veratron B000610 Liquid Level Sensor Installation Guide
- August 28, 2024
- veratron
Table of Contents
B000610 Liquid Level Sensor
“`html
Specifications
- Connector: 5-pin
- IP Protection Class: IP67
- Rated Voltage: N/A
- NMEA 2000 LEN: N/A
- NMEA 2000 Data: PGN 127505
Product Usage Instructions
Before Assembly
Ensure to remove the ignition key and detach the battery
negative pole terminal to avoid short circuits, cable burning, or
battery explosion.
Installation Position
Always check the tank depth compared to sensor height. Install
the sensor in the upper part of the tank at the most favorable
point. Use the installation aperture provided by the tank
manufacturer.
Drilling the Tank
If an installation aperture needs to be made, ensure the water
tank is completely emptied. Drill small holes at the installation
apertures and then enlarge the hole using appropriate tools. Clean
the tank of any residue after drilling and refill it with fresh
water once installation is complete.
Cleaning the Sensor
To clean the sensor, remove it from the tank and rinse the
measuring probes under running water. Use a soft brush to remove
any stubborn fouling, taking care not to damage the probes’
coating. Clean the tank with water after emptying it.
Box Contents
The package should contain the sensor along with necessary
connectors and instructions.
FAQ
Q: Can the sensor be submerged in water?
A: The sensor is designed for use in tanks and should not be
fully submerged in water.
Q: What is the maximum length for the NMEA 2000 drop
cable?
A: The maximum drop cable length should not exceed 6 meters.
“`
DE
NMEA 2000® Füllstandssensor
EN FR
NMEA 2000® Liquid Level Sensor
Capteur de niveau de liquide NMEA 2000®
Sensor de nivel
ES líquido NMEA
2000® Sensore livello
IT serbatoi NMEA
2000® Sensor de nível
PT de enchimento
NMEA 2000®
Installationsanleitung / Installation instruction / Instructions
d’installation/ Instrucciones para la instalación / Istruzioni per
l’installazione / Instruções de instalação
B000610 | 03-2020
mm
Pin 1 Shield 2 NET-S (V+) 3 NET-C (V-) 4 NET-H (CAN H) 5 NET-L (CAN L)
www.veratron.com/downloads
veratron AG Industriestrasse 18, 9464 Rüthi,
Switzerland
w w w . v e r a t r o n . c o m i n f o @ v e r a t r o n . c o m
Der Inhalt kann jederzeit geändert werden / Content subject to change /
Contenu sujet à modification / Contenidos sujetos a modificación / Contenuti
soggetti a modifica / Conteúdo sujeito a modificação © 2020 veratron AG
DE
Vor der Montage
ACHTUNG: Kurzschluss. Kabelbrand, Batterieexplosion. Ziehen Sie den
Zündschlüssel ab und trennen Sie die Klemme vom Minuspol der Batterie
Verwenden Sie ein NMEA 2000 DropKabel mit fünfpoligem M12-Stecker
(DropKabellänge max. 6m, Stecker/Buchse).
Einbauort
ACHTUNG: Stets die Tiefe des Tanks im Vergleich zur Höhe des Gebers prüfen.
Der Geber muss immer im oberen Teil des Tanks eingebaut werden.
Installieren Sie den Geber an der vom Tankhersteller schon vorgesehenen
Montageöffnung (Montageflansch).
Die günstigste Stelle für die Montageöffnung liegt bei einem rechteckigen
Wassertank in der Mitte des Tanks, bei Wassertanks mit anderer Geometrie auf
ca. einem Drittel zur tiefen Seite.
Bohren des Tanks
Muss eine Montageöffnung hergestellt werden, entleeren Sie den Wassertank
vorher vollständig. Bauen Sie wenn möglich den Tank aus.
Bohren Sie die Montageöffnung klein vor. Verwenden Sie Konusfräser, Loch-,
Stichsäge oder Feile, um die Bohrung zu vergrößern und fertigzustellen.
Entgraten Sie die Kanten. Beachten Sie unbedingt die Sicherheitshinweise der
Handwerkzeughersteller.
Wassertank von Bohr-, Feil- und Sägerückständen reinigen. Füllen Sie nach
erfolgtem Einbau den Wassertank wieder mit Frischwasser auf.
Sensor reinigen
Um einen zuverlässigen Betrieb des Gebers im Schmutzwassertank zu
gewährleisten ist dieser von Zeit zu Zeit zu reinigen. Zur Reinigung
demontieren Sie den Tankgeber und spülen Sie die beiden Messstäbe unter
fließendem Wasser. Hartnäckige Verschmutzungen sind mit einer weichen Bürste
vorsichtig zu entfernen. Beschädigen Sie dabei nicht die weiße Beschichtung
der Stäbe. Der Tank sollte nach dem abpumpen mit Wasser gespült werden.
Inhalt der Verpackung
· NMEA 2000 ® Füllstandssensor · Dichtungssatz N05-016-930 · Diese
Installationsanleitung
Technische Daten
Stecker
IP-Schutzart Nennspannung NMEA 2000 LEN
NMEA 2000® Micro-C 5polig M12 IP X9K 12V (NMEA 2000®) 2
NMEA 2000-Daten
PGN 127505
Beschreibung Flüssigkeitsstand
EN
Before assembly
NOTICE: Short circuit. Cable burning, battery explosion. Remove the ignition
key and detach the battery negative pole terminal.
Purchase an NMEA 2000 drop cable with five-pin M12 connector (max. drop cable
length 6m, male-female connectors).
Installation position
NOTICE: always check the tank depth compared to sensor height. The sensor must
always be installed in the upper part of the tank.
Install the sensor in the installation aperture provided for by the tank
manufacturer (installation flange).
The most favorable point for the installation aperture is in the center of the
tank cover in the case of rectangular tank, and at about one third towards the
deep side in the case of other tanks.
Drilling the tank
If an installation aperture has to be made, the water tank must first be
emptied completely. If possible, remove the tank.
First drill small holes at the installation apertures. Use tapered drills,
compass saws, fretsaws or files to enlarge and complete the hole. Deburr the
edges. The safety instructions of the hand tool manufacturer must be observed.
Clean the tank of residue from drilling, filing and sawing. When installation
is finished, refill the water tank with fresh water.
Cleaning the sensor
The transducer must be cleaned from time to time in order to ensure its
reliable operation in the waste-water tank. For the purpose of cleaning,
please remove the tank’s transducer and rinse the two measuring probes under
running water. Carefully remove any stubborn fouling using a soft brush. Be
careful not to damage the white coating of the probes while performing this
work. The tank should be cleaned with water after pumping it empty.
Box contents
· NMEA 2000® Liquid Level Sensor · Sealing kit N05-016-930 · These
installation instructions
Technical specifications
Connector
IP protection class Rated voltage
NMEA 2000 LEN
NMEA 2000® Micro-C 5-pin M12 male IP X9K
12V (NMEA 2000®) 2
NMEA 2000 Data
PGN 127505
Description Fluid Level
FR
Avant le montage
AVIS: court-circuit. Combustion des câbles, explosion des batteries. Retirer
la clé de démarrage et débrancher la cosse du pôle négatif de la batterie.
Se procurer un câble de dérivation NMEA 2000 avec connecteur M12 à cinq
broches (longueur maximum de câble de dérivation 6m, connecteurs mâle-
femelle).
Position d’installation
AVIS: toujours vérifier la profondeur du réservoir par rapport à la hauteur du
capteur. Le capteur doit toujours être installé dans la partie supérieure du
réservoir.
Installer le capteur sur l’ouverture de montage déjà prévue par le
constructeur du réservoir (bride de montage).
L’emplacement le plus avantageux pour l’ouverture de montage se trouve au
milieu du couvercle du réservoir, dans le cas d’un réservoir à eau
rectangulaire. Dans le cas d’autres réservoirs à eau, il se trouve à environ
un tiers par rapport à l’endroit le plus profond.
Percer le réservoir
Lorsque l’obligation se présente de confectionner une ouverture de montage, le
réservoir à eau devra être vidé intégralement au préalable. Démonter si
possible le réservoir.
Percer au préalable les ouvertures de montage de petit diamètre. Utiliser une
fraise conique, une scie sauteuse pour trous ou une lime pour agrandir le trou
et pour le finir. Ebavurer les bords. Observer à tout prix les consignes de
sécurité du fabricant des outillages portatifs.
Nettoyer le réservoir à eau pour le débarrasser des résidus de perçage, de
limage et de sciage. Une fois que le réservoir à eau a été monté, le remplir à
nouveau d’eau fraîche.
Nettoyer le capteur
Nettoyez de temps en temps le transmetteur pour garantir qu’il fonctionne de
manière irréprochable dans la citerne d’eaux sales. Pour le nettoyage,
démontez le transmetteur de la citerne et rincez les deux jauges à l’eau
courante. Eliminez avec précaution les saletés persistantes avec une brosse
douce. Veillez alors à ne pas endommager le revêtement blanc des jauges. Après
la vidange, le réservoir doit être rincer avec de l’eau.
Contenu de l’emballage
· NMEA 2000® Capteur de niveau · Kit détanchéité N05-016-930 · Ces
instructions d’installation
Données techniques
Connecteur
Indice de protection IP Alimentation électrique NMEA 2000 LEN
NMEA 2000® Micro-C 5broches M12 mâle IP X9K
12V (NMEA 2000®) 2
Données NMEA 2000
PGN 127505
Description Niveau liquide
ES
Antes del montaje
AVISO: cortocircuito. Quemadura cables, explosión baterías. Extraiga la llave
de encendido y desconecte el borne del polo negativo de la batería.
Prepare un cable de derivación NMEA 2000 con conector M12 de cinco pines
(longitud del cable de derivación máx. 6m, conectores macho-hembra).
IT
Prima del montaggio
AVVISO: cortocircuito. Bruciatura cavi, esplosione batterie. Estrarre la
chiave di accensione e staccare il morsetto del polo negativo della batteria.
Procurarsi un cavo di derivazione NMEA 2000 con connettore M12 a cinque pin
(lunghezza cavo di derivazione max. 6m, connettori maschio-femmina).
PT
Antes da montagem
AVISO: curto-circuito. Queima de cabos, explosão de baterias. Extraia a chave
de ligação e desconecte o terminal do polo negativo da bateria.
Prepare um cabo drop NMEA 2000 com um conector M12 de 5 pinos (comprimento do
cabo drop 6m, conectores macho-fêmea).
Posición de instalación
AVISO: verifique siempre la profundidad del depósito respecto a la altura del
sensor. El sensor debe instalarse siempre en la parte superior del depósito.
Instalar el transmisor en la abertura de montaje (brida de montaje) ya
prevista por el fabricante del tanque.
El lugar más favorable para la abertura de montaje en un tanque de agua
rectangular, está en el centro de la tapa del tanque, en otros tanques de agua
a un tercio de la cara del fondo.
Perforar el tanque
Si se debe hacer una abertura de montaje, previamente vaciar el tanque de agua
por completo. Cuando sea posible, desmontar el tanque.
Taladrar las aberturas de montaje a un diámetro inferior al definitivo.
Emplear una fresa cónica, una sierra de perforar, un serrucho de calar o una
lima, para ampliar los agujeros y terminarlos. Desbarbar las aristas. Observar
obligatoriamente las Indicaciones de Seguridad del fabricante de la
herramienta manual.
Limpiar el tanque de agua de las virutas de taladrar, serrar y limar. Después
de realizado el montaje del tanque, llenarlo de nuevo con agua dulce.
Limpiar el transmisor
Para garantizar un funcionamiento fiable del transmisor situado en el depósito
de aguas residuales, éste deberá limpiarse periódicamente. Para efectuar la
limpieza, desmonte el transmisor del depósito y enjuague con agua corriente
las dos varillas de medición. La suciedad persistente deberá eliminarse
cuidadosamente con un cepillo suave. Preste atención a no dañar el
revestimiento blanco de las varillas. El tanque debe limpiarse con agua
despues de vaciar la bomba.
Contenido del paquete
· Sensor de nivel líquido NMEA 2000® · Juego de juntas N05-016-930 · Estas
instrucciones para la instalación
Datos técnicos
Conector
Grado de protección IP Alimentación eléctrica NMEA 2000 LEN
NMEA 2000® Micro-C 5pines M12 macho IP X9K
12V (NMEA 2000®) 2
Datos NMEA 2000
PGN 127505
Descripción Nivel liquido
Posizione di installazione
AVVISO: verificare sempre la profondità del serbatoio rispetto all’altezza del
sensore. Il sensore deve essere installato sempre nella parte superiore del
serbatoio.
Installare il sensore nel vano di montaggio già previsto dal produttore del
serbatoio (flangia di montaggio).
La posizione più favorevole per il vano di montaggio si trova, nei serbatoi
quadrati, al centro del serbatoio, mentre, nei serbatoi con forme diverse, si
trova a circa un terzo del lato profondo.
Forare il serbatoio
Qualora debba essere realizzato un vano di montaggio, svuotare precedentemente
il serbatoio dell’acqua completamente. Se possibile, smontare il serbatoio.
Praticare inizialmente un piccolo foro per il vano di montaggio. Utilizzare
una fresa conica, una sega a tazza, un seghetto alternativo o una lima per
allargare e completare il foro. Smussare i bordi. Rispettare assolutamente le
avvertenze di sicurezza del produttore dell’utensile.
Rimuovere dal serbatoio i residui di lavorazione derivanti dalla realizzazione
del foro con trapano, sega o lima. A montaggio eseguito, riempire nuovamente
il serbatoio con acqua dolce.
Pulizia del sensore
Per assicurare un funzionamento affidabile del sensore nei serbatoi dell’acqua
di scarico, il sensore stesso va pulito periodicamente. Per il lavaggio,
smontare il sensore del serbatoio e risciacquare entrambi gli steli di
misurazione con acqua corrente. Le incrostazioni di sporco vanno rimosse con
cautela con una spazzola soffice. Nel farlo, assicurarsi di non danneggiare il
rivestimento bianco degli steli. Il serbatoio dovrebbe essere risciacquato con
acqua dopo essere stato svuotato.
Contenuto della confezione
· Sensore livello acque NMEA 2000® · Kit di fissaggio N05-016-930 · Queste
istruzioni di installazione
Dati tecnici
Connettore
Grado di protezione IP Alimentazione NMEA 2000 LEN
NMEA 2000® Micro-C 5-pin M12 maschio IP X9K
12V (da rete NMEA 2000®) 2
Dati NMEA 2000
PGN 127505
Descrizione Livello del Liquido
Posição de instalação
AVISO: Sempre verifique a profundidade do tanque em relação à altura do
sensor. O sensor sempre deve ser instalado em cima do tanque.
Instale o transmissor na abertura de montagem (flange de montagem) já
fornecida pelo fabricante do tanque.
O local mais favorável para a abertura de montagem em um tanque de água
retangular é no centro da tampa do tanque, em outros tanques de água, um terço
da face inferior.
Perfurar o tanque
Se for necessária uma abertura de montagem, esvazie completamente o tanque de
água. Quando possível, desmonte o tanque.
Perfure as aberturas de montagem com um diâmetro menor que o diâmetro final.
Use uma broca cônica, uma serra, um quebra-cabeças ou uma lima para ampliar os
furos e finalizá-los. Rebarbar as bordas. Siga as instruções de segurança do
fabricante da ferramenta manual.
Limpe o tanque de água da broca, serra e lascas de arquivo. Depois de montar o
tanque, encha-o novamente com água fresca.
Limpe o transmissor
Para garantir uma operação confiável do transmissor localizado no tanque de
águas residuais, ele deve ser limpo regularmente. Para limpar, remova o
transmissor do tanque e enxágue os dois varetas com água corrente. A sujeira
persistente deve ser cuidadosamente removida com uma escova macia. Preste
atenção para não danificar o revestimento branco das hastes. O tanque deve ser
limpo com água após esvaziar a bomba.
Conteúdo da Embalagem
· Sensor de nível de líquido NMEA 2000® · Conjunto de juntas N05-016-930 ·
Estas instruções de instalação
Dados técnicos
Conector
Grau de proteção IP Alimentação elétrica NMEA 2000 LEN
NMEA 2000® Micro-C 5pines M12 macho IP X9K
12V (NMEA 2000®) 2
Dados NMEA 2000
PGN 127505
Descrição Nível líquido
L
A
A
Min. 10mm Max. 15mm
6. #1
Schnelles Blinken / Fast blinking / Clignotement rapide / Parpadeo rápido /
Lampeggio veloce / Piscando rapidamente
Langsames Blinken / Slow blinking / Clignotement lent / Parpadeo lento /
Lampeggio lento
/ Piscando lentamente
ON
OFF
OK ERROR
Tank 1 Réservoir 1
Tanque 1 Serbatoio 1
Tank 2 Réservoir 2
Tanque 2 Serbatoio 2
Tank 3 Réservoir 3
Tanque 3 Serbatoio 3
Tank 4 Réservoir 4
Tanque 4 Serbatoio 4
2
DE: Weitere Konfigurationen sind möglich, erfordern jedoch das Veratron- Konfigurationstool. Dies ermöglicht die Installation von bis zu 15 Tanks, nichtlinearen Füllkurven und Livewell- oder Schwarzwassertanks.
EN: Further configurations are possible but require the Veratron Configuration Tool. This allows the installation of up to 15 tanks, nonlinear fill curves and livewell or black water tanks.
IT: Ulteriori configurazioni sono possibili, ma richiedono lo Strumento di Configurazione Veratron. Questo consente l’installazione fino a 15 serbatoi, curve di riempimento non lineari e serbatoi per l’acqua viva o nera.
Frischwasser / Fresh Water / Eau douce / Agua dulce / Acque chiare / Agua doce
FR: D’autres configurations sont possibles mais nécessitent l’outil de configuration Veratron. Cela permet l’installation de jusqu’à 15 réservoirs, des courbes de remplissage non linéaires et des réservoirs pour eaux de vivier ou eaux noires.
Schmutzwasser / Waste Water / Eaux usées / Aguas residuales / Acque scure /
Agua residual
ES: Se pueden realizar otras configuraciones pero requieren la herramienta de configuración Veratron. Esto permite la instalación de hasta 15 tanques, curvas de llenado no lineales y tanques para agua viva o negra.
PT: Outras configurações são possíveis, mas requerem a Ferramenta de
Configuração Veratron. Isso permite a instalação de até 15 tanques, curvas de
enchimento não lineares e tanques para água viva ou água negra.
B000610
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>