VONROC SP505AC,SP506AC Submersible Dirty Water Pump Instructions

August 29, 2024
VONROC

VONROC SP505AC,SP506AC Submersible Dirty Water Pump

The cable length between the float switch (3) and the float switch lock (2) must always be at least 10 cm.

Product Information

Specifications:

  • Model: SP505AC / SP506AC
  • Application: Submersible Dirty Water Pump
  • Inlet Sizes: 25mm (1 inch), 32mm (1 1/4 inch)
  • Intended Use: Draining flooded areas, transferring water, drawing from wells, draining boats
  • Not Suitable for: Explosive, corrosive, flammable substances, sewage, salt water, grease, oil

Product Usage Instructions

Safety Instructions
It is crucial to read and understand the safety warnings and instructions provided with the product to prevent electric shock, fire, or injury. Always follow the safety guidelines mentioned in the manual.

Electrical Safety
Ensure compliance with the electrical safety regulations in your country. Check the voltage on the rating plate matches the power supply. The machine must be earthed to avoid electrical shock.

Power Supply Connection
Use the appropriate power supply and plug as specified by the machine. Any changes should be done by a qualified electrician.
Make sure the power supply outlet is earthed to prevent electrical hazards.

Cable and Plug Replacement
If the cord is damaged, only replace it with assistance from the manufacturer or qualified persons. Do not insert a plug of a loose cable into a wall outlet as it can be dangerous.

Machine Information
The pump is designed for draining flooded areas, transferring water, drawing from wells, and draining boats. Do not use it for conveying explosive, corrosive, flammable substances, sewage, salt water, grease, or oil.

Frequently Asked Questions (FAQ)

  1. Q: Can this pump be used for pumping saltwater?
    A: No, this pump should not be used for conveying saltwater as mentioned in the instructions. It is not suitable for corrosive substances like saltwater.

  2. Q: What should I do if the power supply voltage does not match the rating plate?
    A: If there is a mismatch in the power supply voltage, do not connect the pump. Consult a qualified electrician to address this issue before use.

  3. Q: Is it safe to replace the cable or plug myself if damaged?
    A: No, it is recommended to have the manufacturer or qualified persons replace any damaged cords or plugs to ensure safety and prevent hazards.

SAFETY INSTRUCTIONS

Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference.
The following symbols are used in the user manual or on the product:
****Read the user manual.
Denotes risk of personal injury, loss of life or damage to the tool in case of nonobservance of the instructions in this manual.
Indicates electrical shock hazard.
Protect the appliance against frost.
Max depth.
Do not dispose of the product in unsuitable containers.
The product is in accordance with the applicable safety standards in the European directives.

SAFETY NOTES
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL
CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. THE PLUG MUST BE REMOVED FROM THE SOCKETOUTLET BEFORE CLEANING OR MAINTAINING THE APPLIANCE.
Please read these instructions carefully and thoroughly before using this appliance and keep them for future reference. It is very important that you understand how to use this appliance safely so please take the time to familiarise yourself with the requirements as outlined in these instructions.

  • If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
  • Electrical connection must be protected by a residual current device (RCD) at the power socket with a nominal trip current of 30mA (max).
  • Keep children and pets well away from the work area and never allow children to use this appliance or touch the extension cord at any time. When not in use, keep this appliance stored in a safe place out of reach of children.
  • Never leave the appliance unattended when in use.
  • Never pull the appliance by its power cord. Carry it using the carry handle.
  • Do not allow the power cord to lay on or across sharp objects that might pierce the outer insulation. Carry out a visual inspection of the power cord before use and if it is damaged, have it replaced by a specialist service centre. Do not use the appliance if the cord is damaged.
  • Keep the power cord away from heat, frost, oil, solvents or any sharp objects or edges.
  • Electrical connections e.g. extension cable, must be protected from moisture at all times.
  • Check that the power rating on your appliance corresponds with the power rating at you mains supply. The supply voltage must be 230VAC.
  • Never run this appliance dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the appliance again.
  • Always have the appliance switched off and the plug removed from the power socket before placing it in or removing it from the water. Only switch the power back on with dry hands.
  • Never use this appliance in a pond or swimming pool while people are present in the water!
  • Do not use the pump for drinking water.
  • Corrosive, flammable or explosive substances, grease, oil, salt water and sewage must not be conveyed by the pump.
  • The pH of water must between 6.5 and 8.5.
  • The temperature of the liquid conveyed may not exceed 35 °C.

Electrical safety
When using electric machines always observe the safety regulations applicable in your country to reduce the risk of fire, electric shock and personal injury. Read the following safety instructions and also the enclosed safety instructions.
Always check that the power supply corresponds to the voltage on the rating plate.

Connecting to the power supply
Check that the power supply and plug used in accordance with your machine. Have a look at the rating plate on the machine. Any changes should always be carried out by a qualified electrician.
Warning! This machine must be earthed. If not properly earthed this machine can cause an electrical shock. Be sure that the power supply outlet is earthed. If there is any doubt, have it checked by a qualified electrician.
Warning! Avoid contact with the terminals on the plug when installing (removing) the plug to (from) the power supply outlet. Contact will cause a severe electrical shock.

Replacing cables or plugs
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Immediately throw away old cables or plugs when they have been replaced by new ones. It is dangerous to insert the plug of a loose cable in the wall outlet.

Using extension cables
Only use an approved extension cable suitable for the power input of the machine. The minimum conductor size is 1.5 mm². When using a cable reel always unwind the reel completely.

MACHINE INFORMATION

The pump is intended for private use for draining flooded house and garden areas but also for transferring water to and from tanks and pumping them out, from drawing water from wells and shafts and for draining boats and yachts. Explosive, corrosive, flammable substances, sewage, salt water, grease and oil must not be conveyed by the pump.
The particle sizes of the solids in the dirty water must not exceed the maximum particle size specified in the technical data.
This pump is not designed for continuous operation (e.g. as a swimming pool or pond circulation pump) or for stationary installations (e.g. lifting device, fountain pump).

TECHNICAL SPECIFICATIONS

Model No. SP505AC SP506AC
Application Clean or dirty water
Floating switch Yes
Voltage 230 VAC / 50Hz
Input power 850W 1100W
Max. flow rate 14000l/h 20000l/h
Max. pressure 0.75 bar 0.9 bar
Max. pumping height 7.5m 9m
Max.depth 7m
Max. particle size 25mm
Min. residual water height (manual operation) * 50mm
Switch-on height (automatic operation) ** 50cm
Switch-off height (automatic operation) 5cm
Max. water temperature 35°C
Protection IPX8
Built-in thermal motor protector Yes
Output hose connection 25mm, 32mm, G1″
Recommended inner hose diameter 32mm
Water outlet G1 1/2″
Cable length 10m
Weight 5 kg 6 kg
  • The stated residual water height is only achieved in manual operation.
    ** The switching height can vary depending on the  position of the float switch.

DESCRIPTION

The numbers in the text refer to the diagrams on page 2-3.

VONROC-SP505AC,SP506AC-Submersible-Dirty-Water-
Pump-\(1\)

  1. Carry handle
  2. Lock (float switch)
  3. Float on/off switch
  4. Base
  5. Hose connector
  6. Water outlet elbow connector
  7. Water outlet
  8. Vent hole

ASSEMBLY

The larger the hose and hose connector diameter, the greater the flow.
32mm (inner diameter) hose must be used to achieve maximum flow rate.
The lower the delivery height, the greater the flow.

Attaching the outlet hose (Fig. A, B)

VONROC-SP505AC,SP506AC-Submersible-Dirty-Water-
Pump-\(2\)

VONROC-SP505AC,SP506AC-Submersible-Dirty-Water-
Pump-\(3\)

  1. Decide which hose diameter you are going to use. See figure B.
  2. Cut off the smaller steps of the hose connector (5) that are not needed, using a suitable knife or saw (not included).This removes unnecessary flow restrictions and ensures maximum pump capacity and water flow.
  3. Screw the outlet elbow connector (6) into the water outlet (7).
  4. Screw the hose connector (5) on the outlet elbow (6).
  5. Fit the hose on to the hose connector (5) and secure with a stainless steel hose clamp (not included).
  6. Attach a suitable rope (not included) to the carry handle (1), to lower the pump into deep water and to lift the pump back out of the water. Never lower or lift the pump by its cable.

OPERATION

Never use this pump in a pond or swimming pool while people are present in the water!
Never pull the pump by its power cord. The pump must be carried by, and placed in the water using the carry handle (1) or if the water is deep, be lowered on a rope tied to the carry handle (1).
Always have the pump switched off and the plug removed from the power socket before placing it in or removing it from the water. Only switch the power back on with dry hands.
Never run this pump dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the pump again.
Automatic air bleed valve: The automatic air bleed valve eliminates any air pockets in the pump. During this process, air escapes through the vent hole (8) and air bubbles appear underwater. This is not a defect of your pump, but serves to remove air from the pump. It may take several seconds for the air to escape when the pump is immersed for the first time.

Automatic operation
The cable length between the float switch (3) and the float switch lock (2) must always be at least 10 cm.

  1. To adjust the cut-in and cut-out height, attach the float switch (3) cable to the float switch lock (2) at the required length.
  2. Lower the pump into water. It would be advisable to stand the pump on a solid platform at the bottom to keep it upright, if practical to do so. Ensure there are no obstructions around the inlet openings around the base of the pump. The inlet openings must be clear of mud or sludge at the bottom of a pool.
  3. Connect the mains plug.
  4. When the pump is lowered into the water and the power is switched on, it will start to operate as soon as the floating switch (3) reaches the minimum activation height (approx. 50cm) in the water.
  5. The pump switches off as soon as the float switch (3) has reached the switch-off height (approx. 5cm) due to the falling water level.
  6. Ensure that the float switch (3) is not obstructed in any way.
  7. After use, switch off the pump and remove the mains plug from the mains.
  8. Lift the pump back out of the water.

Manual operation
Where manual operation is preferred, the motor can be activated by raising the float switch (3) by hand (ON) or lowering it by hand (OFF).

Finish operation
After use allow the pump to run using clean water for 2 – 3 minutes in order to remove residues and particles that may have accumulated in the pump and outlet hose.

MAINTENANCE

Before cleaning and maintenance, always switch off the machine and remove the mains plug from the mains.
During maintenance or cleaning never rest the appliance of the on the turbine (impeller).
There are no user serviceable parts in this appliance. If the appliance appears to be blocked, switch off the power at the mains, remove the plug from the socket and check the appliance for blockages (see ‘Blockages’).

BLOCKAGES
If you suspect the pump has become blocked, switch off the power at the mains socket remove the plug and examine the turbine. The turbine can be accessed by removing the securing screws in the base and/or sub base. Alternately try reaching the suspected blockage through the outlet (7) in the side of the pump.
Always flush through with clean water after every use.

STORAGE AND FROST POTECTION
The submersible pump and accessories that are not completely drained can be destroyed by frost. Completely drain the submersible pump and accessories and protect them against frost.
Keep this appliance in well-ventilated dry premises with temperature not going below +5°C.
When not in use, keep this appliance stored in a safe place out of reach of children.

TROUBLE SHOOTING GUIDE

Problem Cause Remedy
Pump does not start No mains supply Floater restricted Check mains supply

Bring floater to higher position
Pump is active
but no water is
being delivered| Turbine clogged| Disconnect pump
from the power
supply and clean or
unblock the turbine
(see ‘BLOCKAGES’)
Pump will not
switch off| Floater restricted| Bring floater to a
lower position
Pump will not
start or stops
during use.
Pump switched
off after short
operating periods| Thermal overload
safety switch has
activated| Disconnect from
the power supply,
leave for 2 minutes
and clear the turbine
(if required – see
‘Blockages’)
| Power has tripped| Check fuses and
electrical connections
| Turbine clogged| Disconnect pump
from the power
supply and clean or
unblock the turbine
(see ‘BLOCKAGES’)
| Water too hot| Ensure that the water
temperature has
not exceeded the
maximum of 35 C

ENVIRONMENT
Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.

Only for EC countries
Do not dispose of power tools into domestic waste. According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way.

WARRANTY

VONROC products are developed to the highest quality standards and are guaranteed free of defects in both materials and workmanship for the period lawfully stipulated starting from the date of original purchase. Should the product develop any failure during this period due to defective material and/or workmanship then contact VONROC directly.

The following circumstances are excluded from this guarantee:

  • Repairs and or alterations have been made or attempted to the machine by unauthorized service centers;
  • Normal wear and tear;
  • The tool has been abused, misused or improperly maintained;
  • Non-original spare parts have been used.

This constitutes the sole warranty made by company either expressed or implied. There are no other warranties expressed or implied which extend beyond the face hereof, herein, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall VONROC be liable for any incidental or consequential damages. The dealers remedies shall be limited to repair or replacement of nonconforming units or parts.
The product and the user manual are subject to change. Specifications can be changed without further notice.
WWW.VONROC.COM

DECLARATION OF CONFORMITY
SP505AC / SP506AC – SUBMERSIBLE DIRTY WATER PUMP
We declare under our sole responsibility that this product is in conformity with directive 2011/65/EU of the European parliament and of the council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations: EN 60335-1, EN 60335-2-41, EN 62233, EN 55014-1, EN55014-2, EN 61000-3-2, EN61000-3-3, 2006/42/EC, 2014/30/EU, 2011/65/EU, (EU)2015/863, 2012/19/EU
VONROC • Lingenstraat 6 • 8028 PM Zwolle • The Netherlands
©2024 VONROC
WWW.VONROC.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals