Overview

BD-24TUNER-IP is a professional high integration device which includes tuner demodulation, multiplexing, and modulation. It supports 4/8/12/16/20/24 tuner input(support different types of tuner ( DVB-S2、DVB-C、DVB-T、 ATSC、 DTMBT、ISDBT, etc. ) input), 1000M IP output, 4 MPTS output and 512 SPTS output。In conclusion, its high integrated and cost-effective design makes the device widely used in varieties of digital distribution systems such as cable TV digital head-end, digital TV broadcasting etc.

Key Features

  • 4/8/12/16/20/24 tuner input; the tuner supports (DVB-S2/DVB-C/DVB-T/ATSC/ISDBT/DTMBT)
  •  1000M IP output over UDP and RTP protocol (MPTS and SPTS)
  • Support different types of tuner ( DVB-S2、DVB-C、DVB-T、 ATSC、 DTMBT,、ISDBT, etc. ) input, or mixed use ( e.g., 4 -way dvb – t and 4 – way ATSC input at the same time, making up 8 – way input )
  •  2 ASI inputs
  •  2 ASI Independent output (optional) as copy of 1MPTS
  •  Support “Null PKT Filter” function
  • Support PID Remapping/ PCR accurate adjusting
  •  PID pass
  • LCD、key function
  • Control via web management, and easy updates via web

Technical Specification

input| 4/8/12/16/20/24 tuner; and the tuner supports

( DVB-S2/DVB-C/DVB-T/ATSC/ISDBT/DMBT )

---|---
2 ASI inputs
output| 2 ASI output
IP output(512 SPTS and 4 MPTS)IP output over UDP and RTP

protocol

Multiplexing| Maximum PID

Remapping

| 180 output PID per channel
Function| PID remapping (automatically or manually)
Accurate PCR adjusting
System function| Network management (WEB)
Chinese and English language
Ethernet software upgrade
Miscellaneo us| Dimension(

W×L×H)

| 550mm×515mm×140mm
weight| 6kg
Environment| 0~45℃(work);-20~80℃(storage)
Power requirements| AC100~240V,50/60Hz

Operating specification

The device is connected to the input signal, connected to the power supply, and the equipment is controlled through the browser after the equipment starts normally.
Front panel

Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-1

  1. LCD display
  2. Indicator light
  3.  Button
  4. ASI In
  5. ASI OUT
  6.  NMS, DATA input/output

Rear panel:

Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-2

  1. Tuner input
  2. Power switch
  3. Three-core power jack
  4. Grounding point

Connect the computer’s internet port to the device’s NMS network port, modify the computer’s IP address to a fixed IP: 192.168.0.100, open the Google browser, and enter 192.168.0.136 to log in to the device management interface.

  1. Enter the IP address of the device on the browse(default address:192.168.0.136)
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-3

  2. Username and password(default address:admin)

  3. Enter the Device->Status bar to clearly detect the running status of the device
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-5

  4. Tuner Parameter setting

    • Tuner Parameter,click Edit Set parameters

    • Click“ ”undown“ ”to“ ”( meaning that the input channel is  turned off and the unused input channel should be turned off )

  5. Program MuxBaudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-7

  6. Select the frequency setting port for Mux program
    Multiplex program step:

  7. select which frequency point to multiplex the program at

  8. Click Analyzing program information of the input channel,
    Or select any input port ( Such as tuner / ASI / IP),click Analyzing program information of the channel

  9. Select programs under any input port ,Tick the box

  10.  Click“ ”,Multiplexing programs into the selected frequency point list

  11.  IP input,by adding IP information

  12. Delete program step:

  13. Select which frequency point to multiplex the program at 。

  14. In the output window,Remove the box in front of the program name ,
    click“ ”,Cancel the reuse of programs

  15. In the output window, at frequency point, click the program nameand pop up the following window to modify the parameters of  the program
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-9

  16. TS Config parameters

  17. PID Pass parameters
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-10

  18. Output->Network, Network communication parameters of equipment
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-11

  19. Output->Mux IP Stream
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-12

  20. Output->ASI Output
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-13

  21. Equipment upgrade
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-14

  22. Save Menu
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-15

  23. Date/time, No operation, only test

  24. State information monitoring, No operation, only test
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-17

  25. After the device parameter is modified, it must be saved so as not to set the device parameter again after the power is off。
    Baudcom-BD-24Tuner-IP-Tuner-to-IP-ASI-Gateway-18

Website : www.baudcom.com.cn
Tel: +86 21 37709251
Email: info@baudcom.com.cn

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals