Baudcom High Power EDFA for FTTH and FTTB User Manual
- June 3, 2024
- Baudcom
Table of Contents
High Power EDFA for FTTH / FTTB
1550nm EDFA
(power supply:48VDC/110VAC/220VAC)
Operating Manual
High power amplifier
**Using Safety Precautions
**
Before installing and using this product, please read the following carefully.
The Company does not assume any responsibility for any loss due to security
breaches caused.
Lasers and erbium-doped fiber amplifier output power laser radiation is not
visible, can not look directly at the device connector end when it works to
avoid burning eyes and skin.
Equipment includes precision optics, in order to avoid damage to the severe
impact of its constitution, please avoid excessive vibration and impact.
Pigtail easily sacrificed, so be careful.
Equipment containing electrostatic sensitive devices, handle it carefully and
make sure the ground is good, the power supply is normal.
Attention of optic fiber end face:
-
Before using, please be sure to keep the input and output end face of the optic fiber clean, especially if the output end face is dirt, then it is easy to make the output end face burned and the output power will be decreasing. When cleaning the optical fiber end face or insert patch cords, please turn off the input light first.
-
The correct order of plugging optical port is:
Inserting: first insert optical patch cord of output port, then insert optical patch cord of input port.
Pulling out: first pull optical patch cord of input port, then pull optical patch cord of output port. -
This kind amplifier is a high precision and high stability product, in order to have high stability output power, please use optical patch cord with good quality and which connectors are match with the device to connect with the output port. In principle, the optical patch cord should be as short as possible, and do not let it voluntary movement.
If there are any questions, please contact our company. Do not disassemble the module, otherwise it will cause irreparable damage
Application
- Analog CATV Transmission
- FTTH Optical Access
- Optical Distribution
- Free Space Optical
- R&D and Training
Feature
- High Power:Up to 2W total,1 Unit for 2000~4000 optical node
- Low Noise Figure:Below 5.5dB ( +5dBm input)
- Er Yb co-doped DCF Amplify Technology:Patent Pump Dump Technology
- Low CSO: <-70dBc
- 23dBm×N,20dBm×N or 17dBm×N output is optional
- Controllability and maneuverability: Dual CPU to deal Control loop and Communication separately
- High Stability And Reliability:MTTF>150000 Hours
- Redundancy Hot Swap power module: 110/220VAC and 48VDC can plug Mix
- Perfect Network Interface:Ethernet
- Intelligent Temperature Control System: using a dedicated Temperature control chip which make cooling and power loss reduce 30% than competitors
- Integrated 1310nm,1490nm,1550nm WDM (Optional)
- OEM, Module is available
Description
The product is high output power C-Band Er-Yb co-doped double cladding optical
fiber amplifier.
The key components of the product are high reliability multimode PUMP laser
and the double cladding optical fiber. A proprietary ATC (Automatic
Temperature Control) and APC (Automatic Power Control) circuit insures the
high stability and reliability output power, the unique optical circuit design
ensures the excellent optical performance. The high stability and high
precision MPU system to ensure the control, adjustment and display are
intelligent and easy.
This amplifier employ double cladding Erbium Ytterbium co-doped fiber, and
employ the high power multimode pump, with a 10 times Conversion efficiency
higher than the single mode general technology, and therefore have a lower
relative cost and more compact size and lower power consumption, in
particular, for FTTH or FTTB or other large distribution system applications.
Employ intelligent temperature control system: (1)Adopt special temperature
control circuit,heat radiating and power consumption can be reduced 30%,
(2)The professional air flow design can also ensure the best temperature
stability, at the same time powerful fan will start when the case temperature
is over 45 , meanwhile it will stop as the temperature is under 40 .The
technology makes sure the thermal stability of system and fan’s long life.
Intelligent network management system. Perfectly network interface: Ethernet
network,and the open network management interface ensure the connectivity with
all other network management system.
These products are widely used in CATV transmission system and the high power
distributing system FTTH requirement. It can be used for CATV analog/digital
signal distribution, or match with PON system to construction the triple
network integration. (Triple wavelength WDM is optional)
Block Diagram
Optical characteristics
Parameter | Symbol | MIN | TYP | MAX | UNITS |
---|---|---|---|---|---|
Operating Wavelength | λc | 1540 | 1550 | 1565 | nm |
Saturated Output Power Note1 | Po | 13 | —— | 33 | dBm |
Input Power | Pi | 0:00:00 | —— | 10 | dBm |
Gain | G | —— | —— | 30 | dB |
Noise Figure Note2 | NF | —— | —— | 5.5 | dB |
Output Power Stability | ΔPo | —– | ±0.05 | ±0.2 | dB |
Input Isolator | ISOi | 30 | ——- | —— | dB |
Output Isolator | ISOo | 30 | ——- | —— | dB |
Input Pump Leakage | PLi | ——- | ——- | -35 | dBm |
Output Pump Leakage | PLo | ——- | ——- | -45 | dBm |
Return Loss | RL | ——- | ——- | -45 | dB |
Polarization Dependent Gain | PDG | —— | ——- | 0.3 | dB |
Polarization Mode Dispersion | PMD | —— | ——- | 0.5 | ps |
Note 1:Optional
Note 2:Tested at +5dBm Input
Environmental characteristics
Parameter | Symbol | MIN | TYP | MAX | UNITS |
---|---|---|---|---|---|
Operating Temperature | Tw | -5 | —– | 60 | ℃ |
Storage Temperature | Ts | -40 | —– | 80 | ℃ |
Humidity Note | —— | 10 | —— | 90 | % |
Note: No Condensate
Electrical Characteristics
Parameter | Symbol | MIN | TYP | MAX | UNITS |
---|---|---|---|---|---|
Power Supply(1) | Vps | 170 | 264 | VAC | |
Power consumption | P | —– | —– | 50 | W |
1: 110VAC,220VAC and -48VDC is optional, and duplicate supply is optional.
Starting up
Before starting up, Please check the input voltage to the rated input voltage,
grounding is good.
The product adopts independent 220 VAC power supply.
Equipment Powered Instructions
Special Note:
- The power module must be properly inserted in the device, so it can be supplied power.
- Do not insert the charged power module into the device directly.
LED/ Key Description
key : Upper button. Press this button can check each parameter of products
from bottom to top.
key : Down button. Press this button can check each parameter of products from
top to bottom.
key : Menu button. Press it can enter the menu.
key : Return button. Press it can return to the standby screen。
Display Menu Description
-
Display device start up process when power on:
High Power Amplifier -
Press the Menu button to display products model:
MODEL : EDFA 1550 -
Press the down button to display internal temperature:
INTERNAL TEMP **℃ -
Press the down button to display the current of pump 1:
LD1 CURRENT ***MA -
Press the down key to display the cooling current of pump 1:
TEC1 CURRENT ***MA -
Press the down button to display the current of pump 2:
LD2 CURRENT . A -
Press the down button to display the temperature of pump 2:
LD2 COOLER *. ℃ -
Press the down button to display the operating current of pump 3:
LD3 Current . A -
Press the down button to display the temperature of pump tube 3:
LD3 COOLER *.℃ -
Press the down button to display input optical power:
Input *.*mW .*dBm -
Press the down button to display output optical power:
OUTPUT MW .DBM -
Press the down button to display working status:
AGC Conerol ***
In this screen, press the Menu button to display “ON” opens AGC function . If a high-power pump is damage, the other pump will increase the pumping power automatically to maintain the stability of output power. Press the Return key to display “OFF”, this function is off. -
Press the down button to display the status of the pump:
PUMP CONTROL **
In this screen, press the Menu button to display “ON” pump working.
Press the Return key to display “OFF” pumped off.
Indicator
- Pump1: Pump 1 indicator off is normal, pump 1 flashing is alarming.
- Pump2: Pump 2 indicator off is normal, pump 2 flashing is alarming.
- Alarm: Alarm Indicator: input and output light turns red when alarming.
- AGC : When the AGC function is turned on the light turns green.
Interface
Front-Panel
|
Back-Panel
---|---
|
Connectors
| Description
---|---
Input| Optical input port
1~16| Optical output ports
RJ45| Ethernet control port
Power1/2| Power input 110/220V AC
Reset(optional)| Short press: reboot net control board
Long press: reset all net parameter to default
Order Information
Note 1: EDFA-1550 for 1U rack,Maxim ports number: 16(w/ WDM),or 32(w/o
WDM)
Note 2: High End configure with SNMP Net management.
Note 3: 2U and 3U rack maxim 64 port with WDM
Laser Safety Information
Class IV laser products.
9μm/125μm single-mode fiber pigtail with connector.
Wavelength=0.90~1.68μm
Maximum Power=10W
SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD
Website:http://www.baudcom.com.cn
http://www.e1-converter.com
Email:info@baudcom.com.cn
Tel: +86 21 37709251
Documents / Resources
|
Baudcom High Power EDFA for FTTH and
FTTB
[pdf] User Manual
High Power EDFA, High Power EDFA for FTTH and FTTB, High Power Amplifier,
Amplifier, 1550nm EDFA
---|---
References
- GPON ONU, Fiber Tools, FTTX total solution provider - Baudcom
- E1 converter,Fiber multiplexer,TDM over IP,SDH Multiplexer,Fiber media converter,SFP module,Baudcom
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>