xpr WS4-2D-E 2-Door Access Control Unit User Guide
- August 22, 2024
- xpr
Table of Contents
xpr WS4-2D-E 2-Door Access Control Unit
FAQ
Q: How can I find out the IP address of the WS4-2D-E controller if my network does not recognize it?
A: You can download the Device Finder tool from our website and run it to discover the IP address of the controller connected in your network.
DESCRIPTION
WS4-2D-E is a 2-door control unit designed to operate over readers with RS-485
line.
WS4 is a completely autonomous device, operating without additional software
or hardware. Any device with web browser can be used for management of the WS4
system.
SPECIFICATIONS
- Capacity: 2500 Users
- Events: 50,000 max.
- Doors: 2 (max. 40 doors in same network)
- Readers: 2
- Door contact inputs: 2
- Push button inputs: 2
- Auxiliary Inputs: 2 (emergency, vehicle detection)
- Auxiliary Outputs: 3 (alarm, storing alarm status, presence)
- Power supply: 15 V DC/5 A
- Supply for the readers: 250 mA each max.
- Supply for the locks: 600 mA each max.
- Relay characteristics: 2 A/48 V AC/DC
- Processor: ARM A5 – 528 MHz
- Memory: 64 MB RAM DDR2 133 MHz
- TCP/IP connection: 10/100/1000 Base-T – HTTP or HTTPS
- Operating temperature: 0 °C to +50 °C
- Humidity: 0% to 85% (non-condensing)
- Tamper: Yes
- Wiegand readers connection: Yes, via Wiegand to RS-485 converter – WS4-CNV
- Elevator feature: Yes, 2 elevators per installation, each – 24 floors
- Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
- System limits of max 40 doors and 15 controllers (1 master + 14 slaves).
- Activate AUX OUT Relay when first person enters and last person leaves (Attendance).
- Minimum password length of 8 characters.
- The WS4 automatically creates an internal backup on USB memory stick at 23:00 only
if the programming has been changed. A maximum of 15 backups are retained.
FIRST CONNECTION AND CONFIGURATION
The WS4-2D-E does not have default IP address. By default is set to DHCP. There are 2 methods to connect to and configure WS4-2D-E – LAN and Standalone method.
METHOD 1
(For use in a home or business LAN network)
In this configuration, the network’s DHCP server will assign an IP address to your WS4-2D-E
- Put the DIP switch 1 in position OFF.
- Connect a cable from your network to the ethernet connector of WS4-2D-E.
- Open a web browser and enter http://ws4 followed dash and the serial number of the WS4-2D-E controller.
If you cannot connect, your network does not recognize the name of the
WS4-2D-E controller. In this case, go to our web site
http://www.xprgroup.com/ products/ws4/ and download the tool “Device
Finder”.
“Device Finder” will enable you to find out the IP address of the WS4-2D-E
controller.
Run the “Device Finder” and you will get a list of all the WS4 controllers
connected in your network, including their IP addresses, as the picture below.
Open a browser and type the IP of the WS4- 2D-E controller and you will be
prompted to the
login page.
User Name: admin
Password: WS4 followed by Dash and the Serial Number (e.g., WS4-110034) just
like the image below, all in capital letters without space.
METHOD 2 (For standalone use – without LAN network)
In this configuration, the WS4-2D-E will assign an IP address to your PC. The PC must be set to obtain IP address automatically.
- Put the DIP switch 1 in position ON.
- Connect a cable from your PC directly to the ethernet connector of WS4-2D-E.
- Open a web browser and enter the following IP – 192.168.50.100, then put the login credentials as explained above.
FACTORY RESET
To do this, take the following steps:
- Put DIP Switch 4 (Factory reset) to ON position.
- Wait for the blinking green LED (COMM).
- Consecutively switch the Factory reset switch (DIP 1) 3 times in the following combination OFF – ON – OFF within 10 seconds.
- Next, the green LED starts blinking very fast, initializes it and the factory default is completed.
CHANGE PASSWORD
DIP Switch 1 allows to log into the system as an administrator if login or password is forgotten.
- Put DIP Switch 2 (Factory reset) to ON position.
- Wait for the blinking green LED (COMM).
- Consecutively switch the Factory reset switch (DIP 1) 3 times in the following combination OFF – ON – OFF within 10 seconds.
- Next, the green LED starts blinking very fast, initializes it and the factory default is completed.
SYSTEM SETUP
ADDING READERS
Go to “Doors”, select the reader (Fig. 2) and then select the type of the reader in the field ”Card”. (Fig. 3). While offline, red LED blinks fast and buzzer beeps continuously. Once communication is established, the red LED and the buzzer stop. Green LED starts to blink continuously. If you want to stop the green LED, go to Settings/System Options and select the backlight ON or OFF (not default) (Fig. 4).
To add 2 readers on 1 Door, select the reader (Fig. 2) and there, for “Type of Access” select “Access with 2 readers” (Fig. 5). Access with 2 readers is only available for doors 1.0 and 2.0, provided that a single door is not already configured in 1.1 or 2.1 respectively (Fig. 6).
ADDING USERS
Go to Users (Fig. 1), select “New” (Fig. 2) and then fill the form (Name, Category, Card Number…) (Fig. 3).
ADDING SLAVE CONTROLLERS
- One system can have up to 15 WS4 controllers (any model) and control up to 40 doors.
- One WS4-2D must be master, the others must be slaves. The master/slave selection is made with DIP-switch 2: OFF – Master (factory setting), ON – Slave.
- Go to “Doors” and click on the link “Add a slave” (Fig. 1). Enter the serial number of the WS4-2D-E to be added and click Search. If it finds it, the system directly adds this slave into the installation and you can configure its doors (Fig. 2).
- In case of error, a message is displayed in red.
Connection example of 2 doors
-
The readers for Door 1.0 must be at address 0 and those for Door 1.1 at address 1
-
For doors equipped with 2 readers, one must be at address 0 and the other at address 1
-
The function of OUT1, OUT2 and OUT3 can be configured in the software
-
In1 & In2: Connect to GND to activate the input
-
LIYCY cable, twisted pair, up to 80 m
If more than 80 m are needed, then termination resistors (120 ohm) may be required at both ends of the RS-485 line, while taking into consideration the lengths proposed on our web site -
Alarm cable 2×0.22
-
The cross section of the cable depends on the current needed by the lock
Note: The elevators relay boards (WS4-RB-12) are connected on the same RS-485 lines as the readers.
This product herewith complies with the requirements of EMC directive
2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive
2015/863/EU.