Specifications

  • Product Name:  Slim Mount Ring Scanner Hand Mount
  • Model Number:  SG-RS2X-HMTLA-01 (Left-handed) / SG-RS2X-HMTRA-01 (Right-handed)
  • Design:  One-size-fits-all design for left and right-handed users
  • Features:  Trigger finger strap, scanner slot, slot tab, trigger contacts, wrist strap

Product Usage Instructions

Mounting the Scanner

  1. Push the LED-end of the scanner into the plastic slot on the Slim Mount.
  2. Press the front end of the scanner into the slot firmly until the tabs close around the scanner’s tab notches.
  3. The scanner is now ready for use.

Removing the Scanner

  1. Stabilize the mount with your thumb and middle finger.
  2. Using your index finger, pull up on the front end of the scanner until it disengages from the mount.
  3. Ensure the mount does not lift off your hand when removing the scanner to prevent premature wear of the elastic material.
  4. Lift the rest of the scanner out of the mount.

Cleaning Instructions
To clean the Slim Mount:

  1. Remove the scanner from the Slim Mount.
  2. Use an approved cleaning agent or mild detergent on the fabric. Keep the fabric around the trigger dry.

FAQ

  • Q: Can I use the Slim Mount for both left and right-handed users?
    A: Yes, the Slim Mount is designed to be a one-size-fits-all solution for both left and right-handed users.

  • Q: How do I know which configuration is suitable for my hand?
    A: The green L on the scanner slot label indicates the left-handed Slim Mount configuration. Choose accordingly based on your dominant hand.

2024/03/07
ZEBRA and the stylized Zebra head are trademarks of Zebra Technologies Corporation, registered in many jurisdictions worldwide. All other trademarks are the property of their respective owners. ©2024 Zebra Technologies Corporation and/or its affiliates. All rights reserved. Information in this document is subject to change without notice. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of those agreements.
For further information regarding legal and proprietary statements, please go to:
SOFTWARE:  zebra.com/linkoslegal.
COPYRIGHTS:  zebra.com/copyright.
PATENTS:  ip.zebra.com.
WARRANTY:  zebra.com/warranty.
END USER LICENSE AGREEMENT:  zebra.com/eula.

Terms of Use

Proprietary Statement
This manual contains proprietary information of Zebra Technologies Corporation and its subsidiaries (“Zebra Technologies”). It is intended solely for the information and use of parties operating and maintaining the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the express, written permission of Zebra Technologies.

Product Improvements
Continuous improvement of products is a policy of Zebra Technologies. All specifications and designs are subject to change without notice.

Liability Disclaimer
Zebra Technologies takes steps to ensure that its published Engineering specifications and manuals are correct; however, errors do occur. Zebra Technologies reserves the right to correct any such errors and disclaims liability resulting therefrom.

Limitation of Liability
In no event shall Zebra Technologies or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any damages whatsoever (including, without limitation, consequential damages including loss of business profits, business interruption, or loss of business information) arising out of the use of, the results of use of, or inability to use such product, even if Zebra Technologies has been advised of the possibility of such damages. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

Introduction

The Slim Mount allows you to wear the RS2100 on the back of your hand and provides a remote finger trigger. The Slim Mount is a one-size-fits-all design for left and right-handed users. A green L on the scanner slot label indicates the left-handed Slim Mount configuration.

This guide covers the following configurations:

Part Number Description
SG-RS2X-HMTLA-01 Left-handed mount for RS2100.
SG-RS2X-HMTRA-01 Right-handed mount for RS2100.

Features

This section lists the features of the Slim Mount.

Item Description
1 Trigger
2 Finger strap
3 Scanner slot
4 Slot tab
5 Trigger contacts
6 Wrist strap

Mounting the Scanner

Mount the scanner onto the Slim Mount.

  1. Push the LED-end of the scanner into the plastic slot.
  2. Press the front end of the scanner into the slot. Push down firmly until the tabs close around the scanner’s tab notches.

Removing the Scanner
Remove the RS2100 from the Slim Mount to charge the scanner or clean the Slim Mount.

  1. Stabilize the mount with your thumb and middle finger.

  2. Using your index finger, pull up on the front end of the scanner until it disengages from the mount.
    CAUTION: Ensure the mount does not lift up off of your hand when pulling up on the scanner. This protects the elastic material from wearing out prematurely.

  3. Lift the rest of the scanner out of the mount.

Cleaning Instructions

Use cleaners with approved ingredients to clean the Slim Mount.
CAUTION:  Always wear eye protection. Read warning labels on compressed air and alcohol products before using. If you have to use any other solution for medical reasons, contact Zebra for more information.
NOTE:  Avoid exposing this product to contact with hot oil or other flammable liquids. If such exposure occurs, clean the product immediately per these guidelines.

Approved Cleanser Active Ingredients
100% of the active ingredients in any cleaner must consist of one or some combination of the following:

  • Isopropyl alcohol
  • Mild dish soap

Harmful Ingredients
The following chemicals are known to damage the plastics on the device and should not come in contact with it:

  • Ammonia solutions
  • Compaounds of amines or ammonia
  • Acetone
  • Ketones
  • Ethers
  • Aromatic and chlorinated hydrocarbons
  • Aqueous or alcoholic alkaline solutions
  • Ethanolamine
  • Toluene
  • Trichloroethylene
  • Benzene
  • Carbolic acid
  • TB-lysoform
        • Bleach products
  • Hydrogen peroxide

Cleaning the Slim Mount
To clean the Slim Mount:

  1. Remove the scanner from the Slim Mount.
  2. Use an approved cleaning agent or mild detergent on the fabric. Keep the fabric around the trigger dry.
  3. Air dry the fabric.
    1. Use a soft brush or compressed air to remove debris from the trigger contacts inside the plastic scanner mount.
      CAUTION:  Cleaning cloth may damage the trigger contacts.