
1000W)
Product Usage Instructions
Installation:
-
Ensure the power supply is turned off before installation.
-
Mount the Real Presence Sensor in a suitable location with a
clear view of the area to be monitored. -
Connect the sensor to the compatible V-TAC LED lights according
to the provided wiring diagram. -
Power on the circuit and test the sensor by moving within its
detection range.
Operation:
The Real Presence Sensor detects motion within its specified
range and automatically controls the connected V-TAC LED lights.
When motion is detected, the lights will turn on, and they will
turn off after a set time delay once motion ceases.
Maintenance:
Regularly clean the sensor lens to ensure optimal detection
performance. Check for any loose connections and secure them if
necessary. Replace any damaged components promptly to avoid
malfunctions.
Frequently Asked Questions (FAQ)
Q: How can I adjust the detection range of the Real Presence
Sensor?
A: The detection range of the sensor can typically be adjusted
using the provided sensitivity settings. Refer to the user manual
for specific instructions on adjusting the detection range.
Q: Can the Real Presence Sensor work in extreme
temperatures?
A: The Real Presence Sensor is designed to operate within a
specified temperature range. Avoid exposing it to temperatures
outside this range to ensure proper functionality.
“`
INSTRUCTION MANUAL
REAL PRESENCE SENSOR
TECHNICAL DATA
MODEL
VT-81014
SKU
23430
HF SYSTEM
24Ghz CW Radar, ISM Band
INPUT VOLTAGE
RATED LOAD
TIME DELAY DETECTION RANGE DETECTION DISTANCE WORKING TEMPERATURE AMBIENT
LIGHT
AC: 110-240V, 50/60 Hz
Max. 2000W (220-240V/AC) 1000W (110-130V/AC) 1000W (220-240V/AC) 500W
(110-130V/AC)
Min. 10sec ±3sec Max. 12min ±1min
+LED
360°
COMPATIBLE WITH
V-TAC LED
RANGE (UPTO 1000W)
3m (radius) -20°C to +40°C <3-2000 LUX (Adjustable)
INSTALLATION HEIGHT
IP RATING
DIMENSION
2-4m
IP20 ØXXxXX mm
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the
best. Please read these instructions carefully before starting the
installation and keep this manual handy for future reference. If you have any
another query, please contact our dealer or local vendor from whom you have
purchased the product. They are trained and ready to serve you at the best.
The warranty is valid for 5 years from the date of purchase. The warranty does
not apply to damage caused by incorrect installation or abnormal wear and
tear. The company gives no warranty against damage to any surface due to
incorrect removal and installation of the product.
Caution, risk of electric shock.
This marking indicates that this product should not be disposed of with other household wastes.
MULTI-LANGUAGE MANUAL QR CODE Please scan the QR code to access the manual in
multiple languages.
In case of any query/issue with the product, please reach out to us at:
support@v-tac.eu For More products range, inquiry please contact our
distributor or nearest dealers. V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000,
bul.L.Karavelow 9B
WARNING
1. Please make sure to turn off the power before starting the installation.
2. Installation must be performed by a qualified electrician. 3. For indoor
use only.
FUNCTION
1. Can identify day and night: It can work in the daytime and at night when
it is adjusted on the “sun” position (max). It can work in the ambient light
less than 3LUX when it is adjusted on the “3” position (min). As for the
adjustment pattern, please refer to the testing pattern.
2. When the detection distance is less than 3M, it detects human breathing
and keeps lamp 3. on continuously. 4. When the detection distance is 3-4.5M,
it will be worked as a normal microwave sensor and
detects human movement automatically. 5. Time-Delay is added continually: When
it receives the second induction signals within the first
induction, it will restart to time from the moment. 6. TimeDelay is
adjustable. It can be set according to the consumer’s desire. The minimum time
is 10sec±3sec. The maximum is 12min±1min.
SENSOR INFORMATION
INSTALLATION
· Please move the upper cover with anti-clockwise whirl as per the diagram on
the right.
· Connect the power and the load according to the connection-wire diagram.
· Fix the bottom on the selected position with the inflated screw.
· Install back the upper cover on the sensor, then you could switch on the
power and test it.
WIRING DIAGRAM
The wires come in and out from the bottom
The wires come in and out from the side
TEST
1. Turn the TIME knob anti-clockwise on the minimum (10s).Turn the LUX knob
clockwise on the maximum (sun).
2. When you switch on the power, the light will be on at once. And 10sec±3sec
later the light will be off automatically. Then if the sensor receives
induction signal again, it can work normally.
3. When the detection distance is less than 3M, it can detects human
breathing and keeps lamp on continuously. When the detection distance is more
than 3m and then the lamp will be off after the setted time if there is no
another movement.
4. When the detection distance is 3-4.5M, it will be worked as a normal
microwave sensor and detects human movement automatically.
5. When the sensor receives the second induction signals within the first
induction, it will restart to time from the moment.
6. Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is
less than 3LUX (darkness), the inductor load could work when it receives
induction signal.
Note: When testing in daylight, please turn LUX knob to (SUN) position,
otherwise the sensor could not work!
NOTES
· Electrician or experienced human can install it. · Can not be installed on
the uneven and shaky surface. · In front of the sensor there shouldn’t be
obstructive object affecting detection. · Avoid installing it near the metal
and glass which may affect the sensor. · For your safety, please don’t open
the case if you find hitch after installation.
TROUBLESHOOTING
· The load don’t work a. Check the power and the load. b. Whether the
indicator light is turned on after sensing? If yes, please check load. c. If
the indicator light does not turn on after sensing, please check if the
working light corresponds to the ambient light. d. Please check if the working
voltage corresponds to the power source. · The sensitivity is poor a. Please
check the ambient temperature. b. Please check if the signals source is in the
detection fields. c. Please check the installation height. · The sensor can’t
shut automatically the load a. If there are continual signals in the detection
fields. b. If the time delay is set to the longest. c. If the power
corresponds to the instruction.