ROLO CENTRAL HEATING INSTALATION INSTRUCTIONS
Determine Correct Orientation for Installation
Removable stickers on the product will indicate which way up you need to
install, as follows:
– TOP if C/Heating – (Vertical Bar Orientation)
– TOP if C/Heating – (Horizontal Bar)
In CENTRAL HEATING installation you will require the threaded plug found in
the bracket box and an 8 mm Allen Key (not supplied). This threaded plug will
act as a flow diverter, forcing the flow of the water up and over inside the
radiator, to achieve even heat distribution of all bars.
Where to install the threaded plug
When the product is to be mounted portrait the threaded plug will need to be
screwed in on the FLOW side. When portrait you can choose to have the flow on
the left or right hand side.
IMAGE A : The plug is screwed in on the left hand side, where the flow is
coming in.
When the product is to be mounted landscape the threaded plug needs to be
screwed into the left hand side of the radiator.
IMAGE B: This will force the water efficiently around the radiator
whether the flow is coming from the left or the right hand side.
Fully Balance System
The radiator has big capacity, before commissioning bleed the heating system
and check the pressure in the system