AOC Q27G4XY Bluetooth Voice Remote Control User Manual
- August 11, 2024
- AOC
Table of Contents
- Q27G4XY Bluetooth Voice Remote Control
- Specifications:
- Product Usage Instructions:
- Visual Inspection:
- Mechanical Specifications:
- Electronic Specifications:
- Environmental Specifications:
- Q: How do I pair the remote with my device?
- Q: What should I do if the remote stops responding?
- Q: Can this remote control multiple devices?
Q27G4XY Bluetooth Voice Remote Control
“`html
Specifications:
-
Model: AOC Q27G4XY Bluetooth Voice Remote
Control -
Connectivity: IR, BLE, Voice
-
Dimensions: 162.0mm (L) x 43.2mm (W) x 20.7mm
(H) (including key height) -
Weight: Approximately 75g (Batteries
excluded) -
Battery Type: 2 AAA
Product Usage Instructions:
Visual Inspection:
Check the overall dimensions, case material, rubber keypad
material, and ensure there are no scratches or major damages on the
remote.
Mechanical Specifications:
Ensure the key operating force, key stroke, rubber key press,
and rubber strength meet the required specifications. Press buttons
to feel a clear click. Perform drop tests and battery cover life
tests as described.
Electronic Specifications:
Verify the carrier frequency, infrared coding format, operating
voltage, leakage current, and operating current. Refer to the
keycode table for key functions. Ensure the IR and RF ranges are
within specified limits.
Environmental Specifications:
Operate the remote within the specified temperature range and
store it appropriately. Perform reliability tests to check
electrical and mechanical characteristics.
Frequently Asked Questions (FAQ):
Q: How do I pair the remote with my device?
A: To pair the remote via Bluetooth, press and hold the
designated pairing button until the LED indicator blinks. Then,
search for the remote on your device and complete the pairing
process.
Q: What should I do if the remote stops responding?
A: Try replacing the batteries with new ones and ensure they are
inserted correctly. If the issue persists, reset the remote by
removing and reinserting the batteries after a few seconds.
Q: Can this remote control multiple devices?
A: Yes, this remote can be programmed to control multiple
devices by following the device-specific programming instructions
provided in the user manual.
“`
Bluetooth voice remote control User Manual
Table of Contents
No. 1
Cover page
Contents
2 Table of contents
3 Revision History
4.1 General information
4.2 Visual specification
4 4.3 Mechanical specification
4.4 Electronic specification
4.5 Environmental specification
Reliability tests
5.1 Electrical Characteristics 5
5.2 Mechanical Characteristics
5.3 Environmental Test
6.1 Product Artwork
6 6.2 Keycode Table
6.3 Product Packaging
PAGE
1 2 3 3 3-4 4-5 5
5 5-8 8-9 10 11
1
4.1 General information
Purpose
Product Main Feature
AOC Q27G4XY This document contains the requirements for the AOC Q27G4XY remote
IR, BLE, Voice
4.2 Visual specification
No. 1 2
3
4 5 6 7 8
Check Item
Overall dimension
Case material
Rubber keypad material
Scratch
Number of keys
Assembly Plastic visual Printing visual
/ Description/Specification Dim162.0 (L) x 43.2mm (W) x 20.7mm (H) (including
key height)
ABS
Rubber
0.3 No major scratch observed at 0.3m distance
21keys
No moving parts inside the unit , , No visual of scratch, crack, contamination
and deformation Printings and Indications are the same as drawing
4.3 Mechanical specification
No. 1 2 3 4
5
6
7
Check Item Key operating force Key stroke Rubber key press Rubber strength
Key operating life
Button operating feel
Drop Test Height
2.5N±0.5N
/ Description/Specification
0.2~1.0mm
Key should return fast after key released 3kgf 3 , No change after 3 seconds
pressed with 3kgf 5N 30 Key should be okay after test it under 5N by 300,000
times
When pressing buttons, there shall have a clear click feeling
1M
3
8
Compression strength
9
Battery cover life
100N 15
After inserting batteries, press both front and back of the remote with 100N
force for 15 seconds, No impact with the appearance and function.
3 100 Pull out and insert battery cover 3 times per minute for more than 100
times
10
Weight
Appr.75g (Batteries excluded)
11
No. of battery
12
Battery Type
2 AAA
4.4 Electronic specification
No. 1 2 3
4
5
6
Check Item Carrier frequency Infrared coding format Operating Voltage
Leakage current
Operating current
Key Function
38KHz ±2%
/ Description/Specification
NEC
DC 2.4-3.2V
Standby current 10uABefore BT Paired Standby current 3mAAfter BT Paired Deep
sleep current 35uA IR 40mA Bluetooth button10mA Bluetooth Voice15mA
Refer to 6.2 the key code page
1. Straight line 40µW/cm2distance10m
7
IR Range and angle
2. RC side±15°up and downleft and right20µW/cm2distance8m 3. RC side±30°downleft and right5m
8
RF RF range
1. Keys10m 2. Voice7.2m
: Note: This specification cannot be used as the final evaluation standard. It
needs to test and verify after the host was provided by customer.
4
4.5 Environmental specification
No. 1
2
Check Item
Operating Temperature
Storage temperature
0°C~40°C -25°C~60°C
/ Description/Specification
5. Reliability testing
5.1 Electrical Characteristics
No. 1
Check Item
Contact Resistance
2
ESD
Electric-Static Discharge Test
Test condition 200g 1mm Load 200g at the center of the key and the conducting
resin and button should be tested at intervals of 1mm
±15KV B ±8KV B
Judgment
2000
BRC
Pass AIR ±15KV Class B and Contact ±8KV Class B (IEC6100-4-2-2008 Level 4)
Class B: No functional failures and no parts should suffer damage. RC must recover to full function without removal of batteries or reset
5.2 Mechanical Characteristics
No. 1 2 3
4
5
Check Item
Operating Force
Return Force Matching test of key and upper cover Overweight test
Vibration test
Test condition 4mm Press the key with a diameter 4mm pin and measure the
operating force
4mm Press the key with a pin of diameter 4mm and measure the return force
1.0kgf, 1 Apply 1.0kgf to upper, lower, left and right of the key for 1 minute
29.4N(3.0kgf), 3 Apply 29.4n (3.0kgf) in the vertical direction and in the
center of the key for 3 seconds
:30-50-30Hz 0.75mm,5 Vibration in vertical direction: Frequency: 30-50-30hz
Judgment
2.5N±0.5N
0.4N
The upper cover cannot get stuck by the key PCB No functional failures and no parts should suffer damage. ,PCB No functional failures and no parts should suffer damage.
5
6
Key life test
Displacement: 0.75mm Axis frequency sweep 5 cycles , Keys:
Up,Down,Left,Right,OK,Vol+/-,Ch+/-,Power,Home,Back) (1). : 200g (2). : 80-90 /
(3). : 300,000 Remote control without batteries and each key is tested under
the following conditions at the same time (Keys:
Up,Down,Left,Right,OK,Vol+/-,Ch+/-,Power,Home,Back): (1) Operating force: 200g
(2) Speed: 80-90 times / minute (3) Times: 300,000 times ,
(1). : 200g
No functional failures and no parts should suffer damage.
(2). : 20-30 /
(3). : 100,000
Remote control with batteries and select any key to test under the following
conditions: (1) Operating force: 200g (2) Speed: 20-30 times / minute (3)
Times: 100,000 times
(1) Press-sensitive type, Brand Name: Eagle 45 20
(1) Use tapepress-sensitive type, Brand Name: Eagleto attach the surface of
text printing, and quickly lift the tape up to 45 degrees;
7
Repeat 20 times Printing and (2) 95 500gf 200
The text printing is still clear
Painting test
(2) Use the cotton with 95% alcohol and load 500gf to wipe
the printing surface 200 times
(3)Pentel ZEH500gf200
(3)USE the eraserPentel ZEHand load 500gf to wipe the printing surface 200 times
1.2m ()
,
,PCB
324561
No permanent damage and no
3(bottom)2(face)4(Left side)5(Right side)6(back) functional failure allowed.
8
Drop test
1(eradiate side) , /
(Plywood), 2.5cm
Batteries and Battery Lid are allowed to fall out during the test.
Fall on the wood board (including battery) from 1.2m
height. The falling surface of the remote control shall be
parallel to the impact surface. The impact surface shall be
horizontal, flat, solid and hard, so that it will not move
or deform during the test. Drop the test surface in the order
6
of 3 2 4 5 6 1 Note: 3 (bottom), 2 (face), 4 (left side), 5(right side), 6
(back), 1 (eradiate side)
NoteThe specifications of the wood board are subject to
confirmation by the manufacturer and make a tentative arrangement to Plywood
which thickness is 2.5cm
9
Battery cover opening test
/100 Installed/removed the battery cover for 100 times.
10
Battery Insertion
/100, Install/remove the battery 100 times. Press the power key every time to check whether the function is normal
1. 2. 3. 1. Easy to install without tools 2. There shall be no crack or
fracture on the appearance 3. The cover shall not fall off easily
,
1. Confirm whether the battery power is on or off 2. Confirm whether the
springs is off
11
Static load test
12 Sharp Edge Test
157N()1 Load 157N force(static) to both the top side and the other side of a
commander for 1 minute.
Tester Devices: 1. Tester : UL Approved Sharp Edge Tester SET-50. 2. Tape :
Inner layer = 3M Japan Limited sole mat No. 5900 (Thickness = 0.06mm).
Outer layer = 3M Japan Limited sole mat No. 5900 (Thickness = 0.06mm).
Checking Method: Move the sharp edge tester back & forth over a distance 50mm
(total distance 100mm). Mount the UL-prescribe red “tape cap” to the tip of
sharp edge tester. The edge should be passed with any angle of sharp edge
tester.
At least, evaluate at 3 kinds of angle without Protection Film. 45° 0° Worst
Angle based on finger feeling at every time.
1. 2. (=) 3. PCB 1. All functions operate normally. 2. There is no cosmetic
damage (=crack) 3. There is no PCB crack.
: Sharp Edge Criteria: If there is any cuts or splits on both inner & outer
layers after sliding, the edge should be rejected.
7
13 Battery door
opening force
RC is fixed securely to a horizontal surface.
A hole is drilled in the exact center of the battery door.
Force gauge pin of diameter 2-6mm and length 9mm is inserted into the hole.
Force gauge is placed on a movable jig.
Using a screw method to push the push gauge forward
until the battery door is dislodged. The force to dislodge battery door is
recorded.
5.3 Environmental Test
No. 1
2
3 4
Check Item
Low temperature Test
High temperature Test
Humidity test
Temperature cycles
Test condition -25±296 11
Without battery, put the remote control with
25±2 temperature and keep 96 hours, then take it to normal temperature and
normal humidity for 1 hour, then check within 1 hour 60±2 96 1 1 Without
battery, put the remote control with 60±2 temperature and keep 96 hours, then
take it to normal temperature and normal humidity for 1 hour, then check
within 1 hour 40±2 90-95% 168 1 1 With battery, put the remote control with
40±2 temperature and relative humidity 90-95%, keep 168 hours, then take it to
normal temperature and normal humidity for 1 hour, then check within 1 hour
(1):-25~+70
8
Judgment No functional failures and no parts should suffer damage.
No functional failures and no parts should suffer damage.
No functional failures and no parts should suffer damage.
No functional failures and no parts
test
(2):-252+70210 should suffer damage.
(3)11
Without battery and test the remote control under the following conditions
(1) Temperature:25 ~70
(2)Time :25 2 hours, 70 2hours,cycle
10 times (3) Take it to normal temperature and normal humidity for 1 hour,
then check within 1 hour
5
5% 72 Salt spray test of Soak in 5% Salt water for 72 hours
battery spring
No rust
RC 50ml RC
6 Liquid test
5 48
Pour 50ml of liquid over the RC. Immediately turn the RC in such way that most
liquid will be removed and using tissue paper or cloth to absorb out the
liquid stain that is residual in the gap. Test the product after 5mins. Dry it
for 48 hours at room temperature, then test the product again.
RC RC must be functional during tests.
Liquids to be tested: 1. 5% salt water 5% 2. Edible Oil 3. 60 water 60 4. Coffee.
9
6.1 Product Artwork
10
6.2 Keycode Table
11
FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation. 2. any
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced radio/TV
technician for help. FCC Radiation Exposure Statement This equipment complies
with FCC radiation exposure limits set forth for an uncontrolled environment.
DÉCLARATION DE LA FCC 1. Cet appareil est conforme à la partie 15 des règles
de la FCC. L’exploitation est soumise aux deux conditions suivantes : (1) Cet
appareil ne peut pas causer d’interférences nuisibles, et (2) Cet appareil
doit accepter tout le brouillage reçu, y compris le brouillage qui peut causer
un fonctionnement indésirable. 2. Tout changement ou modification non
expressément approuvé par la partie responsable de la conformité pourrait
annuler le pouvoir de l’utilisateur d’utiliser l’équipement. REMARQUE : Cet
équipement a été testé et déclaré conforme aux limites d’un numérique de
classe B conformément à la partie 15 des règles de la FCC. Ces limites sont
conçues pour fournir une protection raisonnable contre les interférences
préjudiciables dans un installation résidentielle. Cet équipement génère,
utilise et peut émettre de l’énergie radiofréquence et, s’il n’est pas
installé et utilisé conformément aux instructions, peut provoquer des
interférences nuisibles aux communications radio. Cependant, il n’y a aucune
garantie que des interférences ne se produiront pas dans une installation
particulière. Si cet équipement provoque des interférences nuisibles à la
réception de la radio ou de la télévision, ce qui peut être déterminé en
éteignant et en rallumant l’équipement, l’utilisateur est encouragé à essayer
de corriger le l’interférence d’une ou de plusieurs des mesures suivantes :
Réorientez ou déplacez l’antenne de réception. Augmenter la distance entre
l’équipement et récepteur. Branchez l’équipement sur une prise sur un circuit
différent de celui auquel le récepteur est connectée. Consultez le revendeur
ou un technicien radio/TV expérimenté pour obtenir de l’aide. Déclaration
d’exposition aux rayonnements de la FCC Cet équipement est conforme aux
limites d’exposition aux rayonnements de la FCC établies pour un
environnement.
4
ISED Statement This device contains licence-exempt transmitter(s)/receiver(s)
that comply with Innovation, Science and Economic Development Canada’ s
licence-exempt RSS(s). Operation is subject to the following two conditions:
1.This device may not cause interference. 2.This device must accept any
interference, including interference that may cause undesired operation of the
device. Le présent appareil est conforme aux CNR d’Industrie Canada
applicables auxappareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1)l’ appareil ne doit pas produire
de brouillage, et (2) l’utilisateur de l’appareil doit accepter toutbrouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre
lefonctionnement. L’appareil a été évalué pour répondre aux exigences
générales d’exposition aux RF. L’ap pareilpeut être utilisé dans des
conditions d’exposition portable sans restriction.
5
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>