SUNCO LIGHTING LS-RWPO2B-80W LED Wall Pack Light Fixture Instruction Manual
- June 25, 2024
- Sunco Lighting
Table of Contents
SUNCO LIGHTING LS-RWPO2B-80W LED Wall Pack Light Fixture
Specifications
- Model No: LS-RWPO2B-80W 1JYT1SA2-BR50
- Power Factor Correction (PFC): 0.9
- Wattage: 80W (Tunable)
- Voltage/Current Input:
- 120V, 0.66A
- 277V, 0.28A
- Light Efficiency: 135LM/W
- Kelvin Options: 5000K
Product Usage Instructions
- Installation & Mounting
- Warning: Please follow these instructions carefully to ensure safe and proper installation.
- Installation Notice:
- This luminaire must be installed by a qualified electrician to avoid electric shock and fire accidents.
- Wear gloves before installation to prevent injury.
- If there is smoke or fire during installation, turn off the power immediately and inform professionals for inspection.
- This luminaire is suitable for outdoor use.
- Installation Steps:
- Installation I: Wiring from the bottom of the luminaire
- Cut holes on the wall according to the locating plate.
- Fix rubber plugs into the holes.
- Align the mounting bracket with the hole and tighten the screws.
- Make wiring connections and ensure isolation treatment.
- Fix the luminaire on the bracket and tighten the screws on the bottom.
- After installation, ensure all screws are tightened.
- Installation II: Wiring from the bottom of the luminaire
- Cut holes on the wall according to the locating plate.
- Fix rubber plugs into the holes.
- Align the mounting bracket with the hole and tighten the screws.
- Fix the luminaire on the bracket and make wiring connections from the side, ensuring isolation treatment.
- Tighten the pipe on the luminaire and ensure all screws are tightened after installation.
FAQs
- Q: What should I do if the light is not working after installation?
- A: Check the power source, ensure proper wiring connections, and consult a professional if needed.
FEATURES
- Rotatable optics design, can either up or downlight
- Great architecture design, aluminium alloy housing
- Optics swivel 350 degrees in each direction
- IP65 waterproof
- 50,000 hours lifetime
SUITABLE APPLICATIONS
- Warehouses
- Stadiums
- Factories
- Parking Lots
- Shopping Malls
- Supermarkets
- Logistic Centers
- Auto dealerships
CONSTRUCTION:
- Aluminum alloy housing with bronze powder-coated finish
OPTICAL SYSTEM:
- High brightness Lumileds 2835 chips
- High Transmission PC optics
- 60° beam angle
WARRANTY
- 5-year limited warranty. Actual performance may differ as a result of end-user environment and application.
ELECTRICAL:
- Available as 120-277V input
- -4°F to 113°F
INSTALLATION & MOUNTING:
- Wall mounting with backside plate for easy install
CONTROLS & DIMMING:
- 0-10V dimmable
PERFORMANCE:
Model No| PFC| Wattage Tunable| Voltage/Current Input| Light Efficiency| Kelvin
Options
---|---|---|---|---|---
120V| 277V
LS-RWPO2B-80W 1JYT1SA2-BR50| >0.9| 80W| 0.66A| 0.28A| 135LM/W| 5000K
Electric Characteristic
Specification/Model | LDS-WPB-80W-120V-50K-V2 |
---|---|
LED Driver | UL driver |
Input Power | 80W |
Lumens Output | 10800LM |
Efficiency | 135LM/W |
CRI | >72 |
Colour Temperature | 5000K |
Input Voltage | 120-277VAC |
Light Distribution Type | 60D |
Working Temperature | -4 ~ +113°F |
Junction Temperature | <167°F |
Lamps Efficiency | ≥90% |
Certificate | UL CUL DLC |
Equivalent | 200-250W MH/HPS |
Dimension
Distribution Diagram
Note
- The installation and maintenance must be completed by electricians or professionals.
- Please cut off the power before installation and maintenance.
- The thermally insulating material is not allowed to cover the fixture.
- Please keep away from the corrosive substance.
Installation Instruction
Warning:
- Can not use the electric generator to test the LED lamp.
- This luminaire must be installed following your local electrical codes and requirements.
- Do not install the luminaire in the rain, to avoid lightning stroke and damage to the luminaire.
Installation Notice:
- This luminaire must be installed by a qualified electrician to avoid electric shock and fire accidents;
- Wear gloves before installation to avoid injury;
- Turn off the power immediately when there is smoke and fire during installation; inform professionals to overhaul;
- This luminaire is suited for outdoor use.
- The installation of the product can be used when it is marked with “√ “.
Installation I: Wiring from the bottom of the luminaire
- Cut holes in the wall according to locating the plate. (Figure 1-1)
- Fix rubber plugs into holes. (Figure 1-2)
- Align mounting bracket with hole; tightens crews. (Figure 1-3)
- Make a wiring connection and go through isolation treatment. ( Figure 1-4)
- Fix the luminaire on the bracket and tighten the screws on the bottom. (Figure 1-5)
- After installation, tighten the screws. (Figure 1-6)
Installation II: Wiring from the bottom of the luminaire
- Cut holes in the wall according to locating the plate. (Figure 2-1)
- Fix rubber plugs into holes. (Figure 2-2)
- Align mounting bracket with hole; tighten screws. (Figure 2-3)
- Fix the luminaire on the bracket; make a wiring connection from the side and go through isolation treatment. (Figure 2-4)
- Tighten the pipe on the luminaire; after installation, tighten the screws. (Figure 2-5)
Installation II: Bracket installation
- Cut holes in the wall according to locating the plate. (Figure 3-1)
- Fix rubber plugs into holes. (Figure 3-2)
- Align mounting bracket with hole; tighten screws. (Figure 3-3)
- Pass wires through rubber ring and junction box, align with holes and lock junction box. (Figure 3-4)
- Make a wiring connection and go through isolation treatment. (Figure 3-5)
- Push the wires into the junction box; after installation, tighten the screws. (Figure 3-6)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>