echo EH2P Hydrogen Water Pitcher Owner’s Manual
- August 8, 2024
- ECHO
Table of Contents
EH2P Hydrogen Water Pitcher
“`html
Specifications:
-
Produces hydrogen-enriched water in 10 and 20-minute
cycles -
Up to 1.4 ppm of molecular hydrogen for the 10-minute cycle or
up to 1.7 ppm for the 20-minute cycle -
Specialized casing keeps hydrogenated water pure and fresh
-
Built-in rechargeable battery for portable use
-
Eco-friendly tritan plastic construction, BPA free
Product Usage Instructions:
Safety Instructions:
-
Remove moisture retention caps before use
-
Charge using only DC 5V, do not exceed DC 5V – 2A
-
Do not charge for more than 5 hours or leave charging
overnight -
Keep the oxygen outlet unobstructed
-
Use manufacturer-certified replacement parts and charging
cables -
Do not use the pitcher without water to avoid electrode
damage -
Clean the pitcher with citric acid or vinegar, avoid chemical
detergents
Maintenance Instructions:
-
If electrodes have calcium buildup or are damaged, performance
may be affected -
Do not clean the interior with chemical detergent, only use
water for exterior cleaning -
If not used for a week, fill with 8oz/236ml water at
~115°F/46°C and remove after 20 minutes -
Use only filtered water (Reverse Osmosis, Filtered, or
Distilled Water) for hydrogenation process
Unboxing Instructions:
Connect the C-type USB Cable to the outlet adapter and the USB
port of the pitcher for charging. Charging time is between 3-5
hours.
Frequently Asked Questions (FAQ):
Q: How often should I clean the pitcher?
A: It is recommended to clean the pitcher using citric acid or
vinegar regularly to maintain optimal performance.
Q: Can I use tap water with the pitcher?
A: It is advised to use only filtered water (Reverse Osmosis,
Filtered, or Distilled Water) for the hydrogenation process to
prevent any issues.
Q: What should I do if the product is not used for an extended
period?
A: If the product has not been used for a week or longer, fill
it with 8oz/236ml water at ~115°F/46°C and remove the water after
20 minutes to maintain its functionality.
“`
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Categories
Submit a request Sign in
Echo Water Technical Support Echo Pitcher – Warranty / Install
Hydrogen Water Pitcher Manual
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
1/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
2/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
3/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Bene ts of Hydrogen Water Pitcher
The Hydrogen Water Pitcher can produce hydrogen-enriched water in 10 and
20-minute cycles. Producing up to 1.4 ppm of molecular hydrogen for the
10-minute cycle or up to 1.7 ppm of molecular hydrogen for the 20minute cycle.
Specialized casing keeps hydrogenated water pure and fresh after creating
enriched hydrogen water.
Built-in rechargeable battery allows the Echo H2 water Pitcher to be used
anytime and anywhere.
Eco-friendly and made of tritan plastic which is BPA free.
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
4/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
SAFETY INSTRUCTIONS
Please be sure to follow these instructions to prevent electric shock, re, or explosion which could result in personal injury or product damage
DO NOT
Put the pitcher in the Microwave, Dishwasher, Fridge, or Freezer Disassemble,
repair, or modify the pitcher. Soak your product in water. (Cover can be
washed.) Use the product if an abnormality occurs. Touch the power plug with
wet hands; this can cause electric shock, re, and product failure. Allow the
product to be left on charge longer than 5 hours. Allow children to operate or
handle the pitcher Use carbonated beverages, alcohol, or any additives, such
as tea, in the pitcher Water that has chlorine will damage the hydrogen
generator. Use water above 140°F/60 °C Move the pitcher during hydrogen
generation. Clean the interior of the pitcher with chemical detergent. The
electrode will be damaged. Use only water when cleaning. Use excessive force
if the product falls, is thrown, or is dropped call Customer Care
SAFETY INSTRUCTIONS
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
5/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Please be sure to follow these instructions to prevent electric shock, re, or
explosion which could result in personal injury or product damage
Always remember to remove the moisture retention caps before use Use only DC 5V. Do not charge with a voltage higher than DC 5V -2A. Do Not exceed a 5-hour charge time. Never leave charging overnight. Keep the oxygen outlet on the underside of the pitcher unobstructed. Only use manufacturer-certi ed replacement parts and charging cables. Using the pitcher without water may cause electrode damage. When cleaning the pitcher use citric acid or vinegar.
If the electrodes have calcium buildup or are damaged, performance can be degraded. Do not clean the interior of the pitcher with chemical detergent.
Only use water when cleaning the exterior of the pitcher. Other
detergents/chemicals may cause the pitcher to be discolored or lose paint.
If the electrodes are completely dry or the product has not been used for one
week or longer. Fill the pitcher with 8oz/236ml water at ~115 degrees F/46
degrees C. Remove water from the pitcher after 20 minutes.
Only use ltered water (Reverse Osmosis, Filtered, or Distilled Water) in the
hydrogenation process.
UNBOXING THE HYDROGEN WATER PITCHER
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
6/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
8:12
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
7/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
8/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
For Outlet Charging: Connect the C-type USB Cable to the outlet adapter and the USB port of the pitcher. Charging timeframe is between 3-5 hours.
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
9/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Using a Portable Charger:
Charge the portable charger before use. Connect the C-type USB cable to the
portable charger and to the USB port of the Pitcher.
The product can be used while charging. If the battery display LED is Red, the
pitcher is charging. If the LED Display is Green, the pitcher is fully
charged. Use a charging adapter with 5V, 2A, or higher. Hydrogen generation is
more effective when the pitcher is fully charged. Do Not leave on charger
longer than 5 hours. Extended use will degrade the battery.
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
10/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
11/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Before rst use, open the top cover and unscrew and remove the electrode
moisture retention caps (2 pieces) inside the water pitcher. The moisture
retention caps prevent electrodes from drying out during distribution.
If the pitcher will not be used for more than a week, ll the electrodes with
water and lock the moisture retention cap by screwing them in place. It is
important to remove caps before the next use.
For rst use or if you have not used the pitcher for more than one week, follow
cleaning procedures.
Open the top cover and ll it with ltered water (Reverse Osmosis Water or
Distilled Water).
10 Minute Cycle:
Press and hold the Hydrogen Water sensor for 2 seconds and the BLUE LED
will light up at the bottom. The display will show 10 minutes. After 10
minutes, the Hydrogen Water Pitcher will turn off automatically. it is normal
for the
BLUE LED light to ash while the cycle is running.
20 Minute Cycle:
For higher concentrations of hydrogen, press the operating sensor twice and
the GREEN LED will light on the bottom. After 20 minutes, the Hydrogen
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
12/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Water Pitcher will turn off automatically. It is normal for the GREEN LED light
to ash while the cycle is running.
TUTORIAL ON HOW TO USE YOUR HYDROGEN WATER PITCHER
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
13/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
3:30
Pitcher Cleaning Cycle
To run a cleaning cycle, place your nger on the cleaning sensor and hold for 5
seconds. Please reference the above image to know which is the cleaning
sensor. Please keep in mind this is Heat sensitive and not a button. Please
make sure your nger is warm when trying to activate this button.
Deep Cleaning Procedure
When using for the rst time, remove retention caps.
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
14/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Baking soda cleaning method: In a separate cup, dissolve 2 tsp/10g of
baking soda into approx. ¼ cup (50cc) of warm water (68°F~104°F/20 ~
40). Let the baking soda dissolve
Once fully dissolved, pour the water/baking soda solution into the Pitcher and
leave for about 1 hour. (leaving it for 1-2 hours will have a better cleaning
effect.)
After 1 hour, rinse with water (Distilled Water or RO water) 2 ~ 3 times
before the next step.
Cleaning Cycle Mode: Fill the Pitcher with water(Distilled Water or RO water around (68°F~104°F/20 ~ 40) about 2/3 full and run the cleaning mode 2 ~ 3 times.
For best results change the water each time ( ashing RED LED turns
on when cleaning mode is activated)
Clean the inside with a soft cloth, cotton swab, or sponge. If dust or dirt is
not removed, add some water and gently swirl several times.
For the best outcome, use the cleaning cycle mode weekly. For deep cleaning, use the baking soda cleaning method.
When there is mineral buildup, use the vinegar method (instructions below)
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
15/21
7/24/24, 10:55 AM
Extra Cleaning Tips
Hydrogen Water Pitcher Manual Echo Water
Vinegar Method
Pour 8oz/236ml of vinegar into the pitcher and let sit overnight Rinse with water (Distilled Water or RO water) 2 ~ 3 times before use.
Water that is rich in minerals may have cloudy bubbles and fewer hydrogen
bubbles. If there are fewer hydrogen bubbles, use the cleaning cycle mode
before use.
Water Container Cleaning-Clean the Pitcher with a soft cloth or sponge, etc.,
and thoroughly rinse it before use.
Product Appearance -Wipe off dust and dirt from the pitcher/kettle with a wet
cloth. (Keep water away from the power terminal and battery)
Long-term use of the pitcher/kettle may cause the electrode to smell. The smell of the electrodes has nothing to do with hydrogen production and does not affect the taste of water. Periodically, clean the electrode and pitcher/kettle to prevent odors. The smell may require several cycles of cleaning to remove.
Descaling Process Depending on the mineral content in your ltered water, you may need to clean the electrodes once or twice a month.
To descale, add 1 part or 1oz white vinegar, lemon juice, or citric acid and 3
parts or 3oz water by pouring it into the unit and leaving the generator
soaking in the mix overnight.
Dump and rinse thoroughly with warm water before using the next day
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
16/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Please check the following before requesting repairs. If the same abnormality occurs after the action is taken, please contact customer service at support@echowater.com
Problem
Hydrogen bubbles are weak or not generated.
Cause
Solution
The product is not at full Check the battery and
power or charged.
charge if needed.
Foreign matter in the electrode.
Clean the electrodes according to the descaling process listed above
The bottom oxygen outlet is blocked.
Position the oxygen outlet on the bottom so that it is not obstructed.
Not used for an extended period of time.
Add water to electrodes, and continue to use the pitcher to stabilize.
LED is not illuminated.
The product is not charged.
Check the battery and charge if needed.
Wet electrodes with
water. Continue using
Thick bubbles occur.
Electrodes are dry or not yet stabilized.
the pitcher to stabilize. Operate 2 or 3 times
with warm water
(140°F/60°C or less).
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
17/21
7/24/24, 10:55 AM
Low battery light blinks during hydrogen water generation.
Hydrogen Water Pitcher Manual Echo Water
Low Battery.
Charge the Hydrogen Water Pitcher.
Poor Connection
Check that the charging terminal and cable have a solid connection
Not Charging
Charger or cable failure
Check for visible cable damage. Use a different USB C cable, use a different USB/Outlet adapter
Hydrogen water generates a ne mist
Unstable electrodes
Turn off the power, clean, and stabilize
Small leaks to the oxygen outlet
Drying/dried electrode part
Pour warm water (less than 140°F/60°C) to use the electrode area suf ciently wet for more than 10 minutes
Operation sound when hydrogen water is generated.
Hydrogen bubble generation sound
This is a normal occurrence
Odor from electrodes
Prolonged period since cleaning
Clean system
The cleaning sensor is not working
Finger/Hands are cold.
Warm up your hands and try lightly placing your nger on the cleaning sensor.
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
18/21
7/24/24, 10:55 AM
Hydrogen Water Pitcher Manual Echo Water
Name of Model Hydrogen Capacity
ORP Use Temperature
Echo H2 Pitcher
1,700 cc
1.7 liter
-450 ~ -900 mV
10 ~ 40 °C
50 ~ 104 F
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
19/21
7/24/24, 10:55 AM
Body Weight
Size
Operating Time Charge Time
Hydrogen Water Pitcher Manual Echo Water
About 850g
About 1.9 lbs
W 216 × D 103 × H 268mm
W 8.5 x D 4.05 x H 10.55 in
10 minutes or 20 minutes
About 90 ~ 150 min
DC 5V 2A
5-Year Product Warranty
Product
Echo H2 Pitcher Model Number
EH2P
Serial Number
Date of Purchase
Company
Echo Technologies Customer
LLC
Support Phone
+1-855-737-1114
Company website
www.echowater.com
Customer Support Email
support@echowater.com
Notes:
Related to: Hydrogen Water Pitcher
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water-
Pitcher-Manual
20/21
7/24/24, 10:55 AM
Attachments
Hydrogen Water Pitcher Manual Echo Water
Hydrogen Water Pitcher User Manual.pdf 071423.pdf
(1 MB)
Recently viewed articles
Echo Go+TM Manual
Articles in this section
Echo Pitcher Warranty Guide Read This: Hydrogen Water Pitcher Hydrogen Water
Pitcher Manual How to replace the battery on an Echo Water Pitcher:
Add comment
Article is closed for comments.
© Echo Technologies LLC
https://support.echowater.com/hc/en-us/articles/16860901351060-Hydrogen-Water- Pitcher-Manual
21/21
References
- Echo Hydrogen Water
- Echo Hydrogen Water
- Echo Water
- Echo Water
- How to replace the battery on an Echo Water Pitcher: – Echo Water
- Echo Pitcher Warranty Guide – Echo Water
- Submit a request – Echo Water
- Search results – Echo Water
- Echo Pitcher - Warranty / Install – Echo Water
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>