Air-O-Swiss AOSE2441 Air Cleaner Owner’s Manual
- August 11, 2024
- Air-O-Swiss
Table of Contents
- AOSE2441 Air Cleaner
- Specifications
- Product Information
- Product Usage Instructions
- About this document
- Safety Instructions
- Putting the unit into operation
- Cleaning and Servicing
- Transporting and Storing
- Q: Can I use fragrances or water conditioners with the
- Q: What should I do if the unit overflows?
- Q: What are the warning levels in the manual?
AOSE2441 Air Cleaner
“`html
Specifications
- Model: Air-O-Swiss AOSE2441
- Operating Language: English
- Power Cord Length: 4ft
- Dimensions: 1ft
Product Information
The Air-O-Swiss AOSE2441 is a humidifier designed to improve air
quality by adding moisture to the air in living spaces. It features
a humidification system that helps maintain an optimal humidity
level for a comfortable environment.
Product Usage Instructions
About this document
The provided document includes safety instructions, technical
data, description of the unit, unpacking guidelines, operation
procedures, cleaning and servicing steps, transportation and
storage instructions, spare parts information, and FAQs.
Safety Instructions
Follow the warning levels provided in the manual to ensure safe
usage of the product. Pay attention to symbols indicating possible
dangers and necessary precautions to prevent injuries or material
damage.
Putting the unit into operation
Before operating the unit, make sure to read and understand all
safety instructions and warnings. Only use the unit for its
intended purpose of humidifying the air in living spaces. Do not
put foreign objects or substances into the unit.
Cleaning and Servicing
Regularly clean and service the unit as per the instructions in
the manual to ensure optimal performance and longevity. Avoid using
additives or substances not recommended by the manufacturer.
Transporting and Storing
When transporting the unit, handle it with care to prevent
damage. Store the unit in a safe place when not in use, following
guidelines provided in the manual.
FAQs
Q: Can I use fragrances or water conditioners with the
Air-O-Swiss AOSE2441?
A: The unit is not suitable for the use of additives like
fragrances or water conditioners. Avoid using any substances that
are not recommended by the manufacturer.
Q: What should I do if the unit overflows?
A: Check the float tip as it may be causing the overflow. Ensure
it is functioning correctly to prevent any issues with water
overflow.
Q: What are the warning levels in the manual?
A: The warning levels include WARNING for possible danger
resulting in death or serious injury, CAUTION for dangerous
situations leading to slight injury, and CAUTION for critical
situations causing material damage.
“`
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Air-O-Swiss AOSE2441 Owner’s Manual
Shop genuine replacement parts for Air-O-Swiss AOSE2441
Find Your Air-O-Swiss Air Cleaner Parts – Select From 3 Models ——– Manual
continues below ——–
READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! ¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!
AOS E2441
Evaporator Évaporateur Evaporatore
Operating instructions English
3
Mode d’emploi Français
8
Instrucciones de Operación Español 13
A1
A2
A3
A
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
4ft
1ft
B3
B B15
B16
B1
B2 B17
B3
B18
B19
B4 B7
B5
B6
B7
B13
B8
B9
B20
B21
B10
B11
B14
B12
B13 B14
B14
C1
C2
C3
C
C4
C5
C6
C7
D1
D2
D
D3
STOP!
E1
E2
E3
E
E4
STOP!
F1
F2
F3
F
F4
F5
F6
G1
G2
G3
G
H1
H2
H3
H
H4
H5
Operating instructions
Therearethefollowingwarninglevels:
· A2 Never pull the power plug out of the
English
Page Chapter
3
About this document
3
Safety instructions
4
Technical data
4
Description of the unit
4
Humidification system
4
Unpacking the unit
4
Putting the unit into operation
5
Switching the unit on and off
5
Cleaning and servicing the unit
6
Transporting the unit
6
Storing the unit
6
Spare parts and accessories
6
Frequently asked questions
7
Air humidification general
information
7
Troubleshooting
About this document
These operating instructions are a compo-
Warning level
WARNING
CAUTION CAUTION
Description
Possibledanger. Non-observancecould resultindeathorseriousinjury.
Dangeroussituation. Non-observancecould resultinslightinjury.
Criticalsituation. Non-observancecould resultinmaterial damage.
Inthisdocument,thefollowingsymbolsareusedto facilitatefastaccesstoinformation:
Symbol
1. 2.
Description Conditionwhichmustbemetbefore beginninganaction Actionwithoneormorestep(s) whoseorderisnotrelevant Actionwithseveralstepswhose orderisrelevant
electricalsocketbythecord. · A3 Neverpullthepowerplugoutoforplug
itintotheelectricalsocketwithwethands. · A4 OnlyplugtheunitintoanACsupply. ·
B14 Operatetheunitonlyatthevoltageac-
cordingtoratingplateontheunit. · Donotoperatetheunit:
– A5 ifcordorplugaredamaged. – followingamalfunction. – A6
ifithasfallendownorhasbeenother-
wisedamaged. · A7 Repairs and changes on electric appli-
ances and cables may only be carried out by specialists. ·
Unplugthepowerplugfromtheelectricalsocket inthefollowingcases:
-beforeeachemptyingtheunit, – beforeeachcleaning, –
beforeeachreplacementoftheevaporatorwick ortheIonicSilverStick®, – before
installing/uninstalling individual components, -beforetakingofftheupperpart,
-beforeeachmoveoftheunit. · A8 Neversubmergethelowerpartwiththe
nent of the product and describe its safe use.
Listingoffirstlevel
electricalpartandfaninwaterorotherliquidsor
The operating instructions apply exclusively to the ·
rinseitoffwithwaterorotherliquids.
productdescribedwithin.
Listingofsecondlevel
· Readthroughtheinstructionsthoroughlypriorto
–
Observe the following precautions to prevent inju-
puttingtheunitintooperation.
Resultofoneormoreactions
ry:
· Save the instructions for use throughout the
· A9 Placetheunitinsuchawaythatyoudo
lifespanoftheproduct.
(see…) Referencetoachapter,aparagraph
nottripoverthecord.
· Passtheinstructionsforuseontoeachsucces-
oradrawing
· Place the unit in such a way that it cannot be
siveowneroroperatoroftheproductandinclude any supplements received from the manufac-
Importantinformation
knockedover. · A10 Donotgetthecordstuckinthedooror
turer. Intended use
Referencetoanitemnumberin
A1
adrawinge.g.itemnumber1in
drawingA
clampitwithotherobjects. · Donotcoverthecord.
Observe the following precautions to prevent ma-
Theunitisonlyintendedtohumidifytheairinliving
terialdamage:
areasupto430sqft/120m³.Inareaslargerthan Safety instructions
· A11 Donotsitontheunitorplaceanyob-
430sq ft / 120m³, optimum air moisture for hu-
jectsonit.
mansandanimalsisnotguaranteed.Theunitmay Theunitisbuiltaccordingtothestate-of- the-artin · A12 Only place the unit on a flat, dry sur-
notbeusedforotherpurposes.Noforeignobjects technology and in accordance with the safety and
face.
maybeputintotheunit.
accidentpreventionregulations.Nevertheless,dan- · The unit’s air inlet and air outlet must be kept
gerscanresultfromitsusewhichcanleadtoinju-
clear.
Applicable standards
riestotheuserandothers,ortodamagetotheunit · Onlyusecleancontainersforfillingtheunit.
orotherpropertyiftheunitisnotusedaccordingto · Ensurethatthewateringcanhasnotbeenfilled
TheunitisETL-listed.Itcomplieswiththefollowing thesesafetyinstructions.
withfertilizerorsimilarsubstances.
standards:
· Priortousingtheappliance,readthroughthein- · Donotfilladditivesintotheunitortheremovable
· UL998
structions for complete use and retain in a safe
waterbase.
· CSAC22.2No.104-01
placeforlaterreference.
· Do not use water additives (e.g. essential oils,
· Thoseunfamiliarwiththeoperatinginstructions
fragrances, water conditioners).The material is
Forfurhterinformationcontact:
as well as children, and people under the influ-
notsuitablefortheuseofadditives.
www.intertek-sc.com
enceofmedicine,alcoholordrugsmaynotoper- · A13 Whentheunitisfilled,donotpushdown
atetheunit.
the float tip since this causes the unit to over-
Warnings and symbols in this document
· The unit may only be operated for its intended
flow.
useandwithinthespecifiedtechnicaldata.Unin- · Operatetheunitonlywhenfullyassembledand
In this document, warnings are used to prevent
tendedusecanbeadangertohealthorlife.
completelyoperational.
injuries and material damage. They are set up as · A1 Childrencannotrecognizethedangerin · Theappliancehasapolarizedplug(onebladeis
follows:
handling electric appliances. Therefore always
wider than the other). To reduce risk of shock,
WARNING LEVEL
supervisechildrenwhoareneartheunit. · Donotusetheunitinroomsinwhichthereare
this plug is intended to fit in a polarized outlet, onlyoneway.Iftheplugdoesnotfitfullyinthe
Cause and result of the danger
flammablegoods,gasesorvapors. · Do not alter the unit or put foreign objects into
outlet,reversetheplug.Ifitstilldoesnotfit,contact a qualified electrician. DO NOT attempt to
Precautionstopreventdanger
theunit.
undothissafetyfeature.
· A loose fit between the plug and the AC outlet
When using electricity, electrical shock poses a
(receptacle)maycauseoverheatingandadistor-
dangertolife.Observethefollowingprecautions:
tionoftheplug.Contactaqualifiedelectricianto
· Donotplacetheunitintherain.
replacelooseorwornreceptacles.
3
· Donotusetheunitindamprooms.
· Unplugthepowerplugwhennotinuse.
Technical data
Electricalvoltage Powerconsumption Humidityoutput
Suitableforrooms
DimensionsLxWxH Weight(empty) Operationnoiselevel
Value 100120V/5060Hz
24W
upto1.4gallons/24hrs upto220g/h
upto430sqft upto40m²
12.6″x12.6″x15.7″ 320x320x400mm
8.4lbs 3.8kg <25dB(A)
Description of the unit
Theunitconsistsofthefollowingcomponents:
· B1 Fillingopening
· B2 Topassembly
· B3 Floatassembly(B1619)
· B4 IonicSilverStick®(ISS)
· B5 Removablewaterbase(B57)
· B6 Watercapacityfillline
· B7 Basehandles
· B8 Spout
· B9 LifecycleindicatorforIonicSilver
Stick®
· B10 Powercord/plug
· B11 Base(B1114)
· B12 Fan
· B13 Slideswitch(B2021)
· B14 Power rating plate (on the underside
oftheunit)
Thefloatassemblyconsistsofthefollowingparts: · B15 Floattip=Waterlevelindicator · B16 Waterlevelindicatorring · B17 EvaporatorwickAOS7018 · B18 Floatbasket · B19 Floatbody(styrofoam)
Theslideswitchconsistsofthefollowingparts: · B20 Slideswitch · B21
Operatinglight
Operating modes
The following operating modes can be set on the slideswitch:
Position 0 I
Function Theunitisswitchedoff Theunitisoperatinginnightmode (lownoiselevel) Theoperatinglightturnsgreen
II
Theunitisoperatinginnormalmode
(maximumhumidityoutput)
Theoperatinglightturnsgreen
Operating light
The green indicator light illuminates when the unit
isswitchedon.Iftheremovablewaterbaseistaken
offthebase,thegreenLEDchangestoredandunit
operationisinterrupted,buttheunitisnotcurrentless. Only when the removable
water base is returnedtothebase,theredLEDturngreenagainand
theunitresumesoperation.
Power rating plate
B14 Among other things the following
informationisdisplayedonthepowerratingplate: · Productname(Modelnumber) ·
Electricalvoltage · Powerconsumption · Signofconformity
Theinformationonthepowerratingplatedisplayedintheillustrationsisonlyanexample.Check
the information displayed on the power rating plateofyourunit.
Humidification system
When filling the unit using the filling opening.The
floattipclosesthefillingopeningassoonasthefill capacity is reached. The
evaporator wick soaks up water.Thefanpushesthedryroomairthroughthe moist wick
and emits it as a sufficiently
moisturizedair.Throughthedirectedguidingoftheairflow, nearly constant
humidification is possible at every water level. Therefore, the unit creates
optimum air moisture, without additional control units being necessary.
Ionic Silver Stick® for water quality maintenance
B4 The specially adapted anti-microbial protection system Ionic Silver Stick®
prevents microbialgrowthintheremovablewaterbase.Therefore, no chemical
additives are necessary for the water qualitymaintenance. TheIonicSilverStick
®isself-renewing,servicefree andcanbeusedforayear.
Lifecycle indicator
B9 Theunitisequippedwithalifecycleindicator for the Ionic Silver Stick®.
Please cross off the current month on the label and write the current
yearonthelineprovided.
Unpacking the unit
Atdeliverytheunitiscompletelyassembledand alreadyequippedwithanevaporatorwick.
The float body is a component of the float assembly and does not belong to the
packaging. Please do not dispose of the float body.This is
notareplaceableaccessory.
CAUTION
Risk of injury by falling parts! Always handle the unit by the base when un-
packingandlifting.
CAUTION
Damage to the unit due to removal of the float body (styrofoam) inside the
unit! C7 Donotremovethefloatbody(styrofoam)
whenunpackingtheunit.
1. Openthepackaging. 2. C1 Removetheupperpartofthestyrofoam
packaging. 3. C2 Reachintothefillingopeningandgrasp
theupperendoftheplasticbagsecurely. 4. C3
Carefullypulltheplasticbagwiththeunit
out of the packaging.When doing so, grasp the
plasticbagsecurelyanddonotletgooftheplasticbagwhenremoving. 5. C5
Placetheplasticbagwiththeunitonthe floor and push the plastic bag down along
the unit. 6. C6 Holdtheunitbythebaseandliftupoutof theplasticbag. A
llpackagingcomponentsaswellastheplastic bagareremovedfromtheunit. 7. B14
Checkdataregardingthepowersupply onthepowerratingplate. 8. B
Checkthatallcomponentsoftheunitare included.
Putting the unit into operation
Positioning the unit
CAUTION
Damage to the plastic due to high temperatures!
Donotexposetheunittotemperatures>122°F/
50°C.
Observethefollowingprecautionswhenpositioning theunit: · A14 Remember to
ensure easy accessibility
and sufficient room for servicing and cleaning theunit. ·
Onlyoperatetheunitwhenitisfilled!
1. Placetheunitonthefloororonaflat,drysurface intheroom.
2. Filltheunit(seesection”Fillingtheunit”).
Filling the unit
There are the following possibilities for filling the unitwithwater: ·
usingthefillingopeningontheupperpartor ·
directlyintotheremovedwaterbasefromafau-
cet.
Therearenoforeignobjectsintheunit. B Theunitisassembledproperly.
4
After an extended period of disuse, the unit
shouldbeemptied.Ensurethattheunitistclean prior to resuming operation.
Otherwise an unpleasantodorcanresult.
CAUTION
Damage and cracks in plastic caused by additives in the water! Do not put any
additives (e.g. essential oils or
otherfragrances)intothewater. Ensurethattherearenowater-solubleadditives
(e.g.plantfertilizer)inacontainerbeforeusingit tofilltheunit.
CAUTION
Water damage due to overfilling! Whenfilling,donotexceedthemaximumfilling
capacityindicatedbythefillingline.
CAUTION
Water leaking from the unit! When the unit is filled, do not press down the
floattip.
Fillingtheunitatthefillingopening: 1. D1 Filltheunitusingacleancontainer(e.g.a
jarorawateringcan). 2. D2 Pour fresh, cold water into the filling
openingoftheupperpartwithacleancontainer. 3. D3
Stopfillingtheunitassoonasthewater
levelindicatorringofthefloatappearsinthetop assembly.
Theunitisfilledwithwaterandcanbeswitched on.
Fillingtheunitattheremovablewaterbase: E1 The unit is switched off and the
power
plug is unplugged (see chapter “Switching the unitonandoff”).
2. Set the slide switch to position I or position II
accordingtoyourneeds(seesection”Operating modes”).
Theunitisswitchedon.
1. Settheslideswitchtoposition0.
WARNING
Danger to life through electrical shock!
Donotunplugtheunitfromtheelectricalsocket
withwethands.
2. E1 Unplugthepowerplug. Theunitisswitchedoffandcurrentless.
Cleaning and servicing the unit
With increasing operating time, the air throughput and evaporator performance
of the evaporator wickdecrease.Therefore,regularmaintenanceand
cleaningoftheunitisarequirementforsmoothand trouble-freeoperation.
CAUTION
Damage to the plastic due to unsuitable cleaning agents!
Donotuseacidiccleaningagents.
Wipetheunitwithadampcloth.
Cleaning and servicing intervals
Recommended cleaning and service intervals dependonairandwaterqualityaswellasactualoperatingtime.
Interval onceaday
1weekor morewithout operation
Activity
Checkthewaterlevel, ifnecessary,refillwater(see chapter”Fillingtheunit”)
Emptyandcleantheunit(see section”Takingapartand emptyingtheunit”)
F1 The unit is switched off and the power plugisunplugged.
1. F3 Lifttheupperpartfromthebase. 2. F4 Remove the removable water base in-
cluding float assembly using the provided base handles. 3. F5
Emptytheresidualwaterfromtheremovablewaterbaseusingthespout. 4. F6
Removethefloatassemblyfromtheemptyremovablewaterbase.
WARNING
Danger to life through electrical shock! Do not empty water over the
electrical part
(base).
5. Ifwaterisinthebase:emptythewateranddry thebase.
Theunitistakenapartandemptied.
Cleaning the removable water base
Unitistakenapartandemptiedfromwater.
Before cleaning the removable water base the
floatassemblyhastoberemovedfromthewater base.
Only use the manufacturer´s recommended cleaning agent EZCal (see chaper
“Spare parts andaccessories”).
WARNING
Danger to life through electrical shock! Unplugtheunitpriortocleaning.
Neversubmergethebasewiththeelectricalpart
andthefaninwater.
CAUTION
Damage to the unit due to the use of the cleaning and decalcification agent
EZCal on the running unit!
1. E2 Lifttheupperpartfromthebase. 2. E3 Lifttheremovablewaterbaseincluding
thefloatassemblybythebasehandles. 3. E4 Fillfresh,coldwaterdirectlyintothere-
movablewaterbase. 4. E4 Onlypourwaterinuntilthemaximumfill
every2weeks
every1012 weeks(oras
Cleantheremovablewater basewithEZCalonly(seesection”Cleaningtheremovable
waterbase”)
Replacetheevaporatorwick (seesection”Replacingthe
Before using EZCal, switch off and unplug the unit.
AftertheuseofEZCal,rinsethebasethoroughly withtapwater.
Before switching on the unit, ensure that there arenoresiduesofEZCalinthebase.
capacityontheinnersideoftheremovablewater needed)
evaporatorwick”)
baseisreached. 5. Place the filled removable water base including
thefloatassemblyontothebase. 6. Placetheupperpartonthebase.
Theunitisfilledwithwaterandcanbeswitched
on.
12timesa year
onceayear
Cleanthefan(seesection “Cleaningthefan”)
ReplaceIonicSilverStick® (seesection”Replacingthe IonicSilverStick®”)
1. G1 Rinseouttheremovablewaterbasewith lukewarmwater.
2. G2 For more thorough cleaning, clean the removable water base with a
commercial dish brush.
3. To decalcify the removable water base, use
EZCalAOS 7417 only (see section “Spare parts
andaccessories”).
Switching the unit on and off
Taking apart and emptying the unit
4. Drythepartsaftercleaning.
5. Insertthefloatassemblyintotheemptyremov-
If the unit is put into operation with an empty Theunitcaneasilybetakenapartforcleaning.
ablewaterbase.
removablewaterbaseoriftheremovablewater basegoesemptyduringoperation,theevapora-
WARNING
6. Put the unit together (see section “Putting the unittogether”).
tor wick dries out, no evaporation is generated
andanunpleasantodorcanresult.
Danger to life through electrical shock!
Donotunplugtheunitfromtheelectricalsocket
Theunitisfilledwithwater.
withwethands.
5
1. Plugthepowerplugintotheelectricalsocket.
Cleaning the fan
Putting the unit together
A. Wood, leather, carpet, curtains, and other types
offabricsoakupalotofmoisture,thusnotleav-
Unitistakenapartandemptiedfromwater.
Unitistakenapartandemptied.
ing enough moisture in the air. If the window is
left open, then this allows moisture to escape
Only use the manufacturer’s recommendet 1. Insertthefloatassemblyintotheremovablewa-
fromtheroom.Acommonreasonisthattheunit
cleaning agent EZCal (see chapter “Spare parts
terbase.
is placed next to a heating device in order to
andaccessories”).
2. B5 Placetheremovablewaterbaseincluding
distribute quickly the moisture around the room
the float assembly on the base handles into the
withthehotair.Unfortunately,thisconceptdoes
1. G3 Wipe off the fan with a slightly damp
base.
notworkbecausethehotaircomingoutofavent
clothorcleaningrag.
3. Placetheupperpartontothebase.
will soak up most of the moisture, and none of
2. Drythepartsaftercleaning.
4. B Ensurethattheunitisputtogethercor-
theairwithintheroomwillreceiveany.
3. Put the unit together (see section “Putting the
rectly.
unittogether”).
5. Ensure that there are no foreign objects in the Q. Should I leave my door open or closed when
unit.
the unit is running?
Replacing the evaporator wick
Theunitisputtogether.
A. Leaving the door open allows moisture to leave
the room and go into other areas of the house.
Theevaporatorwickshouldbereplacedinthecase
Ifyouwouldlikethemoisturetostaywithinone
of heavy pollution, calcification, unpleasant odor, Transporting the unit
specific room you should consider closing the
reduced air throughput, etc. Evaporator wicks are
doorwhiletheunitisrunning.
available from retailers, where the unit was pur-
CAUTION
chasedfrom.
Q. How much moisture do I need in my room?
Risk of injury by falling parts!
A. Suggested humidity level is between 4060%.
Unitistakenapartandemptiedfromwater. Only use the manufacturer’s original evaporator
Always handle the unit by the base when unpackingandlifting.
Q. What are the effects of too little or too much humidity?
wicks (see chapter “Spare parts and accesso-
A. Dryaircancausedryskin,staticelectricity,out
ries”).
CAUTION
of tune musical instruments, increased levels of dust (dry air causes dust to rise), damage to
CAUTION
Water damage due to water spilling over!
wooden objects (dry out and eventually cracks appear), discomfort, sickness, and dries out
Damage to the damp evaporator wicks due to
Emptytheunitbeforetransporting.
nasal membranes. Over-humidifying the air can
rinsing or wringing!
causemoldandpeelingofwallpaper.
Donotrinseorwringouttheevaporatorwick.
1. Empty the unit (see section “Taking apart and
emptyingtheunit”).
Q. Why do I need a humidifier when I can just
1. H1 Toopenthefloatassembly,turnthefloat 2. Drytheunit.
open my window?
tipcounter-clockwise(OPENarrow)andpullup. 3. Pick the unit up by the base and carry it to the A. Theamountofmoisturewithintheoutsideairis
2. H2 Pulltheusedevaporatorwickupandre-
desiredlocation.
nothighenoughtohumidifyaheatedroom.
movefromthefloatbasketanddiscard.
CAUTION
Storing the unit
Q. Where should I place my humidifier? A. The unit should be free-standing, on a flat sur-
Damage to the unit due to removal of the float body (styrofoam)!
1. Cleantheunit(seechapter”Servicingandcleaningtheunit”).
face and not close to a wall, window, door, or thermal bridge so that air can circulate around andunderneaththeunit.
Do not remove the float body (styrofoam) when 2. Drytheunitcompletely.
unpackingtheunit.
3. Packtheunit,preferablyintheoriginalpackag- Q. If my unit runs dry is that ok?
ing.
A. Ifthereisapossibilitythatyouwillbeunableto
3. H3 Installthenewevaporatorwickontothe 4. Storetheunitinadry,coolplace.
addwatertotheunitanditwillrundry,turnthe
floatbasket.
unitoffbeforeyouleave.Theunitwillnotbeable
4. H4 To close the float assembly, place the
to humidify the air if there is no water in it, and
float tip on the float basket and the evapo- Spare parts and accessories
youmaynoticeafoulodor.
rator wick, push down and turn clockwise
(CLOSEarrow).
Youcanpurchasesparepartsandaccessoriesfrom Q. Can this unit be used all year round?
5. Tocheck,gentlypullthefloattipupwards.Indo- specialized retailers and replace them on the unit A. Yes,theunitcanbeusedallyearround.Theunit
ingso,itshouldnotliftoffthefloatbasket.
yourself. Only original parts from the manufacturer
producesrelativehumiditywhichmeansthatthe
6. Ifnecessary,turnthefloattipagainandrecheck. canbeused.Repairscanonlybecarriedoutbypro-
airwillonlytakeasmuchmoistureasitcanhold.
Insertthefloatassemblyintotheemptyremov- fessionals.Thisalsoappliestoafaultypowercord.
Theunitwillnotover-humidifytheair.
ablewaterbase.
Please check with the retailer the humidifier was
7. Put the unit together (see section “Putting the purchasedfrom.
Q. Is it ok to put the removable water base in the
unittogether”). Replacing the Ionic Silver Stick®
Accessories Evaporatorwick IonicSilverStick®
Description 7018 7017
dishwasher? A. Do not place the removable water base in the
dishwasher.Theremovablewaterbasewillmelt.
Filltheremovablewaterbasewiththeprescribed
Unitistakenapartandemptiedfromwater.
EZCal(decalcification andcleaningagent)
7417
ratioofwateranEZCalasdescribedonthepackagingofEZCal.EZCalwillremovemineraldepos-
1. Remove the Ionic Silver Stick® from the bottom
itsfromtheremovablewaterbase.
oftheremovablewaterbaseanddiscardit.
2. PlacethenewIonicSilverStick®intheholderat Frequently asked questions
Q. Can I use distilled water?
thebottomoftheremovablewaterbase.
Q. Why isn’t there enough moisture in my A. Yes you can.The evaporator does not need the
3. Insertthefloatassemblyintotheemptyremov-
room?
mineralsinthetapwatertofunctionproperly.
ablewaterbase.
A. Howoftendoyouruntheunit?Iftheunitisonly
6
4. Put the unit together (see section “Putting the
run at night, then during the day the moisture
unittogether”).
levelwilldropifmoistureisnotconstantlyadded
totheair.
Q. What is EZCal? A. There is a sample packet of EZCal included in
the packaging of your humidifier. EZCal from AIR-O-SWISS is an easy and safe
cleaning and descaling agent recommended for all
humidifiers.Itremovesmineraldepositsfromthewater
base.Itisavailableatselectedretailstores.
CustomerServicePhoneNumber:1-800-336-0326
(USAandCanadaonly)
Air humidification general
information
Did you know that air that is too dry · dries out mucous membranes and
additionally
causeschappedlipsandstingingeyes? · promotesinfectionsandsicknessesoftherespi-
ratorypassages? · leadstoalackofenergy,exhaustionandconcen-
trationweakness? · burdenspetsandroomplants? · encourages dust development and
the electro-
static charge of synthetic textiles, carpets and syntheticflooring? · damages
wooden fixtures, especially hardwood floors? ·
putsmusicalinstrumentsoutoftune?
The physical comfort of human and animal is dependent on many influences. One
of those is correctlyhumidifiedair.Duringtheheatingperiod,the cold outside
area which streams into living spaces through the windows is warmed.This
results in a plummet in the relative air moisture. An adverse
climateforplantsandanimals,woodenobjectsand
furnituredryoutandpeoplefeeluncomfortableand are susceptible to colds in
higher numbers. As a rule,roomclimateiscomfortablewhentherelative
moistureisbetween40%and60%.Airhumidificationisespeciallywiseinthewinter.
Troubleshooting
Repairs on electric appliances can only be
carriedoutbyspecialists.Throughimproperrepairs, considerable danger for the
operator can result andvoidswarrantyclaims.
WARNING
Danger to life through electrical shock!
Donotcarryoutanyrepairsonelectricalparts.
Fault
Cause
Solution
Theunitisnotworking
Powerplugisnotplugged
in.
Pluginthepowerplugandswitchontheunit.
Removablewaterbaseis notinsertedwhenputting theunittogether.
Insert the removable water base (see section “Puttingtheunittogether”).
Grindingnoises
Waterbaseisnotinsertedcorrectly.
Inserttheremovablewaterbasecorrectly(see section”Puttingtheunittogether”).
Noairhumidification
Nowaterintheremovablewaterbase.
Fill the removable water base (see section “Fillingtheunit”).
Calcifiedevaporatorwick. Replace the evaporator wick (see section “Replacingtheevaporatorwick”).
Floattipwithfilllevelring Unitcomponentforgotten
notvisiblewhenfilling whenputtingtheunit Unplugthepowerplug.
together.
Check if the unit is put together correctly
(drawingB).
Unitputtogetherincorrectly.
Unitislosingwater
Unitcausesunpleasant odor
Unitwasoverfilled.
Emptythewater(seesection”Takingapartthe unit”).
Drytheunit.
Unitcomponentforgotten
whenputtingtheunit Unplugthepowerplug
together.
Check if the unit is put together correctly
Unitputtogetherincor-
(drawingB).
rectly.
Unitisnotfilledinopera-
tion.
Filltheunit(seeparagraph”Fillingtheunit”).
Evaporatorwickisdirty. Replace the evaporator wick (see section “Replacingtheevaporatorwick”).
7
Thank you for choosing an AIR-O-SWISS Evaporator! For further product
information, visit www.airoswiss.net or call
1-800-336-0326 (USA and Canada only).
Merci d’avoir choisi un évaporateur AIR-O-SWISS! Pour de plus amples
renseignements sur le produit, visitez www.airoswiss.net ou composez le
1-800-336-0326 (États-Unis et Canada
seulement).
¡Gracias por elegir el Evaporador AIR-O-SWISS! Para más informaciones sobre
este producto, visite www.airoswiss.net o llame al
1-800-336-0326 (Solamentepara Estados
Unidos y Canadá).
AIR-O-SWISS is a registered trademark of PLASTON AG, Switzerland PLASTON
International Corp., Naperville, IL, USA
Version: 1 Edition: 04/08
34614-00
References
- BONECO AG - humidifier, air washer, air purifiers and Air Shower fans - Boneco
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Air-o-swiss Air Cleaner Parts - Select From 3 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>