SKIN XTC Beauty Pulse Microcurrent Device Instruction Manual

August 20, 2024
SKIN XTC

SKIN XTC Beauty Pulse Microcurrent Device

Product Information

Specifications

  • Battery Capacity: 500mAH
  • Battery Voltage: DC 5V / 1A
  • Battery Watts: 0.8W
  • Output Voltage: 3.2V
  • Working Current: 200mA
  • Operating Frequency: 0.8HZ~1.3MHZ
  • Material: Medical Grade Stainless Steel, ABS
  • Charging Time/Usage Time: 1 Hour / 90 minutes
  • Product Measurements: L176 x W59 x 39mm
  • Charging Mode: USB Charger
  • Origin: Made in Japan
  • Timer: 10 Minutes

Product Description
The XTC EMS Beauty Pulse is a device designed for facial treatments using microcurrent technology to target different skin layers and muscles.

Product Usage Instructions

  1. Apply an ample amount of SKIN XTC Hyaluronic Retinol Serum Gel to the EMS Beauty Pulse roller nodes or directly to the facial area.
  2. Press and hold the POWER ON/OFF button to turn on the device. Use the SLIM, UP, or BODY buttons to select the mode and the +/- buttons to adjust the intensity level from 1-5.
  3. Start the treatment by placing the roller nodes at the beginning of the facial area, moving the device slowly upwards, and repeating as needed.
  4. To turn off the device, press and hold the POWER ON/OFF button.

Treatment Guide

  • Tighten Jowls & Contour Jawline – 10 Minutes
  • Reduce Smiles Lines – 10 Minutes
  • Lift & Plump Cheeks – 10 Minutes
  • Reduce Under-Eye Wrinkles and Fine lines – 10 Minutes
  • Reduce Forehead Wrinkles – 10 Minutes
  • Massage and Relax Shoulder and Neck Muscles – 10 Minutes

Cautions
Make sure to follow the recommended treatment times and frequency of use to avoid any adverse effects on the skin. Consult a dermatologist if you have any skin conditions or concerns before using the device.

Warranty Information
The EMS Beauty Pulse is covered by a 12-month manufacturer replacement warranty. Refer to the warranty policy for details on returns, refunds, and replacements.

FAQ

  • Q: How often should I use the EMS Beauty Pulse?
    A: For best results, it is recommended to use the device weekly with specified treatment times for each area.

  • Q: Can I use the device on sensitive skin?
    A: It is advisable to perform a patch test before using the device on sensitive skin areas. Discontinue use if any irritation occurs.

Specifications

Battery Capacity 500mAH
Battery Voltage DC 5V / 1A
Battery Watts 0.8W
Voltage 3.2V
Working Current 200mA
Output Voltage 52V
Operating Frequency 0.8HZ~1.3MHZ
Material Medical Grade Stainless Steel, ABS
Charging Time/Usage Time 1 Hour / 90 minutes
Product Measurements L176 x W59 x 39mm
Charging Mode USB Charger
Origin Made in Japan
Timer 10 Minutes

Global Safety Certifications

Description

Waveform & Skin Layer

MODE WAVEFORM SKIN LAYER
SLIM Microcurrent Epidermis/Dermis Layer
UP Microcurrent/EMS Dermis/Muscle Layer
BODY EMS Muscle Layer

Operating Device

  1. Apply an ample amount of SKIN XTC Hyaluronic Retinol Serum Gel to EMS Beauty Pulse roller nodes or/and apply the gel directly to the facial area of the treatment
  2. Press and hold the POWER ON/OFF button to turn on the device. Press and hold the SLIM, UP, or BODY button to select mode, Press the +/- button to select level setting 1-5.
  3. Place the roller nodes at the start point of the facial area. Move the device slowly in an upward direction and repeat. Press and hold the POWER ON/OFF button to turn off the device.

Treatment Guide

Frequency of Use

MODE DAILY USE WEEKLY USE No. TREATMENTS
SLIM 10 minutes 60 Minutes 6 Treatments
UP 10 Minutes 60 Minutes 6 Treatments
BODY 10 Minutes 60 Minutes 6 Treatments

Safety Cautions

  1. Do not use the device on eyelids, undereye, Adam’s apple, armpits, chest area, or scalp.
  2. Ensure to keep the device gliding to avoid a stationary position in one spot.
  3. Keep away from water as the device is not waterproof.
  4. Rest the device in a base holder or safely store it in its packaging.
  5. Do not use a device if you have metal implantations, such as a pacemaker.
  6. Don’t use the device if faulty, and email customer support at info@skinxtc.com.
  7. Do not open the device, disassemble it, or attempt any repair.
  8. Only use the device for its intended purpose as stated via www.skinxtc.com and the user manual.
  9. Seek medical advice before use if, recently had surgery, receiving any medical treatment.
  10. Don’t use the device for 2 weeks after Botox, filler, laser treatments, or 7 days after chemical peels.
  11. Do not use a device if you are wearing electronic medical devices.
  12. Avoid use on sunburnt, inflamed, sensitive skin, or if you have dermatitis, melasma, or allergies.
  13. Always clean the device with a damp cloth, wet wipe, or cleansing pad after each use.
  14. Do not drop the device or hit it against a hard surface to avoid unintentional damage.

Warranty

EMS Beauty Pulse is covered by a 12-month manufacturer replacement warranty period. The 30-day refund/replacement return policy starts from the date of purchase. To return the device,

  1. Contact SKIN XTC by email with your order reference number and reason for return.

  2. If the return is approved, a return reference number will be provided in reply.

  3. Send the device with its return reference number to;
    SKIN XTC LTD Studio Gardens 71-75 Shelton Street Covent Gardens London, WC2H 9JQ United Kingdom

  4. Email the tracking ID number of the dispatched return to SKIN XTC, at info@skinxtc.com.

  5. Upon receipt of the return, an email is sent to confirm your refund or replacement.

  6. A refund or replacement will be issued 7 days after receipt of the return.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals