Greengate ONW-D-1001 Wall Switch Sensor
Product Information
Specifications
- Mechanical Mounting Plate/Strap Dimensions: 4.195 H x 1.732 W (106.55mm x 44mm)
- Product Housing Dimensions: 2.618 H x 1.752 W x 1.9 D (66.5mm x 44.5mm x 48.26mm)
- Voltage: 120/277 VAC, 50/60 Hz
- Color Options: W=White, V=Ivory, LA=Light Almond, G=Gray, B=Black, R=Red
- Warranty: Five-year warranty standard
Product Usage Instructions
- Turn off the power to the electrical circuit you will be working on.
- Remove the existing wall switch cover plate and switch.
- Follow the provided wiring diagrams to connect the new switch sensor.
- Mount the sensor on the wall using the included mounting plate/strap.
- Secure the sensor in place and attach the cover plate.
- Turn the power back on and test the sensor.
- The sensor combines PIR and Ultrasonic technologies for accurate motion detection.
- Use the DIP switches to adjust settings such as time delay and sensitivity.
- The sensor can self-adjust based on user behavior or be manually configured.
- The ON/OFF button allows for manual control or override of the sensor.
FAQ
- Q: Does the sensor require a neutral wire for installation?
- A: No, the sensor does not require a neutral wire for installation, making it ideal for retrofit applications.
- Q: What is the warranty period for this product?
- A: The product comes with a standard five-year warranty.
Greengate
ONW-D-1001 Wall Switch Sensor with Ground Required
- Dual Tech, Single Pole, 120/277/347 VAC
- Wall Switch Occupancy Sensor (Ground Required)
Typical Applications
- Office
- Small Conference Rooms
- Lunch/Break Rooms
- Classrooms
- Restrooms (1-2 Stalls)
- Lounges
- Waiting Rooms
- Closets
- Storage Areas
Product Certification
Product Features
Overview
The Dual Technology Single Level Occupancy Sensing Wall Switch is a motion-
sensing lighting control and conventional wall switch all-in-one that is used
to for energy savings and convenience. It does not require a neutral wire for
installation making it ideal for retrofit applications.
The ONW-D-1001-MV combines Ultrasonic (US) and Passive Infrared (PIR) sensor
technologies to monitor a room for occupancy to deliver maximum energy savings
and ensure the greatest sensitivity and coverage for tough applications
without the threat of false triggers. PIR is used to turn the lights ON and
then either or both technologies are used to keep the lights ON. In Automatic
On Mode, the lights turn ON automatically when a person enters the room. In
Manual On Mode, the lights are turned ON by pressing the universally
recognized light icon pushbutton. The sensor includes self-adaptive technology
that continuously self-adjusts sensitivity and time delay in real time,
maximizing the potential energy savings that are available in the particular
application.
Top Product Features
- Air-gap switch ensures no leakage current to load
- Selectable built-in light level sensor
- NEMA WD7 Guide robotic method utilized to verify coverage patterns
- LED Rated
Order Information
- SAMPLE ORDER NUMBER: ONW-D-1001-MV-W One single gang wallplate included.
Catalog Number
Catalog Number | Ratings | Coverage | Voltage | Color |
---|
ONW-D-1001-MV- (-W, V, LA, G, B, R)
| Incandescent: 0-800W @ 120V Fluorescent: 0-1200W @ 120V Fluorescent: 0-2700W @ 277V Max Load/Relay| ****
180°; 1000 sq. ft.
| ****
120/277 VAC, 50/60 Hz
| ****
W=White, V=Ivory, LA=Light Almond, G=Gray, B=Black, R=Red
| | | | Notes
Not all colors are available in stock and some color options may have extended lead times.
- SAMPLE ORDER NUMBER: ONW-D-1001-347-W
- One single gang wallplate is included. Wallplate not included with 347 VAC Model.
Catalog Number | Ratings | Coverage | Voltage | Color |
---|
ONW-D-1001-347- (-W, V, LA, G, B, R)
| Incandescent: 0-1500W @ 347V Fluorescent: 0-1500W @ 347V Max Load/Relay|
180°; 1000 sq. ft.
| ****
347 VAC, 50/60 Hz
| ****
W=White, V=Ivory, LA=Light Almond, G=Gray, B=Black, R=Red
| | | | Notes
Not all colors are available in stock and some color options may have extended lead times.
Product Specifications
Technology
- Passive Infrared (PIR) and Ultrasonic (US) technology
Mechanical
- Mounting Plate/Strap Dimensions: 4.195” H x 1.732” W (106.55mm x 44mm)
- Mounting Plate/Strap Dimensions: ONW-D-1001-347: 4.35” H x 1.732” W (110.49mm x 44mm)
- Product Housing Dimensions: 2.618” H x 1.752” W x 1.9” D (66.5mm x 44.5mm x 48.26mm)
- Environment:
- Operating temperature: 32°F to 104°F (0°C to 40°C)
- Relative humidity operating: 20% to 90% non-condensing
- For indoor use only
- Housing: Durable, injection-molded housing. ABS resin complies with UL 94V-0
- Mounting: Fits in a standard 3.5” deep back box Can be mounted in multiple gang back boxes Refer to NEC box calculation for a properly sized mounting box
Electrical
- Electrical ratings (per relay):
- 120 VAC
- Incandescent / Tungsten max load: 6.7 amps, 800W, 50/60 Hz
- Fluorescent / Ballast max load: 10 amps, 1200W, 50/60 Hz
- Electronic Ballast (LED): 3A
- Motor Load: 1/4 HP @ 125 VAC
- 277VAC
- Fluorescent / Ballast max load: 9.8 amps, 2700W, 50/60 Hz
- Electronic Ballast (LED): 3A
- 347VAC
- Fluorescent / Ballast max load: 4.3 amps, 1500W, 50/60 Hz
- Electronic Ballast (LED): 3A
- Ballast compatibility:
- LED loads
- Magnetic and Electronic ballasts
Hardware Specifications
- LED Indicators:
- Red LED = PIR detection
- Green LED = Ultrasonic detection
Controls and Performance
- Time delays:
- Self-adjusting 15 seconds/test (10 min. Auto)
- Selectable 5, 15, 30 minutes
- Coverage:
- Major motion: 36’ x 30’
- Minor motion: 20’ x 16’
- Light sensing level:
- 0 to 200-foot candles
Standards/Ratings
- cULus Listed – Energy Management Equipment (UL916)
- FCC Compliant
- RoHS Compliant
Warning
- This product is not intended to be used in applications involving the use of ammonia-based or VOC cleaners.
- Use of ammonia-based or VOC cleaners on this device must be avoided.
- Prolonged use may cause loss of integrity and expose electrified components.
- If this occurs, turn OFF the power to the unit and replace it.
- For detailed cleaning guidelines please refer to: Controls Care and Maintenance instructions at the end of this document.
Warranty
- Five-year warranty standard
Dimensional and Mounting Details
Scale or Mounting Height
Wiring Diagrams
Single Level Switching – Single Circuit
-
Three-way wiring diagram: Lights will turn OFF automatically when the sensor that detected motion last, times out.
-
For 347 VAC wiring diagrams refer to Installation Instructions
Controls
Field of View
- Maximum coverage area may vary somewhat according to room shape and the presence of obstacles.
Controls Care & Maintenance
Cooper Lighting Solutions
- Cooper Lighting Solutions has developed recommended guidelines for cleaning our products that will not impact the operation or finish of the product.
Recommended cleaning tips
- Never spray any fluids directly into the device.
- The use of ammonia-based or VOC cleaners on this device must be avoided. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF the power to the unit and replace it.
- Use a damp rag or single-use wipe to avoid excess liquid penetrating the device.
- Be sure to wipe up the remaining excess liquid after cleaning.
- Ensure the cleaning agent used does not have harsh chemicals such as bleach, ammonia, highly alkaline or concentrated acids (such as hydrochloric acid that can be found in household cleaners such as toilet bowl cleaners, bathroom tile, and porcelain cleaners) as they could damage the device, causing them to become brittle and discolored.
- Cooper Lighting Solutions recommends the use of a mild liquid detergent and water to clean the devices. Single-use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however, the single-use wipes cannot contain bleach, ammonia, or highly alkaline or concentrated acids.
WARNING
- This product is not intended for use in applications involving the use of ammonia-based or VOC cleaners.
- Prolonged use may cause loss of integrity and expose electrified components.
- If this occurs, turn OFF the power to the unit and replace it.
Recommended cleaning instructions
- Never spray any fluids directly into the device.
- Apply the mild liquid detergent to a damp cloth or paper towel. Single-use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however, single-use wipes cannot contain bleach, ammonia, or highly alkaline or concentrated acids.
- If excess liquid is present, remove it by wringing out the cloth or paper towel to avoid liquid penetration into the device.
- Clean the Cooper Lighting Solutions device by wiping over the surface with a damp cloth.
- Remove the excess liquid remaining on the device with a dry cloth or paper towel.
CONTACT
Cooper Lighting Solutions
- 1121 Highway 74 South
- Peachtree City, GA 30269
- P: 770-486-4800
- www.cooperlighting.com
- For service or technical assistance:
- 1-800-553-3879
Canada Sales
- 5925 McLaughlin Road
- Mississauga, Ontario L5R 1B8
- P: 905-501-3000
- F: 905-501-3172
© 2024 Cooper Lighting Solutions All Rights Reserved.
Product availability, specifications, and compliances are subject to change
without notice.