PEDROLLO BC 35-50 Submersible Pumps
Specifications
- Product: BC Submersible Pumps
- Material: Stainless steel and cast iron
- Impeller Type: Two-Channel
- Application: Sewage, sludge mixed water, activated and putrid sludge drainage
- Electric Motor: Three-phase with thermal protector
- Power Cable Length: 10m
- Voltage: 400V
Product Usage Instructions
- Installation
- The BC series pumps are designed for submersible use. Follow these steps for installation:
- Ensure the power cable length is appropriate for your setup.
- Select a suitable location for submersion considering the minimum immersion requirement.
- Connect the pump to the power source following electrical safety guidelines.
- Usage
- To effectively use the BC submersible pumps, consider the following:
- Operate the pump by the specified voltage requirements.
- Avoid running the pump dry to prevent damage.
- Maintain a clean environment around the pump to ensure optimal performance.
FAQs
- Q: What should I do if the pump overheats?
- A: The pump is equipped with a thermal protector that activates in case of overheating. Allow the pump to cool down before restarting.
- Q: Can the BC pumps handle different types of sludge?
- A: Yes, the BC pumps are designed to handle sewage, sludge mixed water, and activated and putrid sludge, making them versatile for various applications.
PERFORMANCE RANGE
- Flow rate up to 2300 l/min (138 m3/h)
- Head up to 31 m
INSTALLATION AND USE
- The BC series is constructed from thick stainless steel and cast iron, offering exceptional robustness, abrasion resistance, and durability.
- Equipped with TWO-CHANNEL impellers, the pumps are designed to drain sewage, sludge mixed water, and activated and putrid sludge.
- They are suitable for a wide range of applications, including sewers, tunnels, excavations, canals, and underground parking facilities.
ELECTRIC MOTOR
- The electric motor is safeguarded by a special three-phase thermal protector, situated within the motor, which activates in case of overheating or abnormal power consumption.
INCLUDES
- Power cable length 10 m
APPLICATION LIMITS
- Depth below water level up to 10 m (with an appropriately sized power cable)
- Liquid temperature up to +40 °C
- Suspended solids transfer:
- up to Ø 35 mm for BC/35
- up to Ø 50 mm for BC/50
- Minimum immersion for continuous service: 500 mm
AVAILABLE UPON REQUEST
- Different voltage requirements 60 Hz frequency
PATENTS – TRADE MARKS – MODELS
- Registered Community Model No. 003863158-0001
CURVES AND PERFORMANCE DATA 50 Hz
TYPE
Three- phase
| POWER (P2)| Q| m³/h| 0| 18| 30| 45| 60| 75| 90| 108| 126| 138
---|---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 300| 500| 750| 1000|
1250| 1500| 1800| 2100| 2300
BC 40/50| 3| 4|
H metres
| 16.5| 16| 14.8| 13| 11| 9| 6.8| 4.5| |
BC 55/50| 4| 5.5| 21.5| 20| 19| 17.5| 15.6| 13.5| 11.3| 8.7| 6|
BC 75/50| 5.5| 7.5| 26.5| 24.5| 23.2| 21.5| 19.6| 17.5| 15.3| 12.4|
9.4| 7.5
Technical data
ABSORPTION
TYPE
Three- phase
| VOLTAGE
400 V
---|---
BC 40/35| 6.2 A
BC 55/35| 8.3 A
BC 75/35| 13.5 A
TYPE
Three- phase
| VOLTAGE
400 V
---|---
BC 40/50| 7.0 A
BC 55/50| 9.0 A
BC 75/50| 13.5 A
DIMENSIONS AND WEIGHT
Typical installation
PORT FLANGE
TYPE
Three- phase
| FLANGE
DN
| F| K
mm
| D
mm
| HOLES
---|---|---|---|---|---
N°| Ø mm)
__**BC 40/35 __**
BC 55/35 BC 75/35
| 65
(PN10)
| ****
2½”
| ****
145
| ****
185
| ****
4
| ****
18
__**BC 40/50 __**
BC 55/50 BC 75/50
| 80
(PN10)
| ****
3″
| ****
160
| ****
200
| ****
8
| ****
18
PALLET CAPACITY
TYPE
Three- phase
| NO. OF PUMPS
---|---
BC 40/35| 12
BC 55/35| 12
BC 75/35| 12
BC 40/50| 12
BC 55/50| 12
BC 75/50| 12
MATERIALS AND COMPONENTS
SEWAGE LIFTING SYSTEM VX – BC
VERSION WITH HORIZONTAL DELIVERY AND ¾” GUIDE PIPES
For VX /50 | Code ASSPVX50 | DN 2 |
---|
Kit consisting of:
VERSION WITH VERTICAL DELIVERY AND ¾” GUIDE PIPES
For VX /50 | Code ASSPVX503V | DN 2½” |
---|---|---|
For VX /65, BC /35 | Code ASSPVX653V | DN 3″ |
For BC /50 | Code ASSVXCF071V |
VERSION WITH VERTICAL DELIVERY AND 2″ GUIDE TUBES
For VX /50 | Code ASSPVX50V | DN 3″ |
---|---|---|
For VX /65, BC /35 | Code ASSPVX65V | |
For VX /80, BC /50 | Code ASSVXCF0705V |
Kit consisting of:
ACCESSORIES
ACCESSORIES AVAILABLE FOR ORDER RUNNING GUIDE
※ For VX /50 with Ø ¾” guide tubes | Code ASSFL009 |
---|---|
※ For VX /65, BC /35 with Ø ¾” guide tubes | Code ASSFL010 |
※ For BC /50 with Ø ¾” guide tubes | Code ASSFL0018 |
※ For VX /50 with Ø 2″ guide tubes | Code ASSFL050 |
※ For VX /65, BC /35 with Ø 2″ guide tubes | Code ASSFL065 |
※ For VX /80, BC /50 with Ø 2″ guide tubes | Code ASSFL072 |
Complete with screws and seals
INTERMEDIATE GUIDE TUBE SUPPORT
※ For Ø ¾” guide tubes | Code 859SV340INTFA |
---|---|
※ For guide tubes Ø 2″ | Code 859SV349INTFA |
For reasons of stability, an intermediate support should be interposed:
- every 2 metres with ¾” guide pipes (mandatory)
- every 3 meters with 2″ guide tubes (recommended)
GUIDE TUBE (AISI 304 stainless steel)
※ 2 metres Ø ¾” guide tube | Code 54SARTG0052F |
---|---|
※ 3 metres Ø ¾” guide tube | Code 54SARTG0053F |
※ 6 metres Ø ¾” guide tube | Code 54SARTG0056F |
※ 3 metres Ø 2″ guide tube | Code 54SARTG0063F |
※ 6 metres guide tube Ø 2″ | Code 54SARTG0066F |
DIMENSIONS
DIMENSIONS (HORIZONTAL delivery version)
DIMENSIONS (Version with VERTICAL delivery)
Version with ¾” guide tubes
TYPE| Solid bodies mm| PORT
DN
| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| Øg| Øm| Øn| Ør
VX /50| Ø 50 mm| 2½”| 211| ****
61
| 52| 125| 165| 506| 28| 164| 216| 120| 72| 62| 3| ****
50
| ****
¾”
| ****
14
| ****
11
| ****
18
VX /65| Ø 65 mm| 3″| 213| ****
69
| ****
150
| ****
190
| 537| 48| ****
216
| ****
280
| ****
130
| ****
112
| ****
84
| ****
15
BC /35| Ø 35 mm| 231| 550| 69
BC /50| Ø 50 mm| 222| 553| 19
Version with 2″ guide tubes
TYPE| Solid bodies
mm
| PORT
DN
| DIMENSIONS mm
---|---|---|---
a| b| c| d| e| p| h1| h2| h3| i1| i2| i3| i4| i5| i6| Øg| Øm| Øn| Ør
VX /50| Ø 50 mm| ****
3″
| 319| ****
86
| ****
95
| ****
160
| ****
200
| 706| 107| ****
264
| ****
392
| ****
250
| ****
150
| ****
34
| ****
–
| ****
80
| ****
186
| ****
2″
| ****
22
| ****
13.5
| ****
18
VX /65| Ø 65 mm| 697| 86
VX /80| Ø 80 mm| 328| 714| 57
BC /35| Ø 35 mm| 319| 710| 107
BC /50| Ø 50 mm| 328| 714| 57