Danfoss RX1 Electronic Radio Frequency Receivers Installation Guide

August 16, 2024
Danfoss

Danfoss RX1 Electronic Radio Frequency Receivers

Installation Instructions

Wiring Details

Electronics

COM
On
Off
Zone
Boiler
CH
HW

RX1

Note : For mains voltage applications link terminals L and 2.

RX2

ATTENTION : If replacing a previous version of the RX2 receiver please use the new backplate supplied and wire as illustrated above.
RX2C

RX3

RX3B

RX3B-VF

Specification

| SPECIFICATION
---|---
Radio Controlled Room Thermostat Receiver Module for see list page 3
Supply Voltage| 230 Vac ± 15%, 50Hz
Construction| BS EN 60730-2-1, EN 300-220-1
Maximum Ambient Temperature| 45°C
Switch Type| RX1 – 1 x SPDT, type 1B
RX2 – 1 x SPDT, 1 x SPST, type 1B
RX3 – 1 x SPDT, 2 x SPST, type 1B
Switch Rating| 264 Vac, 3 (1) A (Total current)
IP Rating| IP 40
Control Pollution Situation| Degree 2
Max. Range| 30 metres
Operating Frequency| 433.92 MHz
Software Classification| Class A
Rated Impulse Voltage| 2.5kV
Ball Pressure Test| 75°C

Commissioning Instructions

Thermostat (refer to page 3 for thermostat type)
Step 1. Type A Press & hold buttons DOWN and + for 3 seconds
Type B Press & hold LEARN button for 3 seconds
Type C Remove dial, press & hold LEARN button for 3 seconds (located under setting dial)

Do not replace knob until Learn process is complete
NOTE : Thermostat now transmits continuously for 5 minutes.

Receiver

Step 2. RX1
Press and hold buttons PROG and CH1 for 3 seconds until green light + ashes

Step 3. RX2 / RX3 (if applicable)
Stat 1 – perform steps 1-2 for CH1
Stat 2 (RX2 & RX3)
Wait 5 mins, perform step 1, then press PROG + CH2 on RX2/RX3
Stat 3 (RX3 only) Wait 5 mins, perform step 1, then press

PROG + CH3 on RX3

www.danfoss.com/BusinessAreas/Heating

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>