Product Introduction

XGPON/10GEPON power meter is a new tester for FTTX network. It has all the functions of traditional PON tester. Besides, it also has the function of the next generation PON testers. JW3239 could judge whether the power value is suitable or not by self-setting the threshold. It is an ideal tester for PON network and maintenance.

Technical Specifications

Baudcom-BD-PON-J310G-XGPON-fig-16

Function Description

Appearance

Baudcom-BD-PON-J310G-XGPON-fig-1

  1. OLT/Video Downstream detector(1490nm/1550nm/1577 nm)
  2. ONT Upstream detector(1310nm/1270nm)
  3. Screen
  4. Turn on/off
  5. Cursor selection
  6. Function selection
  7. Menu/ Unit
  8. Relative value
  9. Cursor selection
  10. Confirm key
  11. Setting key
  12. Menu/ Wavelength
  13. USB Communication port

Operation Instruction

Power ON/OFF

Power ON

  1. You should confirm the appearance of the product.Ensure the correct installation of the battery.
  2. Press the key until the screen is light,The backlight of product will be dim if there is no operation in 60 seconds.(You can set the brightness by yourself in Menu) If there is no button operation for more than the set time, the meter will automatically turn off.

Power OFF

  1. Press key for about two seconds, to turn off the unit.
  2. When the set time of auto-off is not 0 second,the product will be auto off if there is no operation in the set time. You can press the key to turn off the function, and the icon will become gray

Interface of PON Network Power
This is PON power meter module. You can see the interface through press “Function selection keys” or “Menu” back to the interface.

Instructions for Normal Optical Power Meter Function
After open the instrument, switch to the Normal optical power Meter Module. Clean the tested optic cable, connect with instrument. The optical adaptor will be break, and the tested value will be faulty if the un-matched adaptor connected If the power within the measuring ranger of instrument, the screen can show the correct measurements. If you want to save the data ,Please press ”Confirm” key

In this interface, you can update reference value through press ”Ref” key, and the reference value will be displayed on the screen. The unit of reference value is ”dB”. If you want to view reference value records press “Up” key until you can see the “reference value”;

Edit PON Threshold
In the interface of threshold selection , You can set the threshold group , the name and the threshold parameter corresponding to the channel In this interface, press the direction keys to set the selected object, press the “Enter” key to enter edit mode, it can be edited by direction keys, press “Enter” key to save

Baudcom-BD-PON-J310G-XGPON-fig-5

Press “Menu” key to back after finish edit. Pop-up dialog If you do not need to save, you can directly press the return menu item to exit to the main menu。

Record
History data record to delete and view datum function.press direction keys to choose different function and press “Enter” key to execute the function. without any operation after enter the interface, the upper right corner of the display is always the number of the last record, it also means the used RAM

Settings

The Interface of instrument setting can set “the instrument time”, “the backlight brightness” “waiting time of auto-off instrument”, “language setting”. The instrument supports 3 kinds of language, Chinese, English and Spanish. In this interface you can press direction key to select, and press “Enter” key to enter edit mode

Connection and Information

Connection and information interface include “ROM Version” “Release Time”“ Capacity”“Connection”You need switch to this interface when connecting the test software ,The “Connection” shows “YES” represent connection successfully

Test software instruction
Run the CD, install USB driver software CP210x_VCP_Win2K_XP_S2K3.exe。

Install the software dotNetFx40_Full_x86_x64.exe。

Connect PON power meter to the computer’s port using the provided USB cable, Open the software

Upload the data (Note: customer software and instrument cannot be operated at the same time)

  1. Open the PON power meter,first of all click “connect”,connect PON power meter to the computer(Click“English”to set the language of the operation interface to be English )
  2. choose “Upload Data”,click “Upload Test Data”sign,the saved data can be read on the computer, and saved as a file format.
  3. click the“Delete Test Data” button or“Clear Test Data”to delete the data.

Baudcom-BD-PON-J310G-XGPON-fig-13

Click “Upload threshold value” icon to read the threshold. From the toolbar, select “Threshold Set”, and right click the Threshold to type or modify the threshold value

Baudcom-BD-PON-J310G-XGPON-fig-14

Calibration
Choose “Calibration” tab, the user can perform user self-calibration operation also can choose “Factory Reset” mode. For example, the current optical power at 1310nm is -10dBm, type -10dBm in the text box of input standard power, and click Calibration tab, then finished the calibration operation at 1310nm wavelength

Baudcom-BD-PON-J310G-XGPON-fig-15

Maintenance

  1. The tester should work without obvious vibration.
  2. Always keep clean fiber-optic connectors before using, keep the unit free from oil and dust.If there is dirt, unscrew the adapter and use wipes or paper and anhydrous alcohol to clean the end face
  3. After finish the testing or when the unit is unused, please cover the dust-proof cap to ensure the optical interface is clean and to avoid measurements errors caused by dust.
  4. Push/pull the fiber-optic connectors carefully to avoid the scratches on the interface.
  5. Handle with care to prevent equipment from falling and collision

Troubleshooting

Baudcom-BD-PON-J310G-XGPON-fig-18

Quality Insurance

Caution : Repair it in the field is NOT recommended.

  1. We warrants that PON Optical Power Meter will be free from defects in material and workmanship for a period of 18 months. The date will be started from the date of goods receiving by original customer.
  2. This warranty is limited to defects in workmanship and materials and does not cover damages from accident, acts of god, neglect, wrong usage or abnormal conditions of operation.
  3. We will charge corresponding fees for the cost of materials, repair and shipping in conditions of below: Defects occurred under normal use and service but out of the warranty period. Failures and damages occurred do not because of defects in material and workmanship of products. Failures and damages occurred because of failing to comply with the Operation Instruction and necessary attention. abnormal conditions of operation or handling: Such as artificial damage, or operating in abnormal conditions of like high temperature high voltage, humidity and etc., we will charge depend on the actual failure rating

Order Information : XGPON/10GEPON Power Meter

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals