PEDROLLO BC 35-50 Submersible Pumps Owner’s Manual

August 2, 2024
pedrollo

PEDROLLO BC 35-50 Submersible Pumps

Specifications

  • Product: BC Submersible Pumps
  • Material: Stainless steel and cast iron
  • Impeller Type: Two-Channel
  • Application: Sewage, sludge mixed water, activated and putrid sludge drainage
  • Electric Motor: Three-phase with thermal protector
  • Power Cable Length: 10m
  • Voltage: 400V

Product Usage Instructions

  • Installation
    • The BC series pumps are designed for submersible use. Follow these steps for installation:
    • Ensure the power cable length is appropriate for your setup.
    • Select a suitable location for submersion considering the minimum immersion requirement.
    • Connect the pump to the power source following electrical safety guidelines.
  • Usage
    • To effectively use the BC submersible pumps, consider the following:
    • Operate the pump by the specified voltage requirements.
    • Avoid running the pump dry to prevent damage.
    • Maintain a clean environment around the pump to ensure optimal performance.

FAQs

  • Q: What should I do if the pump overheats?
    • A: The pump is equipped with a thermal protector that activates in case of overheating. Allow the pump to cool down before restarting.
  • Q: Can the BC pumps handle different types of sludge?
    • A: Yes, the BC pumps are designed to handle sewage, sludge mixed water, and activated and putrid sludge, making them versatile for various applications.

PERFORMANCE RANGE

  • Flow rate up to 2300 l/min (138 m3/h)
  • Head up to 31 m

INSTALLATION AND USE

  • The BC series is constructed from thick stainless steel and cast iron, offering exceptional robustness, abrasion resistance, and durability.
  • Equipped with TWO-CHANNEL impellers, the pumps are designed to drain sewage, sludge mixed water, and activated and putrid sludge.
  • They are suitable for a wide range of applications, including sewers, tunnels, excavations, canals, and underground parking facilities.

ELECTRIC MOTOR

  • The electric motor is safeguarded by a special three-phase thermal protector, situated within the motor, which activates in case of overheating or abnormal power consumption.

INCLUDES

  • Power cable length 10 m

APPLICATION LIMITS

  • Depth below water level up to 10 m (with an appropriately sized power cable)
  • Liquid temperature up to +40 °C
  • Suspended solids transfer:
    • up to Ø 35 mm for BC/35
    • up to Ø 50 mm for BC/50
  • Minimum immersion for continuous service: 500 mm

AVAILABLE UPON REQUEST

  • Different voltage requirements 60 Hz frequency

PATENTS – TRADE MARKS – MODELS

  • Registered Community Model No. 003863158-0001

CURVES AND PERFORMANCE DATA 50 Hz

TYPE

Three- phase

| POWER (P2)| Q| m³/h| 0| 18| 30| 45| 60| 75| 90| 108| 126| 138
---|---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 300| 500| 750| 1000| 1250| 1500| 1800| 2100| 2300
BC 40/50| 3| 4|

H metres

| 16.5| 16| 14.8| 13| 11| 9| 6.8| 4.5| |
BC 55/50| 4| 5.5| 21.5| 20| 19| 17.5| 15.6| 13.5| 11.3| 8.7| 6|
BC 75/50| 5.5| 7.5| 26.5| 24.5| 23.2| 21.5| 19.6| 17.5| 15.3| 12.4| 9.4| 7.5

Technical data

ABSORPTION

TYPE

Three- phase

| VOLTAGE

400 V

---|---
BC 40/35| 6.2 A
BC 55/35| 8.3 A
BC 75/35| 13.5 A
TYPE

Three- phase

| VOLTAGE

400 V

---|---
BC 40/50| 7.0 A
BC 55/50| 9.0 A
BC 75/50| 13.5 A

DIMENSIONS AND WEIGHT

Typical installation

PORT FLANGE

TYPE

Three- phase

| FLANGE

DN

| F| K

mm

| D

mm

| HOLES
---|---|---|---|---|---
N°| Ø mm)
__**BC 40/35 __**

BC 55/35 BC 75/35

| 65

(PN10)

| ****

2½”

| ****

145

| ****

185

| ****

4

| ****

18

__**BC 40/50 __**

BC 55/50 BC 75/50

| 80

(PN10)

| ****

3″

| ****

160

| ****

200

| ****

8

| ****

18

PALLET CAPACITY

TYPE

Three- phase

| NO. OF PUMPS
---|---
BC 40/35| 12
BC 55/35| 12
BC 75/35| 12
BC 40/50| 12
BC 55/50| 12
BC 75/50| 12

MATERIALS AND COMPONENTS

SEWAGE LIFTING SYSTEM VX – BC

VERSION WITH HORIZONTAL DELIVERY AND ¾” GUIDE PIPES

For VX /50 Code ASSPVX50 DN 2

Kit consisting of:

VERSION WITH VERTICAL DELIVERY AND ¾” GUIDE PIPES

For VX /50 Code ASSPVX503V DN 2½”
For VX /65, BC /35 Code ASSPVX653V DN 3″
For BC /50 Code ASSVXCF071V

VERSION WITH VERTICAL DELIVERY AND 2″ GUIDE TUBES

For VX /50 Code ASSPVX50V DN 3″
For VX /65, BC /35 Code ASSPVX65V
For VX /80, BC /50 Code ASSVXCF0705V

Kit consisting of:

ACCESSORIES

ACCESSORIES AVAILABLE FOR ORDER RUNNING GUIDE

For VX /50 with Ø ¾” guide tubes Code ASSFL009
For VX /65, BC /35 with Ø ¾” guide tubes Code ASSFL010
For BC /50 with Ø ¾” guide tubes Code ASSFL0018
For VX /50 with Ø 2″ guide tubes Code ASSFL050
For VX /65, BC /35 with Ø 2″ guide tubes Code ASSFL065
For VX /80, BC /50 with Ø 2″ guide tubes Code ASSFL072

Complete with screws and seals

INTERMEDIATE GUIDE TUBE SUPPORT

For Ø ¾” guide tubes Code 859SV340INTFA
For guide tubes Ø 2″ Code 859SV349INTFA

For reasons of stability, an intermediate support should be interposed:

  • every 2 metres with ¾” guide pipes (mandatory)
  • every 3 meters with 2″ guide tubes (recommended)

GUIDE TUBE (AISI 304 stainless steel)

2 metres Ø ¾” guide tube Code 54SARTG0052F
3 metres Ø ¾” guide tube Code 54SARTG0053F
6 metres Ø ¾” guide tube Code 54SARTG0056F
3 metres Ø 2″ guide tube Code 54SARTG0063F
6 metres guide tube Ø 2″ Code 54SARTG0066F

DIMENSIONS

DIMENSIONS (HORIZONTAL delivery version)

DIMENSIONS (Version with VERTICAL delivery)

Version with ¾” guide tubes

TYPE| Solid bodies mm| PORT

DN

| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| Øg| Øm| Øn| Ør
VX /50| Ø 50 mm| 2½”| 211| ****

61

| 52| 125| 165| 506| 28| 164| 216| 120| 72| 62| 3| ****

50

| ****

¾”

| ****

14

| ****

11

| ****

18

VX /65| Ø 65 mm| 3″| 213| ****

69

| ****

150

| ****

190

| 537| 48| ****

216

| ****

280

| ****

130

| ****

112

| ****

84

| ****

15

BC /35| Ø 35 mm| 231| 550| 69
BC /50| Ø 50 mm| 222| 553| 19

Version with 2″ guide tubes

TYPE| Solid bodies

mm

| PORT

DN

| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| i6| Øg| Øm| Øn| Ør
VX /50| Ø 50 mm| ****

3″

| 319| ****


86

| ****


95

| ****


160

| ****


200

| 706| 107| ****


264

| ****


392

| ****


250

| ****


150

| ****


34

| ****


| ****


80

| ****


186

| ****


2″

| ****


22

| ****


13.5

| ****


18

VX /65| Ø 65 mm| 697| 86
VX /80| Ø 80 mm| 328| 714| 57
BC /35| Ø 35 mm| 319| 710| 107
BC /50| Ø 50 mm| 328| 714| 57

Advanced design and high-quality materials assure long-term performance and reliability.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals