VORTEX VX4 4 Poles Submersible Pump Owner’s Manual
- August 11, 2024
- VORTEX
Table of Contents
VORTEX VX4 4 Poles Submersible Pump
Specifications:
- Product Name: VX4 Submersible Pump – 4 POLES
- Type: Submersible Pump 4 poles (1450 min-1)
- Usage: Vortex, Sewage, Civil, Industrial
- Electric Motor: Three-phase with integrated thermal protector
- Power Cable Length: 10 meters
Product Usage Instructions
Electric Motor Safety:
The electric motor is equipped with a three-phase thermal protector to
prevent overheating or abnormal power consumption.
Application Limits:
Ensure the power cable is appropriately sized for the application.
Available Options:
Upon request, the product is available with different voltage requirements
and 60 Hz frequency.
Dimensions and Weight:
- VX4-10/50: 106mm x 193mm x 602mm, Weight: 47.3kg
- VX4-10/65: 107mm x 196mm x 630mm, Weight: 50.6kg
- VX4-10/80: 107mm x 210mm x 655mm, Weight: 52.1kg
FAQ:
-
Q: What is the voltage requirement for the VX4 submersible pump?
A: The voltage requirement is 400V for all models (VX4-10/50, VX4-10/65, VX4-10/80). -
Q: What materials are used in the construction of the pump components?
A: The pump body is made of cast iron, impeller is cast iron VORTEX type, motor sleeve is stainless steel AISI 304, motor cover is cast iron, and motor shaft is stainless steel AISI 431. -
Q: Does the product come with a warranty?
A: Warranty information may vary. Please refer to the manufacturer’s warranty policy or contact customer support for details.
PERFORMANCE RANGE
- Flow rate up to 900 l/min (54 m3/h)
- Head up to 7 m
INSTALLATION AND USE
The VX4 series is constructed from thick cast iron, offering exceptional
robustness, abrasion resistance, and longevity. Equipped with VORTEX-type
impellers, known for their reliability and minimal clogging risk, these pumps
are versatile for handling sewage with suspended solids up to 80 mm in
diameter, as well as wastewater, rainwater, city sewage, and industrial
wastewater. They are suitable for a wide range of applications, including
sewers, tunnels, excavations, canals, and underground parking facilities.
ELECTRIC MOTOR
The electric motor is safeguarded by a special three-phase thermal protector,
situated within the motor, which activates in case of overheating or abnormal
power consumption.
INCLUDES
Power cable length 10 m
APPLICATION LIMITS
- Depth below water level up to 10 m (with an appropriately sized power cable)
- Liquid temperature up to +40 °C
- Suspended solids transfer:
- up to Ø 50 mm for VX4-10/50
- up to Ø 65 mm for VX4-10/65
- up to Ø 80 mm for VX4-10/80
- Minimum immersion for continuous service: 500 mm
AVAILABLE UPON REQUEST
Different voltage requirements 60 Hz frequency
PATENTS – TRADE MARKS – MODELS
- Registered Community Model No. 003863158-0002
CURVES AND PERFORMANCE DATA – n= 1450 min-1
50 Hz
TYPE
Three- phase| POWER ( P2 )| Q| m³/h| 0| 6| 12| 24|
30| 34.5| 36| 45| 54
---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 100| 200| 400| 500|
575| 600| 750| 900
VX4- 10/50| 0.75| 1| H metres| 7| 6.4| 5.8| 5| 4| 2.5| 1| |
VX4- 10/65| 0.75| 1| 6| 6| 5.6| 5| 4.4| 3.8| 3.3| 2| 1
VX4- 10/80| 0.75| 1| 5.5| 5.3| 4.9| 4.5| 3.9| 3.4| 2.9| 1.8| 1
Q = Flow rate H = Total manometric head
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
ABSORPTION
TYPE
Three- phase| VOLTAGE
400 V
---|---
VX4- 10/50| 2.7 A
VX4- 10/65| 2.7 A
VX4- 10/80| 2.7 A
DIMENSIONS AND WEIGHT
TYPE
Three- phase| Passage of solid bodies| DIMENSIONS mm| kg
3~
---|---|---|---
a| b| c| h| h1| d| p| **
VX4- 10/50| Ø 50 mm| 170| 106| 193| 602| 100| 55| 700| 500| 47.3
VX4- 10/65| Ø 65 mm| 170| 107| 196| 630| 121| 70| 800| 500|
50.6
VX4- 10/80| Ø 80 mm**| 178| 107| 210| 655| 150| 85| 800| 500|
52.1
PORT FLANGE
TYPE
Three- phase| FLANGE
DN| F| K
mm| D
mm| HOLES
---|---|---|---|---|---
N°| Ø (mm)
VX4- 10/50| 50
(PN10)| 2″| 125| 150| 4| 18
VX4- 10/65| 65
(PN10)| 2½”| 145| 185| 8| 18
VX4- 10/80| 80
(PN10)| 3″| 160| 200| 8| 18
PALLET CAPACITY
TYPE
Three- phase| NO. OF PUMPS
---|---
VX4- 10/50| 12
VX4- 10/65| 12
VX4- 10/80| 12
MATERIALS AND COMPONENTS
-
Pump body
Cast iron with cataphoresis treatment -
Impeller
Cast iron VORTEX type with cataphoresis treatment -
Motor sleeve
Stainless steel AISI 304 -
Motor cover
Cast iron with cataphoresis treatment -
Motor shaft
Stainless steel AISI 431 -
Double mechanical seal with interposed oil chamber
Seal| Shaft| Location| Materials
---|---|---|---
AR- 27| Ø 27 mm| Motor side| Silicon carbide / Graphite / NBR
AR- 25| Ø 25 mm| Pump side| Silicon carbide/Silicon carbide/NBR -
Electric Motor
Three-phase 400 V – 50Hz
with winding integrated thermal three-phase motor protection- Insulation: class F
- Protection rating: IP X8
-
Power cord
※ 10 metres ‘H07 RN-F’ type
SEWAGE LIFTING SYSTEM VX4 – BC4
VERSION WITH HORIZONTAL DELIVERY AND ¾” GUIDE PIPES
For VX4 /50 | Code ASSPVX50 | DN 2 |
---|
Kit consisting of:
VERSION WITH VERTICAL DELIVERY AND ¾” GUIDE PIPES
For VX4 /50 | Code ASSPVX503V | DN 2½” |
---|---|---|
For VX4 /65 | Code ASSPVX653V | DN 3″ |
For BC4 /50 | Code ASSVXCF071V |
VERSION WITH VERTICAL DELIVERY AND 2″ GUIDE TUBES
For VX4 /50 | Code ASSPVX50V | DN 3″ |
---|---|---|
For VX4 /65 | Code ASSPVX65V | |
For VX4 /80, BC4 /50 | Code ASSVXCF0705V |
Kit consisting of:
ACCESSORIES AVAILABLE FOR ORDER
RUNNING GUIDE
※ For VX4 /50 with Ø ¾” guide tubes | Code ASSFL009 |
---|---|
※ For VX4 /65 with Ø ¾” guide tubes | Code ASSFL010 |
※ For BC4 /50 with Ø ¾” guide tubes | Code ASSFL0018 |
※ For VX4 /50 with Ø 2″ guide tubes | Code ASSFL050 |
※ For VX4 /65 with Ø 2″ guide tubes | Code ASSFL065 |
※ For VX4 /80, BC4 /50 with Ø 2″ guide tubes | Code ASSFL072 |
Complete with screws and seals
INTERMEDIATE GUIDE TUBE SUPPORT
※ For Ø ¾” guide tubes | Code 859SV340INTFA |
---|---|
※ For guide tubes Ø 2″ | Code 859SV349INTFA |
For reasons of stability, an intermediate support should be interposed:
- every 2 metres with ¾” guide pipes (mandatory)
- every 3 metres with 2″ guide tubes (recommended)
GUIDE TUBE (AISI 304 stainless steel)
※ 2 metres Ø ¾” guide tube | Code 54SARTG0052F |
---|---|
※ 3 metres Ø ¾” guide tube | Code 54SARTG0053F |
※ 6 metres Ø ¾” guide tube | Code 54SARTG0056F |
※ 3 metres Ø 2″ guide tube | Code 54SARTG0063F |
※ 6 metres guide tube Ø 2″ | Code 54SARTG0066F |
DIMENSIONS (HORIZONTAL delivery version)
DIMENSIONS (Version with VERTICAL delivery)
Version with ¾” guide tubes
TYPE| Solid bodies
mm| PORT
DN
| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| Øg| Øm| Øn| Ør
VX4 /50| Ø 50 mm| 2½”| 211| 61| 52| 125| 165| 506|
28| 164| 216| 120| 72| 62| 3| 50| ¾”| 14| 11| 18
VX4 /65| Ø 65 mm| 3″| 213| 69| 150| 190|
537| 48| 216| 280| 130| 112| 84| ** 15
BC4 /50| Ø 50 mm**| 222| 553| 19
Version with 2″ guide tubes
TYPE| Solid bodies mm| PORT
DN| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| i6| Øg| Øm| Øn| Ør
VX4 /50| Ø 50 mm| **3″| **
319
| 86| 95| 160| 200| 706| 107| 264| 392|
250| 150| 34| –| 80| 186| 2″|
22| 13.5| 18
VX4 /65| Ø 65 mm| 697| 86
VX4 /80| Ø 80 mm| 328| 714| 57
BC4 /50| Ø 50 mm| 328| 714| 57
References