KPS DCM4010FLEX Flexible Current Probe Meter User Manual

October 27, 2023
KPS

DCM4010FLEX
Flexible Current Probe Meter
User ManualKPS DCM4010FLEX Flexible Current Probe Meter
-

Read First

Safety Information

To ensure safe operation and service of the meter, follow these instructions. Failure to observe warnings can result in severe Injury.
Warning
Identify hazardous conditions and actions that could cause
BODILY HARM or DEATH
– Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurement is to be carried out could Be ACCESSIBLE.
– If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
– To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
– Verify the Meter operation by measuring a known Current. If in doubt, have the Meter serviced.
– Do not apply more than the rated voltage/Current, as marked on Meter.
– To avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator.
– Do not use Meter around explosive gas or vapor.

KPS DCM4010FLEX Flexible Current Probe Meter - Flexible AC current
probe

– Do not use a flexible current sensor if the inner copper wire of the flexible cord is visible.
– De-energize the installation under test or wear suitable protective clothing during fitting a removal of the Flexible Current Probe.
– Do not apply around or remove from UNINSU LATED HAZARDOUS LIVE conductors, which may render electric shock, electric burn, or arc flash.
Caution
Identify conditions and actions that could cause DAMAGE the meter or equipment under test. Do not expose Meter to extremes in tempera- ture of high humidity.

Symbols as marked on the meter and Instruction card

| See instruction manual
---|---
| Do not apply to or remove from  HAZARDOUS LIVE conductors.
| Equipment protected by double or reinforced insulation
| Battery
| Earth
| Conforms to EU directives
| Do not discard this product or throw away
| AC measurement

Auto Power off Function

KPS DCM4010FLEX Flexible Current Probe Meter - Power off
Function

The meter automatically turns the power off after powering up and no operation for 20 minutes ± 30 seconds.

Maintenance

Do not attempt to repair this Clamp Meter.
It contains no user-serviceable parts.
Repair or servicing should only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and detergent.
Do not use abrasives or solvents.

KPS DCM4010FLEX Flexible Current Probe Meter - Power off
Function

Press “Power” button, and during the LCD shows battery capacity, press “backlight” button until the LCD shows “AoFF” to disable Auto Power Off Function.

Backlight

Environmental Specifications

Indoor Use.
Pollution Degree : 2
Maximum operating altitude : 2000m (6562 ft)
Operating temperature & Relative Humidity :
0°C – 30°C, ≦80%RH
30°C – 40°C, ≦75%RH
40°C – 50°C, ≦45%RH
Storage temperature :
-20°C – 60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
Shock vibration : Sinusoidal vibration
MIL-PRF-28800F (5-55 Hz, 3g max.)
Drop Protection : 4 feet drop to hardwood on concrete Floor

Data Hold

Electrical Specifications
Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H.
Accuracy is specified for a period of one year after calibration.
Position Error of Clamp :
Accuracy and position error assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

| sFlex-10| Error
---|---|---
Distance from Optimum (mm)| 15| ±2.0%
25| ±2.5%
35| ±3.0%

Replacing Batteries

Caution
Remove Meter from conductor and turn off power before opening the battery cover.

AC Current

Range OL Reading Resolution Accuracy (45Hz~500Hz)
30.00A 33.00A 0.01A ±(3.0% + 5D)
300.0A 330.0A 0.1A ±(3.0% + 5D)
3000A 3300A 1A ±(3.0% + 5D)

LCD displays 0 counts when the reading < 10 counts.
Frequency Response : 45 – 500Hz (Sine Wave)
AC Function
ACA specifications are ac coupled, true R.M.S.
For non-sinusoidal waveforms, Additional
Accuracy by Crest Factor (C.F.):
Add 3.0% for C.F. 1.0 – 2.0.
Add 5.0% for C.F. 2.0 – 2.5.
Add 7.0% for C.F. 2.5 – 3.0.

General Specifications

Display : 3000 counts.
Over range Display : “OL”
Dimensions (W x H x D) :
10″ coil : Approx. 120mm x 280mm x 25mm
Weight(without Battery) :
10″ coil : 170g
Power Requirements : AAA Size Battery x 2
Battery Life : 200 hours ALKALINE Battery
Low Batteries Indication :
Voltage drops below operating voltage, will flash.
Maximum Conductor Size : coil size
Safety Standard :
EN61010-1, EN61010-2-032, EN61326-1
CAT IV 600V, CAT III 1000V
Conversion Rate : 4 times/second

CANADA & USA
MGL America, Inc.
cs.naTimgl-inticom
2810 Coliseum Centre Drive, Ste. 100. Charlotte, North Carolina 28217 USA
Tel: +1 833 533-5899| MEXICO & LATAM
MGL LATAM S.A DE CV
cs.latam@mgl-inti.com
Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F
Tel: +1 833-533-5899
---|---
EMEA
MGL Euman, S.L.
cs.emea@mgl-intl.com
Parque Empresarial Argame, 33163 Morcin. Asturias, Spain.
Tel: +34 985-08-18-70| UNITED KINGDOM
MGL GROUP U.K. LIMITED
cs.uk@mgI-intl.com
14 Weller St, London, SE1 1QU, UK
Tel: +34 985-08-18-70

www.kps-intl.com
SKU Number: KPSDCM4010FLEXCBINT
700019556 MAY 2021 V1
©2021 MGL International Group Limited. All rights reserved.
Specifications are subject to change without notification.

Documents / Resources

| KPS DCM4010FLEX Flexible Current Probe Meter [pdf] User Manual
DCM4010FLEX Flexible Current Probe Meter, DCM4010FLEX, Flexible Current Probe Meter, Current Probe Meter, Probe Meter, Meter
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals