poolcomet 0000136924 pH Domotic 2 Idegis Pump Installation Guide

August 4, 2024
Poolcomet

poolcomet 0000136924 pH Domotic 2 Idegis Pump

Product: Pump pH

Specifications:

  • Model: Pump pH
  • Code: 0000136924 rev. 2.0
  • Adjustable pH range: 6.2 to 7.8
  • pH Step Increments: 0.1

Product Features

The Pump pH has the following key features:

  • Priming position for pump operation
  • Normal position for pH measurement and dosing
  • Standby position for pump stoppage
  • Calibration menu for pH probe adjustment
  • Setup menu for adjusting dosage method (acid or alkaline)

Frequently Asked Questions (FAQ):
Q: What should I do if the real measure is below 6.0 pH or above 8.0 pH?
A: In such cases, the Setpoint value will start flashing,  indicating that the real measure is out of range. Adjust accordingly within the specified range.

General Features

  • Power Supply 100÷240 Vac
  • Display 4 digits with 7 segments
  • Bnc connection for probe pH
  • Switch 3 position Priming, ON, Stand by
  • Peristaltic pump flowrate and pressure look at label on product
  • Measure Range pH: 6÷8 pH (resolution: 0.1 PH)
  • Dosage method ON-OFF ( Set Point adjustable)
  • Calibration method pH 1 Point

Switch position

  1. Priming position “the pump running” (Switch position MOM)
  2.  Normal position “the instrument measure pH and dosing. (Switch position ON)
    • Keep Press key for 5 seconds to run calibration menu:
    • pH probe: the pump displays C7pH press key and wait 60 seconds
    • Displays quality probe ex: C100
    • Keep Press key until flashing Setpoint value press again to increase the value
    • when you are ready to leave a key after 3 seconds the unit save the value and flashing mem.
    • Value to set from 6.2 until 7.8 pH increase step by step 0.1 pH,
    • When the real measure is less than 6.0 pH Flashing the value
    • When the real measure is more than 8.0 pH Flashing the value
  3. Stand by position “The pump is stop” (Switch position OFF)
    Keep Press key for 3 seconds to run Setup menu:

pH setup menu:

  1. Adjust dosage method for pH Acid or Alka
  2. Temperature fixed Value 25°C

code: 0000136924 rev. 2.0

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals