Poolcomet PAPI004203-M Steering Module Instruction Manual

June 21, 2024
Poolcomet

Poolcomet PAPI004203-M Steering Module

Product Information

Specifications

  • Product Model : PAPI004203-M
  • Version : 20.08

Product Usage Instructions

Principle of Operation
The steering module allows for various control options:

  • Operating Mode
  • Boost Mode

Interface

  • Screen
  • Indicators/Lights
  • Control Buttons

Settings
The module offers the following settings:

  • Operating Mode
  • Boost Mode
  • Automatic Steering Mode
  • Time Ranges for Automatic Steering
  • Blind Mode
  • Clock Settings

Resetting Parameters
To reset parameters, follow the instructions provided in the user manual.

Alarms
The module may trigger alarms in certain situations. Refer to the manual for alarm details and troubleshooting.

Warranty
The product comes with a warranty. Refer to the warranty section for details.

OPERATIONAL PRINCIPLE

Poolcomet-PAPI004203-M-Steering-Module-FIG- \(1\)

INTERFACE

Screen

  1. Overview**
    DISPLAY| MEANING**
    ---|---
    Fixed| Confirmed information or in read only
    Flashing| Information awaiting confirmation, or alarm set off
  2. Default displayPoolcomet-PAPI004203-M-Steering-Module-FIG- \(2\)

LEDs

REFERENCE STATUS MEANING
AUX. Red light Processing device (electrolyser, pH regulator) on
PUMP Lights up green Filtration pump on

Control keys

CONFIGURATION

Mode of operation

POSSIBLE SETTINGS MEANING
**** Automatic control filtration
**** Forced switch on of filtration
OFF Filtration off

DEFAULT SETTING:

To configure the settings :
Press x times on the key (does not require confirmation). If the chosen setting is « OFF », the message « OFF -» is displayed permanently.

Boost mode
Boost mode switches on the filtration for a 24-hour period.

POSSIBLE SETTINGS MEANING
ON Activating Boost mode
OFF Deactivating Boost mode
  1. To configure the settings: The mode of operation must be set in .
  2. Press and hold down the V key, until the message PRO1 is displayed.
  3. Press on the V key : the current setting flashes.
  4. Select a setting by pressing the key times.
  5. Confirm by pressing the V key: the setting freezes for a moment.

If the chosen setting is «ON», the message «b » flashes alternately with the mode of operation (horizontal segment).

To stop Boost mode before the end of the 24-hour period: Press on the C key.

Automatic control mode

Poolcomet-PAPI004203-M-Steering-Module-FIG- 11

Maximum water temperature

reached the previous day

| Filtration operating schedule

for the current day

---|---


| From 00:00 to 00:00

(i.e. a 24-hour period)

From 1 to 9°C| From 03:00 to 07:00
From 10 to 11°C| From 10:00 to 15:00
From 12 to 13°C| From 10:00 to 16:00
From 14 to 15°C| From 10:00 to 17:00
From 16 to 17°C| From 10:00 to 18:00
From 18 to 19°C| From 10:00 to 19:00
From 20 to 21°C| From 10:00 to 20:00
From 22 to 23°C| From 10:00 to 21:00
From 24 to 25°C| From 10:00 to 22:00
From 26 to 27°C| From 10:00 to 23:00
From 28 to 29°C| From 08:00 to 00:00


≥ 30°C

| From 00:00 to 00:00

(i.e. a 24-hour period)

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message PRO1 is displayed.
  3. Press on the key : the message PRO2 is displayed.
  4. Press on the V key : the current setting flashes.
  5. Select a setting by pressing the key times.
  6. Confirm by pressing the V key : the setting freezes for a moment.
  7. If the chosen setting is « » : the message is displayed for a few moments.

Automatic control time intervals

Poolcomet-PAPI004203-M-Steering-Module-FIG- 12

To program a time interval :

  1. The automatic control mode must be set in .
  2. Press and hold down the V key, until the message PRO1 is displayed.
  3. Press on the key : the message PRO2 is displayed.
  4. Press twice on the V key : the message is displayed.
  5. Select a time interval by pressing the key x times.
  6. Confirm by pressing the V key : the switch on time is displayed.
  7. Set the switch on time by pressing the key x times and then confirm using the V key for the hours and then the minutes. After this, the switch off time is displayed.
  8. Set the switch off time by pressing the key times and then confirm using the V key for the hours and then the minutes. After this, the time interval is displayed for a few moments.

To deprogram a time interval (switch on time and switch off time at 00.00 ) :

  1. The automatic control mode must be set in .
  2. Press and hold down the V key, until the message PRO1 is displayed.
  3. Press the key : the message PRO2 is displayed.
  4. Press twice on the V key : the message is displayed.
  5. Select a time interval by pressing the key times.
  6. Press and hold down the V key : the switch on time is set at 00.00 .
  7. Press the V key : the switch off time is set at 00.00 .
  8. Press twice on the V key : the time interval is displayed for a few moments.

Cover mode
The cover mode stops the treatment device every hour for a set period of time when the cover is closed.

Poolcomet-PAPI004203-M-Steering-Module-FIG- 14

To configure the settings :

    1. The mode of operation must be set in .
    1. Press and hold down the V key, until the message PRO1 is displayed.
    1. Press twice on the key : the message PRO3 is displayed.
    1. Press the V key : « » or « » flashes.
    1. Select « » or « » by pressing the key times.
    1. Confirm by pressing the V key : the setting freezes for a moment.
    1. If the chosen setting is « ON» :
  1. Select « NO» or «NC » by pressing the key times.
  2. Confirm by pressing the V key : the setting freezes for a moment.
  3. Select a setting from 00 to 50 by pressing the key times.
  4. Confirm by pressing the V key : the setting freezes for a moment.

When the (NO or NC) contact is activated, the « » index flashes alternately with the mode of operation (horizontal segment).

Clock

POSSIBLE SETTINGS DEFAULT SETTING

From  to  (i.e. from 00:00 to 23:59,

in steps of 1 hour and in steps of 1 min)

| Cumulative time since the first implementation of the control module, reset to  every 24 hours

To configure the settings :
  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message PRO1 is displayed.
  3. Press three times on the key : the message PRO4 is displayed.
  4. Press the V key : the current setting flashes.
  5. Set the hours by pressing the key times.
  6. Confirm by pressing the V key : the hour setting freezes for a moment.
  7. Set the minutes by pressing the key x times.
  8. Confirm by pressing the V key : the minute setting freezes for a moment.

Indoor pool mode
The indoor pool mode reduces the filtration time to 60 % per hour.

POSSIBLE SETTINGS MEANING
ON Activating indoor pool mode
OFF Deactivating indoor pool mode

DEFAULT SETTING: OFF

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message is PRO1 displayed.
  3. Press four times on the key : the message is PRO5 displayed.
  4. Press the V key : the current setting flashes.
  5. Select a setting by pressing the key times.
  6. Confirm by pressing the V key : the setting freezes for a moment.

Water flow safety lock

  • This safety lock: – requires prior installation and connection of a flow sensor (optional).
  • This safety lock: – stops the filtration as soon as the water flow is insufficient.

Poolcomet-PAPI004203-M-Steering-Module-FIG- 14

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message is PRO1 displayed.
  3. Press five times on the key: the message is PRO6 displayed.
  4. Press the V key : «ON » or «OFF » flashes.
  5. Select «ON » or «OFF» by pressing the key x times.
  6. Confirm by pressing the V key : the setting freezes for a moment.
  7. If the chosen setting is «ON » :
  8. Select « NO» or «NC » by pressing the  key x times.
  9. Confirm by pressing the V key : the setting freezes for a moment.

Water temperature safety lock

Poolcomet-PAPI004203-M-Steering-Module-FIG- 15

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message is PRO1 displayed.
  3. Press six times on the key : the message is PRO7 displayed.
  4. Press the V key : the current setting flashes.
  5. Select a setting by pressing the key x times.
  6. Confirm by pressing the V key : the setting freezes for a moment.

Calibration of the water temperature measurement

POSSIBLE SETTINGS DEFAULT SETTING

From  to  , in steps of 1,

within the limit of 10°C high or lower compared to the current measurement

| Current measurement

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message is PRO1 displayed.
  3. Press seven times on the key : the message is PRO8 displayed.
  4. Press the V key : the current measurement flashes.
  5. Select a setting by pressing the key x times.
  6. Confirm by pressing the V key : the setting freezes for a moment.

Temperature sensor

Poolcomet-PAPI004203-M-Steering-Module-FIG- 16

If the chosen setting is « OFF » :

  • The water temperature is not displayed.
  • The automatic control mode is set in « ».
  • The water temperature safety locks are deactivated.
  • The calibration of the water temperature measurement cannot be performed.

To configure the settings :

  1. The mode of operation must be set in .
  2. Press and hold down the V key, until the message is PRO1 displayed.
  3. Press eight times on the key : the message is PRO9 displayed.
  4. Press the V key : the current setting flashes.
  5. Select a setting by pressing the key x times.
  6. Confirm by pressing the V key : the setting freezes for a moment.

RESETTING THE PARAMETERS

Resetting the parameters resets all settings to the defaults, except the clock.

  1. Press and hold down the C and V keys simultaneously : the message «8.8.8.8» is displayed briefly, then the default display appears.
  2. Wait a few minutes until the message « » is displayed.
  3. Power down the electronics cabinet for a few seconds.
  4. Power up the electronics cabinet : after a few moments, the default display appears.

ALARMS

Poolcomet-PAPI004203-M-Steering-Module-FIG- 17

GUARANTEE

Before contacting your dealer, please have the following to hand :

  • your purchase invoice.
  • the serial n° of the electronics unit.
  • the installation date of the equipment.
  • the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.).

Every effort and all our technical experience has gone into designing this equipment. It has been subjected to quality controls. If, despite all the attention and expertise involved in its manufacture, you need to make use of our guarantee, it only applies to free

Guarantee period (proven by date of invoice)

  • Electronics unit : 2 years.
  • Repairs and spare parts : 3 months.

The periods indicated above correspond to standard guarantees. However, these can vary depending on the country of installation and the distribution network.

Scope of the guarantee

  • The guarantee covers all parts, with the exception of wearing parts that must be replaced regularly.
  • The equipment is guaranteed against all manufacturing defects within the strict limitations of normal use.

After-sales services

  • All repairs will be performed in the workshop.
  • Shipping costs in both directions are at the user’s own expense.
  • Any downtime and loss of use of a device in the event of repairs shall not give rise to any claim for compensation.
  • In all cases, the equipment is always sent at the user’s own risk. Before taking delivery, the user must ensure that it is in perfect condition and, if necessary, write down any reservations on the shipping note of the carrier. Confirm with the carrier within 72
  • hours by recorded letter with acknowledgement of receipt.
  • Replacement under guarantee shall in no case extend the original guarantee period.

Guarantee application limit

  • In order to improve the quality of their products, the manufacturer reserves the right to modify the characteristics of the products at any time without notice.
  • This documentation is provided for information purposes only and is not contractually binding with respect to third parties.  his documentation.
  • Installation, maintenance and, more generally, any servicing of the manufacturer’s products should only be performed by professionals. This work must also be carried out in accordance with the current standards in the country of installation at the time of
  • installation. The use of any parts other than the original parts voids the guarantee ipso facto for the entire equipment.

The following are excluded from the guarantee :

  • Equipment and labour provided by third parties in installing the device.
  • Damage caused by installation, not in compliance with the instructions.
  • Problems caused by modifications, accidents, misuse, negligence of professionals or end users, unauthorised repairs, fire, floods, lightning, freezing, armed conflict or any other force-majeure events.

Any equipment damaged due to non-compliance with the instructions regarding safety, installation, use and maintenance contained in this documentation will not be covered by the guarantee. Every year, we make improvements to our products and software. These new versions are compatible with previous models. The new versions of hardware and software cannot be added to earlier models under the guarantee.

Implementation of the guarantee
For more information regarding this guarantee, contact your dealer or our After-Sales Service. All requests must be accompanied by a copy of the purchase invoice.

Legislation and disputes
This guarantee is subject to French law and all European directives or international treaties in force at the time of the claim, applicable in France. In case of disputes concerning its interpretation or execution, the High Court of Montpellier (France) shall have exclusive jurisdiction.

FAQ

  • Q: How do I switch between different modes of operation?
    A: Use the control buttons to navigate and select the desired mode.

  • Q: What should I do if an alarm is activated?
    A: Refer to the alarm section of the manual to understand the alarm cause and resolution steps.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Poolcomet User Manuals

Related Manuals