ENGO Controls ETRV-M28 ETRV-M30 Thermostatic Radiator Valve User Guide

August 31, 2024
ENGO CONTROLS

ETRV-M28 ETRV-M30 Thermostatic Radiator Valve

“`html

Product Information

Specifications

  • Product Name: TRV Thermostatic Radiator
    Valve

  • Model: ETRV-M28 / ETRV-M30

  • Power Supply: 2xAA battery

  • Communication: Wireless with ZigBee compatible
    controllers (868 MHz + ZigBee)

  • Thread Size: M30 x 1.5 / M28 x 1.5

  • IP Protection Class: IP30

  • Dimensions: 50 x 81 mm

Product Usage Instructions

Installation

  1. Measure the thread diameter and pin height of the radiator
    valve.

  2. Choose the valve head based on the thread diameter (M30 or M28)
    and pin height (30mm for M30 or 28mm for M28).

  3. Remove the cover of the valve head.

  4. Insert the batteries with correct polarity.

  5. Reattach the cover.

  6. Wait for the LED to indicate the software version (e.g., v3.5
    flashes 3 times green and 5 times red).

  7. If installing on a Danfoss RA valve, use an M30 thread adapter
    and screw the valve head onto the radiator valve.

  8. To start the adaptation process, press the button once or wait
    for 3 minutes for automatic adaptation.

Synchronization with Head

An internet gateway is not mandatory for synchronization. Ensure
the head is installed and adapted to the valve insert. If connected
to a wireless control box or relay module, synchronization cannot
be activated.

FAQ (Frequently Asked Questions)

Q: What should I do if an adaptation error occurs during

installation?

A: If an adaptation error occurs with the valve insert, the LED
will flash alternately green/red every 3 seconds. Check if the
valve head is properly installed. You can retry the adaptation by
pressing the button once.

Q: Is an internet gateway required for synchronization with the

head?

A: An internet gateway is not mandatory for synchronization.
Ensure that the head is correctly installed and adapted to the
valve insert.

“`

TRV
Thermostatic Radiator Valve
ETRV-M28 / ETRV-M30 Quick Guide

Ver. 1.1 Release date: VII 2024
Soft: v3.5
Producer: Engo Controls sp z o.o. sp. k.
Rolna 4 St. 43-262 Kobielice
Poland

www.engocontrols.com

Technical specifications

Power supply Communication
Thread size

2xAA battery
Wireless with ZigBee compatibile controllers (868 MHz + ZigBee)
M30 x 1.5 / M28 x 1.5

IP Protection class

IP30

Dimension [mm]

50 x 81

Introduction
The wireless valve head is used for controlling radiator heating. It is an excellent replacement for a traditional manual thermostatic valve head. For it to function properly, pairing with a master controller is necessary. Up to six wireless valve heads can be paired with a single controller within the same room. Two-way communication between the devices occurs every few minutes via radio signals. Based on the collected data, the controller modulates the valve head’s opening. The temperature measured by the controller ensures even heating throughout the entire room. By using an internet gateway, the set (valve head + controller) can be controlled via the ENGO Smart application.
Product features
Wireless communication with the master controller
Automatic calibration
Exceptionally quiet
plug&play
Product Compliance
This product complies with the following EU Directives: 2014/53/EU i 2011/65/EU.
Safety Information:
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Installation:
Installation must be performed by a qualified person with appropriate electrical qualifications, in accordance with the standards and regulations in force in a given country and in the EU. The manufacturer is not responsible for non-compliance with the instructions.
WARNING:
For the entire installation, there may be additional protection requirements, which the installer is responsible for (e.g., installation of an additional differential pressure overflow valve).

User interface
1 LED diode (indicates device status) 2 Function button

Instalation of radiator head

1

2

2

1

Compatibility with Radiator Valves
PEASE NOTE: If there are discrepancies in dimensions, please contact us or the installer to consider replacing the valves to ensure compatibility with the valve head.

20

1

30

2

10 mm

20

10 mm

Measure the thread diameter. Measure the pin height.

Choose the valve head according to The pin height should be

the valve size: For a thread diameter between 10-15mm in the

of 30mm (M30) or 28mm (M28).

open position.

3 1
2

Remove the cover as shown in the
illustration.
4

Insert the batteries according to the correct polarity.
5

Reattach the cover as shown in the illustration.
6

The LED will indicate the software version (e.g., v3.5 flashes 3 times green and 5 times red).

Wait until the LED light is continuously green.

The installation on a Danfoss RA valve

When installing the valve head on

a Danfoss RA valve (see diagram

nearby), you must use an M30

thread adapter.
7

Screw the valve head onto the radiator valve.
INFORMATION:
If installing the valve head on a Danfoss RA valve, please contact customer support.
ATTENTION:

1x
To start the adaptation process press the button once once or wait 3 minutes, then the adaptation will start automatically. When the adaptation is correct – the LED will turn off.

If an adaptation error occurs with the valve insert, the LED will flash alternately green/red every 3 seconds. Check if the valve head is properly installed. You can immediately retry the adaptation by pressing the button once.

Synchronization with head

An internet gateway is not mandatory to synchronize thermostat with head. Make sure head is installed and adapted to valve insert (see head manual). If thermostat is connected to a wireless control box or relay module, synchronization with head cannot be activated.

1

2

3s
After successful adaptation process, press&hold head button for 3 seconds.
The LED will start flashing blue. 3

5 sec.

5 sec.

Hold simultaneously ­ and + buttons on

thermostat until the “SY” function appears.

4

Release buttons, SYNC function will be active (synchronization with head).
5

After successful synchronization, LED diode will indicate blue light for 10 seconds.
6

Thermostat will indicate how many heads are synchronized. 7
The devices are synchronized and ready to work.

,,END” message will appear after successful synchronization.
ATTENTION:
The synchronization should be performed for each head separately. One thermostat can control up to 6 heads within one room.

LED diode flashes green a few times, then red

LED diode indications – explanation
Turning on the power (inserting the battery into the head) – the LED indicates the software version (e.g. v3.5 flashes 3x green and 5x red).

LED diode flashes slowly on green …
LED diode lights up green

After inserting the batteries and indicating the software version, the head opens.The head is open and prepared for adaptation with a valve insert.

LED diode flashes quickly on green …
LED diode flashes slowly
on red 10x
LED diode flashes slowly on blue ..
LED diode lights up blue 10 seconds
LED diode lights up green 3 seconds
LED diode lights up red 3 seconds
LED diode flashes quickly on red …

Adaptation of the head with a valve insert.
The head is adapted with a valve insert, but is not paired with the thermostat. After clicking the button 1x, the LED will flash red slowly 10x.
The head is in synchronization mode with the controller. To enter the head-to- regulator pairing mode, press and hold the button until the LED starts flashing blue,
then release the button.
After synchronizing the head with the controller, the LED in the head will light up for 10 seconds.
When you want to check the opening/closing status of the head paired with the regulator. After pressing the button once – when the head is open, the LED lights up green for 3 seconds.
When you want to check the opening/closing status of the head paired with the regulator. After pressing the button once – when the head is closed, the LED lights up red for 3 seconds.
After holding the button for 10 seconds, the LED will flash red, then release the button. The head will be restored to factory values and the connection with the regulator will be removed. After the factory reset, the head restarts indicating the software version and is prepared for adaptation with the valve insert.

LED diode flashes on blue 2x The head lost communication with the regulator. If the head does not receive a signal from the regulator, it

every 10 seconds

flashes blue for 7 days and then turns off. If the head receives a signal from the regulator, the head returns

… 10 sec… …

to normal operation and the blue flashing stops.

LED diode flashes on red 3x every 10 seconds … 10 sec… …
LED diode flashes alternately on green/red
every 3 seconds … 3 sec… …
LED diode flashes alternately on green/red/
blue …
LED diode flashes on pink ..

Batteries are almost exhausted – they need to be replaced.
Adaptation error with valve insert, after correctly mounting the head on the valve insert, the adaptation can be repeated immediately by clicking the button once.
A hardware error.
Software update in progress.

Factory Reset

To RESET the head to factory settings, hold the button until the LED flashes red, then release the button. The head

will restart, restore factory default values and the connection with the regulator will be removed. The head must be

re-adapted with the valve insert.

10s

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENGO CONTROLS User Manuals

Related Manuals