KPS MS922D AC Line Splitter Owner’s Manual

August 21, 2024
KPS

KPS MS922D AC Line Splitter

Specifications

  • Humidity: 90%
  • Dimensions: 2005748mm
  • Weight: approx. 140g
  • Accessories: User’s manual

Product Usage Instructions

Safety Information

Users must read and follow all safety instructions before using this unit to prevent personal injury or unit damage.

  1. Check for damage to the unit or insulation.
  2. Ensure input does not exceed AC 250V, 15A to avoid electrical shock.
  3. Avoid opening the back cover to prevent damage to insulation.
  4. Turn off power before removing test leads from voltage test jacks.

Safety Symbols

  • Important safety information: refer to the user’s manual
  • Dangerous voltage may be present
  • Double insulation
  • Earth ground
  • Live wire connection for voltage test
  • Neutral wire connection for voltage test

Front panel description

  1. Power plug: Standard plug with overload protection (AC 250V, 15A)
  2. X1   current terminal: Tests actual working current
  3. X10 current terminal: Tests working current x10
  4. Voltage test input sockets: Insert test leads for voltage measurement
  5. Input socket: Maximum input AC 250V, 15A

Operating Instructions

  1. Connect the power plug to an outlet.
  2. Plug the device into the input socket.
  3. Use a clamp meter to measure the desired current terminal.

Voltage Testing

  1. Connect the power plug to an outlet.
  2. Plug the device into the input socket.
  3. Connect the test leads of the multimeter to voltage test sockets and measure voltage in AC mode.

Power Testing

  1. Connect the power plug to an outlet.
  2. Plug the device into the input socket.
  3. Connect the test leads of the multimeter to voltage test sockets and measure voltage in AC mode.
  4. Use a clamp meter to measure the desired current terminal for the calculation of power.

Frequently Asked Questions

Q: What should I do if I encounter a dangerous voltage situation?

A: Refer to the user’s manual for important safety information and take necessary precautions such as using appropriate safety gear and contacting a professional if needed.

Q: How do I know which current terminal to use for measurement?

A: The X1 terminal is for normal current load, while the X10 terminal is for measuring current at ten times the normal load. Choose based on your measurement requirements.

SAFETY INFORMATION

Users must read and follow all safety instructions before using this unit to prevent personal injury or damage to the unit.

  1. Please check that there is no damage to the unit or insulation.
  2. Input should not exceed more than AC 250V, 15A to avoid electrical shock or danger.
  3. Do not open the back cover to avoid damaging the insulation.
  4. Turn off power first before removing the test leads from the voltage test jacks.

GENERAL DESCRIPTION

This instrument is a special accessory for clamp meters which can be used to measure current conveniently without breaking the insulation on the equipment’s power line. It can also be used to test the equipment’s working voltage using a multimeter. it’s an essential tool for safely taking electrical measurements with little damage to the equipment under test. Its quality construction and easy-to-use design are built according to IEC61010 standards with an overvoltage category of CAT II 600V.

FEATURES

  1. Safety standard conforms to IEC61010
  2. Maximum input: AC 250V, 15A.
  3. Operating temperature: 0~40°C; Humidity: ≤90%
  4. Storage temperature: 10~50°C; Humidity: ≤90%
  5. Dimensions: 2005748mm
  6. Weight: approx. 140g
  7. Accessories: user’s manual

SAFETY SYMBOLS

FRONT PANEL

Front panel description

  1. Power plug:
    • This is a standard plug as shown below.
    • Overload protection: AC 250V, 15A
  2. X1” current terminal:
    • Tests actual working current.
  3. X10” current terminal:
    • Tests working current x10.
  4. Voltage test input sockets:
    • Insert test leads to measure voltage.
  5. Input socket:
    • Maximum input: AC 250V, 15A.
    • This socket is suitable for standard plug configuration.
    • This configuration is shown in the figure below.

OPERATING INSTRUCTIONS

Current Testing

Maximum input is  AC 250V, 15A.

  1. Connect the power plug to an outlet.
  2. Plug the device to be measured into the input socket.
  3. Use a clamp meter and clamp the desired current terminal of the line splitter for measurement
  • Each terminal of the splitter will give a different current reading.
  • X1 terminal for normal current load.
  • X10 terminal for 10 times the normal current load.
  • The error of the clamp meter itself will influence the testing degree of accuracy.

Voltage Testing

  1. Connect the power plug to an outlet.
  2. Plug the device to be measured into the input socket.
  3. Connect the test leads of your multimeter to the voltage test sockets and put the meter in AC voltage mode to measure the voltage of the connected device.

Power Testing

  1. Connect the power plug to an outlet.
  2. Plug the device to be measured into the input socket.
  3. Connect the test leads of your multimeter to the voltage test sockets and put the meter in AC voltage mode to measure the voltage of the connected device.
  4. Use a clamp meter and clamp the desired current terminal of the line splitter for measurement.
  5. Calculate the power of the connected device using the following formula.
    • Power = voltage x current
  • KPS SOLUCIONES EN ENERGÍA, S.L.
  • Parque Empresarial de Argame,
  • C/Picu Castiellu, Parcelas i-1 a i-3
  • E-33163 Argame, Morcín
  • Asturias, España, (Spain)