AIRTEK AC-Dual 20 Fully Automatic Machine User Manual

August 30, 2024
AIRTEK

AC-Dual 20
Operation Manual
For new customer training

Machine Introduction

  1. Graphic Display and Keypad
  2. Thermal Printer
  3.  Low-side (blue) and High-side (red) Manifold Gauges
  4.  HFO1234yf Tank Gauge
  5. Non-condensable Air Purge Valve for 1234yf Tank
  6. New Oil Bottle
  7. Used Oil Bottle
  8. Plate with Serial number and Machine model
  9. Wheel Lock
  10. Low-side (blue) and High-side (red) Service Hoses
  11. R134a and HFO1234yf refrigerant Tanks
  12. Storage
  13.  R134a Tank Gauge
  14. Non-condensable Air Purge Valve for R134a Tank
  15.  Power Switch
  16.  Power Cord
  17.  R134a and HFO1234yf HP/LP Couplers Parking Connectors
  18.  134a and HFO1234yf HP/LP Couplers
  19. Service Hoses Connection Fittings
  20.  LCD Display
  21. Up Arrow (Number Added)
  22.  Right Arrow (Quantity Added and Solenoid On)
  23.  Exit Button
  24. Left Arrow (Quantity Reduced and Solenoid Off)
  25.  Down Arrow (Number Reduced)
  26. Enter Button

AIRTEK AC Dual 20 Fully Automatic Machine - Machine
Introduction Set Up the machine

AIRTEK AC Dual 20 Fully Automatic Machine - Machine
Introduction1

Unlock Scales

AIRTEK AC Dual 20 Fully Automatic Machine - Unlock
Scales

Remove the two lock bolts to release two scales and make them to accurately measure the weight of the refrigerant tanks.
Warning:

  1. Failure to remove the scale lock bolts may cause wrong refrigerant processing amount.
  2. When you need transport the machine, please screw those bolts on to lock the scales.

Turn on the machine and select refrigerant type

Each time the machine is turned on, it reminds to select refrigerant type. If the refrigerant type selected is different from the refrigerant handled at previous operation (our new machine is default 134a refrigerant), the machine requires you to replace HP/LP couplers to the selected refrigerant couplers, then process 10 minutes evacuation.

Notes:

  1. Be sure you select same refrigerant type as what the vehicle contains, or serious contamination in machine tanks will be caused.
  2. Anytime you desire to shift from the refrigerant which machine currently handles to another, turn the machine off and turn it on again, and then select the refrigerant type.
  3. Do not connect any external refrigerant tanks or vehicles until the machine has completed switching the refrigerant system.
  4. Make the HP/LP hoses clean off refrigerant (based on HP/LP gauges pressure) before switching to different refrigerant. Otherwise, it will take longer to purge the remaining refrigerant in the hoses to used oil bottle.

Prepare to use the machine

AIRTEK AC Dual 20 Fully Automatic Machine - Prepare

System Setting

AIRTEK AC Dual 20 Fully Automatic Machine - System
Setting

Tank fill

New machine is empty, so you need to fill the machine with refrigerant.

  1. Connect the red and blue HP/LP service hoses tightly to the machine’s side hose flush fitting ports.

  2. Use the brass fitting adapters to securely connect the external tank to the LP coupler. Then, open the valves of the external tank and the LP coupler, ensuring that the blue LP gauge on the machine displays a certain pressure.

  3. Upside down the external tank.
    Note: Leave the HP coupler closed or disconnected with parking connector

  4. Enter the tank fill interface, set the quantity of refrigerant you want to add to the machine’s refrigerant tank (the machine defaults to 8.8 lbs), then click “Enter.” The machine will begin the recovery process.
    Note:
    Our machine’s refrigerant tank has a minimum set quantity of 4 lbs and a maximum of 22 lbs. If it falls below 4 lbs, it cannot recharge, and if it exceeds 22 lbs, it cannot recover.
    Therefore, we recommend not exceeding 15 lbs to ensure there is some space for recovery.

  5. When there is approximately 2 lbs left to reach the set quantity of refrigerant, the machine will stop the recovery process. It will prompt you to close the valve of the external tank. Then, it will continue to recover the remaining refrigerant from the hoses until the recovery process is automatically completed.
    Note:
    Forgetting to close the valve of the R134a external tank as prompted by the machine can result in an excessive amount of refrigerant being added to the machine’s refrigerant tank, which may affect the machine’s normal operation.

Fill PAG oil to new oil bottle

For the AC-Dual 20, only install a new oil bottle, and it can only inject PAG oil that most regular cars can use (the most common type is PAG 46, although some cars may require higher-density PAG).

AIRTEK AC Dual 20 Fully Automatic Machine - Fill PAG
oil

For hybrid or electric vehicles, which require POE oil, this machine cannot be used for oil injection. You must prepare a manual injector to inject POE oil.

Operating the machine

AIRTEK AC Dual 20 Fully Automatic Machine - Fill PAG
oil2

Manual Operations

AIRTEK AC Dual 20 Fully Automatic Machine - Recovery

Automatic Mode Operation

  • We recommend selecting auto mode for charging the vehicle with refrigerant, as it provides better results and cost savings.

  • Enter auto mode and select “Normal charging” or “High voltage charging”. If it’s high voltage charging for hybrid or electric vehicles, hose flush must be performed to clear any remaining oil residue in all hoses to avoid oil contamination. If it’s Normal charging, hose flush is an optional step.

  • Pre-set the duration for vacuum and leak test, the amount for oil injection and refrigerant charging, as well as the method of refrigerant charging (HP, LP, or HP-LP). The machine will automatically perform recovery, vacuum, leak test, oil injection, and refrigerant charging in sequence according to these settings.