ideal HEATING 232630 Link Cellular User Guide
- September 2, 2024
- ideal HEATING
Table of Contents
ideal HEATING 232630 Link Cellular
Product Information
Specifications
- Model: 230787
- Connection: 2G cellular or NB-IoT
- App: Link Pro
- Warranty: 2-year Ideal Guarantee
Product Usage Instructions
Welcome
To begin, scan the QR code to download the Link Pro app. Follow the in-app
instructions after completing section 3.
Overview
- POWER LED
- BLUETOOTH LED
- CONNECTIVITY LED
Installing the Link Cellular
- Isolate the mains supply to the boiler.
- Locate and remove the blanking plate on the front of the boiler.
- Remove the link wire plug and keep it safe.
- Connect the plug on the Link Cellular to the connector in the aperture.
- Push fit the Link Cellular into the boiler aperture.
- Switch on the boiler, wait for boot-up. Power LED will be solid, Bluetooth, and Connectivity LEDs will flash. Follow app instructions.
LED Key & Troubleshooting
LED | STATUS |
---|---|
Power | – |
Bluetooth | Pairing times out: Press and hold pairing button for 5 seconds |
to re-enter pairing mode.
Connectivity| Unable to connect to Cellular network: Use external mounting
bracket for better connection. Factory reset: LEDs extinguish and
unit reboots.
Warranty
Ideal Link Cellular comes with a 2-year Ideal Guarantee. For full terms,
visit idealheating.com.
FAQ
-
Where can I download the latest specifications and maintenance practices?
You can visit idealheating.com to download relevant information in PDF format. -
What should I do if I can’t connect to the cellular network?
If unable to connect, consider using an external mounting bracket for a better connection. -
How do I reset the Link Cellular?
To reset, let the LEDs extinguish, and the unit will reboot automatically.
For the very latest copy of literature for specification and maintenance practices visit our website idealheating.com where you can download the relevant information in PDF format
WELCOME
To begin scan the QR code to download the Link Pro app. Follow the in-app instructions once section 3 is complete.
- This module will connect, via the Link Pro app, through a 2G cellular or NB-IoT connection, to the secure Ideal Heating Cloud.
- Once connected to the Ideal Heating Cloud this module will communicate diagnostic and telemetry boiler data to Ideal Heating and the housing provider to assist with service, maintenance, and fault diagnosis
OVERVIEW
INSTALLING THE LINK CELLULAR
- Isolate the mains supply to the boiler.
- Locate the blanking plate on the front of the boiler and carefully remove with a small flat bladed screwdriver.
- Remove the link wire plug and keep in a safe place
- Connect the plug on the Link Cellular to the connector in the aperture.
- Push fit the Link Cellular into the boiler aperture.
- Switch on the boiler, the Link Cellular unit will now boot up. Once this has been completed, the Power LED will be solid and both the Bluetooth and Connectivity LED’s will be flashing as shown. At this point follow the instructions in the mobile App.
LED KEY & TROUBLESHOOTING
LED | STATUS |
---|---|
Power | Green – Power ON |
No illumination – No power
Bluetooth| Blue (flashing) – Bluetooth/Cellular pairing mode active Blue –
Bluetooth connection to smart device active
Connectivity| Orange (flashing) – Searching/identifying cellular network Blue
– Successful connection to cellular network
Green – Successful connection to the Cloud Red – Failed to connect to cellular network Red (flashing) – No sim card/sim card error
Bluetooth pairing times out| Press and hold the pairing button for 5 seconds
to re-enter Bluetooth pairing mode
Unable to connect to Cellular network| If a connection to a cellular network
cannot be achieved, an external mounting bracket is available to facilitate a
better connection.
Factory reset of the Link Cellular| Press and hold the pairing button for 15
seconds – all LEDs will extinguish and the unit will reboot
WARRANTY
- Your Ideal Link Cellular comes complete with a 2-year Ideal Guarantee, for full terms and conditions please visit idealheating.com.
- Our Ideal Guarantee is offered in addition to the rights provided to a consumer by law. Details of these rights can be obtained from a Trading Standards Authority or a Citizens Advice Bureau.
Technical Training
Our Expert Academy offers a range of training options designed and delivered
by our experts in heating. For details please visit: expert-
academy.co.uk
Ideal Heating Ltd., pursues a policy of continuing improvement in the design
and performance of its products. The right is therefore reserved to vary
specifications without notice.
Hereby, Ideal Boilers LTD declares that this device (model 230787) is in
compliance with: Directive 2014/53/EU. The full text of the EU Declaration of
conformity is available at idealheating.com
Ideal Heating is a trademark of Ideal Boilers Ltd.
Registered Office Ideal Boilers Ltd., National Avenue, Hull, East Yorkshire,
HU5 4JB
Tel 01482 492251 Fax 01482 448858 Registration No. London 322 137
Ideal Technical Helpline: 01482 498663 Ideal Consumer Helpline: 01482 498660
Ideal Parts: 01482 498665
For more information and FAQs visit
idealheating.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>