KERN EOB Platform Floor Scales Instruction Manual

August 2, 2024
KERN

KERN EOB Platform Floor Scales

Specifications

Model KERN EOB KERN EOE
Trademark KERN (Type) KERN (Type)
Readability (d) 10 g – 50 g 5 g – 50 g
Weighing range (max) 35 kg – 300 kg 15 kg – 150 kg
Product Usage Instructions
  1. Setup
    Place the platform/floor scale on a flat and stable surface. Ensure it is connected to a power source within the specified voltage range.

  2. Calibration
    Before use, calibrate the scale using the recommended adjustment weight provided in the manual. Follow the calibration instructions carefully.

  3. Weighing
    Place the item to be weighed on the center of the scale’s platform. Wait for the stabilization time to ensure an accurate reading.

  4. Power Management
    The scale has an auto-off feature to conserve battery life. Make sure to turn off the scale when not in use to prolong the battery operation period.

  5. Unit Conversion
    You can switch between different weighing units as needed. Refer to the manual for instructions on changing the weighing units.

Technical data

Models KERN EOB

KERN (Type)| EOB 10K-3B| EOB 30K-2B| EOB 60K- 2B| EOB 60K-2LB
---|---|---|---|---
Trademark| EOB

15K5

| EOB

35K10

| EOB

60K20

| EOB

60K20L

Readability (d)| 5 g| 10 g| 20 g| 20 g
Weighing range (max)| 15 kg| 35 kg| 60 kg| 60 kg
Reproducibility| 5 g| 10 g| 20 g| 20 g
Linearity| ± 10 g| ± 20 g| ± 40 g| ± 40 g
Recommended adjustment weight, not added (class)| ****

10 kg (M2)

| ****

20 kg (M2)

| ****

40 kg (M2)

| ****

40 kg (M2)

Stabilization time (typical)| 3 sec.
Warm-up time| 10 min
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack secondary voltage| 9V, 100 mA
Battery| 4 x 1.5 V AA (= 6 V)
Battery operation period| 60 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 5℃ …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 180 cm| 180 cm| 180 cm| 270 cm
Weighing surface mm| 300 x 300| 550 x 550
Weight kg (net)| 4.2| 13.5
KERN (Type)| EOB

100K- 2B

| EOB

100K- 2LB

| EOB

100K- 2XLB

---|---|---|---
Trademark| EOB

150K50

| EOB

150K-50L

| EOB

150K50XL

Readability (d)| 50 g| 50 g| 50 g
Weighing range (max)| 150 kg| 150 kg| 150 kg
Reproducibility| 50 g| 50 g| 50 g
Linearity| ± 100 g| ± 100 g| ± 100 g
Recommended adjustment weight, not added (class)| ****

100 kg (M2)

| ****

100 kg (M2)

| ****

100 kg (M2)

Stabilization time (typical)| 3 sec.
Warm-up time| 10 min
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack secondary voltage| 9V, 100 mA
Battery| 4 x 1.5 V AA (= 6 V)
Battery operation period| 60 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 5°C …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 180 cm| 270 cm| 270 cm
Weighing surface mm| 300 x 300| 550 x 550| 950 x 500
Weight kg (net)| 4.2| 13.5| 19.5
KERN (Type)| EOB

300K- 1B

| EOB

300K- 1LB

| EOB

300K- 1XLB

---|---|---|---
Trademark| EOB

300K100

| EOB

300K100L

| EOB

300K100XL

Readability (d)| 100 g| 100 g| 100 g
Weighing range (max)| 300 kg| 300 kg| 300 kg
Reproducibility| 100 g| 100 g| 100 g
Linearity| ± 200 g| ± 200 g| ± 200 g
Recommended adjustment weight, not added (class)| ****

300 kg (M2)

| ****

300 kg (M2)

| ****

300 kg (M2)

Stabilization time (typical)| 3 sec.
Warm-up time| 10 min.
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack secondary voltage| 9V, 100 mA
Battery (optional)| 4 x 1.5 V AA (= 6 V)
Battery operation period| 220 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 10°C …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 180 cm| 270 cm| 270 cm
Weighing surface mm| 300 x 300| 550 x 550| 945 x 505
Weight kg (net)| 4.2| 13.5| 19.5

Models KERN EOE

KERN (Type)| EOE 10K-3B| EOE 30K-2B| EOE 60K- 2B| EOE 60K-2LB| EOE 100K-2B
---|---|---|---|---|---
Trademark| EOE

10K-3

| EOE

30K-2

| EOE

60K-2

| EOE

60K-2L

| EOE

100K-2

Readability (d)| 5 g| 10 g| 20 g| 20 g| 50 g
Weighing range (max)| 15 kg| 35 kg| 60 kg| 60 kg| 150 kg
Reproducibility| 5 g| 10 g| 20 g| 20 g| 50 g
Linearity| ± 10 g| ± 20 g| ± 40 g| ± 40 g| ± 100 g
Recommended adjustment weight, not added (class)| ****

10 kg (M3)

| ****

20 kg (M2)

| ****

40 kg (M2)

| ****

40 kg (M2)

| ****

100 kg (M2)

Stabilization time (typical)| 2.5 sec.
Warm-up time| 10 min.
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack secondary voltage| 9V, 100 mA
Battery (optional)| 4 x 1.5 V AA (= 6 V)
Battery operation period| 100 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 5°C …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 180 cm| 270 cm| 180 cm
Weighing surface mm| 300 x 300| 550 x 550| 315 x 305
Weight kg (net)| 3.8| 3.8| 3.8| 13| 3.8
KERN (Type)| EOE 100K-2LB| EOE 100K-

2XLB

| EOE 300K-1B| EOE 300K-1LB| EOE 300K-

1XLB

---|---|---|---|---|---
Trademark| EOE

150K50L

| EOE

150K50XL

| EOE

300K100

| EOE

300K100L

| EOE 300K100XL
Readability (d)| 50 g| 50 g| 100 g| 100 g| 100 g
Weighing range (max)| 150 kg| 150 kg| 300 kg| 300 kg| 300 kg
Reproducibility| 50 g| 50 g| 100 g| 100 g| 100 g
Linearity| ± 100 g| ± 100 g| ± 200 g| ± 200 g| ± 200 g
Recommended adjustment weight, not added (class)| ****

100 kg (M3)

| ****

100 kg (M2)

| ****

300 kg (M2)

| ****

300 kg (M2)

| ****

300 kg (M2)

Stabilization time (typical)| 3 sec.
Warm-up time| 10 min.
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack

secondary voltage

| 9V, 100 mA
Battery (optional)| 4 x 1.5 V AA (= 6 V)
Battery operation period| 100 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 5℃ …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 270 cm| 180 cm| 270 cm
Weighing surface mm| 505 x 505| 950 x 500| 300 x 300| 550 x 550| 950 x 500
Weight kg (net)| 13,0| 18.0| 3.8| 13.0| 18.0

Models KERN EOS

KERN (Type) EOS 100K-2BXL EOS 300K-1BXL
Trademark EOS

150K50XL

| EOS

150K50XL

Readability (d)| 50 g| 100 g
Weighing range (max)| 150 kg| 300 kg
Reproducibility| 50 g| 100 g
Linearity| ± 100 g| ± 200 g
Recommended adjustment weight, not added (class)| ****

100 kg (M2)

| ****

300 kg (M2)

Stabilization time (typical)| 3 sec.
Warm-up time| 10 min.
Input Voltage| 220 V- 240 V, AC 50 Hz
Power pack secondary voltage| 9V, 100 mA
Battery (optional)| 4 x 1.5 V AA (= 6 V)
Battery operation period| 220 h
Auto-Off| 3 min
Weighing Units| kg, lb, pcs
Ambient temperature| + 10°C …+ 35°C
Humidity of air| max. 80 % (not condensing)
Display unit

(B x D x H) mm

| 235 x 114 x 51
Cable length display unit| 270 cm
Weighing surface mm| 900 x 550| 900 x 550
Weight kg (net)| 17.0| 17.0

Appliance overview

Models EOB
Weighing pan, stainless steel

Models EOE
Weighing pan varnished steel

Models EOS

  • Weighing pan, stainless steel
  • Anti-slip rubber mat

Comfortable transport due to 2 rollers and 1 grab handle

Overview of display

Example EOB:

Nr. Description
1 Balance zero display:

Should the balance not display exactly zero despite empty scale pan, press the

TARE button. The balance will be set to zero after a short standby time.

2| Stability display:

If the display shows the stability display [0] the balance is in a stable status. If the status is instable the [0] display disappears.

3| Stored tare value, see chap. 8.3 „Taring“
4| Gross weight display:

If the gross weight [Gross] appears in the display, the gross weight of the object and weighing container are displayed.

5| Hold/animal weighing function active, see chap. 8.4
6| Weighing unit [kg   lb]

Keyboard overview

Basic Information (General)

  1. Proper use
    The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic balance”, i.e. the material to be weighed is manually and carefully placed in the center of the weighing pan. As soon as a stable weighing value is reached the weighing value can be read.

  2. Improper Use

    • Do not use balance for dynamic add-on weighing procedures, if small amounts of goods to be weighed are removed or added. The “stability compensation“ installed in the balance may result in displaying an incorrect measuring value! (Example: Slowly draining fluids from a container on the balance.)
    • Do not leave permanent load on the weighing pan. This may damage the measuring system.
    • Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damaged by this.
    • Never operate balance in explosive environment. The serial version is not explosion-protected.
    • The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults, and destruction of the balance.
    • The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.
  3. Warranty
    Warranty claims shall be voided in case

    • Our conditions in the operation manual are ignored
    • The appliance is used outside the described uses
    • The appliance is modified or opened
    • Mechanical damage or damage by media, liquids, natural wear and tear
    • The appliance is improperly set up or incorrectly electrically connected
    • The measuring system is overloaded
  4. Monitoring of Test Resources
    In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern- sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) quickly and at a moderate cost.

Basic Safety Precautions

  1. Pay attention to the instructions in the Operation Manual
    Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.

  2. Personnel training
    The appliance may only be operated and maintained by trained personnel.

Transport and storage

  1. Testing upon acceptance
    When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.

  2. Packaging/return transport

    • Keep all parts of the original packaging for a possibly required return.
    • Only use original packaging for returning.
    • Prior to dispatch disconnect all cables and remove loose/mobile parts.
    • Reattach possibly supplied transport securing devices.
    • Secure all parts such as the glass wind screen, the weighing pan, the power unit etc. against shifting and damage.

Unpacking, Setup and Commissioning

Installation Site, Location of Use
The balances are designed in a way that reliable weighing results are achieved in common conditions of use.
You will work accurately and fast, if you select the right location for your balance.

Therefore, observe the following for the installation site:

  • Place the balance on a firm, level surface;
  • Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight;
  • Protect the balance against direct draughts due to open windows and doors;
  • Avoid jarring during weighing;
  • Protect the balance against high humidity, vapours and dust;
  • Do not expose the device to extreme dampness for longer periods of time. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature.
  • Avoid static charge of goods to be weighed or weighing container.

If electro-magnetic fields or static charge occur, or if the power supply is unstable major deviations on the display (incorrect weighing results) are possible. In that case, the location must be changed.

Unpacking and placing

  • Open package, take out the appliance and accessories. Verify that there has been no damage and that all packing items are present.
  • The balance must be installed in a way that the weighing pan is exactly in horizontal position.
  • Mount the display unit in a way that facilitates operation and where it is easy to see.

Scope of delivery / serial accessories

  • Platform and display unit, see chap. 2
  • Mains adapter
  • 4 x adjustable feet
  • Wall fixture (with fixing screws)
  • Operating manual

Mains connection

  • Select a country-specific power plug and insert it in the power unit.
  • Check, whether the voltage acceptance on the scales is set correctly. Do not connect the scales to the power grid unless the information on the scales (sticker) matches the local mains voltage.
  • Only use KERN original mains adapter. Using other makes requires consent by KERN.

Important:

  • Before starting your weighing balance, check the mains cable for damage.
  • Ensure that the power unit does not come into contact with liquids.
  • Ensure access to power plug at all times.

Battery operation

  • On the rear side of the display unit remove the battery cover and connect 4 x 1.5V mignon cells. Reinsert the battery cover.
  • In order to save the battery, the balance switches automatically off after 3 minutes without weighing. Additional switch-off times can be set in the menu (function “A.OFF”).
  • If the batteries are depleted, the battery symbol is displayed. Switch off balance and replace batteries at once.
  • If the balance is not used for a longer time, take out the batteries and store them separately. Leaking battery liquid could damage the balance.

Initial Commissioning

  • In order to obtain exact results with the electronic balances, your balance must have reached the operating temperature (see warming up time chap. During this warming-up time the balance must be connected to the power supply (mains, accumulator or battery).
  • The accuracy of the balance depends on the local acceleration of gravity.
  • Strictly observe hints in chapter Adjustment.

Adjustment

As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated – in compliance with the underlying physical weighing principle – to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out for the first commissioning, after each change of location as well as in case of fluctuating environment temperature. To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. Observe stable environmental conditions. A warming up time (see chapter 1) is required for stabilization.

An error message will be displayed in the event of an adjustment error or incorrect adjustment weight. Remove the adjustment weight and repeat the adjustment process.
Keep the adjustment weight close to the balance. Daily control of the weighing exactness is recommended for quality-relevant applications.

Operation

Start-up

Should the balance not display exactly zero despite empty weighing pan, press the button. The balance will be set to zero after a short standby time.

Switching Off

Taring

Hold function (animal weighing function)
The balance has an integrated animal weighing function (mean value calculation). Using this function it is possible to weigh domestic or small animals exactly (min. load 1% of the max. one), although they do not stand quiet on the weighing pan.

There is no average value calculation in the event of too much movement (heavy display oscillation).

Determination of the number of pieces
Before it is possible to determine the number of pieces by means of the scales, it is necessary to specify the average piece weight (unit weight), the so-called reference value. In order to do it, one shall place the specific number of pieces being counted up. By means of the scales, the total mass shall be determined which then will be divided by the number of pieces (the so-called reference pieces). Afterwards, based on the calculated average piece weight, counting up shall be carried out.

The greater the number of reference pieces, the higher the accuracy of counting up.

Navigation in the menu

  • Press and at the same time in weighing mode. [UF 1] is displayed.
  • Press as often as necessary until the required function is displayed.
  • Confirm selected function by . The current setting will be displayed. Select the desired parameter with . Return to menu by .
  • Press  to exit the menu. The balance returns automatically into weighing mode.

Menu overview

Factory settings are marked by *.

Servicing, maintenance, disposal

  • Cleaning
    • Before cleaning, disconnect the appliance from the operating voltage.
    • Please do not use aggressive cleaning agents (solvents or similar agents), but a cloth dampened with mild soap suds. Take care that the device is not penetrated by fluids and polish it with a dry soft cloth.
    • Loose residue sample/powder can be removed carefully with a brush or manual vacuum cleaner.
    • Spilled weighing goods must be removed immediately.
  • Servicing, maintenance
    • The appliance may only be opened by trained service technicians who are authorized by KERN.
    • Before opening, disconnect from power supply.
  • Disposal
    Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.

Error messages, troubleshooting guide

Error message Function
hhhhhh Overload
LLLLLL Minimum weight under min. value

In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning.

Help:

Fault Possible cause

The displayed weight does not glow.

|

·        The balance is not switched on.

 | ·        The mains supply connection has been interrupted (mains cable not plugged in/faulty).
 | ·        Power supply interrupted.
The displayed weight is permanently changing| ·        Draught/air movement
·        Table/floor vibrations
 | ·        The weighing pan is in contact with foreign matter.

·        Electromagnetic fields / static charging (choose different location/switch off interfering device if possible)

The weighing value is obviously wrong| ·        The display of the balance is not at zero
·        Adjustment is no longer correct.
 | ·        The balance is on an uneven surface.
 | ·        Great fluctuations in temperature.

·        Electromagnetic fields / static charging (choose a different location/switch off

the interfering device if possible)

Should other error messages occur, switch balance off and then on again. If the error message remains inform the manufacturer

Declaration of conformity
The current EC/EU Conformity declaration can be found online in: www.kern- sohn.com/ce

Ziegelei 1 D-72336 Balingen

FAQ

Q: How do I change the weighing units on the scale?
A: To change the weighing units, press the designated button on the display unit. Refer to the user manual for specific instructions based on your model.

Q: What should I do if the scale is not stabilizing correctly?
A: Ensure that the scale is placed on a stable surface and that there are no external factors affecting its accuracy. Recalibrate if needed following the instructions provided.