GVS C40 Supplied Air Respirator Installation Guide
- August 28, 2024
- GVS
Table of Contents
- GVS C40 Supplied Air Respirator
- Product Usage Instructions
- Components & Best Practices
- Setting Up a Supplied Air
- Air Source
- Air Monitoring & Filtration
- Air Distribution to Operators
- Installation Guidance
- Your Guide to Selecting a Respirator by Application
- Supplied Air Products & Part Numbers
- FAQ
- answer-1=
- answer-3=
- answer-5=
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GVS C40 Supplied Air Respirator
Specifications
- Product Name: Supplied Air Respirators
- Components: Air source, Air filtration, Gas monitor, Air distribution, NIOSH-approved respirator assembly
Product Usage Instructions
Setting Up a Supplied Air Respiratory Protection System
The process of setting up a supplied air respiratory protection system may
seem complex but can be simplified with the following steps:
-
Planning Process
Involve the Plant Manager, Safety Officer, Maintenance and electrical team, and your respiratory protection manufacturer in the planning process. -
Basic Components
Ensure you have the necessary components for a supplied air system: Air source, Air filtration, Gas monitor, Air distribution, and a NIOSH-approved respirator assembly. -
NIOSH Approved Respirator Assembly
Assemble the NIOSH-approved respirator assembly with components like Headtop Breathing Tube, Flow Control Device, and Airline Hose with Coupler. Ensure all components are from the same manufacturer for compliance. -
Additional Requirements
Implement a written respiratory protection program meeting OSHA standards, conduct medical evaluations for employees, and perform fit-testing if using tight-fitting respirators.
Air Source
-
Compressor Placement
Place the compressor in an area with clean air to prevent contamination from vents or exhaust. -
Compressor Size/Capacity
Consider a Breathing Air Compressor System dedicated to breathing air with filtration and monitoring capabilities to meet air quality standards. -
Air Quality
Ensure the compressor air meets Grade D breathing air requirements as per OSHA guidelines.
Components & Best Practices
Setting Up a Supplied Air
Respiratory Protection System
- The process of setting up a supplied air respiratory protection system can at first appear complicated, but we are here to simplify the process!
- While the specific needs of every facility will be different, this document will provide you with a basic overview of what is needed and points for consideration when setting up a supplied air system.
Who should be involved in the planning process?
- Plant Manager
- Safety Officer
- Maintenance and electrical team
- Your respiratory protection manufacturer – as your respiratory protection manufacturer we are here to provide expert advice to make sure you get set up with a system that is safe, efficient, and practical for your team members.
Basic Components of a Supplied Air System:
- Air source
- Air filtration
- Gas monitor
- Air distribution
- NIOSH approved respirator assembly.
NIOSH Approved Respirator Assembly
A NIOSH approved respirator assembly, often referred to as “hose to nose” to
clarify the assembly’s start and end points, is made up of the following
components. For NIOSH certification, all these components must be from the
same manufacturer and not interchangeable with parts from other brands to
ensure compliance.
- Headtop
- Breathing Tube: Connects the headtop to the flow control device.
- Flow Control Device: Controls the flow rate of air entering the headtop (pictured is the C40™ Flow Control Device, which can also heat and cool the incoming air).
- Airline Hose with Coupler.
Maintenance Tip:
Proper storage of the airline hose via a hose reel or hose rack will prevent
early damage to hoses and couplers.
Additional Requirements:
A written respiratory protection program that meets OSHA’s Respiratory
Protection Standard requirements Medical evaluation for employees to assess
their suitability for wearing the chosen respirator assembly Fit-testing (if
using tight-fitting respirators).
Air Source
The most common air source to a supplied air system is a High-Pressure Air Compressor.
Compressor Placement
The compressor should be located in an area with “clean air” to minimize the
risk of contamination, i.e. away from vents and equipment or vehicle exhaust.
Compressor Size/Capacity
- It is important to ensure the compressor will be able to accommodate the airflow required per respirator assembly. This is measured in cubic feet per minute (CFM), and will also vary based on the length of airline hose and type of flow control device being used. All supplied air respirator manufacturers will include a Breathing Air Pressure Chart detailing the air pressure requirements for that particular respirator set up (see example on page 7).
- If your facility has an existing compressor that provides air drops throughout a facility you will need to confirm that the existing system is suitable for Grade D Breathing Air and can provide the required CFM to each operator.
Breathing Air Compressor Systems
A Breathing Air Compressor System is a compressor specifically dedicated to
breathing air and may be an option you want to consider. These compressors
often have filtration and carbon monoxide monitoring incorporated into the
compressor setup, in which case additional in-line gas monitoring and
filtration components are not needed.
Air Quality
Per OSHA, the compressor air must meet Grade D breathing air requirements as
described in ANSI/Compressed Gas Association Commodity Specification for Air
G-7.1-2018.
Requirements for Grade D breathing air:
- Oxygen content between 19.5-23.5%
- Hydrocarbon (condensed) content of 5 milligrams per cubic meter of air or less
- Carbon monoxide (CO) content of 10 ppm or less Carbon dioxide content of 1,000 ppm or less
- Lack of noticeable odor.
Testing
- Although OSHA does not specify a time interval for testing, industry standard is to test annually and/or following any maintenance of your compressor.
- There are third party testing labs dedicated to compressed air testing and even specializing in breathing air standards.
- There are also companies that will provide you with an Air Sampling Kit, and a pass certificate upon your sampling achieving the target air quality.
Air Monitoring & Filtration
Compressed breathing air must be monitored for Carbon Monoxide levels; some facilities may also require monitoring for additional gases such as Oxygen and Hydrogen Sulfide. Compressed air must be filtered to ensure any excess moisture or oil is removed. GVS- RPB® gas monitoring and filtration options include:
GX4® Gas Monitor
- Can monitor for Carbon Monoxide (CO), Oxygen (O2), and Hydrogen Sulfide (H2S)
- Connects to Radex airline filter
- Regular testing of the alarm and sensor cartridges should be undertaken every 30 days to ensure they are within calibration
- Real time monitoring with alarm and optional strobe.
GX4 Power Options:
For maximum flexibility when it comes to job sites, the GX4 can be set up in
two different power configurations. 12V DC Cable with Battery Clips for remote
job sites, or 110/240V AC Adapter Plug for longer term applications.
Radex® Airline Canister
- Can be wall or floor mounted 2-outlet or 6-outlet Radex configurations are available
- The 6-stage filter cartridge removes moisture, odor, and particulates down to 0.5 microns from the compressed air stream
- Radex filter cartridge replaced approximately every 3-months
- Attachments can be added on to provide additional filtration and air pressure regulation.
The Radex Filter system contains 6-stages of filtration media, to further filter compressed air and protect the respirator user from solid and/or liquid particulates, such as dusts 0.5 microns in size or larger, mists and/or odors. The filter system DOES NOT filter CO-Carbon Monoxide.
Safety Tip: The optional GVS-RPB Auxiliary Strobe Light and Alarm connects to the GX4 as an additional safety measure. With a 50ft cable it should be positioned in a location easily visible to all operators connected to that air supply.
Air Distribution to Operators
Hose Length
- The maximum length of hose allowed, as determined by the Code of Federal Regulations and measured from the Point of Attachment to the operator, is 300 feet.
- GVS-RPB® offers hoses in lengths of 25, 50 and 100 feet.
Fittings
- Each manufacturer has approved fittings for use with their respirator assemblies. It’s important to understand the use of any non-approved fitting will void the NIOSH approval of the assembly.
- GVS-RPB’s standard fittings include RPB Quick Disconnect, Schrader, and the RZ fitting (proprietary to GVS-RPB).
Point of Attachment
- The Point Of Attachment (POA), is where the fitting on an Air Supply Hose attaches to the compressed air source. The point of connection when using GVS-RPB Radex® Filtration, is at the coupler at the top of the Radex.
- For safety reasons, all of the components used from the Point of Attachment to the Respirator MUST all be of the same manufacturer. As seen here in our NIOSH approved Respirator Assembly Components.
Air Supply Hoses
Safety Tip: Always inspect airline hoses and couplers for visible wear and tear before each use.
Check out the GVS-RPB Daily Checklist for Supplied Air Respirators: www .gvs-rpb.com/discover/using-your-respirator/know-the-life-of-your- respirator
Pressure Settings
The GVS-RPB® Respirators, NOVA 3®, NOVA 2000®, Z-Link®, Z4®, T-Link®, and
T200™ all require air pressure ranges to provide a volume of air that falls
within the required range of 6-15CFM or 170-425lpm according to U.S.
Government regulations, (42 CFR, Part 84, Subpart J, 84.150). Breathing table
charts can be found in the Instruction Manuals for each respirator for further
reference. Pressure settings are determined by a combination of factors: Air
Source, Type of Air Supply Hose, Flow Control, Air Supply Hose Length, and
Number of Sections of Hose. Airline hoses can only be used in 25’, 50’, and
100’ sections, and up to 300’ total maximum.
Calculating Pressure Settings
To calculate the correct breathing pressure required, follow the steps below,
ensuring you are referencing the correct Breathing Air Pressure Table for your
specific head top.
- Use the correct air source. Do not use an ambient air pump, as it does not supply enough pressure (column 1).
- Confirm the part number of the air supply hose you are using (column 2), and the flow control device you are using (column 3).
- Check your GVS-RPB Air Supply Hose is within the correct length (column 4) and the correct number of hose sections (column 5).
- Set the air pressure at the point of attachment within the range specified (column 6).
Scan this QR code
View and download GVS-RPB Breathing Air Pressure Tables (located within GVS-
RPB Headtop Instruction Manuals), which include additional breathing airline
hose options: 04-342-25, 04-342-50, 04-342-100, 04-412-15, 04-412-25,
04-442-15, and 04-442-25.
Example : Z-Link Breathing Air Pressure Table
The below page from the Z-Link user manual details the air pressure
requirements for various set ups. I.e. A Z-Link respirator using a Constant
Flow Valve and connected to a 50ft airline hose will require 12-14PSIG,
whereas a Z-Link respirator using a C40™ Climate Control Device and connected
to an airline hose with a total length of 200ft will require a much higher
pressure of 75-100PSIG.
BREATHING AIR PRESSURE TABLE
S – SPECIAL OR CRITICAL USERS INSTRUCTIONS – SAR TABLE 1.1
This table lists air pressure ranges needed to provide the RPB Z-LINK with the
volume of air that falls within the required range of 6-15cfm or 170-425
lts/min according to U.S. government regulations. Maximum hose pressure is 300
psi.
1. AIR SOURCE
|
2. AIR SUPPLY HOSE
| 3. FLOW CONTROL DEVICE USED WITH 04‑830 BREATHING
TUBE ASSEMBLY
|
4. SUPPLY HOSE
LENGTH (FT)
| 5. MAX NUMBER
OF
SECTIONS
| 6.
PRESSURE RANGE
(PSIG AIR)
---|---|---|---|---|---
Portable or Stationary Compressor Portable or Stationary Compressor
|
NV2028 (25ft) NV2029 (50ft)
NV2027 (100ft) 04‑352‑25‑RZ (25ft)
04‑352‑50‑RZ (50ft)
04‑352‑100‑RZ (100ft)
|
03‑101 Constant Flow Valve Assembly (High Pressure)
| 25
50
100
150
200
250
300
| 1
1
2
3
4
5
6
| 10 ‑ 14
12 ‑ 14
17 ‑ 19
21 ‑ 23
25 ‑ 27
28 ‑ 31
31 ‑ 34
03‑500 C40 Climate Control Assembly
|
25
50
100
150
200
250
300
|
1
1
2
3
4
5
6
|
55‑80
60‑85
65‑95
70‑95
75‑100
80‑100
90‑100
04‑342‑25 (25ft)
04‑342‑50 (50ft)
04‑342‑100 (100ft)
|
03‑101 Constant Flow Valve Assembly (High Pressure) with Schrader Fitting
| 25
50
100
150
200
250
300
| 1
1
2
3
4
5
6
| 20‑22
24‑26
28‑30
32‑34
36‑38
38‑40
44‑46
03‑500 C40 Climate Control Assembly
with Schrader Fitting
|
25
50
100
150
200
250
300
|
1
1
2
3
4
5
6
|
65‑80
70‑85
75‑95
80‑95
85‑100
90‑100
95‑100
04‑412‑15 (15ft)
04‑412‑25 (25ft)
| 03‑101 Constant Flow Valve Assembly (High Pressure)| 15
25
| 1
1
| 9 ‑ 14
11 ‑ 15
03‑500 C40 Climate Control Assembly| 15
25
| 1
1
| 55 ‑ 80
55 ‑ 80
04‑442‑15 (15ft)
04‑442‑25 (25ft)
| 03‑101 Constant Flow Valve Assembly (High Pressure) with Schrader Fitting|
15
25
|
1
1
|
21‑30
23‑33
03‑500 C40 Climate Control Assembly
with Schrader Fitting
|
15
25
|
1
1
|
65‑80
65‑80
Installation Guidance
Hard Ducting from Radex vs. Running Airline Hose direct from Radex
In some cases, due to the amount of operators or work area conditions, you may
want to consider hard ducting from the Radex Filter rather than running
airline hoses initially. Be sure when choosing to use hard ducting to consider
pressure drop calculations and ducting materials. When choosing to hard duct,
each new connection should be provided with an additional pressure gauge with
relief valve to assure recommended pressures. Then at each new connection,
GVS-RPB® Breathing Airline Hoses should
be connected at that point.
Example shown in the illustration below.
Heavy-Duty Case and its Purpose
Due to most environments, it is best to keep the GX4® protected from the
elements, see page 11 for Heavy-Duty Carry Case.
Maintenance and Benefits of C40™ Cooling/Heating Vortex
The C40 Cooling and Heating Vortex, can withstand extreme conditions of work
environments. It is built for longevity with the ability to be cleaned and
maintained. As seen here, all components can be cleaned and/or replaced. See
the C40 Operations Manual online for more details.
Your Guide to Selecting a Respirator by Application
Explore the versatility of GVS-RPB® headtops that pair seamlessly with the Radex® Airline Filter and GX4® Gas Monitor across various industries. Discover the perfect match for your application with our comprehensive range.
Common Terminology
- CFM : Cubic feet per minute. Used in relation to a respirator’s required airflow.
- Fit Test: The use of a protocol to assess the fit of a respirator on an individual. This can be done based on a qualitative (QLFT) or quantitative (QNFT) method.
- NIOSH: The National Institute for Occupational Safety and Health.
- NIOSH Approved Respirator: OSHA permits only NIOSH approved respirators to be used to protect workers. A NIOSH approved respirator has been evaluated and found to comply with all requirements of Title 42, Code of Federal Regulations, Part 84 and the manufacturer’s Quality Management Plan has also been assessed and found to be satisfactory.
- OSHA : Occupational Safety and Health Administration.
- POA: Point of Attachment. The point at which the respirator assembly connects to the supplied air source.
- Respiratory Protection Program: A written respiratory protection program with required worksite-specific procedures and elements for required respirator use, such as respirator selection, cleaning, storage, fit testing, medical evaluations, and worksite-specific training.
References & Helpful Links
- OSHA Respiratory Protection Standard: www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.134 NIOSH approves respirators in accordance with 42 Code of Federal Regulations Part 84 and provides guidance for their use in occupational settings: www.cdc.gov/niosh/topics/respirators/
- Code of Federal Regulations: www.ecfr.gov/current/title-42/chapter-I/subchapter-G/part-84/subpart-J
Supplied Air Products & Part Numbers
Want to know more? Get in touch with our team today!
AMERICAS
- Argentina
- Tel. +54-114-988-9041
- gvsarg@gvs.com
- Brazil
- Tel. +55-193-879-7200
- gvs@gvs.com.br
- Mexico
- Tel. +52-81-2282-9003
- gvsmex@gvs.com
- U.S.A.
- Tel. +1-866-494-4599
- respirators@gvs.com
EUROPE
- Italy (Head Office)
- Tel. +39-051-617-6311
- gvs@gvs.com
- Romania
- Tel. +40-244-463044
- gvsromania@gvs.com
- Turkey
- Tel. +90-216-504-4767
- gvsturkey@gvs.com
- United Kingdom
- Tel. +44-(0)-1524-847-600
- gvsuk@gvs.com
ASIA-PACIFIC
- China
- Tel. +86-512-6661-9880
- gvschina@gvs.com
- India
- Japan
- Tel. +81-3-5937-1447
- gvsjapan@gvs.com
- Korea
- Tel: +82-31-563-9873
- gvskorea@gvs.com
- Malaysia
- Tel: +60 3 7800 0062
- gvsmalaysia@gvs.com
- Thailand
- Tel: +66 2163 4310
- gvsthailand@gvs.com
Help us spread the word about respiratory protection.
Find more information at gvs-rpb.com
Copyright ©2024 GVS S.p.A. All rights reserved.
All materials contained in this publication are protected by United States
copyright law and may not be reproduced, distributed, transmitted, displayed,
published or
broadcast without the prior written permission of GVS S.p.A. You may not alter
or remove any trademark, copyright or other notice from copies of the content.
Trademarks and Other Intellectual Property
- All trademarks, service marks, and logos used in this publication, both registered and unregistered, are the trademarks, service marks, or logos of their respective owners.
- The green and gray color combination is a registered trademark of GVS S.p.A. All rights in the GVS-RPB Intellectual Property contained in this publication, including copyright, trademarks, service marks, trade secret, and patent rights are reserved. GVS-RPB
- Intellectual Property means any patent, patented articles, patent applications, designs, industrial designs, copyrights, software, source code, database rights, moral rights, inventions, techniques, technical data, trade secrets, know-how, brands, trademarks, trade names, slogans, logos, and any other common law and proprietary rights, whether registered or unregistered anywhere in the world, that are owned by, developed in whole or in part by, or licensed by GVS S.p.A.
- This Supplied Air Respirator How-To Guide serves as a general reference. All information provided has been compiled to the best of our knowledge. GVS does not bear any liability for the content in this brochure. It should be noted that the information and data contained within this brochure are subject to technical updates and may not always be current.
FAQ
I’d like to switch to GVS® respirators for my supplied air system, do I also have to change my existing gas monitor and filtration to GVS brand?
While it is ideal to have the same manufacturer support all parts of your supplied air system, there are no regulations indicating that is mandatory. It can be changed at a later date if desired.
answer-1=
Is there anything I would need to modify on my current gas monitor and/or filter to accommodate for GVS supplied air respirators?
Per NIOSH 1910.134(i)(8), the employer shall ensure that breathing air couplings are incompatible with outlets of non-respirable air and/or other gas systems. GVS provides non-common fittings for our respirators, such as the RPB® Quick Release, Schrader, and RZ Fitting. Our RPB Quick Release is our most commonly provided fitting. Most other manufacturers provide a common Hansen Industrial Quick Disconnect with their equipment, meaning GVS would need to supply our non-common RPB Quick Connect coupler to change on your existing gas monitor and/or filter.
answer-3=
I have existing supplied-air respirators and will be changing to GVS respirators, do I have to change the breathing air supply hose?
Yes. The National Institute for Occupational Safety and Health (NIOSH) issues certificates of approval for specific and complete respirator assemblies after the respirator has been evaluated and found to comply with all the requirements of the NIOSH regulations at Title 42, Code of Federal Regulations (CFR) Part 84 (42 CFR Part 84). As part of this approval, only GGVS-branded breathing air supply hoses are tested and approved for use with GVS respirators.
answer-5=
How many operators can I run off a Radex® Airline Filter?
If using a Radex for multiple operators, our 04-906 (6-0utlet) is recommended. This unit can accommodate up to 5 operators, depending on the particular flow control device being used with the respirator. However, it is recommended that with the use of the C40 or 4000 Series Cooling/Heating Tubes, only 3-4 operators should connect to accommodate the 25CFM required per operator for optimum performance.
Calibrations How-To and Who can do them?
While the gas sensors typically have a 2-year lifespan, a calibration check will need to be performed every 30-days. This can be done by the customer or outsourced through a distributor that offers the service. The calibration gas and regulator can be purchased for yourself, as seen on page 11. Review the GX4® instruction manual for additional details.
Do you have to purchase a GX4 for every Radex purchased?
Best practice is to have a GX4 for each Radex for audible and visible alarm notification purposes. However, it can be determined by the compressed air source, does your facility have a single or multiple compressors providing the breathing air to operators? Also, are the areas requiring breathing air near each other? For example, if a single air compressor ran to a blast booth and paint booth that are in the same building side by side, you could use only one GX4 Gas Monitor with a Remote Strobe Alarm, placing the remote strobe alarm in an area that can be seen and heard by all operators. Each remote strobe alarm is provided with a 50’ cable to be run into a shared notification area or a supervisor area.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>