VIKING VK2CH10 Residential Vehicular Slide Gate Operator Instruction Manual

August 19, 2024
VIKING

VIKING VK2CH10 Residential Vehicular Slide Gate Operator

Specifications

  • Product Name: VIKING BLUE ENABLED
  • Operation: Solar Efficient
  • Gate Operator Class: I, III, and IV
  • Maximum Gate Weight: Up to 650 lbs.
  • Compliance: UL 325 and UL 991 Type I, III, and IV

Installation Guidelines

  1. Ensure installation is carried out by qualified personnel only.
  2. Refer to the Plans of Installation section for detailed installation instructions.
  3. Follow the provided Parts Diagram/Parts List for assembling the gate operator.

Electrical Installation

  1. For Master/Slave Connections, refer to the Electrical Installation section.
  2. Connect Vehicular Loop Detectors as per the Loop 0Layout Diagrams provided.
  3. Install necessary accessory connections for open commands and safety connections.

Special Features

  1. Fine Tune Limit Setting allows precise adjustment of gate limits.
  2. Auto Open Feature enables automatic gate opening.
  3. Intelligent Obstruction Sensor provides primary entrapment protection.
  4. Fail Safe/Fail Secure Operation ensures gate security.
  5. Hold Open Timer feature can be set for specific durations.

Optional Installations

  1. VikingBlue Wireless Master/Slave Installation can be opted for advanced control.
  2. Solar Panel Installation is available for energy-efficient operation.
  3. Pipe Stand or Pedestal Stand installations can be chosen based on requirements.

FAQs

Q: What is the maximum weight capacity of the VIKING gate operator?
A: The VIKING gate operator can handle gates weighing up to 650 lbs.

Q: Can the gate operator be operated using solar power?
A: Yes, the gate operator is solar efficient and can be operated using solar panels installed as per instructions.

Q: How can I adjust the gate limits accurately?
A: Utilize the Fine Tune Limit Setting feature for precise adjustment of gate limits.

IMPORTANT SAFETY INSTRUCTIONS
WARNING ­ To reduce the risk of severe injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the manual release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. Every gate operator installation MUST have secondary protection devices against entrapment, such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occur.
9. SAVE THESE INSTRUCTIONS.

IMPORTANT INSTALLATION INSTRUCTIONS
1. Install the gate operator only when: a) The operator is appropriate for the construction of the gate and the usage Class of the gate (refer to page 5), b) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position, c) ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED, AND d) GUARDING IS SUPPLIED FOR EXPOSED ROLLERS.
2. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
3. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.
5. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH PERIMETER,

2

TECHNICAL SUPPORT 1 800 908 0884

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN

WARNING – Not following these instructions may cause severe injury or death to persons.

IMPORTANT INSTALLATION INSTRUCTIONS Continued

6. Controls intended for user activation must be located at least six feet (6′) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use.

7. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.

8. All warning signs and placards must be installed where visible in the area of the gate. A minimum of two placards shall be installed. A placard is to be installed in the area of each side of the gate and be visible to persons located on the side of the gate on which the placard is installed.

9. For gate operators utilizing a non-contact sensor (Photo beam or like) in accordance with section 31.1.1 of the UL325 standard:
a) See instructions on the placement of non-contact sensors for each Type of application (refer to page 6),
b) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and
c) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier (refer to page 6).
d) Use only Omron E3K-R10K4 photoelectric eye to comply with UL325

10. For a gate operator utilizing a contact sensor (Edge sensor or like) in accordance with section 31.1.1 of the UL325 standard:
a) One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate (refer to page 7).
b) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
c) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
d) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
e) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
f) One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge (refer to page 7).
g) One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
h) Use only Miller Edge Model MGR20 or MGS20 edge sensor to comply with UL325

TECHNICAL SUPPORT 1 800 908 0884

3

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN

WARNING – Not following these instructions may cause severe injury or death to persons.

MAINTENANCE
Remove the Power Harness from the Control Board (refer to page 14) · Clean and lubricate the gate track wheels using the recommended lubricant. · Inspect the track for any signs of cracking or separation. · Check that all mounting hardware of the gate operator is properly tighten. · Ensure that the gate moves freely. · Check for corroded parts and replace if necessary. · Check the battery for the following:
Battery connections must be free of corrosion. Battery voltage must be 26 VDC (fully charged battery). Reconnect the Power Harness for the Control Board (refer to page 14) · Check and confirm the proper operation of all safety devices (photoelectric eye, edge sensors or like). · Check and confirm the operation of all installed accessories. · Check and confirm the operation of all special features such as the Intelligent Obstruction Sensor, Hold Open Timer (refer to page 23 to 28) · Check and confirm the operation of the manual release (refer to page 7) · Verify battery backup functionally by turning off the power source (120 VAC and 220 VAC). DO NOT FORGET TO TURN ON THE POWER SOURCE AFTER VERIFICATION.
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully as they contain important indications for the safe installation, use and maintenance. · These instruction must be kept and forwarded to all possible future users of the system. · This product must be used only for that which it has been expressly designed. · Any other use is to be considered improper and therefore dangerous. · The manufacturer cannot be held responsible for possible damage caused by improper, erroneous or
unreasonable use. · Avoid operating in the proximity of the hinges or moving mechanical parts. · Do not enter the path of the moving gate while in motion. · Do not obstruct the motion of the gate as this may cause a situation of danger. · Do not allow children to play or stay within the the path of the moving gate. · Keep remote control or any other control devices out of the reach of children, in order to avoid possible
involuntary activation of the gate operator. · In case of break down or malfunctioning of the product, disconnect from the main power source. Do not
attempt to repair or intervene directly, contact only qualified personnel for repair. · Failure to comply with the above may create a situation of danger. · All cleaning, maintenance or repair work must be carried out by qualified personnel. · In order to guarantee that the system works efficiently and correctly it is important to have the manufacturer’s
instructions on maintenance of the gate and operator carried out by qualified personnel. · In particular, regular checks are recommended in order to verify that the safety devices are operating correctly.
All installation, maintenance and repair work must be documented and made available to the user.

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN

CAUTION: To Reduce the Risk of Fire or Injury to Persons
a) Use only the following type and size of battery(ies): Yuasa NP7-12
b) Do not dispose of the battery(ies) in fire. The cells may explode. Check with local codes for possible disposal instructions.
c) Do not open or mutalate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic fi swallowed.
d) Exercise care in handling batteries in order not to short the battery with conductying materials such as rings, bracelets and keys.
e) Change the battery(ies) provided with or identified for use with this product only in accordance with the instructions and limitations specified in this manual.
f) Observe proper polarity orientation between the battery(ies) and charging circuit.
g) Do not mix batteries of different sizes or from different manufacturers in this product (applies to products employing more than one user replaceable secondary battery).
h) A battery-operated product employing a secondary battery supply intended to be charged within the product shall contain specific instructions concerning the proper method of charging.
UL325 Gate Operator Classification
GLOSSARY
RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I ­ A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II ­ A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR CLASS III ­ A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV ­ A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Install the gate operator only when: The operator is appropriate for the construction of the gate and the Usage Class of the gate.

5

TECHNICAL SUPPORT 1 800 908 0884

5

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN
WARNING – Not following these instructions may cause severe injury or death to persons.
NOTE – This type of installation DOES NOT reverse the gate all the way back to its limits when the photo-beam is obstructed. This installation is only to protect against entrapment and to comply with UL325.
Photo Beam (non-contact sensor) Installation
Secondary Entrapment Protection
Photo beams or like must be installed to reduce the risk of entrapment. Use only Omron E3K-R10K4 photoelectric eye to comply with UL325 Make the electrical connections of the photoelectric sensor as described here in this page. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and One or more non-contact sensors shall be located where the risk of entrapmentor obstruction exists, such as the perimeter reachable by a moving gate or barrier.
Turn Switch to ‘Light On’ Position

Exit
Gnd Center Gnd Reopen Gnd UL Gnd +28v
Gnd Radio

Radio Statio

Radio Station

Safety Connector

Loop Connector

1

3

(C1) (NC1)

Connection ‘1’ (C1) Connection ‘3’ (NC1) 24 VDC Power Connections 24 VDC Power Connections

24VDC
Omron Model E3K-R10 Shown

Reflector

Potential Entrapment Area (Shaded)

Photo Beam Unit

Gate in Closed Position

Contact Sensor

Contact Sensor

One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
Consult the installation manual for the UL325 device (photo beam or like) for detail information about the usage, installation and maintenance

6

TECHNICAL SUPPORT 1 800 908 0884

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN

WARNING – Not following these instructions may cause severe injury or death to persons.

Edge Sensor (contact sensor) Installation

Secondary Entrapment Protection

All Contact Sensors to be Wired In Parallel

Exit
Gnd Center Gnd Reopen Gnd UL Gnd +28v
Gnd

Safety Connector

Loop Connector

Contact Sensor

Contact Sensor

Edge sensor or like must be installed to reduce the risk of entrapment.
Use only Miller Edge 3-sided activation type MGR20 or MGS20 to comply with UL325
One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
1. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.
2. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
Manual Release
When manual operation is required:
Remove the cover, locate the Reset Switch and turn it to the “OFF” position. The gate can now move manually.
Turn the switch to the “RESET” position to resume normal operation.

TECHNICAL SUPPORT 1 800 908 0884

7

IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNFFOORRMMAATTIIOONN
WARNING – Not following these instructions may cause severe injury or death to persons.
Audible Alarm Reset Switch Installation
Manual Reset for the Audible Alarm UL325 standard requires an audible alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor). The audible alarm will continue to sound for 5 minutes or until a stop command gets actuated. The Stop command can be actuated in two different forms 1. Using the Built in Stop switch on the Control Box or 2. Using an External Stop button within the sight of the gate, away from moving
parts of the gate and out of reach of children. 3. Controls intended for user activation must be located at least six feet (6′) away
from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 4. The Stop and/or Reset button must be located in the line- of-sight of the gate. Activation of the reset control shall not cause the operator to start.

6′
STOP
5′ Minimum

Out of Reach Manual Stop Button
Warning Placard Installation

Guard Station

Guard Station

Master/Slave

GND Close Stop Open
GND Close Stop Open
Gnd

Master/Slave

All Warning Signs and Placards must be installed where visible in the area of the gate. A minimum of two placards shall be installed. A placard is to be installed in the area of each side of the gate and be visible.

8

TECHNICAL SUPPORT 1 800 908 0884

IIMMPPOORRTTAANNTT IINNSSTTAALLLLAATTIIOONN IINNFFOORRMMAATTIIOONN
CAUTION – FOR USE WITH GATES OF A MAXIMUM OF 27 FT IN LENGTH AND 650 LBS. IN WEIGHT. WARNING – TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS:

Do not allow pedestrian use of this gate!

Do NOT Install the gate operator to lift gates

27′-0″
27′ maximum gate length
650 lb.
MAX.
650 pounds maximum gate weight
Specifications
Maximum Gate Length: Maximum Gate Weight: Power Requirements: Operating Temperature:

OPEN STOP CLOSE
Control Buttons
Locate Control Buttons: 1. Within sight of the gate, 2. At a minimum height of 5 feet so small
children are not able to reach it, and 3. Away from the gate opening so that someone cannot operate the controls while in the path of the gate, and 3. Away from all moving parts of the gate.
27 feet 650 lbs. 120 VAC Single Phase at 2 Amps Or 220 VAC Single Phase at 1 Amp -20°C (-4°F) to 70°C (158°F)

TECHNICAL SUPPORT 1 800 908 0884

9

PPLLAANNSS OOFF IINNSSTTAALLLLAATTIIOONN

All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2-1/2 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.

Gate In Open Position

Gate In Closed Position

Track Concrete Pad

Gate Operator Concrete Pad

Gate Operator

Gate Operator Track Concrete Pad Concrete Pad

Gate Operator

Figure A Plan of Front Installation
Gate In Open Position

Gate In Closed Position

Gate Operator Concrete Pad

Track Concrete Pad

See Detail Below

Gate Operator Concrete Pad

Track Concrete Pad
Route Chain As Shown

Gate
Safety Guard Fixed Pulley

Parts Not Supplied by Viking Access Systems

Gate Operator Concrete Pad
Detail of Rear Install Chain Route
Figure B Plan of Rear Installation

10

TECHNICAL SUPPORT 1 800 908 0884

PPLLAANN OOFF IINNSSTTAALLLLAATTIIOONN ­­ CCOONNCCRREETTEE PPAADDSS

Track

Gate

2″ 4″

10″

Minimum

Install a Positive Stop at Both Ends 18″ of the Track Operator Cover Operator Chassis
4″
Center of Drive Chain
10.375″ 6″

11″ Track Concrete Pad

Gate Operator Concrete Pad

16″

24″
Drill for a 1/2″ x 3-1/2″ Red Head Anchor (4) Places

2″ 8.5″

Possible Area for Conduit(s) (1″ Maximum Height)

1.5″
4″ Minimum

5.5″

13″

Recommended Area for

Conduit Location Conduit(s)

24″ Grade Level See Note 2 Track Concrete Pad
Gate Operator Concrete Pad
1. Follow the local building code to determine the required depth of the concrete pad.
2. Pad measurements recommended by Viking Access Systems are at lease 24″ long, 18″ wide and 24″ deep to ensure the stable operation of the operator, and a minimum of 4″ above level grade to avoid any flooding of the machinery.
3. The path of the track must be 10″ wide and at least 6″ deep to support the weight of the gate. Please consult the local building code for verification and further details.
4. Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads, maglock, non-contact sensors, contact sensors, safety and other commands.Also provide conduit for the power supply (either 110 or 220 VAC). Extend the conduit the recommended height of 1″ above the level of the concrete pad. Install all conduit in the shaded area shown above.

TECHNICAL SUPPORT 1 800 908 0884

11

GGAATTEE OOPPEERRAATTOORR IINNSSTTAALLLLAATTIIOONN
Note: Before starting the installation procedure; · Open and close the gate manually, making sure there is sufficient space between
the gate and adjacent walls. · Check that the wheels are turning freely on the track and there are no restrictions
while pushing the gate to the open and closed positions. · Confirm that there is adequate spacing for the guide rollers and that there are no
restrictions throughout the travel of the gate.
STEP 1
Before anchoring the chassis to the concrete pad, make sure the gate and operator are LEVEL and PARALLEL. Minimum distance between the operator and gate is 3″.
STEP 2
Attach the operator to the concrete pad using Red Head 1/2″ x 3-1/2″ Anchors. Follow the manufacturers instructions for proper installation. Refer to page 11 for hole center dimensions.

12

TECHNICAL SUPPORT 1 800 908 0884

16

GGAATTEE OOPPEERRAATTOORR IINNSSTTAALLLLAATTIIOONN

Step 3
Chain Installation: Before welding the provided chain brackets, make sure the chain will be in a straight line with, and at the same height as, the chain leaving the gate operator rollers.

10.375″

17

TECHNICAL SUPPORT 1 800 908 0884

13

EELLEECCTTRRIICCAALL IINNSSTTAALLLLAATTIIOONN

Caution ­ Do not connect the power harness to the board until the installation is ready for verification.

24V BAT 24VAC

Black Red Green White

Auxiliary Power Connection. See page 28 for further details.
Power Harness

115V/220V Power Switch

Earth Ground Power Ground

3A FUSE Part # VAEMI

To Transformer

Neutral Hot

Earth Ground Ground Rod

STEP 4
The Gate Operator requires a single phase AC line to operate the gate and charge the batteries. A. Turn off the main switch or breaker for
the power line being used. B. Move the selector switch on the Incoming
Voltage Selector to the proper position (115 for 110 to 120VAC, 230 for 200 to 240VAC). C. Connect the incoming power wires to the terminals as shown in the illustration. D. Turn on the main switch or breaker once the installation is ready for final adjustments. E. To verify that there is AC power to the system, check that the `Charger’ LED on the Control Board is on.
Tips for proper ground installation A good ground in a gate operator installation will minimize or prevent damage to the operator cause by natural events such as lightning strikes. The following will provide a guideline for proper grounding: 1. Use a ground rod to provide a ground
reference. 2. Consult your city code and be aware of
under-ground services in the site of the gate operator to prevent inconveniences. 3. Use always a single bonding point for grounding. 4. All ground wires must be as short and as thick as possible. 5. Prevent unnecessary turns or loops in all ground wires.

14

TECHNICAL SUPPORT 1 800 908 0884

18

OPEN LEFT

EELLEECCTTRRIICCAALL IINNSSTTAALLLLAATTIIOONN
Power Connections
STEP 5
Connect the wire harness to the “OPEN RIGHT” connector if the gate opens to the right. Connect the wire harness to the “OPEN LEFT” connector if the gate opens to the left.

OPEN RIGHT

OPEN

Gate Opens Right

Inside View

OPEN

OPEN LEFT

OPEN RIGHT

Inside View
Limit Switch Connections
The Limit Switches are pre-wired. Should the wires become disconnected, use this diagram to reconnect them.

Gate Opens Left

Red Black

NC

Lower Limit Switch Upper Cam

NO COM

COM NO NC

Green White

Upper Limit Switch

TECHNICAL SUPPORT 1 800 908 0884

15

LLIIMMIITT SSWWIITTCCHH SSEETT–UUPP

Note: Open and close the gate without interruption every time you change the adjustment.

OPEN LEFT

OPEN RIGHT

Upper Cam sets Open Position
Lower Cam sets Close Position

Upper Cam sets Close Position
Lower Cam sets Open Position

STEP 1
Set the Fine Tune Limit Pot to zero on the Control Board.
Trim Pot Location

min.

min.

0

0

3

3

Delay

Obstruction
Sensor

1.5

1.5

truction Sensor

Overlap Delay

Obstruction
Sensor

Overlap Delay

Overlap

This `Trim Pot’ can be used to FINE ADJUST the closing position of the gate with a high degree of accuracy (up to 1/16″). The number on the Trim Pot dial sets the number of inches the gate travels after initial set-up.

STEP 2
Open the gate to the desired open position. Loosen and rotate the `Open’ Cam until the Limit Switch “clicks”. Tighten the cam.

Upper Limit Switch Upper Cam

Lower Limit Switch Lower Cam

STEP 3
Close the gate to within 6″ of desired closed position. Loosen and rotate the cam until the Limit Switch “clicks”. Tighten the cam.

Set Upper Cam

Set Lower Cam

in the Direction Shown in the Direction Shown

16

TECHNICAL SUPPORT 1 800 908 0884

15

LLIIMMIITT SSWWIITTCCHH SSEETT–UUPP
STEP 4
Press both limit switches at the same time to initiate the set-up (the open and close LEDs will blink on the Control Board).
STEP 5
Open and close the gate from limit to limit without interruption for two complete cycles.

Click! Click! Click!

Click! Click!

Activate Both Limit Switches At the Same Time

2X

Fully Open and Close the Gate 2 Times
STEP 6
Use the Fine Tune Limit Pot to perform minor adjustments to the closed position.
6″

Initial Setting
2-1/2″
First Adjustment
1/2″

Fully Open and Close the Gate After Every Adjustment

Second Adjustment

TECHNICAL SUPPORT 1 800 908 0884

17

SSPPEECCIIAALL FFEEAATTUURREESS
Fine Tune Limit Setting
The Fine Tune Limit Pot is used to closely set the final stop of the gate travel. The position can be set to the nearest 1/2″ via the markings for the Trim Pot. See page 16-17 for setup procedure.

Close
Stop
Open
Hold Open Timer

Hold Open

Hold Open Timer

Limit

Limit

min.

Overlap

Trim Pot Location

Obstruction
Sensor

min.

0

0

3

3

Delay

Obstruction
Sensor

1.5

1.5

truction Sensor

Overlap Delay

Overlap Delay

18

TECHNICAL SUPPORT 1 800 908 0884

EELLEECCTTRRIICCAALL IINNSSTTAALLLLAATTIIOONN ­­ MMAASSTTEERR//SSLLAAVVEE
Master/Slave Connections
Outside

Master Unit

Interconnecting Conduit

Opens First
Inside

Slave Unit

Caution ­ Do not run Master/Slave communication cable in the same conduit as the power supply (120-220V) cable.

Use 18 AWG stranded wire with foil overshield and drain wire or better.

Conduit

Shielded Cable
NOTE: Use 16 Gauge Wire for runs up to 100′
Shield Wire

Master/Slave
UL Siren

Master/Slave
UL Siren

Guard Station

GND Close Stop Open GND Close Stop Open
GND Close Stop Open GND Close

Guard Station

UL Siren
Master/Slave

Guard Station

Guard Station

UL Siren
Master/Slave

The control board provides a connector for master/slave connectivity. This connector will allow synchronized operation with a second gate operator.

Wire the operators as shown above and interconnect the two operators as follows:

Master Board

Slave Board

GND . . . . . . . . . . . . . . . . . . . .GND

Close . . . . . . . . . . . . . . . . . . .Close

Stop . . . . . . . . . . . . . . . . . . . .Stop

Open . . . . . . . . . . . . . . . . . . .Open

Purpose Reference Close Command Stop Command Open Command

Shield (to Earth)

Shield (to Earth)

Note: It is recommended to connect all external devices and set timer and overlap delay control on the master unit. Ensure Slave Control Board has timer set to `OFF’ to allow the Master to control the timer.

TECHNICAL SUPPORT 1 800 908 0884

19

VVEEHHIICCUULLAARR LLOOOOPP DDEETTEECCTTOORR IINNSSTTAALLLLAATTIIOONN

Outside ORuetsoipdeen Loop

Inside Reopen Loop Exit Loop

Note: Not all loops may be necessary for every installation. Check local regulations and accepted bestpractice design requirements.

Inside

Outside Inside

A

A
Outside Reopen
Loop

A

5′

Inside Reopen
Loop

Exit Loop

Gates in Closed Position

A
Dimension A ­ 5′ for Single Gate Operator 6′ for Master/Slave Gate Operator

20

TECHNICAL SUPPORT 1 800 908 0884

VVEEHHIICCUULLAARR LLOOOOPP DDEETTEECCTTOORR IINNSSTTAALLLLAATTIIOONN
WARNING ­ Consult the installation instructions from the loop detector manufacturer. The following statements are provided as a guide but different requirements may be required by the vehicular loop detector manufacturer.

Guidelines for Vehicular Loop Detector Installation
1. Prevent sharp corners in the geometry of the loop sensor.
2. Install the appropriate number of turns for your loop geometry based on the loop perimeter. Use Table C (below) as a guide.
3. Use XLP (cross-linked-polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector.
4. Twist the lead wire at least 6 turns per foot.
5. Use BACKER-ROD to minimize damage to the loop detector wire prior to using the sealant.
6. Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects of the gate over the loop detector wire.
IMPORTANT ­ Some of the following parameters may affect the proper functionality of the vehicular loop detector (consult the installation manual and the manufacturer of the vehicular loop detector). · Gate size, · Number of turns in the loop sensor wire; · Distance from the loop sensor wire to the gate either at the open or close position.

Saw Cut

1″ Min.
Sealant Backer-Rod Vehicular Loop Detector Wire (3 Turns Shown)

Table C ­ Recommended Number of Turns

Perimeter in Feet

Number of Turns

10

5

20

4

30-40

3

50-100

2

Continuously Wind Wire in Loop Slot for the Required Number of Loops (2 Loops Shown)

Provide Additional Saw Cuts to Eliminate Sharp Corners
1/8″ to 1/4″ Saw Slot
Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loop Detector

TECHNICAL SUPPORT 1 800 908 0884

21

LLOOOOPP RRAACCKK IINNSSTTAALLLLAATTIIOONN
Looprack ­ Viking Part # VA LR Looprack Wiring Harness ­ Viking Part # VA LRH

Viking Loop Rack

Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loop Rack

28V Gnd Exit Center Reopen

Exit Center Reopen

Exit Center Reopen

OP CN RO

Outside
Outside Safety Loop
Center Loop
Inside Safety Loop

Control Board Connector

Exit Loop
Inside
Loop Connector

GND Close Stop Open
Gnd Fire Gnd Strike Gnd Exit
Gnd Center Gnd Reopen Gnd UL Gnd +28v

Gnd Radio +28v Gnd +28v

Guard Station

Open Commands

Safety Connector

Radio Station

Close Stop Open

Mag. Lock

Mag. Lock

Radio Station N.O. COM N.C.
Mag. Lock

Mag. Lock

Loop Connector

Open Commands

Guard Station

Off 1

Close

Hold Open Timer

off 1 sec

60

60sec

30

30sec

Hold Open Timer

Timer

Hold Open

Open

Open Limit

Stop

Stop

Close Limit

22

TECHNICAL SUPPORT 1 800 908 0884

AACCCCEESSSSOORRYY CCOONNNNEECCTTIIOONNSS

1

Safety Connections

Photo

Safety

2

Beam

Edge Sensor

Loop Detector

Center Loop Detector

Connection Locations

1

Strike Gnd Exit
Gnd Center Gnd Reopen Gnd UL Gnd +28v

Vehicle loop detectors must be installed to decrease the possibility of vehicle entrapment on the gate (see page 20).
The SECONDARY ENTRAPMENT PROTECTION like the edge sensor and the photoelectric beam MUST BE PART OF EVERY SINGLE INSTALLATION to prevent pedestrian or animal entrapment (see pages 6 and 7).
The edge sensor and/or the photoelectric beam must be UL325 compliant devices.

Safety Connector

Loop Connector

Open Commands

Open Commands

Exit Loop Detector

Keypad

Fire Override

FIRE

Open Commands

2

Stop Open
Gnd Fire Gnd Strike Gnd Exit
Gnd Center Gnd

Guard Station

Open Commands

Safety Connector

Loop Connector

Open Commands

Guard Station

As an alternative to the Outside Reopen Loop, a photo beam unit can be used as shown.
Outside

Reopen Photo Beam
Photo Beam

Gnd Center Gnd Reopen Gnd UL Gnd +28v

Inside
TECHNICAL SUPPORT 1 800 908 0884

Radio Station

Radio Station N.O.

Gnd Radio +28v Gnd

Safety Connector

Loop Connector 23

Mag. Lock

AACCCCEESSSSOORRYY CCOONNNNEECCTTIIOONNSS
Radio Receiver
When connecting the Radio Receiver carefully verify the proper connections. The maximum voltage that the control board provides for external accessories is the maximum voltage of the battery, which is about 28 volts. In the event of an electrical short the board will protect itself by shutting down and will remain shut down until the short is corrected.

The control board provides two modes of operation that a radio receiver can control the gate:
Open-Stop-Close
1. By having the radio receiver connected as illustrated and with the Hold Open Timer OFF (see page 28):
Every command of the radio transmitter will control the gate as follow: a) First command opens the gate, b) Second command stops the gate and c) Third command closes the gate d) Any subsequent commands will continue
in the same order to control the gate.
This type of configuration is not recommended for a commercial installations.
Open Only
2. By having the radio receiver connected as illustrated and with the Hold Open Timer ON (see page 28):
Each command of the radio transmitter is ALWAYS AN OPEN COMMAND to the gate.

Radio Station

External Accessories
Radio Station N.O. COM N.C.

Mag. Lock

Gnd Radio +28v Gnd +28v

Gnd UL Gnd +28v

+24VDC Gnd NO COM
Loop Connector

Safety Connector

24

TECHNICAL SUPPORT 1 800 908 0884

23

GND Close Stop Open
GND Close Stop Open
Gnd Fire Gnd

Master/Slave

AACCCCEESSSSOORRYY CCOONNNNEECCTTIIOONNSS
Note: All controls are normally open.

N.O. OPEN

N.O. STOP

N.O. COM

CLOSE

Guard Station

Open Commands

Connection Locations

Open Commands

Guard Station

Master/Slave

Guard Station
The guard station provides control of the gate operator to open, stop and close the gate.
All three switches must be Normally Open type of switch, and can share the same common (ground).
Place the control switch box within sight of the gate, away from moving parts of the gate and out of reach of children.

24

TECHNICAL SUPPORT 1 800 908 0884

25

SSPPEECCIIAALL FFEEAATTUURREESS
Auto-Open Feature
The Auto-Open feature in Viking Gate Operators enables the following functionality in the event of power failure:
a) Open the gate in case of power failure (120 or 220 VAC). b) Keep the gate at the open position as long as the there is no power. c) Resume to normal operation when the power has been restored. The Auto-Open feature allows proper operation while opening in case of power failure for the following devices: · All accessories, · All safety devices, · All entrapment protections. The only operation that can not be executed while opening in case of power failure is to CLOSE the gate.

JP3 C35 C36

To enable the Auto-Open feature : Use the “jumper” provided and place it on the pinheader of JP3, on the terminals close to C35 as the illustration indicates.

UL Sens Radio Rec.
O

UL

Radio

Sensor Rec.

Charger Power Low Battery MChoetcokr SMeontsoorr

Mag. Lock

Mag. Lock

26

Once you put the “jumper” on the control board the “Check Motor” light will come on indicating that the Auto-Open feature has been enabled.
TECHNICAL SUPPORT 1 800 908 0884

SSPPEECCIIAALL FFEEAATTUURREESS
Intelligent Obstruction Sensor (Primary Entrapment Protection)

min. MAX

0

MAX min.

0

3

Center Loop

Delay

Obstruction
Sensor

1.5

Center Loop

Center Loop

1.5

Obstruction Sensor

Overlap Delay

Obstruction
Sensor

Trim Pot Location

Overlap Delay

Turning the Trim Pot clockwise increases the sensitivity.
Turning the Trim Pot counterclockwise decreases the sensitivity.

The Obstruction Sensor detects obstructions in the path of the traveling gate. The Trim Pot for the Obstruction Sensor adjusts the sensitivity level that triggers the Sensor.
When the Obstruction Sensor detects an obstruction it will:
1. Stop the gate’s movement and reverse it momentarily.
2. Bring the gate to a resting position.
3. Disable the Hold Open Timer feature until the Gate Operator receives a new command.
If another obstruction is detected before the gate reaches either limit it will:
1. Stop the gate’s movement.
2. Bring the gate to a resting position.
3. Disable the Gate Operator.
UL325 standard requires an audio alarm to go off after two consecutive entrapment events sensed by the Inherent Entrapment Protection of the Gate Operator.
The audio alarm will sound for a period of 5 minutes or until the “Stop” Button is pressed (see page 8 for remote installation of a “Stop” Button).

TECHNICAL SUPPORT 1 800 908 0884

27

SSPPEECCIIAALL FFEEAATTUURREESS

Fail Safe/Fail Secure Operation

2

The gate operator contains a unique design that

allows the user to move the gate manually in case

of power failure.

1

There are three levels of force required to move

the gate manually.

Connection Locations

Fail Safe: By removing the wire-jumper plug from the “Fail Safe/Secure” connector:
The gate can be move manually with relative low amount of force.

Fail Secure: By inserting the wire-jumper plug into the

1

“Fail Safe/Secure” connector:

The gate can still be move by hand with

relative high amount of force.

In case of faulty operation or power failure, remove the cover, locate the Reset Switch and turn it to the “OFF” position. The gate can now be pushed manually.

At the end of operations, turn the switch to the “RESET” position to resume normal operation.

EN LEFT

FaSial SfeaF/feSa/eiSlceucruere

Hold Open Timer

The Hold Open Timer function holds the gate at

the open position for a predetermined amount of time, prior to closing automatically.

2

Set the Timer to the desired time, from 1 to

60 seconds.

If this feature is not needed, turn the Trim Pot clockwise to the “off” position.

Note: The Hold Open Timer affects the “radio receiver command” and the sequence of operation for the gate (see page 24).

Off 1

Hold Open Timer
Stop Open

off 1 sec

60

60sec

30

30sec

Hold Open Timer

Timer

Hold Open

Open Limit

Open

Stop

28

TECHNICAL SUPPORT 949-753-12T7E9CHNICAL SUPPORT 1 800 908 0884

27

OOPPTTIIOONNAALLVVIIKKIINNGG BBLLUUEE IINNSSTTAALLLLAATTIIOONN

WARNING ­ Connecting the plug backwards can result in damage to the Control Board and will render the Viking-Blue Module useless.

Close Stop

JP3 C35 C36

VikingBlue Wireless Master/Slave
1. Decide which Operator will be the Master and which will be the Slave.
2a. Install the “Master” Viking Blue Module on the Master Control Board.
2b. Install the “Slave” Viking Blue Module on the Slave Control Board.
Use care in connecting the plug to the Control Board. The pins are small and easily bent. Match the white dot on the plug to the white dot on the control board (near the JP2 legend as depicted).
3. Install the Jumper (near the JP3 legend depicted). Viking-Blue requires this jumper to operate as a Master/Slave device. The “Low Battery” LED will turn ON, indicating the Control Board is ready for use with the Viking-Blue Module.
4. Attach the Viking-Blue Module to the Operator. For better communication and performance follow these guidelines:
· The Module must be under the Operator Cover.
· The Modules must be facing each other as much as possible.
The Light on the Viking-Blue module will turn green upon connection between the other Module.
Be sure to test your Master/Slave communication.

Rec. Mag. Lock

Centoerop

JP2

ObstructiSoennsor

MAX

min.

OverlDaelpa1.y5

3 0

en

Match up Match up WMhJaiPttce2hDuopts WhJiPte2 Dots
JP2
Install Install JIunmstpaellr
Charger Power Low Battery Check Motor
VIKINGBLUE
FdSCciseCocrnioIanDnlen:#ceTtce9tdJeRd(gN(rre4ee1dn-)1)

Open

TECHNICAL SUPPORT 1 800 908 0884

29

Charger Power Low Battery CMhoetcork SMeontsoorr
Mag.

Mag. Lock
24V BAT 24VAC
OPEN RIGHT

OOPPTTIIOONNAALLSSOOLLAARR PPAANNEELL IINNSSTTAALLLLAATTIIOONN
For Viking Vehicular Gate Operators

Use one 24V 80W solar panel or two 12V 40W solar panels.

Connect the Solar Panel Controller as shown.
Solar Input Battery Input Load Input

­

­

­

+ ­ +
­

Remove the existing Power Harness and use the power harness provided.
Remove existing batteries. Use new external batteries of 35 AHr or greater and connect them in series to provide a 24V system.

30

TECHNICAL SUPPORT 1 800 908 0884

SSOOLLAARR PPAANNEELL IINNSSTTAALLLLAATTIIOONN
For Viking Vehicular Gate Operators

WARNING ­ Solar Panel must be UL Listed, Class 2

STEP 1
Use a 24V solar panel or two solar panels of 12V in series with a total capacity of 80 Watts..

24 VDC Panel

12 VDC Panels

­ +

­

Connect To Gate

Operator Input Block

24V BAT 24VAC
T

STEP 2
Connect the solar panel cables to the power harness as shown. Make sure you cut the wires coming from the toroidal transformer.
STEP 3
Replace the existing batteries with a battery pack of 35AHr or greater.

STEP 4
Refer to the maps provided to get an idea about the number of cycles the gate will be operated per day. This figure is for a single gate operator with just:
a) One Radio reiver, b) One low voltage low current loop detector and c) One low voltage, low current photo cell

Number of Cycles per Day*
14 12 10 8 5 2

January

*With a 80 Watt (24VDC) Panel System.

Cut the Leads to the Toroidal
Transformer

Connect Leads from Solar Panel(s), Polarity is not important

­

­

­

Reuse Existing Battery Fuse Holder

Red Wire Black Wire
Connect New Batteries to Existing Leads Observing Polarity

July

1. The greater capacity of the batteries, the longer the system will operate on cloudy days. 2. If more specific information is needed, please consult with Viking Access Systems. For more information regarding solar energy refer to http:/www.nrel.gov.

28

TECHNICAL SUPPORT 1 800 908 0884

31

VVIIKKIINNGG PPIIPPEE SSTTAANNDD
For Viking K-2 Vehicular Gate Operator

Standard Features
· Main pieces made of 1/4″ thick material · Includes Positioning Bar to aid in the
installation process · All hardware included

Gate
16″ (Reference)

4″ Minimum

K-2 Gate Operator (sold separately)

Positioning Bar
16″ (Reference)

5.50″ .3125″

Mounting Bolt Washer L-2 Gate Operator
Pipe Stand Washer
Mounting Nut
Note: All Mounting Hardware Supplied with Pipe Stand

10.00″

15.875″ with 2-1/2″ IPS Pipe
(2.875″ OD)

Top of Pipe

3.00″O.D. Pipe (Maximum)

Grade Level
Consult Local Codes for Depth and Concrete Requirements

When installing the Pipe Stand Assembly be sure it is parallel to the gate and that both sides are positioned square to each other and level. For further details see page 10 & 11.

32

TECHNICAL SUPPORT 1 800 908 0884

29

VVIIKKIINNGG PPEEDDEESSTTAALL SSTTAANNDD
For Viking K-2 Vehicular Gate Operator
Standard Features
· Main pieces made of 1/4″ thick material · All hardware included

4″ Minimum
1.55″

Gate

K-2 Gate Operator 2.00″ (sold separately)

11″ (Reference)
16″ (Reference)
22.5″ 24.5″

10.10″ 14.10″
Mounting Bolt Washer K-2 Gate Operator
1.00″ Pedestal Stand Washer Mounting Nut
Note: All Mounting Hardware Supplied with Pedestal Stand
Approximate Chain Centerline

12.00″ 8.625″ 7.125″ 5.625″
Grade Level

When installing the Pedestal Stand Assembly be sure it is parallel to the gate and that it is positioned square level. For further details see page 10 & 11.

30

TECHNICAL SUPPORT 1 800 908 0884

33

OOPPTTIIOONNAALLVVIIKKIINNGG BBLLUUEE IINNSSTTAALLLLAATTIIOONN

3 0
Open
Hold Open

ObstructiSoennsor
min. MAX

CenLtoerop

JP2

Rec. Mag. Lock

OverlDaelpa1.y5

Match up Match up WWMhhJJaiiPPttcee22hDDuoopttss
JP2
Install Install JIunmstpaellr Jumper
Charger Power Low Battery Check Motor

JP3 C35 C36

Close Stop

1. Insert CD into host computer 2. Install MS ActiveSync (check your
computer, it may already be installed to communicate with a PDA or smart phone. 3. Install Viking Blue software Select Install Viking-Blue for PC (to have the computer to communicate with the Operator) Select Install Viking-Blue for PDA (to have the PDA to communicate with the Operator) WARNING: If this PDA is a new device, turn off all options when syncing with the computer. For either installation, follow the steps in the user manual. 4. Plug the Viking Blue Module into the Viking Gate Operator Control Board. WARNING: Connecting the plug backwards can result in damage to the Control Board and will render the Viking Blue Module useless. Use care in connecting the plug to the Control Board. The pins are small and easily bent. Match the white dot on the plug to the white dot on the control board (near the JP2 legend as depicted). 5. Install the Jumper (near the JP3 legend depicted). Viking-Blue requires this jumper to operate. The “Low Battery” LED will turn ON, indicating the Control Board is ready for use with the Viking-Blue Module. 6. Open Viking Blue software on the chosen device.

If you are using the computer: · Hold the computer near the Gate
Operator. · Run the application by clicking the
icon on the desktop. · Select “Setting” in the top right of the
screen. If you are using a PDA: · Hold the PDA near the Gate Operator. · Select “Start” and “Programs”. · Click the Viking-Blue Application. · Select “Connection” on the toolbar.

· Click “Search” (looking for available Viking devices).
· Select the Operator you want to communicate with.
· Click “Connect” to start communication. The Light on the Viking-Blue module will turn green upon connection to the Computer or PDA.
Follow the steps in the user manual.

34

TECHNICAL SUPPORT 1 800 908 0884

TTRROOUUBBLLEESSHHOOOOTTIINNGG

Gate does not run ­ Check motor indicator comes ON

Check all motor connections to be fully engaged. Refer to page 15 and 16.

Ensure that the motor connections are: a) Properly connected, Refer to page 15.

Check that all motor cable connections, junctions and extensions are properly connected and color-coded.
Refer to page 15.

Check the 15 Amp fuse in the Ensure that the manual reset switch is at the `reset’ position.

control board.

Refer to page 7 and 28.

Gate does not run ­ Check motor indicator is OFF

Check all motor connections to be fully engaged. Refer to page 15.

Check that limit switches are connected to the common and the normally close position. Refer to page 16.

Check that the stop command is not active. Refer to page 8 and 25.

Check that the UL command (photo beam and/or edge sensor) is not active. Refer to page 6, 7 and 23.

Check that the vehicular loop Check that the radio command detectors are working properly. is not active. Refer to page 24. Refer to page 20, 21 and 23.

Ensure that you external acces- Check the 4 Amps fuse in the

sories are working properly.

control board

Ensure that you power cables are adequate in voltage and properly connected. Refer to page 14.

Gate does not run ­ Power failure

Check the 15 Amp battery fuse. Check the battery connections Check the voltage of the

and cables.

battery.

Gate does not run ­ Obstruction sensor ON and audio alarm is SOUNDING

Ensure that the gate path is clear of obstructions.

Note: To stop the audio alarm, use the stop command. Refer to page 8 and 25.

Adjust the trim pot of the obstruction sensor. Refer to page 27.

Gate runs, stops and reverse momentarily ­ Obstruction sensor ON and audio alarm OFF

Ensure that the gate path is clear of obstructions.

Check for proper functionality and lubrication of the gate and hardware (hinges and the like).

Gate ignores the limit switches

Adjust the trim pot of the obstruction sensor. Refer to page 27.

Check that the open limit switch and close limit switch are in the corresponding place. Refer to page 16.

Check that all motor cable connections, junctions and extensions are properly connected and color-coded. Specifically check the blue and black motor leads. Refer to page 16.

Check that the limit switch is not faulty

Check that wires to the limit switch are not shorted.

28

TECHNICAL SUPPORT 1 800 908 0884

35

TTRROOUUBBLLEESSHHOOOOTTIINNGG

Gate does not open or close

Check all motor connections to be fully engaged. Refer to page 15.

Check that limit switches are connected to the common and the normally close position refer to page 16.

Check that the stop command is not active. Refer to page 8 and 25.

Check that the UL command (photo beam and/or edge sensor) is not active. Refer to page 6, 7 and 23.

Check that the vehicular loop Check that the radio command detectors are working properly. is not active. Refer to page 24. Refer to page 20, 21 and 23.

Ensure that you external accessories are working properly

Automatic close does not function

Check that the trim pot of the hold open timer is set to the proper time delay. Refer to page 28.

Note: Hold open timer closes the gate automatically once the gate reaches the limit open.
The time delay to close is set by the trim pot.
To turn this system off turn the trim pot all the way clockwise

· Make sure gate is fully open · Check photobeam path for
obstruction · Check photobeam power · Check loop detectors for
proper function

Gate opens in the opposite desired direction

Verify your motor cable is connected to the proper connector. Refer to page 15 and 16.

Check that all motor cable connections, junctions and extensions are properly connected and color-coded.
Refer to 15.

On a Master/Slave installation, one gate runs in the opposite direction

Check the motor and limit switch wiring. Refer to page 15 and 16.

Verify that one unit is connected as open-left and one unit is connected as openright. Refer to page 15.

Verify the interconnecting wiring color codes match on both the master and slave boards. Refer to page 19.

Verify you are using shielded cables and that the shield is connected to the chassis ground at both ends, the master side and at the slave side.

36

TECHNICAL SUPPORT 1 800 908 0884

29

TTRROOUUBBLLEESSHHOOOOTTIINNGG

Gate opens. Closes or stops on its own

Make sure that the `Charger’ LED is on and not flashing, indicating that there is AC power.

Check that your wires from your accessories are: a) Not shorting together b) Not shorting a power line c) Not shorting to metal or earth ground.

`Charger’ LED off. Gate does not run – alarm sounds upon any input command

Check the 4 Amp fuse on the control board.

Check the 3 Amp fuse on the EMI control board. Refer to page 14.

Make sure the incoming AC line is properly connected. Refer to page 14.

Check the incoming high voltage power supply.

Check the proper selection of power supply (120/220 VAC). Refer to page 14.

Verify the EMI board by reading high voltage across the (4) blue and red wires at the terminal block connections.

Battery voltage reads zero or very low
Ensure the batteries are connected as follows: a) Left battery – Black terminal connected to the black wire from the harness (jacketed wire) b) Left battery – Red terminal connected to the red wire from fuse holder c) Right battery – Black terminal connected to the red wire from fuse holder d) Right battery – Red terminal connected to the red wire from the harness (jacketed wire)

TECHNICAL SUPPORT 1 800 908 0884

37

Notes

Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and it’s needs. As technology continues to advance, we have developed a completely efficient and intelligent line of gate operators to meet the changing demands. These machines offer; full UL325 and UL991 compliance, soft-start and soft-stop, intelligent obstruction sensors, continuous operation (100% duty cycle) and extreme power efficiency. Innovative features include; adaptive and self-learning algorithms, redundancy design in both hardware and software to ensure operation and functionality, protection from lightning, short circuit and power surges, and our exclusive helical gearing offering the highest efficiency rating in the industry. Our entire product line is continually modified and improved based on the latest technology and our customer’s valuable feedback. The results are products that offer accuracy, efficiency,
reliability and performance, all in sleek, high-tech designs.

We pledge to continue establishing ourself as the leader in high quality, innovative gate operators by developing “Next Level” technology. We are committed to providing safety
and convenience with innovative solutions for every security gate need.UL325 and UL991 Listed by Underwriter Laboratories (UL) · Accessible manual emergency release · Fail-Safe option sets the gate to automatically transfer to a fail-safe mode in the event of a power failure, allowing the gate to be pushed open without the use of special knowledge of the equipment · Fail- Secure option sets the gate to mechanically lock in the event of a power failure, allowing no manual movement without the use of the manual release · Standard Auto Open feature · Elegant design, appealing to any architectural project · Powder coated aluminum chassis · Opening up to 27′ · Operation speed of one foot per second · 100% duty cycle under very wide temperature range · Very low power consumption · 100 cycles of operation on backup battery (700 lb. gate and 20′ length) · Intelligent speed control with smooth start and stop, self-adjust system · Modulated speed regulator prevents exceeding operating speed that may reduce the service life of the gate operator and/or installation · Intelligent obstruction detection with adjustable sensitivity · Innovative fine tune adjustment for the end of gate travel (down to 1/8″) · Built-in protection against lightning strikes or similar electrical surges · Inherent overload
protection in the regulated power supply for external accessories with multiple devices of protection · Modular connectors for easy installation · Solar panel and low voltage wiring compatibility · LED indicators for verification of operation
Viking Access Systems Phone 800.908.0884 Fax 949.753.1640 631 Wald Irvine, CA 92618 www.vikingaccess.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals