Specifications:

  • Cooling Efficiency: Up to 16 SEER / 13 EER
  • Nominal Sizes: 1.5 to 5 Ton [5.28 to 17.6 kW]
  • Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]
  • Refrigerant: R-410A
  • Voltage: 208/230V – 1 Phase – 60 Hz

Product Usage Instructions

Installation:

  1. Ensure proper sizing and installation of the air conditioner for optimal performance.
  2. Match the split system air conditioner with appropriate coil components to meet Energy Star requirements.
  3. Refer to the manual or visit www.energystar.gov for more details.

Standard Equipment:

  • R-410A Refrigerant
  • Scroll Compressor
  • Field Installed Filter Drier
  • Front Seating Service Valves
  • Internal Pressure Relief Valve
  • Internal Thermal Overload
  • Long Line capability
  • Low Ambient capability with Kit
  • Composite Basepan
  • 2 Screw Control Box Access
  • Optimized Venturi Airflow
  • Powder coated paint
  • Rust resistant screws
  • External gauge ports
  • Service trays

General Data/Electrical Data:

Model No. Nominal Tonnage Valve Connections Motor hp CFM RPM Watts

Line Voltage Data:

  • 208/230V-1-60 for all models

FAQ:

  • Q: How do I ensure optimal performance of my VantixTM Line iM Air Conditioner?
    A: Proper sizing and installation are crucial. Make sure to match the air conditioner with appropriate coil components and refer to Energy Star guidelines.

  • Q: What is the refrigerant used in the SA14AZ Air Conditioners?
    A: The SA14AZ Air Conditioners use R-410A refrigerant.

  • Q: Where can I find more information about Energy Star requirements?
    A: For more details on Energy Star requirements, you can visit www.energystar.gov.

SA14AZ

  • Cooling Efficiency up to 16 SEER2/13 EER2
  • Nominal Sizes: 11/2 to 5 Ton [5.28 to 17.6 kW]
  • Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]

= A.F.U.E. (Annual Fuel Utilization Efficiency) calculated under Department of Energy test procedures.

Proper sizing and installation of equipment are critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Features and Benefits

  • Lighter Footprint & Less Environmental Impact from New 7mm Condenser Coil: Provided by a decrease in refrigerant requirements and an overall weight reduction
  • Efficient Cooling: Up to 16 SEER2/13 EER2
  • Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space – provides a minimum working area of 27 square inches for easier access
  • Triple Service Access: 15 in. wide, industry-leading corner service access – makes repairs easier and faster
  • System Matching Simplicity: Matches to all tiers of gas furnaces
  • Modern Cabinet Aesthetics: High curb appeal with visually appealing design
  • Diagnostic Service Window: With two-fastener opening –provides access to the high and low pressure
  • External Gauge Port Access: Allows easy connection of “low-loss” gauge ports
  • QR Code: Provides technical information on demand for faster service calls
  • Fan Motor Harness: With extra-long wires allow the unit top to be removed without disconnecting the fan wire

Model Number Identification

SA14AZ

Designates Metric Conversions

AVAILABLE MODELS DESCRIPTION
SA14AZ18AJ1NA Vantix™ Line 1 1/2 ton 14.3 SEER2 Single-Stage iM Air

Conditioner-208/230/1/60
SA14AZ18AJ1NALHP| Vantix™ Line 1 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ24AJ1NA| Vantix™ Line 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ24AJ1NALHP| Vantix™ Line 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ30AJ1NA| Vantix™ Line 2 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ30AJ1NALHP| Vantix™ Line 2 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ36AJ1NA| Vantix™ Line 3 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ36AJ1NALHP| Vantix™ Line 3 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ42AJ1NA| Vantix™ Line 3 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ42AJ1NALHP| Vantix™ Line 3 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ48AJ1NA| Vantix™ Line 4 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ48AJ1NALHP| Vantix™ Line 4 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
SA14AZ60AJ1NA| Vantix™ Line 5 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
SA14AZ60AJ1NALHP| Vantix™ Line 5 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
STANDARD EQUIPMENT

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
No fasteners to remove along the bottom
Optimized Venturi Airflow
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

General Data/Electrical Data

General Data

MODEL NO.| SA14AZ18| SA14AZ24| SA14AZ30| SA14AZ36| SA14AZ42| SA14AZ48| SA14AZ60
Nominal Tonnage| 1.5| 2.0| 2.5| 3.0| 3.5| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 3/4| 3/4| 7/8| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 94| 115| 120| 124| 149| 153| 203
Compressor Type| Scroll
Outdoor Coil|
Net face area – Outer Coil| 10.9| 13.3| 14.3| 16.4| 19.5| 19.5| 32.5
Net face area – Inner Coil| 10.5| 12.9| 13.9| 15.9| 18.8| 18.8| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276| 0.276| 0.276| 0.375
Number of rows| 2| 2| 2| 2| 2| 2| 1
Fins per inch| 24| 24| 24| 24| 24| 24| 22
Outdoor Fan|
Diameter – in.| 20| 24| 24| 24| 24| 24| 26
Number of blades| 2| 2| 2| 2| 3| 3| 3
Motor hp| 1/7| 1/6| 1/6| 1/6| 1/5| 1/5| 1/3
CFM| 2156| 2723| 2830| 2991| 3655| 3655| 5178
RPM| 1075| 825| 825| 825| 850| 850| 910
Watts| 152| 161| 165| 145| 214| 214| 271
Shipping weight lbs.| 151| 185| 197| 217| 259| 250| 294
Operating weight lbs.| 144| 178| 190| 210| 252| 243| 287
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 25| 30| 30| 40| 40| 60
Minimum circuit ampacity³| 14| 18| 19| 20| 24| 24| 40
Compressor|
Rated load amps| 9| 12| 14| 13| 18| 18| 26
Locked rotor amps| 43| 60| 68| 83| 110| 102| 150
Condenser Fan Motor|
Full load amps| 0.8| 0.8| 0.8| 0.8| 1.0| 1.0| 2.8
Locked rotor amps| 1.5| 1.5| 1.7| 1.7| 2.6| 2.6| —

  1. Refrigerant charge is sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
    refrigerant charge required.

  2. HACR type circuit breaker of the fuse.

  3. Refer to the National Electrical Code manual to determine wire, fuse, and disconnect size requirements.

Accessories

MODEL NO.| SA14AZ18| SA14AZ24| SA14AZ30| SA14AZ36| SA14AZ42| SA14AZ48| SA14AZ60
---|---|---|---|---|---|---|---
Compressor crankcase heater*| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-45| 44-17402-45| 44-17402-45
Low ambient control| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08
Compressor sound cover| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-25| 68-23427-25| 68-23427-25
Compressor hard start kit| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1
Compressor time delay| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01
Low pressure control| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07
High pressure control| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Classic Top Cap w/Label| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21

Crankcase Heater recommended with Low Ambient Kit.

Weighted Sound Power

Weighted Sound Power Level (dBA)

UNIT SIZE– VOLTAGE, SERIES| STANDARD RATING (DBA)| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
SA14AZ18| 70.7| 48.2| 56.0| 61.9| 61.0| 56.5| 53.5| 45.7
SA14AZ24| 68.5| 44.6| 53.6| 58.7| 58.0| 55.5| 50.5| 45.7
SA14AZ30| 70.8| 45.1| 54.5| 59.8| 59.0| 56.8| 53.8| 45.9
SA14AZ36| 71.6| 45.4| 52.6| 60.2| 60.8| 58.7| 55.9| 48.4
SA14AZ42| 72.5| 46.6| 55.3| 63.9| 62.1| 59.4| 55.2| 48.2
SA14AZ48| 74.0| 45.4| 55.7| 64.2| 62.9| 60.8| 56.7| 51.2
SA14AZ60| 75.8| 43.4| 59.8| 67.2| 65.5| 62.7| 59.2| 53.1

NOTE: Tested by AHRI Standard 270-08 (not listed in AHRI).

Unit Dimensions


MODEL NO.

| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm
SA14AZ18| 25.00| 635| 29.75| 756| 29.75| 756| 26.50| 673| 32.38| 822| 32.38| 822
SA14AZ24| 25.00| 635| 33.75| 857| 33.75| 857| 26.50| 673| 36.38| 924| 36.38| 924
SA14AZ30| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
SA14AZ36| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924| 36.38| 924
SA14AZ42| 35.00| 889| 33.75| 857| 33.75| 857| 36.50| 927| 36.38| 924| 36.38| 924
SA14AZ48| 35.00| 889| 33.75| 857| 33.75| 857| 36.50| 927| 36.38| 924| 36.38| 924
SA14AZ60| 51.00| 1295| 35.75| 908| 35.75| 908| 52.50| 1334| 38.38| 975| 38.38| 975

Designates Metric Conversions

CLEARANCES

NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re- circulation of discharge air.

Refrigerant Line Size Information

14.3 SEER2 SINGLE-STAGE AIR CONDITIONERS


UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

| ****

ALLOWABLE SUCTION LINE SIZE

| APPLY LONG LINE GUIDELINES IF LINEAR LINE LENGTH EXCEEDS THOSE SHOWN BELOW (FEET)| EQUIVALENT LENGTH (FEET)
< 25| 26- 50| 51- 75| 76- 100| 101- 125| 126- 150| 151- 175| 176- 200| 201- 225| 226- 250
(- )A14AZ| MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT) *** / CAPACITY MULTIPLIER**



1.5 Ton

**SEE NOTE 3

| 1/4″| 5/8″| N/A| 25 / 1.00| 50 / 0.99| 62 / 0.98| 43 / 0.98| 24 / 0.97| 5 / 0.97| NR| NR| NR| NR
5/16″| 5/8″| 223| 25 / 1.00| 50 / 0.99| 75 / 0.98| 98 / 0.98| 93 / 0.97| 88 / 0.97| 83 / 0.96| 78 / 0.96| 73 / 0.95| 68 / 0.94
3/8″| 5/8″| 148| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 100 / 0.95| 100 / 0.94
1/4″| 3/4″| N/A| 25 / 1.00| 50 / 1.00| 62 / 0.99| 43 / 0.99| 24 / 0.99| 5 / 0.99| NR| NR| NR| NR
5/16″| 3/4″
| 223| 25 / 1.00| 50 / 1.00| 75 / 0.99| 98 / 0.99| 93 / 0.99| 88 / 0.99| 83 / 0.99| 78 / 0.98| 73 / 0.98| 68 / 0.98
3/8″| 3/4″**| 148| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98




2 Ton

| 1/4″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 21 / 0.97| NR| NR| NR| NR| NR| NR| NR
5/16″| 5/8″| 213| 25 / 0.99| 50 / 0.98| 75 / 0.97| 87 / 0.96| 77 / 0.95| 69 / 0.94| 61 / 0.93| 53 / 0.92| 45 / 0.91| 37 / 0.90
3/8″| 5/8″| 142| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 98 / 0.93| 95 / 0.92| 92 / 0.91| 89 / 0.90
1/4″| 3/4″| N/A| 25 /1.00| 50 / 1.00| 21 / 0.99| NR| NR| NR| NR| NR| NR| NR
5/16″| 3/4″| 213| 25 /1.00| 50 / 1.00| 75 / 0.99| 87 / 0.99| 77 / 0.98| 69 / 0.98| 61 / 0.98| 53 / 0.97| 45 / 0.97| 37 / 0.96
3/8″| 3/4″| 142| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 98 / 0.98| 95 / 0.97| 93 / 0.97| 90 / 0.96



2.5 Ton

| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 75 / 0.96| 70 / 0.94| 59 / 0.93| 48 / 0.91| 36 / 0.90| NR| NR| NR
3/8″| 5/8″| 117| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.94| 98 / 0.93| 94 / 0.91| 90 / 0.90| NR| NR| NR
5/16″| 3/4″| 175| 25 / 1.00| 50 / 0.99| 75 / 0.99| 70 / 0.98| 59 / 0.98| 48 / 0.97| 36 / 0.96| 25 / 0.96| 13 / 0.95| NR
3/8″| 3/4″| 117| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 98 / 0.98| 94 / 0.97| 90 / 0.96| 86 / 0.96| 82 / 0.95| 78 / 0.95





3 Ton

| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.97| 66 / 0.94| 49 / 0.92| 32 / 0.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 85| 25 / 0.99| 50 / 0.97| 75 / 0.94| 95 / 0.92| 89 / 0.90| NR| NR| NR| NR| NR
5/16″| 3/4″| 128| 25 / 1.00| 50 / 0.99| 66 / 0.98| 49 / 0.98| 32 / 0.97| 15 / 0.96| NR| NR| NR| NR
3/8″| 3/4″| 85| 25 / 1.00| 50 / 0.99| 75 / 0.98| 95 / 0.98| 89 / 0.97| 84 / 0.96| 78 / 0.95| 72 / 0.94| 67 / 0.93| 61 / 0.93
1/2″| 3/4″| 43| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.93| 100 / 0.93
5/16″| 7/8″| 128| 25 / 1.00| 50 / 1.00| 66 / 1.00| 49 / 0.99| 32 / 0.99| 15 / 0.99| NR| NR| NR| NR
3/8″| 7/8″| 85| 25 / 1.00| 50 / 1.00| 75 / 1.00| 95 / 0.99| 89 / 0.99| 84 / 0.99| 78 / 0.98| 72 / 0.98| 67 / 0.98| 61 / 0.97
1/2″| 7/8″| 43| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98| 100 / 0.97



3.5 Ton

| 3/8″| 3/4″| 102| 25 / 0.99| 50 / 0.98| 75 / 0.97| 88 / 0.96| 80 / 0.95| 72 / 0.94| 65 / 0.92| 57 / 0.91| 49 / 0.90| NR
1/2″| 3/4″| 51| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.92| 100 / 0.91| 100 / 0.90| NR
3/8″| 7/8″| 102| 25 / 1.00| 50 / 1.00| 75 / 0.99| 88 / 0.99| 80 / 0.99| 72 / 0.98| 65 / 0.97| 57 / 0.97| 49 / 0.96| 42 / 0.96
1/2″| 7/8″| 51| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96

NOTES:

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. **A 3/4″ suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to ensure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

14.3 SEER2 SINGLE-STAGE AIR CONDITIONERS


UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

| ****

ALLOWABLE SUCTION LINE SIZE

| APPLY LONG LINE GUIDELINES IF LINEAR LINE LENGTH EXCEEDS THOSE SHOWN BELOW (FEET)| EQUIVALENT LENGTH (FEET)
< 25| 26- 50| 51- 75| 76- 100| 101- 125| 126- 150| 151- 175| 176- 200| 201- 225| 226- 250
(- )A14AZ| MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT) *** / CAPACITY MULTIPLIER**




4 Ton

| 3/8″| 3/4″| 110| 25 / 0.99| 50 / 0.98| 75 / 0.96| 77 / 0.95| 67 / 0.93| 57 / 0.92| 46 / 0.91| NR| NR| NR
1/2″| 3/4″| 55| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.95| 100 / 0.93| 100 / 0.92| 100 / 0.91| NR| NR| NR
3/8″| 7/8″| 110| 25 / 1.00| 50 / 0.99| 75 / 0.99| 77 / 0.98| 67 / 0.97| 57 / 0.97| 46 / 0.96| 36 / 0.96| 26 / 0.95| 15 / 0.95
1/2″| 7/8″| 55| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 99 / 0.95| 97 / 0.95
3/8″| 3/4″| 0| 25 / 0.99| 50 / 0.97| 75 / 0.94| 61 / 0.92| 46 / 0.90| NR| NR| NR| NR| NR
1/2″| 3/4″| 0| 25 / 0.99| 50 / 0.97| 75 / 0.94| 100 / 0.92| 100 / 0.90| NR| NR| NR| NR| NR



5 Ton

| 3/8″| 7/8″| 0| 25 / 1.00| 50 / 0.99| 75 / 0.98| 61 / 0.97| 46 / 0.96| 32 / 0.95| 18 / 0.94| NR| NR| NR
1/2″| 7/8″| 0| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.97| 100 /0.96| 100 / 0.95| 97 / 0.94| 95 / 0.94| 92 / 0.93| 89 / 0.92
3/8″| 1-1/8″| 0| 25 / 1.01| 50 / 1.01| 75 / 1.00| 61 / 1.00| 46 / 0.99| 32 / 0.99| 18 / 0.99| NR| NR| NR
1/2″| 1-1/8″| 0| 25 / 1.01| 50 / 1.01| 75 / 1.00| 100 /1.00| 100 / 0.99| 100 / 0.99| 97 / 0.99| 95 / 0.99| 92 / 0.99| 89 / 0.98

NOTES:

  1. Do not exceed 200 ft linear line length.
  2. *Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

14.3 SEER2 SINGLE-STAGE AIR CONDITIONERS


UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

MM [IN.]

| ****

ALLOWABLE SUCTION LINE SIZE

MM [IN.]

| APPLY LONG LINE GUIDELINES IF LINEAR LINE LENGTH EXCEEDS THOSE SHOWN BELOW (METERS)| EQUIVALENT LENGTH (METERS)
< **8| 8- 15| 16- 23| 24- 30| 31- 38| 39- 46| 47- 53| 54- 61| 62- 69| 70- 76
(- )A14AZ| MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT)** *** / CAPACITY MULTIPLIER**


5.3 KW [1.5 Ton]

**SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 1.00| 15 / 0.99| 19 / 0.98| 13 / 0.98| 7 / 0.97| 2 / 0.97| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| 68| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 28 / 0.97| 27 / 0.97| 25 / 0.96| 24 / 0.96| 22 / 0.95| 21 / 0.94
9.53 [3/8]| 15.88 [5/8]| 45| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96| 30 / 0.95| 30 / 0.94
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 19 / 0.99| 13 / 0.99| 7 / 0.99| 2 / 0.99| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 68| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 28 / 0.99| 27 / 0.99| 25 / 0.99| 24 / 0.98| 22 / 0.98| 21 / 0.98
9.53 [3/8]| 19.05 [3/4]**| 45| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98



7.0 KW [2 Ton]

| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 6 / 0.97| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| 59| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 23 / 0.95| 21 / 0.94| 19 / 0.93| 16 / 0.92| 14 / 0.91| 11 / 0.90
9.53 [3/8]| 15.88 [5/8]| 39| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 29 / 0.92| 28 / 0.91| 27 / 0.90
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 6 / 0.99| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 59| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 23 / 0.98| 21 / 0.98| 19 / 0.98| 16 / 0.97| 14 / 0.97| 11 / 0.96
9.53 [3/8]| 19.05 [3/4]| 39| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 29 / 0.97| 28 / 0.97| 27 / 0.96


8.8 KW [2.5 Ton]

| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 23 / 0.96| 21 / 0.94| 18 / 0.93| 15 / 0.91| 11 / 0.90| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 36| 8 / 0.99| 15 / 0.98| 23 / 0.96| 30 / 0.94| 30 / 0.93| 29 / 0.91| 27 / 0.90| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 53| 8 / 1.00| 15 / 0.99| 23 / 0.99| 21 / 0.98| 18 / 0.98| 15 / 0.97| 11 / 0.96| 8 / 0.96| 4 / 0.95| NR
9.53 [3/8]| 19.05 [3/4]| 36| 8 / 1.00| 15 / 0.99| 23 / 0.99| 30 / 0.98| 30 / 0.98| 29 / 0.97| 27 / 0.96| 26 / 0.96| 25 / 0.95| 24 / 0.95





10.6 KW [3 Ton]

| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.97| 20 / 0.94| 15 / 0.92| 10 / 0.90| NR| NR| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 26| 8 / 0.99| 15 / 0.97| 23 / 0.94| 29 / 0.92| 27 / 0.90| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 39| 8 / 1.00| 15 / 0.99| 20 / 0.98| 15 / 0.98| 10 / 0.97| 5 / 0.96| NR| NR| NR| NR
9.53 [3/8]| 19.05 [3/4]| 26| 8 / 1.00| 15 / 0.99| 23 / 0.98| 29 / 0.98| 27 / 0.97| 26 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.93| 19 / 0.93
12.70 [1/2]| 19.05 [3/4]| 13| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 30 / 0.93
7.94 [5/16]| 22.23 [7/8]| 39| 8 / 1.00| 15 / 1.00| 20 / 1.00| 15 / 0.99| 10 / 0.99| 5 / 0.99| NR| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 26| 8 / 1.00| 15 / 1.00| 23 / 1.00| 29 / 0.99| 27 / 0.99| 26 / 0.99| 24 / 0.98| 22 / 0.98| 20 / 0.98| 19 / 0.97
12.70 [1/2]| 22.23 [7/8]| 13| 8 / 1.00| 15 / 1.00| 23 / 1.00| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 30 / 0.97


12.3 KW [3.5 Ton]

| 9.53 [3/8]| 19.05 [3/4]| 31| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.92| 17 / 0.91| 15 / 0.90| NR
12.70 [1/2]| 19.05 [3/4]| 15| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.92| 30 / 0.91| 30 / 0.90| NR
9.53 [3/8]| 22.23 [7/8]| 31| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 24 / 0.99| 22 / 0.98| 20 / 0.97| 17 / 0.97| 15 / 0.96| 13 / 0.96
12.70 [1/2]| 22.23 [7/8]| 15| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96

NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if the outdoor unit is above the indoor unit.
  3. **A 19.05mm suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to ensure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

14.3 SEER2 SINGLE-STAGE AIR CONDITIONERS



UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

MM [IN.]

| ****

ALLOWABLE SUCTION LINE SIZE

MM [IN.]

| APPLY LONG LINE GUIDELINES IF LINEAR LINE LENGTH EXCEEDS THOSE SHOWN BELOW (METERS)| EQUIVALENT LENGTH (METERS)
< 25| 26- 50| 51- 75| 76- 100| 101- 125| 126- 150| 151- 175| 176- 200| 201- 225| 226- 250
(- )A14AZ| MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT) *** / CAPACITY MULTIPLIER**



14.1 KW [4 Ton]

| 9.53 [3/8]| 19.05 [3/4]| 34| 8 / 0.99| 15 / 0.98| 23 / 0.96| 24 / 0.95| 20 / 0.93| 17 / 0.92| 14 / 0.91| NR| NR| NR
12.7 [1/2]| 19.05 [3/4]| 17| 8 / 0.99| 15 / 0.98| 23 / 0.96| 30 / 0.95| 30 / 0.93| 30 / 0.92| 30 / 0.91| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 34| 8 / 1.00| 15 / 0.99| 23 / 0.99| 24 / 0.98| 20 / 0.97| 17 / 0.97| 14 / 0.96| 11 / 0.96| 8 / 0.95| 5 / 0.95
12.7 [1/2]| 22.23 [7/8]| 17| 8 / 1.00| 15 / 0.99| 23 / 0.99| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96| 30 / 0.95| 30 / 0.95
9.53 [3/8]| 19.05 [3/4]| 0| 8 / 0.99| 15 / 0.97| 23 / 0.94| 19 / 0.92| 14 / 0.90| NR| NR| NR| NR| NR
12.7 [1/2]| 19.05 [3/4]| 0| 8 / 0.99| 15 / 0.97| 23 / 0.94| 30 / 0.92| 30 / 0.90| NR| NR| NR| NR| NR


17.6 KW [5 Ton]

| 9.53 [3/8]| 22.23 [7/8]| 0| 8 / 1.00| 15 / 0.99| 23 / 0.98| 19 / 0.97| 14 / 0.96| 10 / 0.95| 5 / 0.94| NR| NR| NR
12.7 [1/2]| 22.23 [7/8]| 0| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.97| 30 /0.96| 30 / 0.95| 30 / 0.94| 29 / 0.94| 28 / 0.93| 27 / 0.92
9.53 [3/8]| 28.58 [1-1/8]| 0| 8 / 1.01| 15 / 1.01| 23 / 1.00| 19 / 1.00| 14 / 0.99| 10 / 0.99| 5 / 0.99| NR| NR| NR
12.7 [1/2]| 28.58 [1-1/8]| 0| 8 / 1.01| 15 / 1.01| 23 / 1.00| 30 / 1.00| 30 / 0.99| 30 / 0.99| 30 / 0.99| 29 / 0.99| 28 / 0.99| 27 / 0.98

NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if the outdoor unit is above the indoor unit.
  3. **19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data

Performance Data @ AHRI Standard Conditions – Cooling

DESIGNATED TESTED COMBINATION (DTC)

OUTDOOR UNIT| INDOOR COIL| TOTAL CAPACITY BTU/H [KW]| NET SENSIBLE BTU/H [KW]| NET LATENT BTU/H [KW]| SEER2| EER2| INDOOR CFM [L/s]
SA14AZ18AJ1| RCFZ2417STAN| 17,100 [5.0]| 13,100 [3.8]| 4,000 [1.2]| 14.3| 11.7| 600 [283.2]
SA14AZ24AJ1| RCFZ2417STAN| 22,800 [6.7]| 17,500 [5.1]| 5,300 [1.6]| 14.3| 11.7| 725 [342.2]
SA14AZ30AJ1| RCFZ3617STAN| 28,600 [8.4]| 21,800 [6.4]| 6,800 [2.0]| 14.3| 11.7| 900 [424.8]
SA14AZ36AJ1| RCFZ3617STAN| 34,200 [10.0]| 26,200 [7.7]| 8,000 [2.3]| 14.3| 11.7| 1,025 [483.7]
SA14AZ42AJ1| RCFZ4821STAN| 38,500 [11.3]| 29,500 [8.6]| 9,000 [2.6]| 14.3| 11.7| 1,300 [613.5]
SA14AZ48AJ1| RCFZ4821STAN| 45,000 [13.2]| 34,500 [10.1]| 10,500 [3.1]| 13.8| 11.2| 1,425 [672.5]
SA14AZ60AJ1| RCFZ6024STAN| 56,000 [16.4]| 42,900 [12.6]| 13,100 [3.8]| 13.8| 11.2| 1,600 [755.1]

NOTE:
This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match- ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

LIMITED WARRANTY

GENERAL TERMS OF LIMITED WARRANTY
Russell® By Rheem will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, under the terms of the limited warranty.

For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Parts
(Registration Required) ……………………………Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

© 2024 Rheem Manufacturing Company. Russell By Rheem trademarks are owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Russell by Rheem reserves the right to make changes without notice.

5600 Old Greenwood Road Fort Smith, Arkansas 72908 • www.russellbyrheem.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals