“`html

Specifications:

  • Product Model: M-1705
  • Battery Requirement: Four AA Size 1.5V Battery
  • Code Length: 8-15 digits
  • Emergency Power Supply: 9V battery (for emergency use)

Product Usage Instructions:

1. Unlocking and Locking:

To unlock, input the user code (default: 12345678) and press OK.
To lock, turn the handle to the lock position.

2. How to Set Code:

To change the user code, follow these steps:

  1. Input factory default user code 12345678 + C
  2. Input new user code + OK + new user code + OK

Buzzer will give a long di sound to indicate successful code
change.

3. Auto-Alarm:

An auto-alarm will be activated if the wrong code is input 4
times or if there is violent destruct or improper movement. The
lock will be disabled for 60 seconds. Inputting the correct code
will release the alarm.

4. Automatic Power Shortage Prompts:

When the voltage is low, the buzzer will give a di di di sound
when unlocking, and the Low voltage indicator light will be on.
Please replace the batteries.

5. Emergency Power Supply:

If the lock cannot be opened due to low voltage, connect a 9V
battery to the Emergency power supply interface on the control
panel to open the lock. After opening the door, replace with 4pcs
AAA batteries.

6. Decode:

If the code is forgotten, provide the code on the lock body to
the distributor to decode. The lock will be reset to default with
management code: 87654321 and user code: 12345678.

Frequently Asked Questions (FAQ):

Q: What should I do if the lock does not open after entering

the correct code?

A: If there is no sound when operating the
keypad and the lock is okay to open, it may indicate a broken
buzzer. Refer to section 8 for solutions.

Q: How do I replace batteries in the lock?

A: Use four AA Size 1.5V batteries. Refer to
section 9 for installation instructions.

“`

LOCKS

8.Common problems & solutions

Problems
After code input,”di di di”sound alarm, lock not able to open

Primary cause Wrong code

Correct code input, “di di di’ sound alarm, and lock not able to open

is on,

Low voltage

No sound when operating keypad, lock is ok to open Buzzer broken

9.Installation instruction 3-5

Fixing hole size

15

Unit:mm

534-+07.0.53 20

M-1705
Solution Refer 7 Replace batteries Replace buzzer
25

25

7.7 5
15

5 74

68.4 45

35

19.3

13.25

234.45°

76.5 106.5

2 10

149

6

1

Use four AA Size 1.5V Battery

Installation step,see figure 2
Before installation, please make sure the handle and lock body are at unlock position, ( lock pin and cam contracted, factory default ) For metal furniture, suitable thickness: 1mm
2
Add : Guanhaiwei Industrial Zone West Section,Cixi,Zhejiang,China Tel : 0574-63631987 Fax0574-63630233 http : //www.wang-tong.com
4

Work Manual
M-1705
NINGBO WANGTONG LOCKS CO.,LTD.

LOCKS
Product Instruction

M-1705

Control panel

Low voltage indicator light

Unlocking indicator light

Emergency power supply interface

Use four AA Size 1.5V Battery

Lock body
RESET

Handle

Touch panel

Reset Battery box

Cam Locking pin

How to operate
1.Unlock
Input factory default code”12345678+ OK” ,Buzzer gives out a long di… sound,The unlocking indicator light is on, turn the handle 90°clockwise to open the lock
12345678

2.Lock
Rotate back the handle 90°to lock position

Turn the handle
Unlock position

OK 2

Lock position Turn the handle

LOCKS
3.How to set code

M-1705

Code can be consisted of 8-15 digits,last code will not be lost after changing the battery. Change user code: Input factory default user code 12345678 + C Input new user code + OK + new user code + OK
Buzzer gives out a long di sound means user code already been changed

4.Auto-alarm

…… OK
Auto-alarm will be activated if wrong code be input 4 times or violent destruct or improper move , the lock will be died for 60 seconds. Inputting correct code will release the alarm.

5.Automatic power shortage prompts

When the voltage is very low, buzzer gives out a di di di sound when unlock and Low voltage indicator light is on, please replace the battery

6.Emergency power supply

Emergency power supply interface

When the lock can’t be opened due to the low voltage, pls
connect a 9V battery to the Emergency power supply interface on the control panel to open the lock. It is for emergency, after open the door, please equipped
with 4pcs AAA

7.Decode

When code been forgotten, you can get the decode number by providing the code on the lock body

to the distributor to decode. the lock will be changed back to defaults

management code: 87654321 user code: 12345678

3