bryant 820SB Efficiency AFUE Gas Furnace Owner’s Manual

July 31, 2024
bryant

820SB Efficiency AFUE Gas Furnace

“`html

Specifications

  • Model: 820SB/821SB
  • Series: Preferred SeriesTM
  • AFUE: 80%
  • Motor: Variable 25-Speed ECM
  • Poise: 4-Way Multipoise
  • Gas Type: Non-Condensing
  • Technology: InteliSenseTM

Product Usage Instructions

Performance Features:

  • Continuous Fan speed adjustable from thermostat
  • Reflective sight glass for easy monitoring
  • Non-volatile fault code memory for troubleshooting
  • Self-test feature for system diagnostics

Installation Flexibility:

  • This furnace is not suitable for use in mobile homes, trailers,
    or recreational vehicles

  • For proper installation, refer to the Installation
    Instructions

Certification and Warranty:

  • 10-year parts limited warranty with timely registration*
  • AHRI Certified TM Mark indicates manufacturer participation in
    the program

*Equipment must be registered within 90 days of original
installation.

FAQ

Q: Can this furnace be used in mobile homes?

A: No, this furnace is not designed for use in mobile homes,
trailers, or recreational vehicles.

Q: What is the warranty coverage for this product?

A: The product comes with a 10-year parts limited warranty with
timely registration.

Q: What is the efficiency rating of this furnace?

A: The AFUE (Annual Fuel Utilization Efficiency) rating of this
furnace is 80%.

Q: How can I adjust the fan speed of the furnace?

A: The fan speed can be adjusted from the thermostat
settings.

“`

820SB/821SB Preferred SeriesTM 80% AFUE, Non-Communicating, Single Stage, Variable 25-Speed ECM Motor, 4-Way Multipoise, Non-Condensing Gas Furnace with InteliSenseTM Technology

Product Data

A10252
Representative drawing only. Some product models may vary.
! WARNING
This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. Such use could result in property damage and/or death.
The 820SB/821SB 4-way Multipoise Gas Furnaces feature Bryant’s QuieTechTM noise reduction system for quiet induced draft operation. Applications are easy with our 4-way multipoise design, through-the -furnace downflow venting, 13 different venting options, and easy service access. An inner blower door is provided for tighter sealing in sensitive applications. The 820SB/821SB furnaces are factory shipped for use with natural gas and convertible to propane with approved accessory kit. The 821SB – Low NOx units are designed for California installations and meet 40 ng/J NOx emission limits. Can be installed in air quality management districts with a 40 ng/J NOx emissions limit.

PERFORMANCE
· Single Stage gas valve · Variable 25-speed, constant torque (VCT) ECM blower motor · QuieTechTM noise reduction system · Microprocessor based “smart” control center Fan on PlusTM –
Continuous Fan speed adjustable from thermostat
· Enhanced diagnostics with easy to read 3 digit display for faults and
status and reflective sight glass, non-volatile fault code memory, and
self test feature
· Adjustable heating air temperature rise · Adjustable cooling airflow · Perfect LightTM Igniter
· Patented blocked vent safeguard to ensure proper furnace venting
· Inner blower door for tighter sealing
INSTALLATION FLEXIBILITY
· 4-way Multipoise furnace, 13 vent applications · On-board NFC antenna makes setup a tap away when using the
Bryant service technician app. · HYBRIDHEAT® Dual Fuel System compatible · All models are chimney friendly when used with accessory vent kit
APPLICATIONS
· Compact design – only 33-1/3 in. (847 mm) tall · Propane convertible with gas conversion accessory · Convenient Air Purifier and Humidifier connections
CERTIFICATON
· Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
· Residential installations eligible for consumer financing through the Retail Credit Program
LIMITED WARRANTY
· Default 5-year parts limited warranty · 20-year heat exchanger limited warranty
10-year parts limited warranty with timely registration Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Applies to original purchaser/homeowner and not available to subsequent owners except in jurisdictions where laws dictate otherwise.

Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org .

A210064

This furnace is InteliSense capable when used with an ecobee for Bryant smart thermostat with InteliSense technology. InteliSense technology allows for the collection of performance data to be sent to the cloud. Utilizing Bryant’s digital tools, dealers can gather system settings and equipment data, with homeowner opt-in, to provide quicker and more efficient service.

820SB/821SB: Product Data

UNIT PERFORMANCE DATA

Unit Size 36045V14 36070V14 48070V17 48090V17 60090V21 66110V21 66135V24

Heating Input 44,000 66,000 66,000 88,000 88,000 110,000 132,000

Efficiency AFUE 80% 80% 80% 80% 80% 80% 80%

Cooling Capacity CFM range @ .5 in.
w.c. (125 Pa) 185-1345 220-1340 245-1680 340-1480 330-2285 375-2345 340-2330

DIMENSIONAL DATA

Operating Dimensions Height x Width x Depth
in (mm) 33-1/3 x 14-3/16 x 29 (847 x 360x 737) 33-1/3 x 14-3/16 x 29 (847 x 360x 737) 33-1/3 x 17-1/2 x 29 (847 x 445 x 737) 33-1/3 x 17-1/2 x 29 (847 x 445 x 737)
33-1/3 x 21 x 29 (847 x 533 x 737) 33-1/3 x 21 x 29 (847 x 533 x 737) 33-1/3 x 24-1/2 x 29 (847 x 622x 737)

Shipping Weight lbs(kg) 111 (50.3) 118 (53.5) 129 (58.5) 134 (60.8) 149 (67.6) 155 (70.3) 170 (77.1)

NOTE: ALL DIMENSIONS IN INCH (MM)

U.S. ECCN: Not Subject to Regulation (N.S.R.)

SD5669-4 REV. –
A210785

Unit Size 36045V14 36070V14 48070V17 48090V17 60090V21 66110V21
66135V24

A
CABINET WIDTH
14-3/16 (360) 14-3/16 (360) 17-1/2 (445) 17-1/2 (445)
21 (533) 21 (533) 24-1/2 (622)

B
OUTLET WIDTH
12-9/16 (319) 12-9/16 (319) 15-7/8 (403) 15-7/8 (403) 19-3/8 (492) 19-3/8 (492) 22-7/8 (581

Dimensions
C TOP AND BOTTOM FLUE COLLAR 9-5/16 (237) 9-5/16 (237) 11-9/16 (294) 11-9/16 (294) 13-5/16 (338) 13-5/16 (338)
15-1/16 (383)

D BOTTOM INLET WIDTH
12-11/16 (322) 12-11/16 (322)
16 (406) 16 (406) 19-1/2 (495) 19-1/2 (495)
23 (584)

VENT CONNECTION
SIZE 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102)
4 (102)*

SHIP WT. LB. (KG)
111 (50.3) 118 (53.5) 129 (58.5) 134 (60.8) 149 (67.6) 155 (70.3)
170 (77.1)

*. 135 size furnaces require a 5 or 6-in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2

820SB/821SB: Product Data
MODEL NUMBER NOMENCLATURE

1 Heat Exchanger
9
|

2
Tier/NOx 8
|

3
AFUE/NOx 7
|

4
Heating Stages M
|

8 = 80% 9 = 90+%

0 = Base 1 = Legacy Line 2 = Preferred 3 = Ultra Low Nox 8 = Evolution

0 = 80% 1 = 80% Low Nox —2 = 92% 5 = 95% 6 = 96% 7 = 97% 8 = 98%

M = Modulating S = Single Stage T = Two-Stage

5 Major Series
B
|

6, 7 Cooling Capacity (CFM)
42
|

8 – 10
Heat Input 060
|

24 = 800 CFM

30 = 1000 CFM

026 = 26,000 BTU/h

A

36 = 1200 CFM

040 = 40,000 BTU/h

B

42 = 1400 CFM

060 = 60,000 BTU/h

C

48 = 1600 CFM

D

60 = 2000 CFM

66 = 2200 CFM

11
Motor Type C
|
C = Comm. VariableSpeed Constant Airflow (VCA) ECM
E= Fixed-Speeds Constant Torque (FCT) ECM
V = Variable-Speed Constant Torque (VCT) ECM

12 – 13
Width 17
|

14 Voltage (1-phase)
A
|

14 = 14.2″ 17 = 17.5″ 21 = 21.0″ 24 = 24.5″

A = 110V/60Hz B = 230V/50Hz

15
Un-used –

16 Minor Series
A

|

|

A

B

C

A190404

FURNACE COMPONENTS
INDUCER MOTOR ASSEMBLY
PRESSURE SWITCH
FLUE COLLECTOR BOX
GAS VALVE

VENT ELBOW
MAIN LIMIT SWITCH (BEHIND GAS VALVE)
BLOCKED VENT SWITCH
FLAME SENSOR

CLEARANCES

MANUAL RESET LIMIT SWITCHES
HOT SURFACE IGNITOR
BLOWER DOOR SAFETY
SWITCH
FURNACE CONTROL
BOARD

GAS MANIFOLD
GAS BURNER
BLOWER AND MOTOR

A190086
NOTE: The furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit.

A220231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3

820SB/821SB: Product Data

SPECIFICATIONS

UNIT SIZE

HEATING AND CAPACITY AND EFFICIENCY

All Standard

All Low NOx

Input BTUh*

Upflow All Low NOx

Downflow/

Horizontal

All Standard

All Low NOx

Output Capacity (BTUh)

Upflow All Low NOx

Downflow/

Horizontal

Certified Temperature Rise Range – °F (°C) AFUE

AIRFLOW CAPACITY AND BLOWER DATA

Rated Certified External Static

Heating

Pressure

Cooling

Airflow CFM @ Rated ESP (CFM)

Heating Cooling

Cooling Capacity (tons)

400 CFM/ton 350 CFM/ton

Direct Drive Motor Type

Direct Drive Motor HP

Motor Full Load Amps

Heating Blower Control (Htg Off-Delay)

Cooling Blower Control (Time Delay Relay)

Blower Wheel Diameter x Width – In. (mm)

Air Filtration System

Filter used for Certified Watt Data

ELECTRICAL DATA

Unit Volts-Hertz-Phase

Operating Voltage Range

Min-Max

Maximum Unit Amps

Unit Ampacity

Maximum Wire Length

Measure 1 way in Ft

Feet

(M)

Meters

Minimum Wire Size

AWG

Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended)

Amps

Transformer Capacity (24 VAC output)

External Control Power Available

Heating Cooling

GAS CONTROLS

Burners

Gas Connection Size

Gas Valve (Redundant)

Mfr

Min. inlet pressure

(in.w.c.)

Max. inlet pressure

(in.w.c.)

Ignition Device

Factory installed orifice

CONNECTIONS

Communication System

Thermostat Connections

Accessory Connections

36045V14

36070V14

48070V17

48090V17

44,000

66,000

66,000

88,000

42,000

63,000

63,000

84,000

36,000

54,000

54,000

71,000

34,000

51,000

51,000

68,000

30 – 60 (17 – 33) 30 – 60 (17 – 33)

80

80

25 – 55 (14 – 31) 80

40 – 70 (22 – 39) 80

0.1 0.5 770 185-1345 3 3.5
1/2 6.7
10 x 6

0.12

0.12

0.5

0.5

1090

1300

220-1340

245-1680

3

4

3.5

4.5

Electronically Commutated Motor (ECM)

1/2

3/4

6.7

8.8

Adjustable: 90, 120, 150, 180 seconds

90 seconds

10 x 6

11 x 8

Field Supplied Filter

325531-40**

0.15 0.5 1220 340-1480 3.5 4
1/2 6.7
10 x 8

115-60-1

104-127

7.9

7.9

10.4

8.2

10.7

10.7

13.8

11

34

34

26

34

10.6

10.6

8.2

10.3

14

14

14

14

15

15

15

15

40VA 12VA 35VA

2

3

3

4

1/2in. NPT

WhiteRodgersTM

4.5 (Natural Gas)

13.6 (Natural Gas)

Silicon Nitride

43

43

43

43

InteliSenseTM G, C, W, Y/Y2, Y1, R, DHUM EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y/Y2); 2-STG AC (via Y/Y2 and Y1)

*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4

820SB/821SB: Product Data

UNIT SIZE

HEATING AND CAPACITY AND EFFICIENCY

All Standard

All Low NOx

Input BTUh*

Upflow All Low NOx

Downflow/

Horizontal

All Standard

All Low NOx

Output Capacity (BTUh)

Upflow All Low NOx

Downflow/

Horizontal

Certified Temperature Rise Range – °F (°C) AFUE

AIRFLOW CAPACITY AND BLOWER DATA

Rated Certified External Static

Heating

Pressure

Cooling

Airflow CFM @ Rated ESP (CFM)

Heating Cooling

Cooling Capacity (tons)

400 CFM/ton 350 CFM/ton

Direct Drive Motor Type

Direct Drive Motor HP

Motor Full Load Amps

Heating Blower Control (Htg Off-Delay)

Cooling Blower Control (Time Delay Relay)

Blower Wheel Diameter x Width – In. (mm)

Air Filtration System

Filter used for Certified Watt Data

ELECTRICAL DATA

Unit Volts-Hertz-Phase

Operating Voltage Range

Min-Max

Maximum Unit Amps

Unit Ampacity

Maximum Wire Length

Measure 1 way in Ft

Feet

(M)

Meters

Minimum Wire Size

AWG

Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended)

Amps

Transformer Capacity (24 VAC output)

External Control Power Available

Heating Cooling

GAS CONTROLS

Burners

Gas Connection Size

Gas Valve (Redundant)

Mfr

Min. inlet pressure

(in.w.c.)

Max. inlet pressure

(in.w.c.)

Ignition Device

Factory installed orifice

CONNECTIONS

Communication System

Thermostat Connections

Accessory Connections

60090V21

66110V21

66135V24

88,000

110,000

132,000

84,000

105,000

126,000

71,000

90,000

107,000

68,000

85,000

102,000

25 – 55 (14 – 31) 80

30 – 60 (17 – 33) 80

40 – 70 (22 – 39) 80

0.15 0.5 1690 330-2285 5 5.5
1 11.5
11 x 11

0.2 0.5 1880 375-2345 5 5.5 Electronically Commutated Motor (ECM) 1 11.5 Adjustable: 90, 120, 150, 180 seconds 90 seconds 11 x 11 Field Supplied Filter 325531-40**

0.2 0.5 1930 340-2330 5 5.5
1 11.5
11 x 11

115-60-1

104-127

13.9

14.4

18.1

18.6

14.4 18.6

31

30

30

9.6

9.4

9.4

12

12

12

20

20

20

40VA 12VA 35VA

4

5

6

1/2in. NPT

WhiteRodgersTM

4.5 (Natural Gas)

13.6 (Natural Gas)

Silicon Nitride

43

43

43

InteliSenseTM G, C, W, Y/Y2, Y1, R, DHUM EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y/Y2); 2-STG AC (via Y/Y2 and Y1)

*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available.

ICS = Isolated Combustion System

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5

820SB/821SB: Product Data

AIR DELIVERY (WITH FILTER)

Table 1 ­ Air Delivery – CFM (with filter)*

Unit Size 36045V14
36070V14

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Default Setting Cont. Fan Heating
Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling

0.1 455 500 565 600 655 720 770 795 825 880 910 935 985 1015 1045 1075 1110 1160 1190 1220 1250 1280 1325 1400 1485 480 525 565 620 650 700 715 760 815 870 920 980 1035 1070 1100 1130 1160 1190 1220 1250 1285 1315 1345 1385 1470

0.2 390 440 510 550 605 675 725 755 785 840 875 900 950 980 1010 1045 1080 1130 1160 1190 1225 1255 1295 1375 1460 420 470 510 570 605 655 675 720 780 830 885 950 1005 1040 1070 1100 1130 1160 1190 1225 1255 1290 1320 1360 1445

0.3 325 380 450 495 555 630 680 715 745 800 835 865 915 950 980 1015 1045 1100 1130 1160 1195 1225 1270 1350 1420 355 410 455 520 560 615 630 680 740 795 850 915 975 1010 1040 1070 1105 1135 1165 1200 1230 1265 1295 1335 1415

External Static Pressure (in. w.c.)

0.4

0.5

0.6

0.7

0.8

255 185 115

320 255 185 120

395 340 285 220

145

440 390 340 285

225

505 455 410 365

310

585 535 490 450

405

640 595 550 505

465

670 630 585 540

500

705 660 620 575

535

765 725 685 645

605

800 760 725 685

645

830 795 755 720

685

885 850 815 780

745

920 885 850 820

785

945 915 885 850

815

980 950 920 890

855

1015 985 955 925

895

1070 1040 1015 985

955

1100 1075 1045 1015 990

1135 1105 1075 1050 1020

1165 1140 1115 1085 1060

1200 1175 1145 1120 1095

1245 1220 1190 1165 1140

1325 1300 1275 1250 1225

1380 1345 1305 1260 1225

285 220 160 115

340 280 225 170

395 340 275 225

175

465 410 360 300

250

510 460 405 355

300

565 520 470 420

375

585 540 495 440

395

640 595 550 505

455

700 660 620 580

535

760 725 685 645

605

815 780 745 710

675

885 850 815 780

745

940 910 880 850

815

980 945 915 885

855

1010 980 950 920

890

1045 1015 985 955

925

1075 1045 1020 990

960

1105 1080 1050 1025 995

1135 1110 1080 1055 1025

1170 1145 1115 1090 1065

1205 1180 1150 1125 1100

1235 1210 1185 1160 1135

1270 1245 1215 1190 1165

1310 1285 1260 1235 1215

1375 1340 1300 1260 1225

0.9 –
145 255 360 425 460 500 565 605 645 710 750 785 825 860 920 960 990 1030 1065 1115 1180 1180
135 205 250 325 345 410 490 565 635 710 780 820 860 895 930 965 1000 1035 1070 1110 1140 1180 1180

1 190 310 380 425 460 530 570 610 675 715 750 790 830 890 930 960 1000 1040 1085 1095 1100 160 210 275 300 365 450 525 595 675 750 790 830 865 900 940 970 1010 1045 1085 1115 1140 1140

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6

820SB/821SB: Product Data

Unit Size 48070V17
48090V17

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Table 1 ­ Air Delivery – CFM (with filter)* (Continued)

Default Setting Cont. Fan
Heating Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling

0.1 560 615 670 745 810 875 955 1025 1090 1170 1215 1260 1310 1345 1385 1420 1460 1495 1535 1575 1620 1655 1690 1750 1825 660 700 750 805 855 900 945 975 1015 1070 1130 1170 1200 1240 1260 1295 1325 1360 1395 1430 1460 1500 1535 1575 1615

0.2 480 540 600 680 750 815 900 970 1045 1125 1170 1220 1270 1305 1345 1380 1420 1460 1500 1540 1585 1620 1655 1720 1795 580 625 685 740 795 845 890 925 965 1020 1085 1125 1155 1200 1220 1255 1285 1325 1360 1390 1425 1465 1500 1540 1580

0.3 395 465 530 615 690 760 845 920 995 1080 1125 1175 1230 1265 1305 1345 1385 1425 1460 1505 1550 1585 1625 1690 1760 480 525 585 670 730 785 835 865 915 970 1040 1080 1115 1160 1180 1215 1250 1285 1320 1355 1390 1430 1465 1505 1545

External Static Pressure (in. w.c.)

0.4

0.5

0.6

0.7

0.8

315 245 165

385 320 255 175

460 385 325 265

190

550 485 415 360

305

630 570 505 445

395

705 645 590 530

470

795 740 685 630

580

870 825 775 725

675

945 900 855 805

760

1035 990 950 905

860

1080 1040 995 950

910

1135 1095 1055 1010 970

1190 1150 1110 1070 1030

1225 1190 1150 1110 1070

1265 1225 1185 1150 1110

1305 1270 1230 1195 1155

1345 1310 1275 1235 1205

1385 1350 1315 1280 1245

1425 1395 1355 1320 1290

1475 1440 1405 1370 1340

1515 1485 1450 1420 1390

1555 1525 1490 1460 1430

1595 1565 1535 1500 1475

1660 1630 1600 1570 1540

1720 1680 1635 1595 1555

410 340 265 210

150

455 395 320 255

205

520 460 395 325

270

580 520 465 405

335

640 580 520 465

405

695 635 580 525

470

770 685 630 575

530

810 725 665 615

565

860 775 715 665

615

920 865 785 730

680

990 945 865 805

755

1030 985 930 855

805

1070 1020 975 900

845

1115 1070 1025 980

905

1140 1095 1050 1005 935

1175 1130 1090 1045 980

1210 1170 1125 1085 1035

1245 1210 1165 1125 1085

1285 1245 1205 1165 1125

1320 1285 1245 1205 1165

1355 1320 1280 1245 1205

1395 1360 1320 1285 1245

1430 1400 1360 1325 1290

1475 1440 1405 1370 1335

1515 1480 1450 1410 1350

0.9 –
245 340 420 525 625 715 815 870 930 990 1035 1075 1120 1165 1210 1255 1305 1360 1400 1445 1500 1510
145 220 280 345 410 475 515 570 630 710 760 800 855 880 925 965 1015 1075 1125 1165 1210 1255 1285 1285

1 165 285 375 470 575 665 775 825 890 955 995 1040 1085 1135 1180 1225 1275 1330 1370 1420 1460 1470 165 235 295 355 415 460 520 590 665 710 755 810 840 880 920 960 1010 1060 1115 1170 1215 1225 1225

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7

820SB/821SB: Product Data

Unit Size 60090V21
66110V21

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Table 1 ­ Air Delivery – CFM (with filter)* (Continued)

Default Setting Cont. Fan
Heating/Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling

0.1 780 860 930 1030 1125 1210 1285 1385 1475 1565 1670 1720 1765 1815 1860 1915 1970 2020 2070 2120 2170 2220 2270 2355 2470 815 890 1000 1100 1190 1280 1385 1480 1575 1685 1785 1880 1935 1995 2010 2060 2095 2140 2190 2250 2305 2355 2400 2460 2515

0.2 660 740 820 930 1035 1125 1210 1310 1410 1500 1605 1660 1710 1760 1805 1865 1915 1965 2025 2075 2125 2175 2225 2315 2425 690 780 900 1005 1105 1195 1305 1405 1505 1620 1725 1825 1880 1940 1960 2005 2045 2090 2145 2205 2260 2305 2355 2420 2470

0.3 545 645 725 835 935 1035 1125 1235 1340 1435 1550 1605 1655 1705 1755 1815 1865 1920 1975 2030 2080 2130 2185 2275 2385 580 670 800 910 1015 1110 1225 1335 1435 1555 1660 1765 1825 1885 1905 1950 1990 2040 2095 2155 2215 2260 2315 2375 2430

External Static Pressure (in. w.c.)

0.4

0.5

0.6

0.7

0.8

440 330 210

535 440 340 220

625 530 440 350

230

755 655 570 485

400

860 785 690 610

530

955 880 805 725

645

1040 975 905 830

750

1150 1085 1020 955

885

1265 1190 1130 1065 1010

1365 1290 1230 1175 1115

1485 1415 1350 1295 1240

1540 1475 1410 1350 1300

1595 1530 1465 1405 1355

1650 1585 1525 1460 1410

1700 1640 1580 1515 1465

1760 1705 1645 1585 1530

1815 1760 1705 1645 1590

1870 1820 1765 1710 1650

1930 1880 1830 1775 1720

1985 1935 1885 1835 1785

2035 1990 1945 1895 1845

2090 2045 2000 1955 1910

2145 2100 2055 2015 1970

2240 2200 2160 2115 2075

2335 2285 2230 2175 2115

475 375 285 190

570 475 385 300

215

700 615 525 440

360

820 735 650 570

490

930 840 765 685

610

1025 945 865 795

725

1150 1070 995 920

860

1260 1190 1120 1045 975

1365 1295 1230 1165 1095

1485 1420 1360 1295 1230

1600 1535 1475 1415 1355

1705 1645 1590 1530 1470

1765 1710 1650 1595 1545

1825 1770 1715 1660 1605

1850 1790 1740 1685 1630

1900 1840 1790 1735 1685

1940 1885 1835 1780 1730

1990 1935 1885 1835 1790

2045 1995 1940 1895 1850

2105 2055 2010 1960 1915

2165 2120 2075 2030 1985

2220 2175 2130 2085 2040

2270 2230 2185 2145 2100

2335 2290 2250 2205 2150

2385 2345 2290 2230 2170

0.9 –
310 450 570 675 815 940 1060 1180 1245 1305 1360 1415 1480 1540 1605 1670 1730 1795 1860 1920 2020 2050
135 285 415 535 645 790 920 1030 1165 1300 1415 1490 1555 1580 1635 1680 1740 1805 1870 1940 2000 2060 2100 2110

1 185 370 495 610 745 875 995 1130 1195 1255 1310 1370 1435 1495 1560 1625 1685 1750 1815 1875 1965 1985 210 350 465 575 720 850 975 1105 1235 1365 1435 1505 1530 1585 1635 1695 1755 1830 1900 1960 2015 2045 2050

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8

820SB/821SB: Product Data

Table 1 ­ Air Delivery – CFM (with filter)* (Continued)

Unit Size

Airflow Setting

Default Setting

External Static Pressure (in. w.c.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1

Cont. Fan

805 675 575 445 340 230 115

2

875 765 660 555 440 340 230

120

3

950 840 740 650 540 440 435

290

175

125

4

1045 945 850 765 675 560 475

385

295

195

5

1135 1045 950 865 785 700 595

515

430

350

6

1220 1135 1045 960 885 810 725

630

550

475

7

1320 1245 1165 1080 1010 940 865

790

690

620

8

1415 1345 1270 1190 1120 1055 990

920

845

755

9

1535 1465 1395 1325 1250 1185 1125 1065

1000

930

10

1615 1555 1485 1420 1350 1285 1225 1170

1110

1050

11

Low Cooling

1715 1660 1600 1535 1470 1400 1345 1290

1235

1180

12

66135V24

13

1770 1710 1650 1590 1525 1460 1400 1815 1760 1700 1640 1580 1515 1455

1350 1405

1295 1355

1240 1300

14

1860 1805 1750 1690 1630 1570 1510 1455

1405

1360

15

1925 1870 1815 1760 1705 1645 1585 1530

1475

1430

16

Heating

1980 1930 1875 1820 1765 1705 1650 1595

1545

1495

17

2035 1980 1930 1875 1825 1770 1710 1655

1605

1560

18

2085 2035 1985 1935 1880 1825 1775 1720

1670

1625

19

2135 2090 2040 1990 1940 1885 1835 1785

1730

1685

20

2185 2140 2090 2040 1995 1945 1895 1845

1795

1750

21

2235 2190 2145 2095 2050 2000 1955 1905

1855

1810

22

High Cooling

2285 2240 2195 2150 2105 2060 2010 1965

1920

1875

23

2335 2290 2245 2200 2155 2115 2070 2025

1980

1935

24

2415 2370 2330 2285 2245 2205 2160 2115

2065

2010

25

2505 2460 2420 2380 2330 2275 2215 2155

2090

2020

NOTE:

1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in a factory – authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1-in. w.c. available external static pressure.
2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation. 3. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20″ x 25″ (508 x 635 mm) is required. 4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return 5. The – entry indicates unstable operating conditions

Table 2 ­ Default Airflow Settings

Default Airflow Settings*

Designated Airflow Settings

Unit Size

Heating

High Cooling

Low Cooling

Heating

Constant Fan

36045V14

7

23

13

(3 – 11)

(1 – 9)

36070V14

15

23

13

(10 – 19)

(1 – 9)

48070V17

13

25

14

(7 – 15)

(1 – 4)

48090V17

14

25

13

(8 – 21)

(1 – 10)

60090V21

12

23

12

(7 – 17)

(1 – 9)

66110V21

13

21

11

(8 – 18)

(1 – 9)

66135V24

16

22

11

(9 – 19)

(1 – 8)

*. Setting #1 is the default setting for Constant Fan

TYPICAL WIRING SCHEMATIC

FURNACE CONTROL BOARD

A200307
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9

A221520

820SB/821SB: Product Data
VENTING CONFIGURATIONS

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL RIGHT

A02068

SEE NOTES: 1, 2, 4, 7, 8, 9
HORIZONTAL RIGHT

A02069

SEE NOTES: 1, 2, 4, 7, 8, 9
UPFLOW

A02058

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL RIGHT

A02070

SEE NOTES: 1, 2, 4, 7, 8, 9
HORIZONTAL LEFT

A02064

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT

A02065

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
DOWNFLOW

A02061

SEE NOTES: 1, 2, 3, 4, 5, 7, 8, 9
DOWNFLOW

A02060

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT

A02067

SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10

A02066

820SB/821SB: Product Data UPFLOW
DOWNFLOW

A02059

Venting notes
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54.
2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in. (127 mm) vent connector required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4-in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, space approximately 180 apart.
9. Secure all other single wall vent connector joints with (3) corrosion- resistant screws spaced approximately 120 apart. Secure Type B vent connectors per vent connector manufacturer’s recommendations.

A02063

DOWNFLOW

A02062

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11

820SB/821SB: Product Data

ACCESSORIES

PART NO. ACG1425NCB ACG1625NCF ACG2025NCJ ACG2424NCL
325531-402 325531-403 325531-404 KGADA0101ALL KGADA0201ALL KGADA0301ALL KGARP0301B14
KGARP0301B17
KGARP0301B21
KGARP0301B24
KGACA02014FC
KGACA02015FC
KGAFE0112UPH KGAVE0101DNH KGASB0201ALL
KGBVG0101DFG
AGAGC8NPS01C

AGAGC8PNS01C* AGATWNDTE01C

DESCRIPTION External Filter Rack, 14-1/2 x 25″
External Filter Rack, 16 x 25″
External Filter Rack 20 x 25″
External Filter Rack 24-1/2 x 24″
Washable filter, 3/4″ x 16″ x 25″
Washable filter, 3/4″ x 21″ x 25″
Washable filter 3/4″ x 24″ x 25″
Coil Adapter Kits – No Offset Coil Adapter Kits – Single Offset Coil Adapter Kits – Double Offset
Return Air Base (Upflow Applications) 14-3/16″ wide
Return Air Base (Upflow Applications) 17″ wide Return Air Base (Upflow Applications) 21″ wide Return Air Base (Upflow Applications) 24″ wide Chimney Adapter Kit, up to or equal to 110K BTUh Chimney Adapter Kit, up to or equal to 110K BTUh Chimney
Adapter Kit, greater than or equal to
135K BTUh Flue Extension Vent Extension Kit Combustible Floor Base Downflow Vent Guard (Not required when vent is routed through cabinet) Natural-to- Propane Conversion
Kit Propane-to-Natural Conversion
Kit Twinning Kit FCT-ECM Motor

36045V14 X X X X X X



X
X
X X X
X
X
X –

36070V14 X X X X X X



X
X
X X X
X
X
X –

48070V17 X X X X X –
X


X
X
X X X
X
X
X X

48090V17 X X X X X –
X


X
X
X X X
X
X
X X

*. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA (formerly AGA/CGA) recognized X Accessory available

60090V21 X X X X X –

X

X
X
X X X
X
X
X X

66110V21 X X X X X –


X
X
X
X X X
X
X
X X

66135V24
X X X X X –


X
X
X
X X X
X
X
X X

Gas Orifice Kit – #42 (Nat Gas) Gas Orifice Kit – #43 (Nat Gas) Gas Orifice Kit – #44 (Nat Gas) Gas Orifice Kit – #45 (Nat Gas) Gas Orifice Kit – #46 (Nat Gas) Gas Orifice Kit – #47 (Nat Gas) Gas Orifice Kit – #48 (Nat Gas) Gas Orifice Kit – #54 (LP) Gas Orifice Kit – #55 (LP) Gas Orifice Kit – #56 (LP) Gas Orifice Kit – 1.25mm (LP) Gas Orifice Kit – 1.30mm (LP)

ORFICIES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DB078 LH32DB076 LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210

See Installation Instructions for model, altitude, and heat value usages.

DESCRIPTION HUMIDIFIER
HEAT RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR
UV LIGHTS

ACCESSORY Model HUM Model HRV Model ERV Model UVL

Bryant has a wide variety of thermostats for your system, please visit www.Bryant.com to see all thermostat and IAQ products.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12

820SB/821SB: Product Data
ACCESSORIES
DESCRIPTION Bryant Carbon Monoxide Alarm (10 pack) Bryant Evolution Air Purifier – 16×25 (407×635 mm) Bryant Evolution Air Purifier – 20×25 (508×635 mm) Bryant Evolution Air Purifier Repl. Filter- 16×25 (407×635 mm) Bryant Evolution Air Purifier Repl. Filter- 20×25 (508×635 mm) Cartridge Media Filter – 16″ (407 mm) (MERV 11) Cartridge Media Filter – 16″ (407 mm) (MERV 8) Cartridge Media Filter – 20″ (508 mm) (MERV 8) Cartridge Media Filter – 20″ (508 mm) (MERV11) Cartridge Media Filter – 24″ (610 mm) (MERV 8) Cartridge Media Filter – 24″ (610 mm) (MERV11) EZ Flex Cabinet Side or Bottom – 16″ EZ Flex Cabinet Side or Bottom – 20″ EZ Flex Replacement Filters 16″ MERV 10 EZ Flex Replacement Filters 16″ MERV 13 EZ Flex Replacement Filters 20″ MERV 10 EZ Flex Replacement Filters 20″ MERV 13 EZ Flex Replacement Filters 24″ MERV 10 EZ Flex Replacement Filters 24″ MERV 13 EZ-Flex Filter with End Caps – 16″ (407 mm) (MERV 10) EZ-Flex Filter with End Caps – 16″ (407 mm) (MERV 13) EZ- Flex Filter with End Caps – 20″ (508 mm) (MERV 10) EZ-Flex Filter with End Caps – 20″ (508 mm) (MERV 13) EZ-Flex Filter with End Caps – 24″ (610 mm) (MERV 10) EZ-Flex Filter with End Caps – 24″ (610 mm) (MERV 13) Media Filter Cabinet – 20″ Media Filter Cabinet – 24″ Media Filter Cabinet – 16″

ACCESSORY COALMBBNRB02-A10
DGAPAXX1625 DGAPAXX2025 GAPBBCAR1625-A05 GAPBBCAR2025-A05 FILXXCAR0116 FILXXCAR0016 FILXXCAR0020 FILXXCAR0120 FILXXCAR0024 FILXXCAR0124 EZXCAB–0016 EZXCAB–0020 EXPXXFIL0016 EXPXXFIL0316 EXPXXFIL0020 EXPXXFIL0320 EXPXXFIL0024 EXPXXFIL0324 EXPXXUNV0016 EXPXXUNV0316 EXPXXUNV0020 EXPXXUNV0320 EXPXXUNV0024 EXPXXUNV0324 FILCABXL0020 FILCABXL0024 FILCABXL0016

14″

17″

21″

24″

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

© 2024 Carrier. All rights reserved. A Proud Member of the Carrier Family

Edition Date: 06/24

Catalog No: PDS820SB-02 Replaces: PDS820SB-01

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

13

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

bryant User Manuals