Air-O-Swiss Humidifier AOS U600 Ultrasonic User Manual
Important safety instructions
- Prior to using the appliance, read through the instructions for complete use and retain in a safe place for later reference.
- WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury.
- Connect the unit only to alternating current with voltage according to the rating label.
- Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1).
- Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way.
- Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user.
- Place the humidifier on a dry, level surface (5).
- Do not place the appliance directly on the floor or next to a heating vent (6).
- If the mist comes in contact with the floor prior to evaporating, the floor surface can become damaged. We do not accept any liability for damages in the case of incorrect placement of the unit.
- The unit should be placed in an elevated position (7), e. g. on a table, chest of drawers, etc.
- Place appliance where it is not easily knocked over (8).
- Always unplug when not in use.
- Only operate the humidifier when it is completely assembled.
- ALWAYS unplug before removing/filling/emptying the water tank, before cleaning/maintaining, assembling/dismantling of individual parts and before moving the appliance.
- Do not touch the water in the base during operation because of high frequency vibrations in the water.
- Do not run power cords under carpets, and do not cover with throw rugs. Arrange cord so that it will not be tripped over.
- Never pull the plug from the outlet by the cable or with wet hands.
- Do not use the appliance where combustible gases or vapors are present.
- Do not expose the appliance to rain, or use near water, in a bathroom, laundry area or other damp location.
- This unit must be used in its upright position.
- Do not allow foreign objects to enter ventilation or ex haust opening as this may cause electric shock or damage to the appliance. Do not block air outlets or intakes.
- Do not pour water into the mist outlet of the appliance.
- This appliance has a polarized plug (one blade is wider than the other). To reduce risk of shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
- A loose fit between the plug (receptacle) and the AC outlet may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
- Do not sit, stand or place any heavy objects on the appliance.
- Do not submerge the main body in water or other liquids.
- Disconnect power supply before servicing.
- Persons who are not familiar with the instructions for use, as well as children and persons under the influence of medication, alcohol, or drugs are not permitted to operate the appliance, or are only permitted to operate it under supervision.
- The use of water additives, such as ethereal/essential oils, fragrances, eucalyptus, water conditioners etc., damages the tank material and as a consequence the whole unit. Any use of such additives will void the manufacturer’s warranty.
- Remark: Neither humans nor animals can hear the high frequency vibrations.
Foreword
Congratulations on choosing the Ultrasonic Humidifier AOS U600 / U650 from AIROSWISS!
Did you know that dry room air:
- Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging eyes?
- Encourages infections and illnesses of respiratory system?
- Causes weariness, tiredness and poor concentration?
- Stresses household pets and house plants?
- Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers, carpets and plastic flooring?
- Damages furnishings made of wood and parquet?
- Detunes musical instruments?
General information
A comfortable atmosphere indoors is reached with a relative humidity level between 40 and 60%. Your humidifier automatically controls the humidity level according to the desired setting. If the air is too dry, the humidifier will automatically switch on. As soon as the desired humidity level is reached, it will switch off.
Unpacking
- Carefully remove the humidifier from the box. Place your hands underneath the product to pull it out of the box (10).
- Warning: Do not take the unit out of the box by pulling up on the tank handle base may fall and will be damaged (11).
- Remove the plastic bag from the humidifier.
- Observe the information given on the rating plate about the voltage.
- Use the original packaging for storing the appliance if you do not use the humidifier all year round.
Description of the appliance
Setting up
Finding the ideal location for your unit:
- Do not place the humidifier directly next to a heating vent or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Safety Instructions).
- The unit should be placed in an elevated position (7), e. g. on a table, chest, etc. at least 3 ft off the floor.
- The mist outlet must not be pointed directly at plants, furniture, or other objects (12). Keep distance of at least 20 inches (50cm).
- Soak the demineralization cartridge in a water bath 24 hours before using it (13). The granules have to absorb water to reach high performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
- On average the demineralization cartridge should be replaced every 2 – 3 months depending on your water hardness. Some areas may need to replace the cartridge sooner, some may last longer.
- The cartridge must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.
- See «Replacement of the demineralization cartridge».
- Read the instructions under «Filling the Tank» for adding water in the humidifier (14 and 15).
- Place the water tank onto the base.
- Insert the plug into the socket and switch on the appliance using the on/off dial (18 and 19).
- About 10 to 15 minutes after it is switched on the device will reach its full output level.
- Make sure that the cable is not pinched anywhere (9). Do not operate the humidifier if the cable is damaged (2).
Filling the tank
Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The empty indicator light comes on showing tank is empty.
- Remove the water tank from the base and unscrew the water tank cap (14).
- Make sure that no foreign objects are in the water tank.
- Fill the tank with clean, cold water from the tap (15). Close the cap of the water tank securely, place the water tank onto the base (16). The water is now running from the tank into the base.
- Do not pour water into the mist outlet of the appliance (17).
- Insert the plug into the socket (18) and switch on the appliance using the on/off dial (19). The empty indi cator light may stay illuminated for some seconds until the base is filled with water.
Do not use additives
Water additives (ethereal/essential oils, fragrances, eucalyptus, water
conditioners, etc.) must not be used! Even a small amount can cause cracks in
the material. The material isn’t made for the use of such additives. One drop
is enough to damage the tank and as a consequence the unit. Any use of such
additives will void the manufacturer’s warranty.
Operation AOS U600
-
On/Off Dial and regulation of mist output
Turning the righthand rotary dial clockwise switches the appliance on and at the same time regulates the mist output from low to high. -
Hygrostat (setting the humidity level)
The desired humidity level can be set by turning the lefthand rotary dial clockwise. A relative humidity of between 40% and 60% is recommended. You can achieve this level by rotating the dial until it is roughly in the vertical position. The measurement accuracy is +/ 5%. As soon as the humidity exceeds the desired setting, the appliance switches off. The appliance does not switch off if the dial is turned all the way to the right. This activates the continuous operation function. -
Operation with pre-heating (warm mist)
Button C is used for switching the preheating on and off (symbol D lights up). As a result, the water is preheated to a temperature of 176 °F (80 °C) before entering the nebulizer space. It takes approx. 10 to 15 minutes for the water in the base to warm up. The mist now leaves the humidifier at a pleasant temperature of 104 °F (40 °C). The advantage of this is that the room temperature does not drop and, in addition, it significantly improves the water quality maintenance. -
Pre-heating indicator (On/Off)
-
Empty indicator (red)
The water level is easy to see, thanks to the transparent water tank. The appliance also alerts you when the water tank is empty. The red empty indicator is illuminated (symbol C). Please read the chapter «Filling the tank» for more information. The red symbol C may stay illuminated for some seconds with a refilled tank until the base is filled with water. -
On/Off Dial and Display Dimmer
By pressing button A once, you can switch the unit on. By pressing it twice, the dimmer is switched on which auto matically dims the display brightness and symbol N comes on. When changing any settings the display will illuminate for a few seconds before returning to dimmer mode. By pressing button A a third time, the unit is switched off. This button is also used to reset the cleaning indicator light (by holding down). -
Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity level from 30% to 80% or CO (continuous operation). A relative humidity between 40 and 60% is recommended. The accuracy of measurement is +/ 5%. The unit will switch off when the moisture level exceeds the desired setting. During selection the target value is displayed (symbol DESIRED). The display will automatically show the current value after a few seconds (symbol CURRENT). -
Timer
Using button C, the operation time can be set adjustable between 1 and 8 hours or CO (continuous operation). Symbol G shows the operating period that has been set (1h/2h/3h/4h/5h/6h/7h/8h/CO). The display will automatically show the current humidity after a few seconds. -
Mist output (regulating mist output)
By repeatedly pressing button D you can control the mist output. Symbol H shows which of the three levels (low/medium/high) you have selected. -
Operation with pre-heating (warm mist)
Button E is used for switching the preheating on and off (symbol I lights up). As a result, the water is preheated to a temperature of 176 °F (80 °C) before entering the nebulizer space. It takes approx. 10 to 15 minutes for the water in the base to warm up. The mist now leaves the humidifier at a pleasant temperature of 104 °F (40 °C). The advantage of this is that the room temperature does not drop and, in addition, it significantly improves the water quality maintenance. -
Automatic mode and Sleep mode
The automatic and sleep modes can be activated by pressing button F. By pressing the button once, the automatic function is switched on (symbol J appears on the display), maintaining the optimum humidity subject to the temperature. Control takes place by means of output quantity and preset target value. By pressing the button twice, the sleep function is switched on (symbol K appears on the display), the target humidity is 50 – 65%; the operation time is set at 6 hours; the heating is switched on and the display brightness is automatically dimmed. In addition, the output quantity is also controlled subject to the difference between the target value and the actual value. The hygrostat and mist output settings cannot be changed in either mode. If the buttons B or D are pressed, the unit will no longer be in auto or sleep mode. -
Timer Indicator
-
Mist Output Indicator
-
Pre-heating Indicator
-
Automatic Mode Indicator
-
Sleep Mode Indicator
-
Empty indicator
The water level is easy to see, thanks to the transparent water tank. The appliance also alerts you when the water tank is empty. The empty indicator is illuminated (symbol L). Please read the chapter «Filling the tank» for more information. The symbol L may stay illuminated for some seconds with a refilled tank until the base is filled with water. -
Cleaning indicator
If symbol M «CLEAN» appears on the display, the appliance should be cleaned as recommended by the manufacturer. This symbol comes on automatically every 2 weeks, depending on the level of use. The display can be reset by holding down button A until the light disappears. -
Dimmer Indicator
Display Dimmer Off Display Dimmer On For instructions see button A
Cleaning/Maintenance
Always unplug the unit before removing the water tank. Do not touch the water in the base during operation!
Caution – risk of electric shock and damage of the product!
- Switch off the appliance (20) and unplug it from the socket before cleaning it (21).
- Clean the water tank and the base regularly. Use water only, no detergents (22).
- Use AIROSWISS EZCal custom cleaning and descaling agent only to remove deposits from the membrane regularly (23). There is a sample of EZCal included in the packaging of your humidifier. Instructions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal. This can cause damage to the product and voids the warranty. Thoroughly rinse the base with potable water after using EZCal and make sure no EZCal residues remain in the base. EZCal from AIROSWISS is the only recommen ded cleaning and descaling solution. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal will void the warranty.
- Make sure main body is never submerged in water (24)!
- The cleaning indicator still appears on the display after cleaning. To reset it hold down the ON/OFF button until the clean light disappears.
- Clean the inner parts with a soft cloth. Do not use any solvents or aggressive cleaning agents to clean the appliance (25).
- Only use the brush to clean the membrane. This should be done once a week. Only use the softbristle portion of the brush (26).
- Change the water in the tank at least once a week if water is standing for more than a week.
- To remove the mist outlet (27): Twist the tabs on the mist outlet to either the right or the left. Align the tabs and arrow on the mist outlet with the arrows on the ring around the mist outlet. Pull up on the mist outlet once the arrows are aligned.
Water quality maintenance
The Ionic Silver Stick (ISS) uses the antimicrobial effect of silver to
prevent the growth of microbes in the water base. It begins to function as
soon as it comes into contact with water, even if the unit is switched off.
The Ionic Silver Stick should be changed every year. Look at picture 28 for
the position of the ISS in the base part of the unit. Do not touch the water
in the base during operation! Switch off the unit first. Contact your local
retailer or check our website www.airoswiss.net
for reorder information. The Ionic Silver Stick® comes with a metallic clip
which can be removed for the placement in this product type.
Lifecycle Indicator
Your appliance comes with a lifecycle indicator for changing the Ionic Silver
Stick®. To remind yourself of when you put the ISS into operation, please
cross the current month on the stamp and write the current year on the line
provided (29).
Replacement of the demineralization cartridge
Always unplug the unit before removing the water tank. Do not touch the
water in the base during operation!
The water tank is equipped with a demineralization cartridge. This cartridge has to be replaced every 2 – 3 months. If the water is very hard, it may be necessary to replace the cartridge earlier. White dust around the device is a sure sign that the cartridge needs replacing. If white residue still forms around the device after a new cartridge has been inserted, please make sure that the water you are using is untreated. If the water flows through a decalcification system – such as an ion exchanger – (sodium is added to remove calcium) in the building before it is used in the humidifier, salt can pre cipitate as white dust around the device. The demineralization cartridge or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore. Option A: replace the granules
- Remove the water tank from the base and unscrew the water tank cap (30).
- The demineralization cartridge is attached to the tank cap. Unscrew the cartridge from the cap by turning it counterclockwise (31). Important: do NOT dispose of the water tank cap!
- Open the cartridge (32).
- Throw the content into the waste (Attention! Disposed granules can make the floor slippery!) (33).
- Place the enclosed pink styrofoam piece in the center of the cartridge. Do not push it to the bottom as it will be difficult to remove afterwards (34).
- Pour the contents of one refill granules bag into the plastic cup that is included with the refill granules packaging (35).
- Place the empty cartridge with the plug in the center onto the plastic cup (36).
- Turn the plastic cup and cartridge over and shake until all granules are in the cartridge (37).
- Remove the plastic cup and the pink styrofoam piece from the cartridge (38) and retain for future use (the refill granules consists of 3 refill bags) (39).
- Close the cartridge (40).
- Soak the demineralization cartridge in a water bath 24 hours before using it (43). The granules have to absorb water to reach high performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
- Screw the cartridge on the water tank cap (44).
- Screw the cartridge on the bottom side of the water tank, put the tank on the main body (45)
Placing granules in the center of the cartridge allows them to escape in the unit or to clog the unit. The unit will no longer operate properly and the granules need to be cleaned out thoroughly.
Option B: replace the whole cartridge
- Remove the water tank from the base and unscrew the water tank cap (30).
- The demineralization cartridge is attached to the tank cap. Unscrew the cartridge from the cap by turning it counterclockwise (31). Important: do NOT dispose of the water tank cap!
- Throw the whole cartridge into the waste (41).
- Unpack the new cartridge (42).
- Soak the demineralization cartridge in a water bath 24 hours before using it (43). The granules have to absorb water to reach high performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
- Screw the cartridge on the water tank cap (44). Close tank cap well and place the tank on the main body (45).
Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry thoroughly.
Preferably store the appliance in its original box, in a dry place away from
high temperatures.
Legal notice
The humidifier is cULlisted. Subject to technical change. The instructions
for use are protected by copyright © PLASTON AG.
Accessories
Contact your local retailer or check our website www.airoswiss.net for reorder information.
Customer Service
Customer Service
(USA) 18003360326
www.airoswiss.net
Troubleshooting
Technical data
when used with preheating to 176 °F (80 °C)
General Humidifier Questions
Q. Why isn’t there enough moisture in my room?
A. How often do you run the unit? If the unit is only run at night, then
during the day the moisture level will drop if moisture is not constantly
added to the air.
Q. Do you leave your door open or closed when the unit is running?
- A. By leaving the door open, this allows moisture to leave the room and go into other areas of the house. If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running.
- A. b) Wood, leather, carpet, curtains, and other types of fabric soak up a lot of moisture, thus not leaving enough moisture for the air. If the window is left open, then this allows moisture to escape the room. Another factor is a lot of times the unit is placed next to a heating device. The idea is that the air blowing into the room will quickly place moisture around the room. Unfortunately, this concept does not work because the hot air coming out of a vent will soak up most of the moisture, and none of the air within the room will receive any.
Q. How much moisture do I need in my room?
A. Suggested humidity levels are between 40 – 60%.
Q. What are the effects of too little or too much humidity?
A. Dry air can cause dry skin, static electricity, out of tune musical
instruments, increased levels of dust (dry air causes dust to rise), damage to
wooden objects (dry out and eventually cracks appear), discomfort, sickness,
and dries out nasal membranes. Over humidifying the air can cause mold and
wallpaper to peel.
Q. Why do I need a humidifier when I can just open my window?
A. The moisture level within the outside air is not high enough to humidify a
room. The colder the air the less moisture it is capable to hold, and the more
the air is heated up the percentage of relative humidity is lower. Relative
humidity means the amount of water vapor in the air, compared to the amount
the air could hold if it was totally saturated. The difference is higher
between outside and inside temperatures; more humidification is needed because
of the dry air in the room.
Q. Where should I place my humidifier?
A. The unit should be freestanding and not close to a wall, window, door, or
thermal bridge so that air may circulate around the unit.
Ultrasonic Frequent Questions
Q. Why does it say open/close on the demineralization cartridge cap?
A. Those directions are there in case you decide to use the refill option to
replace the granules; the purpose is for how to open and close the cap. If you
did open the cap before placing it in the water tank, you will most likely
notice that there are granules in the water tank and the base of the unit.
Immediately turn off the unit, and empty the water out of the base and the
water tank. Begin removing all granules from base and water tank. Use brush to
clean around membrane.
Caution: Do not dispose of granules in sink! Used granules must go in
waste!
Q. I just replaced my cartridge, and the contents and water in the base has
turned a blue-green color.
A. This sometimes occurs when the cartridge, or even the granules, are
replaced. This does not occur with all replacement cartridges or granules, and
is a reaction of water content and the Ultrasonic vibrations. This is not an
indicator to replace the cartridge.
Q. There is no fill-line on the water tank, how far may I fill it up?
A. There is no fill line on the water tank, and it may be filled all the way
to the top.
Q. What is the purpose of the demineralization cart- ridge (DMC)?
A. The DMC removes minerals from the water to prevent white dust. The contents
of the cartridge need to be soaked for 24 hrs prior to first using the unit
so that they may fully expand and remove minerals from the water. The contents
of the DMC have a life of 2 – 3 months. The cartridge may need to be replaced
more often depending on water hardness and how often the unit is used. An
indication of when the DMC needs to be changed can be white dust or reduced
amount of mist output.white dust. The contents of the cartridge need to be
soaked for 24 hrs prior to first using the unit so that they may fully expand
and remove minerals from the water. The contents of the DMC have a life of 2 –
3 months. The cartridge may need to be replaced more often depending on water
hardness and how often the unit is used. An indication of when the DMC needs
to be changed can be white dust or reduced amount of mist output.
Q. Is it ok to use distilled water with the unit?
A. For best results with your ultrasonic humidifier use distilled or
reverseosmosis water and remove the demineralization cartridge.
Q. I just replaced the contents of the cartridge and now have granules
everywhere.
A. First, make sure there are no granules in the middle of the cartridge.
Placing granules in the middle of the DMC allows them to escape in the unit.
Immediately turn off the unit, and empty the water out of the base and the
water tank. Begin removing all granules from base and water tank. Use brush to
clean around membrane.
Caution: Do not dispose of granules in sink! Used granules must go in
waste!
Q. The directions tell me not to place the unit directly on the floor, why
do I have to elevate the unit?
A. The idea with this unit is to allow one to force humidity into the air.
Because of this, the carpeting or wood floor surrounding the unit may become
damp. If the unit is placed at least 3 feet off the floor, the mist will have
the opportunity to evaporate before hitting the floor.
Q. Water does not go into the tank.
A. In order to fill the tank, it must be turned upside down. The cartridge is
placed on the water tank cap. Do not pour water in the tube which is the mist
outlet.
Q. White dust is emitted from the unit
A. White dust particles are minerals that are broken up in tiny pieces by the
ultrasonic process.
Solve the problem:
- Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours. If the cartridge is soaked in the water tank, the water in the tank and the base needs to be replaced before using the unit.
- Exchange the demineralization cartridge after 12 months when you use very hard water (for softer water after 23 months). No matter how hard your water is, exchange the cartridge at the very latest after 6 months.
- Don’t use water from a preinstalled water softener, or sodium instead of calcium will be emitted from the unit. Use distilled water instead and remove the demineralization cartridge.
- For very hard water areas use only distilled water and remove the demineralization cartridge.
- Use ReverseOsmosis water (RO water) instead of distilled water and remove the demineralization cartridge.
- Cleaning light is illuminated (digital models) Switch off the unit and unplug it. Empty the water in the base. Rinse the base with hot/clean water. Do not submerge the base! Visually inspect the base for dirt or mineral build up. If soft water is used decalcifying the unit every 4 weeks with EZ Cal is suggested. If hard water is used the unit should be decalcified every 2 weeks. Do not forget to reset the clean light after resetting the unit.
Q. Reset cleaning light (digital models)
A. The cleaning light does not automatically reset. Hold down the power button
(button A in instruction manual) until the light stops flashing. The light
automatically comes on approx. after 14 days of plugging in the unit.
Q. The hygrometer on unit reads a different humidity level than external
hygrometer.
A. Not all hygrometers are calibrated the same, and most are off by +/ 5%.
Plus the humidity level is not the same in the whole room. The air circulation
is different in every corner of the room. The unit should not be placed near a
heating vent or a radiator as the heat will absorb all of the moisture.
Q. Humidity level is not changing or does not reach the desired humidity
level.
A. If the water tank needs refilling more than once per day, the unit is
working properly and the climatic condition in the room has an influence on
the humidity. Reasons for low humidity level:
- air circulation is very high (air is fully exchanged several times per day – the humidifier needs to starts its work from scratch)
- insulation of home (see air circulation)
- open space with high ceilings (not only the footage of the room counts but also the height) – highrise buildings require more humidification.
- open windows – works similar to air circulation (if it is very cold outside don’t open the window more than 2 times per day for 3 minutes)
- big difference between outside temperature and inside temperature – the colder the air the less moisture it is capable to hold and the more the air is heated up the lower is the percentage of relative humidity (=the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated)
- position of the unit if it is placed close to a door, window or air vent. This increases the air circulation.
Q. Tank is leaking
A. Check if there are any hairline cracks. Dropped units orwater tanks that
are cracked will not be covered under the warranty. Please contact the
retailer the unit was purchased from in case your unit arrives damaged.
Q. Placing the face in the mist
A. It is not recommended that anybody places their face in the mist. It is an
electrical product and should not be played with.
Q. No mist / unit is not working / empty indicator keeps flashing?
A. Fill up the water tank. Check if water is flowing through the
demineralization cartridge (attached to the water tank cap). If the water tank
is full but there is only little water in the base it indicates that the water
is now flowing through the demineralization cartridge.
- Wait for 15 minutes to allow the mist to come out of the unit.
- If the unit is not working and the empty light is not flashing you might have set the desired humidity too low and the current humidity level in the room is higher. That is why the unit switches off automatically.
- If the empty indicator keeps flashing and the tank is full, the water is not flowing through the cartridge. Exchange the cartridge or the granules in the cartridge after 23 months, in areas with hard water exchange the cartridge after 1 2 months. However, the demineralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore
- If the granules are new, see the following instructions:
- Make sure the cartridge and/or granules were soaked for 24 hours, dry granules take even longer for water to filter through the cartridge and into the base. Next, please remove 2 tablespoons of granules from the cartridge, and throw them away. When there are too many granules in the cartridge it does not allow water to flow from the tank to the base.
Q. Water tank cap is too tight to unscrew
A. This could be a cause of the air pressure within the water tank. Depress
the spring on the bottom of the water tank cap to release air from the water
tank. Continue to do this until you are able to unscrew the water tank cap.
Q. Unit is running intermittently.
A. How long has it been since the contents of the cartridge were replaced? If
23 months have passed, it is time to replace the contents of the cartridge.
However the demineralization cartridge and or the granules must be exchanged
at the latest after 6 months or the unit does not reach its full performance
anymore.
- If the contents of the cartridge were just replaced there are probably too many granules in the cartridge. Remove 2 tablespoons of granules from the cartridge.
Accessories
Q. Do I need to keep any parts before I replace the demineralization
cartridge?
A. Yes, always keep the water tank cap (this is the piecethat attaches the
demineralization cartridge to the water tank).
Q. What is the Ionic Silver Stick (ISS) and how long is it good for?
A. The Ionic Silver Stick (ISS) uses the antimicrobial effect of silver to
prevent the growth of microbes in the water base. It begins to function as
soon as it comes into contact with water, even if the unit is switched off.
The Ionic Silver Stick should be changed every year.
Q. Placement of the Ionic Silver Stick?
A. Please see picture 28 for instructions.
Q. Replacement reminder?
A. In each ISS box and on all the new products there is when starting to use
the ISS and write the year on the line indicated. Exchange it after one
year.when starting to use the ISS and write the year on the line indicated.
Exchange it after one year.
Q. What is EZ Cal?
A. There is a sample packet of EZCal included in the packaging of your
humidifier. EZCal is used for cleaning and descaling any of the AIROSWISS
humidifiers and cleans mineral buildup. EZCal is the only recommen ded
cleaning and descaling solution. Do NOT use any other cleaning solutions since
it can damage the product. Any use of cleaning solutions apart from EZCal
will void the warranty. Instructions for using are on the packet. Only use 1
packet for 32oz of water. Do not change the ratio. It can also be used for
other humidifier brands. Thorougly rinse the base with potable water and make
sure no EZCal residues remain in the base! EZCal is available at selected
retail stores and online www.airoswiss.net.
Please check our website www.airoswiss.net for
further information.