HANNA Instruments pH502 pH Digital Controllers Owner’s Manual

August 22, 2024
HANNA instruments

HANNA Instruments pH502 pH Digital Controllers

pH Digital Controllers with Matching Pin and PID Control

  • CAL Check™
    Alerts users of calibration status

  • ATC
    Automatic temperature compensation

  • 3 Point Calibration
    Up to three point calibration

The pH502 series of controllers offer many features to increase the level of control available in your plant. These instruments can be configured to utilize P, PI, PID controlling. With this feature, the pH502 takes the place of three instruments that only allow one configuration each. The pH502 line includes models that incorporate control through analog output to drive any compatible device, such as an electrovalve or pump. The solid state relay is available to ensure maximum life of the switching device. Each model has a differential input for a grounding bar to extend electrode life.
Fail Safe Alarm System protects against power interruption or line failure. 1, 2 or 3 point automatic calibration and manual or Automatic Temperature Compensation complete the features of this controller.

Specifications

Specifications pH502
Range 0.00 to 14.00 pH; -9.9 to 120°C
Resolution 0.01 pH; 0.1°C
Accuracy (@25°C/77°F) ±0.02 pH; ±0.5°C
Input Impedance 1012 Ohm
pH Calibration automatic, one, two or three point, at pH 4.01, 7.01, 10.01
Temperature Compensation automatic (with Pt100 probe) or manual from -9.9 to

120°C
Outputs| digital: RS485 bi-directional optoisolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC

Set Point Relay

| 1 or 2 contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load) or 1 or 2 Solid State Relay (SSR), 1A, 250 VAC (resistive and inductive load), fuse protected (2A, 250V fast fuse)
Alarm Relay| one contact output SPDT, 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (5A, 250V fuse)
Power Supply| 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Power Consumption| 15 VA
Over Current Protection| 400 mA 250V fast fuse
Environment| 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions| panel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm
Weight| 1.6 kg (3.5 lb.)

Ordering Information

| Each pH 502 model is supplied complete with mounting brackets and instructions

Choose your configuration

pH502421-1 Dual setpoint with SSR relay, on/off and PID controls, analog output, 115V

pH502421-2 Dual setpoint with SSR relay, on/off and PID controls, analog output, 230V

Line ID: @neonics

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HANNA instruments User Manuals

Related Manuals