Specifications
- Model: ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
- Version: 1
- Revision: 0
- Release Date: 4 April 2024
- Smart Management
- Efficient
- Safe & Reliable
Safety Instructions
Safety Guidelines
- Personal Safety
Follow personal safety guidelines to ensure safe operation of
the product.
- General Guideline
Refer to the general guidelines provided in the manual for
proper usage.
- Module Operation
Understand the module operation instructions before use.
- Module Operating Environment
Maintain the module in the recommended operating environment for
optimal performance.
- Module Cleaning
Regularly clean the module as per the cleaning instructions
provided.
- Storage Environment
Store the product in the specified environment to prevent
damage.
- Disposal
Follow proper disposal guidelines when the product is no longer
in use.
Pre-Installation
Before installing the product, ensure you have read and
understood all safety instructions and guidelines provided in the
manual. Follow these steps:
-
Check all components for any damage.
-
Prepare the installation area according to the
specifications. -
Refer to the installation instructions for proper setup.
-
Connect the product following the recommended procedures.
-
Test the product to ensure it is functioning correctly.
Frequently Asked Questions (FAQ)
Q: Can I install the product myself?
A: It is recommended to have the product installed by a
professional to ensure proper setup and safety.
Q: How often should I clean the module?
A: The module should be cleaned regularly as per the cleaning
instructions provided in the manual, typically every few months
depending on usage.
Q: What should I do if the product is not functioning
correctly?
A: If you encounter any issues with the product, refer to the
troubleshooting section of the manual or contact customer support
for assistance.
“`
USER MANUAL 1KWH-12V ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
VERSION 1 | REVISION 0 | RELEASE DATE: 4 April 2024
SMART MANAGEMENT
· Feature-rich Online Monitoring via ENCONTROL Tool · Automatic Firmware
Updates · Warning Alarms
EFFICIENT
· Highly Efficient: > 95% RTE (Round Trip Efficiency) · 100% DOD (Depth of
Discharge) · 500,000 Cell Life Cycles
SAFE & RELIABLE
· Wide Operating Temperature Range · Deployable in Various Environments
including High
Altitudes · No Thermal Runaway Risk
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
ATTENTION
No part of this User Manual (“Manual”) may be reproduced, or transmitted, in
any form or by any means, without the prior written permission of ENERCAP
POWER INDUSTRIES LLC (“ENERCAP” or the “Company”). Specifications in this
Manual are subject to change without notice. While every attempt has been made
to make the Manual accurate and up-to-date, users are cautioned that product
improvements may cause the Company to make changes to specifications without
advance notice. Users are encouraged to consult the Company or its Resellers
before using the Manual. Neither the Company nor its Resellers shall be liable
for any indirect, incidental, or consequential damages under any circumstances
caused by reliance on the material presented, including, but not limited to,
omissions, typographical errors, arithmetical errors or listing errors in the
content material. The content of this Manual shall not be modified without the
written authorization of the Company.
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 2/15
USER MANUAL
Document HISTORY
Issue 01 (2024-4-4) First release
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 3/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
Table of Contents
Document HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 3
SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SAFETY GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.Personal Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.General Guideline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.Module Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.Module Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.Module Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.Storage environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7.Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PRE-INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CONTENT CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
LOCATION REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.Area of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.Environment Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ELECTRICAL INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 4/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.MC4
Male Connector Fitting. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
ELECTRICAL SETUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 16 1.Connecting Module to Power Supply/Charger . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.Connecting Module
to Load/Discharger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . 17 3.Parallel Connection setup:. . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . 18
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 5/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
SAFETY INSTRUCTIONS
SAFETY GUIDELINES
1. PERSONAL SAFETY
Always wear proper personal protective equipment (eyes protection, gloves, and
safety shoes). 2. GENERAL GUIDELINE
Do not subject the Module to strong impact. Do not crush or puncture the
Module. Do not place the Module near a heat source, such as a fireplace. Do
not disassemble the Module under any circumstances. Ensure precautions to
prevent short-circuit under all circumstances. Do not touch the terminals with
conductors while the Module is charging. Serious burns, shock, or material
fusing may occur. Protect surrounding electrical components from incidental
contact. Do not subject the Module to high pressure. Do not place any object
on top of the Module. Do not drop the Module. Internal damage may occur that
will not be visible. Do not stack Modules once they have been removed from the
packaging. Instead the Modules should be placed on shelves.
This user manual is subject to change without notice and at the sole
discretion of ENERCAP www.enercap.energy
Page 6/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
In case the Module is physically damaged for any reason, do not install and
energize the Module under any circumstances and immediately contact your
Reseller.
3. MODULE OPERATION
Do not operate the Module above the specified voltage. Always make sure
charger is set as recommended. When connecting to external devices ensure that
galvanic isolation of the external device(s) does not exceed 1000V. Always
make sure chargers are disconnected while working on Modules. Do not connect
or disconnect terminals from the Module without first disconnecting the load.
4. MODULE OPERATING ENVIRONMENT
Location: Indoor/Outdoor Operating Temperature Range: -30oC to 70oC (For
continuous operations outside this range, please consult your Resellers or
Enercap). Operating Humidity: Non-Condensing Do not charge the Module when the
temperature is below -30oC. Do not charge the Module when temperature is above
70oC. 5. MODULE CLEANING
Disconnect the power before cleaning. Use a soft cloth dampened in a solution
of mild detergent and water.
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 7/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
6. STORAGE ENVIRONMENT Do not store the Module at temperature greater than
70oC. 7. DISPOSAL
Do not dispose the Module in fire. Do not dispose this Module as unsorted
municipal waste. Please use a separate collection facility or contact the
supplier from whom this Module
was purchased. Please make sure discarded electrical waste is properly
recycled per applicable regulations to reduce environmental impact.
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 8/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
PRE-INSTALLATION
INSPECTION
Document (e.g., photo) any damage and report this to your Reseller and
shipping agent immediately. Remove the Module from the shipping carton and
retain the shipping materials until the unit has been inspected and is
determined to be operational.
CONTENT CHECK
Check the contents of the package. The following are standard items shipped by
us.
1kWh-12V
Figure 1: Module package contents
MC4 Connector
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 9/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
LOCATION REQUIREMENTS
1. AREA OF INSTALLATION
Install the Module at an appropriate height for ease of viewing LCD and operating switches.
a
b
c
IP20
IP20
IP20 Shelter
Figure 2: Installation restriction: a) Module can be stored inside b) Modules
cannot be stored outside without shelter c) Modules can be installed indoors
and outdoors with shelter
2. ENVIRONMENT REQUIREMENTS
The ambient temperature and relative humidity must meet the following
requirements.
+70oC (+158oF)
-30oC (-22oF)
Non-Condensing
Figure 3: Operating temperatures and humidity of Module
This user manual is subject to change without notice and at the sole
discretion of ENERCAP www.enercap.energy
Page 10/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
ELECTRICAL INSTALLATION
ELECTRICAL CONNECTIONS
1. MC4 MALE CONNECTOR FITTING 1. Strip the wire shorter than the metal crimp
connector. There is a mark on the metal that indicates how far the other
connector will enter into this one.
If the cable extends past this mark in the connector, the MC4 connectors will not be able to join together.
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 11/15
USER MANUAL
2. Crimp the wire.
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
3. Pass the screw nut over the metal crimp.
This user manual is subject to change without notice and at the sole discretion of ENERCAP www.enercap.energy
Page 12/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
ELECTRICAL SETUP
1. CONNECTING MODULE TO POWER SUPPLY/CHARGER Connect positive and negative
terminals of charger to the positive and negative terminals of the Module,
respectively.
Recommended Settings:
Power Supply or Charger Voltage: 12Vdc Max. Charge Current: 20A Voltage Range:
10.8Vdc to 15Vdc
Figure 4: Charging Module with power supply
This user manual is subject to change without notice and at the sole
discretion of ENERCAP www.enercap.energy
Page 13/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
2. CONNECTING MODULE TO LOAD/DISCHARGER Connect positive and negative terminals of discharger to the positive and negative terminals of the Module, respectively.
Recommended Settings:
Discharger or Load Voltage: 12Vdc Max. Discharge Current: 20A Voltage Range:
10.8Vdc to 15Vdc
Figure 5: Discharging Module from discharger
This user manual is subject to change without notice and at the sole
discretion of ENERCAP www.enercap.energy
Page 14/15
USER MANUAL
ENL-1k-12-0.25C-X-X-X-X-1V0-GEN1
3. PARALLEL CONNECTION SETUP:
Any number of Modules can be connected in parallel. All Modules must be at
100% SOC before connecting in parallel. Connect the positive (+) terminal of
all Modules to the positive busbar. Connect the negative (-) terminal of all
Modules to the negative busbar. Refer to the parallel combination of the
Modules as shown below and make your connections accordingly.
- Y1 X1
Y2 X2
Y3 X3
Module 1
Module 2
Module N
Figure 6: Modules connected in parallel
This user manual is subject to change without notice and at the sole
discretion of ENERCAP www.enercap.energy
Page 15/15