Specifications

  • Model: Air-O-Swiss AOSE2441
  • Operating Language: English
  • Power Cord Length: 4ft
  • Dimensions: 1ft

Product Information

The Air-O-Swiss AOSE2441 is a humidifier designed to improve air
quality by adding moisture to the air in living spaces. It features
a humidification system that helps maintain an optimal humidity
level for a comfortable environment.

Product Usage Instructions

About this document

The provided document includes safety instructions, technical
data, description of the unit, unpacking guidelines, operation
procedures, cleaning and servicing steps, transportation and
storage instructions, spare parts information, and FAQs.

Safety Instructions

Follow the warning levels provided in the manual to ensure safe
usage of the product. Pay attention to symbols indicating possible
dangers and necessary precautions to prevent injuries or material
damage.

Putting the unit into operation

Before operating the unit, make sure to read and understand all
safety instructions and warnings. Only use the unit for its
intended purpose of humidifying the air in living spaces. Do not
put foreign objects or substances into the unit.

Cleaning and Servicing

Regularly clean and service the unit as per the instructions in
the manual to ensure optimal performance and longevity. Avoid using
additives or substances not recommended by the manufacturer.

Transporting and Storing

When transporting the unit, handle it with care to prevent
damage. Store the unit in a safe place when not in use, following
guidelines provided in the manual.

FAQs

Q: Can I use fragrances or water conditioners with the

Air-O-Swiss AOSE2441?

A: The unit is not suitable for the use of additives like
fragrances or water conditioners. Avoid using any substances that
are not recommended by the manufacturer.

Q: What should I do if the unit overflows?

A: Check the float tip as it may be causing the overflow. Ensure
it is functioning correctly to prevent any issues with water
overflow.

Q: What are the warning levels in the manual?

A: The warning levels include WARNING for possible danger
resulting in death or serious injury, CAUTION for dangerous
situations leading to slight injury, and CAUTION for critical
situations causing material damage.

“`

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Air-O-Swiss AOSE2441 Owner’s Manual
Shop genuine replacement parts for Air-O-Swiss AOSE2441
Find Your Air-O-Swiss Air Cleaner Parts – Select From 3 Models ——– Manual continues below ——–

READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! ¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!

AOS E2441
Evaporator Évaporateur Evaporatore

Operating instructions English

3

Mode d’emploi Français

8

Instrucciones de Operación Español 13

A1

A2

A3

A

A4

A5

A6

A7

A8

A9

A10

A11

A12

A13

A14

4ft

1ft

B3

B B15

B16

B1

B2 B17

B3

B18

B19
B4 B7
B5
B6

B7

B13

B8

B9

B20

B21

B10

B11

B14

B12

B13 B14
B14

C1

C2

C3

C

C4

C5

C6

C7

D1

D2

D

D3
STOP!

E1

E2

E3

E

E4

STOP!

F1

F2

F3

F

F4

F5

F6

G1

G2

G3

G

H1

H2

H3

H

H4

H5

Operating instructions

Therearethefollowingwarninglevels:

· A2 Never pull the power plug out of the

English

Page Chapter

3

About this document

3

Safety instructions

4

Technical data

4

Description of the unit

4

Humidification system

4

Unpacking the unit

4

Putting the unit into operation

5

Switching the unit on and off

5

Cleaning and servicing the unit

6

Transporting the unit

6

Storing the unit

6

Spare parts and accessories

6

Frequently asked questions

7

Air humidification general

information

7

Troubleshooting

About this document
These operating instructions are a compo-

Warning level
WARNING
CAUTION CAUTION

Description
Possibledanger. Non-observancecould resultindeathorseriousinjury.
Dangeroussituation. Non-observancecould resultinslightinjury.
Criticalsituation. Non-observancecould resultinmaterial damage.

Inthisdocument,thefollowingsymbolsareusedto facilitatefastaccesstoinformation:

Symbol

1. 2.

Description Conditionwhichmustbemetbefore beginninganaction Actionwithoneormorestep(s) whoseorderisnotrelevant Actionwithseveralstepswhose orderisrelevant

electricalsocketbythecord. · A3 Neverpullthepowerplugoutoforplug
itintotheelectricalsocketwithwethands. · A4 OnlyplugtheunitintoanACsupply. · B14 Operatetheunitonlyatthevoltageac-
cordingtoratingplateontheunit. · Donotoperatetheunit:
– A5 ifcordorplugaredamaged. – followingamalfunction. – A6 ifithasfallendownorhasbeenother-
wisedamaged. · A7 Repairs and changes on electric appli-
ances and cables may only be carried out by specialists. · Unplugthepowerplugfromtheelectricalsocket inthefollowingcases: -beforeeachemptyingtheunit, – beforeeachcleaning, – beforeeachreplacementoftheevaporatorwick ortheIonicSilverStick®, – before installing/uninstalling individual components, -beforetakingofftheupperpart, -beforeeachmoveoftheunit. · A8 Neversubmergethelowerpartwiththe

nent of the product and describe its safe use.

Listingoffirstlevel

electricalpartandfaninwaterorotherliquidsor

The operating instructions apply exclusively to the ·

rinseitoffwithwaterorotherliquids.

productdescribedwithin.

Listingofsecondlevel

· Readthroughtheinstructionsthoroughlypriorto

Observe the following precautions to prevent inju-

puttingtheunitintooperation.

Resultofoneormoreactions

ry:

· Save the instructions for use throughout the

· A9 Placetheunitinsuchawaythatyoudo

lifespanoftheproduct.

(see…) Referencetoachapter,aparagraph

nottripoverthecord.

· Passtheinstructionsforuseontoeachsucces-

oradrawing

· Place the unit in such a way that it cannot be

siveowneroroperatoroftheproductandinclude any supplements received from the manufac-

Importantinformation

knockedover. · A10 Donotgetthecordstuckinthedooror

turer. Intended use

Referencetoanitemnumberin

A1

adrawinge.g.itemnumber1in

drawingA

clampitwithotherobjects. · Donotcoverthecord.
Observe the following precautions to prevent ma-

Theunitisonlyintendedtohumidifytheairinliving

terialdamage:

areasupto430sqft/120m³.Inareaslargerthan Safety instructions

· A11 Donotsitontheunitorplaceanyob-

430sq ft / 120m³, optimum air moisture for hu-

jectsonit.

mansandanimalsisnotguaranteed.Theunitmay Theunitisbuiltaccordingtothestate-of- the-artin · A12 Only place the unit on a flat, dry sur-

notbeusedforotherpurposes.Noforeignobjects technology and in accordance with the safety and

face.

maybeputintotheunit.

accidentpreventionregulations.Nevertheless,dan- · The unit’s air inlet and air outlet must be kept

gerscanresultfromitsusewhichcanleadtoinju-

clear.

Applicable standards

riestotheuserandothers,ortodamagetotheunit · Onlyusecleancontainersforfillingtheunit.

orotherpropertyiftheunitisnotusedaccordingto · Ensurethatthewateringcanhasnotbeenfilled

TheunitisETL-listed.Itcomplieswiththefollowing thesesafetyinstructions.

withfertilizerorsimilarsubstances.

standards:

· Priortousingtheappliance,readthroughthein- · Donotfilladditivesintotheunitortheremovable

· UL998

structions for complete use and retain in a safe

waterbase.

· CSAC22.2No.104-01

placeforlaterreference.

· Do not use water additives (e.g. essential oils,

· Thoseunfamiliarwiththeoperatinginstructions

fragrances, water conditioners).The material is

Forfurhterinformationcontact:

as well as children, and people under the influ-

notsuitablefortheuseofadditives.

www.intertek-sc.com

enceofmedicine,alcoholordrugsmaynotoper- · A13 Whentheunitisfilled,donotpushdown

atetheunit.

the float tip since this causes the unit to over-

Warnings and symbols in this document

· The unit may only be operated for its intended

flow.

useandwithinthespecifiedtechnicaldata.Unin- · Operatetheunitonlywhenfullyassembledand

In this document, warnings are used to prevent

tendedusecanbeadangertohealthorlife.

completelyoperational.

injuries and material damage. They are set up as · A1 Childrencannotrecognizethedangerin · Theappliancehasapolarizedplug(onebladeis

follows:

handling electric appliances. Therefore always

wider than the other). To reduce risk of shock,

WARNING LEVEL

supervisechildrenwhoareneartheunit. · Donotusetheunitinroomsinwhichthereare

this plug is intended to fit in a polarized outlet, onlyoneway.Iftheplugdoesnotfitfullyinthe

Cause and result of the danger

flammablegoods,gasesorvapors. · Do not alter the unit or put foreign objects into

outlet,reversetheplug.Ifitstilldoesnotfit,contact a qualified electrician. DO NOT attempt to

Precautionstopreventdanger

theunit.

undothissafetyfeature.

· A loose fit between the plug and the AC outlet

When using electricity, electrical shock poses a

(receptacle)maycauseoverheatingandadistor-

dangertolife.Observethefollowingprecautions:

tionoftheplug.Contactaqualifiedelectricianto

· Donotplacetheunitintherain.

replacelooseorwornreceptacles.

3

· Donotusetheunitindamprooms.

· Unplugthepowerplugwhennotinuse.

Technical data

Electricalvoltage Powerconsumption Humidityoutput
Suitableforrooms
DimensionsLxWxH Weight(empty) Operationnoiselevel

Value 100­120V/50­60Hz
24W
upto1.4gallons/24hrs upto220g/h
upto430sqft upto40m²
12.6″x12.6″x15.7″ 320x320x400mm
8.4lbs 3.8kg <25dB(A)

Description of the unit

Theunitconsistsofthefollowingcomponents:

· B1 Fillingopening

· B2 Topassembly

· B3 Floatassembly(B16­19)

· B4 IonicSilverStick®(ISS)

· B5 Removablewaterbase(B5­7)

· B6 Watercapacityfillline

· B7 Basehandles

· B8 Spout

· B9 LifecycleindicatorforIonicSilver

Stick®

· B10 Powercord/plug

· B11 Base(B11­14)

· B12 Fan

· B13 Slideswitch(B20­21)

· B14 Power rating plate (on the underside

oftheunit)

Thefloatassemblyconsistsofthefollowingparts: · B15 Floattip=Waterlevelindicator · B16 Waterlevelindicatorring · B17 EvaporatorwickAOS7018 · B18 Floatbasket · B19 Floatbody(styrofoam)

Theslideswitchconsistsofthefollowingparts: · B20 Slideswitch · B21 Operatinglight
Operating modes

The following operating modes can be set on the slideswitch:

Position 0 I

Function Theunitisswitchedoff Theunitisoperatinginnightmode (lownoiselevel) Theoperatinglightturnsgreen

II

Theunitisoperatinginnormalmode

(maximumhumidityoutput)

Theoperatinglightturnsgreen

Operating light
The green indicator light illuminates when the unit isswitchedon.Iftheremovablewaterbaseistaken offthebase,thegreenLEDchangestoredandunit operationisinterrupted,buttheunitisnotcurrentless. Only when the removable water base is returnedtothebase,theredLEDturngreenagainand theunitresumesoperation.
Power rating plate
B14 Among other things the following informationisdisplayedonthepowerratingplate: · Productname(Modelnumber) · Electricalvoltage · Powerconsumption · Signofconformity
Theinformationonthepowerratingplatedisplayedintheillustrationsisonlyanexample.Check the information displayed on the power rating plateofyourunit.
Humidification system
When filling the unit using the filling opening.The floattipclosesthefillingopeningassoonasthefill capacity is reached. The evaporator wick soaks up water.Thefanpushesthedryroomairthroughthe moist wick and emits it as a sufficiently moisturizedair.Throughthedirectedguidingoftheairflow, nearly constant humidification is possible at every water level. Therefore, the unit creates optimum air moisture, without additional control units being necessary.
Ionic Silver Stick® for water quality maintenance
B4 The specially adapted anti-microbial protection system Ionic Silver Stick® prevents microbialgrowthintheremovablewaterbase.Therefore, no chemical additives are necessary for the water qualitymaintenance. TheIonicSilverStick ®isself-renewing,servicefree andcanbeusedforayear.
Lifecycle indicator
B9 Theunitisequippedwithalifecycleindicator for the Ionic Silver Stick®. Please cross off the current month on the label and write the current yearonthelineprovided.
Unpacking the unit
Atdeliverytheunitiscompletelyassembledand alreadyequippedwithanevaporatorwick.
The float body is a component of the float assembly and does not belong to the packaging. Please do not dispose of the float body.This is notareplaceableaccessory.

CAUTION
Risk of injury by falling parts! Always handle the unit by the base when un-
packingandlifting.
CAUTION
Damage to the unit due to removal of the float body (styrofoam) inside the unit! C7 Donotremovethefloatbody(styrofoam)
whenunpackingtheunit.
1. Openthepackaging. 2. C1 Removetheupperpartofthestyrofoam
packaging. 3. C2 Reachintothefillingopeningandgrasp
theupperendoftheplasticbagsecurely. 4. C3 Carefullypulltheplasticbagwiththeunit
out of the packaging.When doing so, grasp the plasticbagsecurelyanddonotletgooftheplasticbagwhenremoving. 5. C5 Placetheplasticbagwiththeunitonthe floor and push the plastic bag down along the unit. 6. C6 Holdtheunitbythebaseandliftupoutof theplasticbag. A llpackagingcomponentsaswellastheplastic bagareremovedfromtheunit. 7. B14 Checkdataregardingthepowersupply onthepowerratingplate. 8. B Checkthatallcomponentsoftheunitare included.
Putting the unit into operation
Positioning the unit
CAUTION
Damage to the plastic due to high temperatures! Donotexposetheunittotemperatures>122°F/
50°C.
Observethefollowingprecautionswhenpositioning theunit: · A14 Remember to ensure easy accessibility
and sufficient room for servicing and cleaning theunit. · Onlyoperatetheunitwhenitisfilled!
1. Placetheunitonthefloororonaflat,drysurface intheroom.
2. Filltheunit(seesection”Fillingtheunit”).
Filling the unit
There are the following possibilities for filling the unitwithwater: · usingthefillingopeningontheupperpartor · directlyintotheremovedwaterbasefromafau-
cet.
Therearenoforeignobjectsintheunit. B Theunitisassembledproperly.

4

After an extended period of disuse, the unit shouldbeemptied.Ensurethattheunitistclean prior to resuming operation. Otherwise an unpleasantodorcanresult.
CAUTION
Damage and cracks in plastic caused by additives in the water! Do not put any additives (e.g. essential oils or
otherfragrances)intothewater. Ensurethattherearenowater-solubleadditives
(e.g.plantfertilizer)inacontainerbeforeusingit tofilltheunit.
CAUTION
Water damage due to overfilling! Whenfilling,donotexceedthemaximumfilling
capacityindicatedbythefillingline.
CAUTION
Water leaking from the unit! When the unit is filled, do not press down the
floattip.
Fillingtheunitatthefillingopening: 1. D1 Filltheunitusingacleancontainer(e.g.a
jarorawateringcan). 2. D2 Pour fresh, cold water into the filling
openingoftheupperpartwithacleancontainer. 3. D3 Stopfillingtheunitassoonasthewater
levelindicatorringofthefloatappearsinthetop assembly. Theunitisfilledwithwaterandcanbeswitched on.
Fillingtheunitattheremovablewaterbase: E1 The unit is switched off and the power
plug is unplugged (see chapter “Switching the unitonandoff”).

2. Set the slide switch to position I or position II accordingtoyourneeds(seesection”Operating modes”).
Theunitisswitchedon.
1. Settheslideswitchtoposition0.
WARNING
Danger to life through electrical shock! Donotunplugtheunitfromtheelectricalsocket
withwethands.
2. E1 Unplugthepowerplug. Theunitisswitchedoffandcurrentless.

Cleaning and servicing the unit

With increasing operating time, the air throughput and evaporator performance of the evaporator wickdecrease.Therefore,regularmaintenanceand cleaningoftheunitisarequirementforsmoothand trouble-freeoperation.
CAUTION
Damage to the plastic due to unsuitable cleaning agents!
Donotuseacidiccleaningagents.

Wipetheunitwithadampcloth.

Cleaning and servicing intervals

Recommended cleaning and service intervals dependonairandwaterqualityaswellasactualoperatingtime.

Interval onceaday
1weekor morewithout operation

Activity
Checkthewaterlevel, ifnecessary,refillwater(see chapter”Fillingtheunit”)
Emptyandcleantheunit(see section”Takingapartand emptyingtheunit”)

F1 The unit is switched off and the power plugisunplugged.
1. F3 Lifttheupperpartfromthebase. 2. F4 Remove the removable water base in-
cluding float assembly using the provided base handles. 3. F5 Emptytheresidualwaterfromtheremovablewaterbaseusingthespout. 4. F6 Removethefloatassemblyfromtheemptyremovablewaterbase.
WARNING
Danger to life through electrical shock! Do not empty water over the electrical part
(base).
5. Ifwaterisinthebase:emptythewateranddry thebase.
Theunitistakenapartandemptied.
Cleaning the removable water base
Unitistakenapartandemptiedfromwater.
Before cleaning the removable water base the floatassemblyhastoberemovedfromthewater base.
Only use the manufacturer´s recommended cleaning agent EZCal (see chaper “Spare parts andaccessories”).
WARNING
Danger to life through electrical shock! Unplugtheunitpriortocleaning. Neversubmergethebasewiththeelectricalpart
andthefaninwater.
CAUTION
Damage to the unit due to the use of the cleaning and decalcification agent EZCal on the running unit!

1. E2 Lifttheupperpartfromthebase. 2. E3 Lifttheremovablewaterbaseincluding
thefloatassemblybythebasehandles. 3. E4 Fillfresh,coldwaterdirectlyintothere-
movablewaterbase. 4. E4 Onlypourwaterinuntilthemaximumfill

every2weeks
every10­12 weeks(oras

Cleantheremovablewater basewithEZCalonly(seesection”Cleaningtheremovable waterbase”)
Replacetheevaporatorwick (seesection”Replacingthe

Before using EZCal, switch off and unplug the unit.
AftertheuseofEZCal,rinsethebasethoroughly withtapwater.
Before switching on the unit, ensure that there arenoresiduesofEZCalinthebase.

capacityontheinnersideoftheremovablewater needed)

evaporatorwick”)

baseisreached. 5. Place the filled removable water base including
thefloatassemblyontothebase. 6. Placetheupperpartonthebase. Theunitisfilledwithwaterandcanbeswitched
on.

1­2timesa year
onceayear

Cleanthefan(seesection “Cleaningthefan”)
ReplaceIonicSilverStick® (seesection”Replacingthe IonicSilverStick®”)

1. G1 Rinseouttheremovablewaterbasewith lukewarmwater.
2. G2 For more thorough cleaning, clean the removable water base with a commercial dish brush.
3. To decalcify the removable water base, use

EZCalAOS 7417 only (see section “Spare parts

andaccessories”).

Switching the unit on and off

Taking apart and emptying the unit

4. Drythepartsaftercleaning.

5. Insertthefloatassemblyintotheemptyremov-

If the unit is put into operation with an empty Theunitcaneasilybetakenapartforcleaning.

ablewaterbase.

removablewaterbaseoriftheremovablewater basegoesemptyduringoperation,theevapora-

WARNING

6. Put the unit together (see section “Putting the unittogether”).

tor wick dries out, no evaporation is generated

andanunpleasantodorcanresult.

Danger to life through electrical shock!

Donotunplugtheunitfromtheelectricalsocket

Theunitisfilledwithwater.

withwethands.

5

1. Plugthepowerplugintotheelectricalsocket.

Cleaning the fan

Putting the unit together

A. Wood, leather, carpet, curtains, and other types

offabricsoakupalotofmoisture,thusnotleav-

Unitistakenapartandemptiedfromwater.

Unitistakenapartandemptied.

ing enough moisture in the air. If the window is

left open, then this allows moisture to escape

Only use the manufacturer’s recommendet 1. Insertthefloatassemblyintotheremovablewa-

fromtheroom.Acommonreasonisthattheunit

cleaning agent EZCal (see chapter “Spare parts

terbase.

is placed next to a heating device in order to

andaccessories”).

2. B5 Placetheremovablewaterbaseincluding

distribute quickly the moisture around the room

the float assembly on the base handles into the

withthehotair.Unfortunately,thisconceptdoes

1. G3 Wipe off the fan with a slightly damp

base.

notworkbecausethehotaircomingoutofavent

clothorcleaningrag.

3. Placetheupperpartontothebase.

will soak up most of the moisture, and none of

2. Drythepartsaftercleaning.

4. B Ensurethattheunitisputtogethercor-

theairwithintheroomwillreceiveany.

3. Put the unit together (see section “Putting the

rectly.

unittogether”).

5. Ensure that there are no foreign objects in the Q. Should I leave my door open or closed when

unit.

the unit is running?

Replacing the evaporator wick

Theunitisputtogether.

A. Leaving the door open allows moisture to leave

the room and go into other areas of the house.

Theevaporatorwickshouldbereplacedinthecase

Ifyouwouldlikethemoisturetostaywithinone

of heavy pollution, calcification, unpleasant odor, Transporting the unit

specific room you should consider closing the

reduced air throughput, etc. Evaporator wicks are

doorwhiletheunitisrunning.

available from retailers, where the unit was pur-

CAUTION

chasedfrom.

Q. How much moisture do I need in my room?

Risk of injury by falling parts!

A. Suggested humidity level is between 40­60%.

Unitistakenapartandemptiedfromwater. Only use the manufacturer’s original evaporator

Always handle the unit by the base when unpackingandlifting.

Q. What are the effects of too little or too much humidity?

wicks (see chapter “Spare parts and accesso-

A. Dryaircancausedryskin,staticelectricity,out

ries”).

CAUTION

of tune musical instruments, increased levels of dust (dry air causes dust to rise), damage to

CAUTION

Water damage due to water spilling over!

wooden objects (dry out and eventually cracks appear), discomfort, sickness, and dries out

Damage to the damp evaporator wicks due to

Emptytheunitbeforetransporting.

nasal membranes. Over-humidifying the air can

rinsing or wringing!

causemoldandpeelingofwallpaper.

Donotrinseorwringouttheevaporatorwick.

1. Empty the unit (see section “Taking apart and

emptyingtheunit”).

Q. Why do I need a humidifier when I can just

1. H1 Toopenthefloatassembly,turnthefloat 2. Drytheunit.

open my window?

tipcounter-clockwise(OPENarrow)andpullup. 3. Pick the unit up by the base and carry it to the A. Theamountofmoisturewithintheoutsideairis

2. H2 Pulltheusedevaporatorwickupandre-

desiredlocation.

nothighenoughtohumidifyaheatedroom.

movefromthefloatbasketanddiscard.

CAUTION

Storing the unit

Q. Where should I place my humidifier? A. The unit should be free-standing, on a flat sur-

Damage to the unit due to removal of the float body (styrofoam)!

1. Cleantheunit(seechapter”Servicingandcleaningtheunit”).

face and not close to a wall, window, door, or thermal bridge so that air can circulate around andunderneaththeunit.

Do not remove the float body (styrofoam) when 2. Drytheunitcompletely.

unpackingtheunit.

3. Packtheunit,preferablyintheoriginalpackag- Q. If my unit runs dry is that ok?

ing.

A. Ifthereisapossibilitythatyouwillbeunableto

3. H3 Installthenewevaporatorwickontothe 4. Storetheunitinadry,coolplace.

addwatertotheunitanditwillrundry,turnthe

floatbasket.

unitoffbeforeyouleave.Theunitwillnotbeable

4. H4 To close the float assembly, place the

to humidify the air if there is no water in it, and

float tip on the float basket and the evapo- Spare parts and accessories

youmaynoticeafoulodor.

rator wick, push down and turn clockwise

(CLOSEarrow).

Youcanpurchasesparepartsandaccessoriesfrom Q. Can this unit be used all year round?

5. Tocheck,gentlypullthefloattipupwards.Indo- specialized retailers and replace them on the unit A. Yes,theunitcanbeusedallyearround.Theunit

ingso,itshouldnotliftoffthefloatbasket.

yourself. Only original parts from the manufacturer

producesrelativehumiditywhichmeansthatthe

6. Ifnecessary,turnthefloattipagainandrecheck. canbeused.Repairscanonlybecarriedoutbypro-

airwillonlytakeasmuchmoistureasitcanhold.

Insertthefloatassemblyintotheemptyremov- fessionals.Thisalsoappliestoafaultypowercord.

Theunitwillnotover-humidifytheair.

ablewaterbase.

Please check with the retailer the humidifier was

7. Put the unit together (see section “Putting the purchasedfrom.

Q. Is it ok to put the removable water base in the

unittogether”). Replacing the Ionic Silver Stick®

Accessories Evaporatorwick IonicSilverStick®

Description 7018 7017

dishwasher? A. Do not place the removable water base in the
dishwasher.Theremovablewaterbasewillmelt. Filltheremovablewaterbasewiththeprescribed

Unitistakenapartandemptiedfromwater.

EZCal(decalcification andcleaningagent)

7417

ratioofwateranEZCalasdescribedonthepackagingofEZCal.EZCalwillremovemineraldepos-

1. Remove the Ionic Silver Stick® from the bottom

itsfromtheremovablewaterbase.

oftheremovablewaterbaseanddiscardit.
2. PlacethenewIonicSilverStick®intheholderat Frequently asked questions

Q. Can I use distilled water?

thebottomoftheremovablewaterbase.

Q. Why isn’t there enough moisture in my A. Yes you can.The evaporator does not need the

3. Insertthefloatassemblyintotheemptyremov-

room?

mineralsinthetapwatertofunctionproperly.

ablewaterbase.

A. Howoftendoyouruntheunit?Iftheunitisonly

6

4. Put the unit together (see section “Putting the

run at night, then during the day the moisture

unittogether”).

levelwilldropifmoistureisnotconstantlyadded

totheair.

Q. What is EZCal? A. There is a sample packet of EZCal included in
the packaging of your humidifier. EZCal from AIR-O-SWISS is an easy and safe cleaning and descaling agent recommended for all humidifiers.Itremovesmineraldepositsfromthewater base.Itisavailableatselectedretailstores.
CustomerServicePhoneNumber:1-800-336-0326 (USAandCanadaonly)
Air humidification general
information
Did you know that air that is too dry · dries out mucous membranes and additionally
causeschappedlipsandstingingeyes? · promotesinfectionsandsicknessesoftherespi-
ratorypassages? · leadstoalackofenergy,exhaustionandconcen-
trationweakness? · burdenspetsandroomplants? · encourages dust development and the electro-
static charge of synthetic textiles, carpets and syntheticflooring? · damages wooden fixtures, especially hardwood floors? · putsmusicalinstrumentsoutoftune?
The physical comfort of human and animal is dependent on many influences. One of those is correctlyhumidifiedair.Duringtheheatingperiod,the cold outside area which streams into living spaces through the windows is warmed.This results in a plummet in the relative air moisture. An adverse climateforplantsandanimals,woodenobjectsand furnituredryoutandpeoplefeeluncomfortableand are susceptible to colds in higher numbers. As a rule,roomclimateiscomfortablewhentherelative moistureisbetween40%and60%.Airhumidificationisespeciallywiseinthewinter.

Troubleshooting
Repairs on electric appliances can only be carriedoutbyspecialists.Throughimproperrepairs, considerable danger for the operator can result andvoidswarrantyclaims.
WARNING
Danger to life through electrical shock! Donotcarryoutanyrepairsonelectricalparts.

Fault

Cause

Solution

Theunitisnotworking

Powerplugisnotplugged

in.

Pluginthepowerplugandswitchontheunit.

Removablewaterbaseis notinsertedwhenputting theunittogether.

Insert the removable water base (see section “Puttingtheunittogether”).

Grindingnoises

Waterbaseisnotinsertedcorrectly.

Inserttheremovablewaterbasecorrectly(see section”Puttingtheunittogether”).

Noairhumidification

Nowaterintheremovablewaterbase.

Fill the removable water base (see section “Fillingtheunit”).

Calcifiedevaporatorwick. Replace the evaporator wick (see section “Replacingtheevaporatorwick”).

Floattipwithfilllevelring Unitcomponentforgotten

notvisiblewhenfilling whenputtingtheunit Unplugthepowerplug.

together.

Check if the unit is put together correctly

(drawingB).

Unitputtogetherincorrectly.

Unitislosingwater
Unitcausesunpleasant odor

Unitwasoverfilled.

Emptythewater(seesection”Takingapartthe unit”).
Drytheunit.

Unitcomponentforgotten

whenputtingtheunit Unplugthepowerplug

together.

Check if the unit is put together correctly

Unitputtogetherincor-

(drawingB).

rectly.

Unitisnotfilledinopera-

tion.

Filltheunit(seeparagraph”Fillingtheunit”).

Evaporatorwickisdirty. Replace the evaporator wick (see section “Replacingtheevaporatorwick”).

7

Thank you for choosing an AIR-O-SWISS Evaporator! For further product information, visit www.airoswiss.net or call 1-800-336-0326 (USA and Canada only).
Merci d’avoir choisi un évaporateur AIR-O-SWISS! Pour de plus amples renseignements sur le produit, visitez www.airoswiss.net ou composez le
1-800-336-0326 (États-Unis et Canada seulement).
¡Gracias por elegir el Evaporador AIR-O-SWISS! Para más informaciones sobre este producto, visite www.airoswiss.net o llame al
1-800-336-0326 (Solamentepara Estados Unidos y Canadá).

AIR-O-SWISS is a registered trademark of PLASTON AG, Switzerland PLASTON International Corp., Naperville, IL, USA
Version: 1 Edition: 04/08
34614-00

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals