MICROTECH IP67 Long Jaw Digital Caliper User Manual
- August 6, 2024
- microtech
Table of Contents
MICROTECH IP67 Long Jaw Digital Caliper
SPECIFICATION
Item No
| Range| Resol| Jaw| Accur.| Bar section|
Weight| Protection| mm/inch| Preset| ABS|
WIRELESS
---|---|---|---|---|---|---|---|---|---|---|---
mm| inch| mm| mm| μm| mm| kg
MICRON LONG JAW DIGITAL CALIPER IP67
141073301| 0-300| 0-12″|
0,001
| 100| ±15|
23×6
| 1.11|
IP67
| •| •| •|
141073501| 0-500| 0-20”|
±20
| 1,45| •| •| •|
141073502| 150| 1,75| •| •| •|
141073601| 0-600| 0-24”| 100| 1,66| •| •| •|
141073702| 0-1000| 0-40”| 150| ±30| 32×7| 3,32| •| •| •|
LONG JAW DIGITAL CALIPER IP67
141072311| 0-300| 0-12”|
0,01
|
100
|
±30
|
17×5
| 0,69|
IP67
| •| •| •|
141072411| 0-400| 0-16”| 0,79| •| •| •|
141072511| 0-500| 0-20”| 0,88| •| •| •|
141073512| 0-500| 0-20”| 150| ±30| 23×6| 1,7|
IP67
Al case
| •| •| •|
141073515| 300| ±40| 2,7| •| •| •|
141073611| 0-600| 0-24″| 100| ±30| 1,7| •| •| •|
141073712| 0-1000| 0-40″| 150| ±40| 32×7| 3,3| •| •| •|
141073715| 300| ±60| 5,7| •| •| •|
141073812| 0-1500| 0-60″| 150| ±50|
42×8
| 5,2| •| •| •|
141073815| 300| ±70| 7,1| •| •| •|
141073912| 0-2000| 0-80″| 150| ±60| 7,1| •| •| •|
141073915|
300
| ±80| 8,6| •| •| •|
141073255| 0-2500| 0-100′| ±90|
53×8
| | •| •| •|
141073305| 0-3000| 0-120′| ±100| | •| •| •|
141073405| 0-4000| 0-160′| ±130| | •| •| •|
141073505| 0-5000| 0-200′| ±160| | •| •| •|
BUTTON FUNCTIONS
SET – Functions setting: PRESET, LIMITS, UNITS, MIN/MAX
DATA – Favorite key to one of the most used function
0 – Setting 0, PRESET value
OPERATION INSTRUCTIONS
Wipe with a clean cloth, soaked in gasoline, measuring surface of the frame
and gauge calipers to remove anti-corrosion oil. Then wipe them with a clean
dry cloth.
If necessary, open the battery cover; insert the battery (type CR2032)
according to the polarity of the electrodes.
This caliper has Autoswitch on/ off function:
- move electronic module for switch on caliper
- after 10 minutes without any moving caliper will switch off
During the measurement, measuring jaws should to sum to the measured object
without knocking.
During the measurement avoid warps of measuring surfaces of the instrument.
Measuring surface must be fully in contact with the measurement object
WARNING IN THE PROCESS OF WORKING WITH CALIPERS SHOULD BE AVOIDED:
Scratches on the measuring surfaces;
Measuring the size of object in the process of machining;
Shocks or dropping, avoid bending of rod or other surfaces.
BATTERY REPLACEMENT
CR2032 BATTERY (3V)
INDUSTRY 4.0 INSTRUMENTS
MICROTECH
innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50
www.microtech.ua
tool@microtech.ua
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>