bryant 820SB Efficiency AFUE Gas Furnace Owner’s Manual
- July 31, 2024
- bryant
Table of Contents
- 820SB Efficiency AFUE Gas Furnace
- Specifications
- Product Usage Instructions
- Performance Features:
- Installation Flexibility:
- Certification and Warranty:
- Q: Can this furnace be used in mobile homes?
- Q: What is the warranty coverage for this product?
- Q: What is the efficiency rating of this furnace?
- Q: How can I adjust the fan speed of the furnace?
820SB Efficiency AFUE Gas Furnace
“`html
Specifications
- Model: 820SB/821SB
- Series: Preferred SeriesTM
- AFUE: 80%
- Motor: Variable 25-Speed ECM
- Poise: 4-Way Multipoise
- Gas Type: Non-Condensing
- Technology: InteliSenseTM
Product Usage Instructions
Performance Features:
- Continuous Fan speed adjustable from thermostat
- Reflective sight glass for easy monitoring
- Non-volatile fault code memory for troubleshooting
- Self-test feature for system diagnostics
Installation Flexibility:
-
This furnace is not suitable for use in mobile homes, trailers,
or recreational vehicles -
For proper installation, refer to the Installation
Instructions
Certification and Warranty:
- 10-year parts limited warranty with timely registration*
- AHRI Certified TM Mark indicates manufacturer participation in
the program
*Equipment must be registered within 90 days of original
installation.
FAQ
Q: Can this furnace be used in mobile homes?
A: No, this furnace is not designed for use in mobile homes,
trailers, or recreational vehicles.
Q: What is the warranty coverage for this product?
A: The product comes with a 10-year parts limited warranty with
timely registration.
Q: What is the efficiency rating of this furnace?
A: The AFUE (Annual Fuel Utilization Efficiency) rating of this
furnace is 80%.
Q: How can I adjust the fan speed of the furnace?
A: The fan speed can be adjusted from the thermostat
settings.
“`
820SB/821SB Preferred SeriesTM 80% AFUE, Non-Communicating, Single Stage, Variable 25-Speed ECM Motor, 4-Way Multipoise, Non-Condensing Gas Furnace with InteliSenseTM Technology
Product Data
A10252
Representative drawing only. Some product models may vary.
! WARNING
This furnace is not designed for use in mobile homes, trailers, or
recreational vehicles. Such use could result in property damage and/or death.
The 820SB/821SB 4-way Multipoise Gas Furnaces feature Bryant’s QuieTechTM
noise reduction system for quiet induced draft operation. Applications are
easy with our 4-way multipoise design, through-the -furnace downflow venting,
13 different venting options, and easy service access. An inner blower door is
provided for tighter sealing in sensitive applications. The 820SB/821SB
furnaces are factory shipped for use with natural gas and convertible to
propane with approved accessory kit. The 821SB – Low NOx units are designed
for California installations and meet 40 ng/J NOx emission limits. Can be
installed in air quality management districts with a 40 ng/J NOx emissions
limit.
PERFORMANCE
· Single Stage gas valve · Variable 25-speed, constant torque (VCT) ECM blower
motor · QuieTechTM noise reduction system · Microprocessor based “smart”
control center Fan on PlusTM –
Continuous Fan speed adjustable from thermostat
· Enhanced diagnostics with easy to read 3 digit display for faults and
status and reflective sight glass, non-volatile fault code memory, and
self test feature
· Adjustable heating air temperature rise · Adjustable cooling airflow ·
Perfect LightTM Igniter
· Patented blocked vent safeguard to ensure proper furnace venting
· Inner blower door for tighter sealing
INSTALLATION FLEXIBILITY
· 4-way Multipoise furnace, 13 vent applications · On-board NFC antenna makes
setup a tap away when using the
Bryant service technician app. · HYBRIDHEAT® Dual Fuel System compatible · All
models are chimney friendly when used with accessory vent kit
APPLICATIONS
· Compact design – only 33-1/3 in. (847 mm) tall · Propane convertible with
gas conversion accessory · Convenient Air Purifier and Humidifier connections
CERTIFICATON
· Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage
less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard
193
· Residential installations eligible for consumer financing through the Retail
Credit Program
LIMITED WARRANTY
· Default 5-year parts limited warranty · 20-year heat exchanger limited
warranty
10-year parts limited warranty with timely registration Equipment must be
registered within 90 days of original installation, except in jurisdictions
where warranty benefits cannot be conditioned on registration. Applies to
original purchaser/homeowner and not available to subsequent owners except in
jurisdictions where laws dictate otherwise.
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org .
A210064
This furnace is InteliSense capable when used with an ecobee for Bryant smart thermostat with InteliSense technology. InteliSense technology allows for the collection of performance data to be sent to the cloud. Utilizing Bryant’s digital tools, dealers can gather system settings and equipment data, with homeowner opt-in, to provide quicker and more efficient service.
820SB/821SB: Product Data
UNIT PERFORMANCE DATA
Unit Size 36045V14 36070V14 48070V17 48090V17 60090V21 66110V21 66135V24
Heating Input 44,000 66,000 66,000 88,000 88,000 110,000 132,000
Efficiency AFUE 80% 80% 80% 80% 80% 80% 80%
Cooling Capacity CFM range @ .5 in.
w.c. (125 Pa) 185-1345 220-1340 245-1680 340-1480 330-2285 375-2345 340-2330
DIMENSIONAL DATA
Operating Dimensions Height x Width x Depth
in (mm) 33-1/3 x 14-3/16 x 29 (847 x 360x 737) 33-1/3 x 14-3/16 x 29 (847 x
360x 737) 33-1/3 x 17-1/2 x 29 (847 x 445 x 737) 33-1/3 x 17-1/2 x 29 (847 x
445 x 737)
33-1/3 x 21 x 29 (847 x 533 x 737) 33-1/3 x 21 x 29 (847 x 533 x 737) 33-1/3 x
24-1/2 x 29 (847 x 622x 737)
Shipping Weight lbs(kg) 111 (50.3) 118 (53.5) 129 (58.5) 134 (60.8) 149 (67.6) 155 (70.3) 170 (77.1)
NOTE: ALL DIMENSIONS IN INCH (MM)
U.S. ECCN: Not Subject to Regulation (N.S.R.)
SD5669-4 REV. –
A210785
Unit Size 36045V14 36070V14 48070V17 48090V17 60090V21 66110V21
66135V24
A
CABINET WIDTH
14-3/16 (360) 14-3/16 (360) 17-1/2 (445) 17-1/2 (445)
21 (533) 21 (533) 24-1/2 (622)
B
OUTLET WIDTH
12-9/16 (319) 12-9/16 (319) 15-7/8 (403) 15-7/8 (403) 19-3/8 (492) 19-3/8
(492) 22-7/8 (581
Dimensions
C TOP AND BOTTOM FLUE COLLAR 9-5/16 (237) 9-5/16 (237) 11-9/16 (294) 11-9/16
(294) 13-5/16 (338) 13-5/16 (338)
15-1/16 (383)
D BOTTOM INLET WIDTH
12-11/16 (322) 12-11/16 (322)
16 (406) 16 (406) 19-1/2 (495) 19-1/2 (495)
23 (584)
VENT CONNECTION
SIZE 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102)
4 (102)*
SHIP WT. LB. (KG)
111 (50.3) 118 (53.5) 129 (58.5) 134 (60.8) 149 (67.6) 155 (70.3)
170 (77.1)
*. 135 size furnaces require a 5 or 6-in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2
820SB/821SB: Product Data
MODEL NUMBER NOMENCLATURE
1 Heat Exchanger
9
|
2
Tier/NOx 8
|
3
AFUE/NOx 7
|
4
Heating Stages M
|
8 = 80% 9 = 90+%
0 = Base 1 = Legacy Line 2 = Preferred 3 = Ultra Low Nox 8 = Evolution
0 = 80% 1 = 80% Low Nox —2 = 92% 5 = 95% 6 = 96% 7 = 97% 8 = 98%
M = Modulating S = Single Stage T = Two-Stage
5 Major Series
B
|
6, 7 Cooling Capacity (CFM)
42
|
8 – 10
Heat Input 060
|
24 = 800 CFM
30 = 1000 CFM
026 = 26,000 BTU/h
A
36 = 1200 CFM
040 = 40,000 BTU/h
B
42 = 1400 CFM
060 = 60,000 BTU/h
C
48 = 1600 CFM
—
D
60 = 2000 CFM
—
66 = 2200 CFM
11
Motor Type C
|
C = Comm. VariableSpeed Constant Airflow (VCA) ECM
E= Fixed-Speeds Constant Torque (FCT) ECM
V = Variable-Speed Constant Torque (VCT) ECM
12 – 13
Width 17
|
14 Voltage (1-phase)
A
|
14 = 14.2″ 17 = 17.5″ 21 = 21.0″ 24 = 24.5″
A = 110V/60Hz B = 230V/50Hz
15
Un-used –
16 Minor Series
A
|
|
A
B
C
–
—
A190404
FURNACE COMPONENTS
INDUCER MOTOR ASSEMBLY
PRESSURE SWITCH
FLUE COLLECTOR BOX
GAS VALVE
VENT ELBOW
MAIN LIMIT SWITCH (BEHIND GAS VALVE)
BLOCKED VENT SWITCH
FLAME SENSOR
CLEARANCES
MANUAL RESET LIMIT SWITCHES
HOT SURFACE IGNITOR
BLOWER DOOR SAFETY
SWITCH
FURNACE CONTROL
BOARD
GAS MANIFOLD
GAS BURNER
BLOWER AND MOTOR
A190086
NOTE: The furnaces are factory shipped for use with natural gas. These
furnaces can be field-converted for propane gas with a factory-authorized and
listed accessory conversion kit.
A220231
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3
820SB/821SB: Product Data
SPECIFICATIONS
UNIT SIZE
HEATING AND CAPACITY AND EFFICIENCY
All Standard
All Low NOx
Input BTUh*
Upflow All Low NOx
Downflow/
Horizontal
All Standard
All Low NOx
Output Capacity (BTUh)
Upflow All Low NOx
Downflow/
Horizontal
Certified Temperature Rise Range – °F (°C) AFUE
AIRFLOW CAPACITY AND BLOWER DATA
Rated Certified External Static
Heating
Pressure
Cooling
Airflow CFM @ Rated ESP (CFM)
Heating Cooling
Cooling Capacity (tons)
400 CFM/ton 350 CFM/ton
Direct Drive Motor Type
Direct Drive Motor HP
Motor Full Load Amps
Heating Blower Control (Htg Off-Delay)
Cooling Blower Control (Time Delay Relay)
Blower Wheel Diameter x Width – In. (mm)
Air Filtration System
Filter used for Certified Watt Data
ELECTRICAL DATA
Unit Volts-Hertz-Phase
Operating Voltage Range
Min-Max
Maximum Unit Amps
Unit Ampacity
Maximum Wire Length
Measure 1 way in Ft
Feet
(M)
Meters
Minimum Wire Size
AWG
Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended)
Amps
Transformer Capacity (24 VAC output)
External Control Power Available
Heating Cooling
GAS CONTROLS
Burners
Gas Connection Size
Gas Valve (Redundant)
Mfr
Min. inlet pressure
(in.w.c.)
Max. inlet pressure
(in.w.c.)
Ignition Device
Factory installed orifice
CONNECTIONS
Communication System
Thermostat Connections
Accessory Connections
36045V14
36070V14
48070V17
48090V17
44,000
66,000
66,000
88,000
42,000
63,000
63,000
84,000
36,000
54,000
54,000
71,000
34,000
51,000
51,000
68,000
30 – 60 (17 – 33) 30 – 60 (17 – 33)
80
80
25 – 55 (14 – 31) 80
40 – 70 (22 – 39) 80
0.1 0.5 770 185-1345 3 3.5
1/2 6.7
10 x 6
0.12
0.12
0.5
0.5
1090
1300
220-1340
245-1680
3
4
3.5
4.5
Electronically Commutated Motor (ECM)
1/2
3/4
6.7
8.8
Adjustable: 90, 120, 150, 180 seconds
90 seconds
10 x 6
11 x 8
Field Supplied Filter
325531-40**
0.15 0.5 1220 340-1480 3.5 4
1/2 6.7
10 x 8
115-60-1
104-127
7.9
7.9
10.4
8.2
10.7
10.7
13.8
11
34
34
26
34
10.6
10.6
8.2
10.3
14
14
14
14
15
15
15
15
40VA 12VA 35VA
2
3
3
4
1/2in. NPT
WhiteRodgersTM
4.5 (Natural Gas)
13.6 (Natural Gas)
Silicon Nitride
43
43
43
43
InteliSenseTM G, C, W, Y/Y2, Y1, R, DHUM EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y/Y2); 2-STG AC (via Y/Y2 and Y1)
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow
shown is for bottom only return-air supply for the as-shipped speed tap. For
air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur
when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency
media filter. **. See Accessory List for part numbers available.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4
820SB/821SB: Product Data
UNIT SIZE
HEATING AND CAPACITY AND EFFICIENCY
All Standard
All Low NOx
Input BTUh*
Upflow All Low NOx
Downflow/
Horizontal
All Standard
All Low NOx
Output Capacity (BTUh)
Upflow All Low NOx
Downflow/
Horizontal
Certified Temperature Rise Range – °F (°C) AFUE
AIRFLOW CAPACITY AND BLOWER DATA
Rated Certified External Static
Heating
Pressure
Cooling
Airflow CFM @ Rated ESP (CFM)
Heating Cooling
Cooling Capacity (tons)
400 CFM/ton 350 CFM/ton
Direct Drive Motor Type
Direct Drive Motor HP
Motor Full Load Amps
Heating Blower Control (Htg Off-Delay)
Cooling Blower Control (Time Delay Relay)
Blower Wheel Diameter x Width – In. (mm)
Air Filtration System
Filter used for Certified Watt Data
ELECTRICAL DATA
Unit Volts-Hertz-Phase
Operating Voltage Range
Min-Max
Maximum Unit Amps
Unit Ampacity
Maximum Wire Length
Measure 1 way in Ft
Feet
(M)
Meters
Minimum Wire Size
AWG
Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended)
Amps
Transformer Capacity (24 VAC output)
External Control Power Available
Heating Cooling
GAS CONTROLS
Burners
Gas Connection Size
Gas Valve (Redundant)
Mfr
Min. inlet pressure
(in.w.c.)
Max. inlet pressure
(in.w.c.)
Ignition Device
Factory installed orifice
CONNECTIONS
Communication System
Thermostat Connections
Accessory Connections
60090V21
66110V21
66135V24
88,000
110,000
132,000
84,000
105,000
126,000
71,000
90,000
107,000
68,000
85,000
102,000
25 – 55 (14 – 31) 80
30 – 60 (17 – 33) 80
40 – 70 (22 – 39) 80
0.15 0.5 1690 330-2285 5 5.5
1 11.5
11 x 11
0.2 0.5 1880 375-2345 5 5.5 Electronically Commutated Motor (ECM) 1 11.5 Adjustable: 90, 120, 150, 180 seconds 90 seconds 11 x 11 Field Supplied Filter 325531-40**
0.2 0.5 1930 340-2330 5 5.5
1 11.5
11 x 11
115-60-1
104-127
13.9
14.4
18.1
18.6
14.4 18.6
31
30
30
9.6
9.4
9.4
12
12
12
20
20
20
40VA 12VA 35VA
4
5
6
1/2in. NPT
WhiteRodgersTM
4.5 (Natural Gas)
13.6 (Natural Gas)
Silicon Nitride
43
43
43
InteliSenseTM G, C, W, Y/Y2, Y1, R, DHUM EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y/Y2); 2-STG AC (via Y/Y2 and Y1)
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow
shown is for bottom only return-air supply for the as-shipped speed tap. For
air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur
when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency
media filter. **. See Accessory List for part numbers available.
ICS = Isolated Combustion System
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5
820SB/821SB: Product Data
AIR DELIVERY (WITH FILTER)
Table 1 Air Delivery – CFM (with filter)*
Unit Size 36045V14
36070V14
Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Default Setting Cont. Fan Heating
Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling
0.1 455 500 565 600 655 720 770 795 825 880 910 935 985 1015 1045 1075 1110 1160 1190 1220 1250 1280 1325 1400 1485 480 525 565 620 650 700 715 760 815 870 920 980 1035 1070 1100 1130 1160 1190 1220 1250 1285 1315 1345 1385 1470
0.2 390 440 510 550 605 675 725 755 785 840 875 900 950 980 1010 1045 1080 1130 1160 1190 1225 1255 1295 1375 1460 420 470 510 570 605 655 675 720 780 830 885 950 1005 1040 1070 1100 1130 1160 1190 1225 1255 1290 1320 1360 1445
0.3 325 380 450 495 555 630 680 715 745 800 835 865 915 950 980 1015 1045 1100 1130 1160 1195 1225 1270 1350 1420 355 410 455 520 560 615 630 680 740 795 850 915 975 1010 1040 1070 1105 1135 1165 1200 1230 1265 1295 1335 1415
External Static Pressure (in. w.c.)
0.4
0.5
0.6
0.7
0.8
255 185 115
–
–
320 255 185 120
–
395 340 285 220
145
440 390 340 285
225
505 455 410 365
310
585 535 490 450
405
640 595 550 505
465
670 630 585 540
500
705 660 620 575
535
765 725 685 645
605
800 760 725 685
645
830 795 755 720
685
885 850 815 780
745
920 885 850 820
785
945 915 885 850
815
980 950 920 890
855
1015 985 955 925
895
1070 1040 1015 985
955
1100 1075 1045 1015 990
1135 1105 1075 1050 1020
1165 1140 1115 1085 1060
1200 1175 1145 1120 1095
1245 1220 1190 1165 1140
1325 1300 1275 1250 1225
1380 1345 1305 1260 1225
285 220 160 115
–
340 280 225 170
–
395 340 275 225
175
465 410 360 300
250
510 460 405 355
300
565 520 470 420
375
585 540 495 440
395
640 595 550 505
455
700 660 620 580
535
760 725 685 645
605
815 780 745 710
675
885 850 815 780
745
940 910 880 850
815
980 945 915 885
855
1010 980 950 920
890
1045 1015 985 955
925
1075 1045 1020 990
960
1105 1080 1050 1025 995
1135 1110 1080 1055 1025
1170 1145 1115 1090 1065
1205 1180 1150 1125 1100
1235 1210 1185 1160 1135
1270 1245 1215 1190 1165
1310 1285 1260 1235 1215
1375 1340 1300 1260 1225
0.9 –
145 255 360 425 460 500 565 605 645 710 750 785 825 860 920 960 990 1030 1065
1115 1180 1180
135 205 250 325 345 410 490 565 635 710 780 820 860 895 930 965 1000 1035 1070
1110 1140 1180 1180
1 190 310 380 425 460 530 570 610 675 715 750 790 830 890 930 960 1000 1040 1085 1095 1100 160 210 275 300 365 450 525 595 675 750 790 830 865 900 940 970 1010 1045 1085 1115 1140 1140
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6
820SB/821SB: Product Data
Unit Size 48070V17
48090V17
Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Table 1 Air Delivery – CFM (with filter)* (Continued)
Default Setting Cont. Fan
Heating Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling
0.1 560 615 670 745 810 875 955 1025 1090 1170 1215 1260 1310 1345 1385 1420 1460 1495 1535 1575 1620 1655 1690 1750 1825 660 700 750 805 855 900 945 975 1015 1070 1130 1170 1200 1240 1260 1295 1325 1360 1395 1430 1460 1500 1535 1575 1615
0.2 480 540 600 680 750 815 900 970 1045 1125 1170 1220 1270 1305 1345 1380 1420 1460 1500 1540 1585 1620 1655 1720 1795 580 625 685 740 795 845 890 925 965 1020 1085 1125 1155 1200 1220 1255 1285 1325 1360 1390 1425 1465 1500 1540 1580
0.3 395 465 530 615 690 760 845 920 995 1080 1125 1175 1230 1265 1305 1345 1385 1425 1460 1505 1550 1585 1625 1690 1760 480 525 585 670 730 785 835 865 915 970 1040 1080 1115 1160 1180 1215 1250 1285 1320 1355 1390 1430 1465 1505 1545
External Static Pressure (in. w.c.)
0.4
0.5
0.6
0.7
0.8
315 245 165
–
–
385 320 255 175
–
460 385 325 265
190
550 485 415 360
305
630 570 505 445
395
705 645 590 530
470
795 740 685 630
580
870 825 775 725
675
945 900 855 805
760
1035 990 950 905
860
1080 1040 995 950
910
1135 1095 1055 1010 970
1190 1150 1110 1070 1030
1225 1190 1150 1110 1070
1265 1225 1185 1150 1110
1305 1270 1230 1195 1155
1345 1310 1275 1235 1205
1385 1350 1315 1280 1245
1425 1395 1355 1320 1290
1475 1440 1405 1370 1340
1515 1485 1450 1420 1390
1555 1525 1490 1460 1430
1595 1565 1535 1500 1475
1660 1630 1600 1570 1540
1720 1680 1635 1595 1555
410 340 265 210
150
455 395 320 255
205
520 460 395 325
270
580 520 465 405
335
640 580 520 465
405
695 635 580 525
470
770 685 630 575
530
810 725 665 615
565
860 775 715 665
615
920 865 785 730
680
990 945 865 805
755
1030 985 930 855
805
1070 1020 975 900
845
1115 1070 1025 980
905
1140 1095 1050 1005 935
1175 1130 1090 1045 980
1210 1170 1125 1085 1035
1245 1210 1165 1125 1085
1285 1245 1205 1165 1125
1320 1285 1245 1205 1165
1355 1320 1280 1245 1205
1395 1360 1320 1285 1245
1430 1400 1360 1325 1290
1475 1440 1405 1370 1335
1515 1480 1450 1410 1350
0.9 –
245 340 420 525 625 715 815 870 930 990 1035 1075 1120 1165 1210 1255 1305
1360 1400 1445 1500 1510
145 220 280 345 410 475 515 570 630 710 760 800 855 880 925 965 1015 1075 1125
1165 1210 1255 1285 1285
1 165 285 375 470 575 665 775 825 890 955 995 1040 1085 1135 1180 1225 1275 1330 1370 1420 1460 1470 165 235 295 355 415 460 520 590 665 710 755 810 840 880 920 960 1010 1060 1115 1170 1215 1225 1225
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7
820SB/821SB: Product Data
Unit Size 60090V21
66110V21
Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Table 1 Air Delivery – CFM (with filter)* (Continued)
Default Setting Cont. Fan
Heating/Low Cooling
High Cooling Cont. Fan
Low Cooling Heating
High Cooling
0.1 780 860 930 1030 1125 1210 1285 1385 1475 1565 1670 1720 1765 1815 1860 1915 1970 2020 2070 2120 2170 2220 2270 2355 2470 815 890 1000 1100 1190 1280 1385 1480 1575 1685 1785 1880 1935 1995 2010 2060 2095 2140 2190 2250 2305 2355 2400 2460 2515
0.2 660 740 820 930 1035 1125 1210 1310 1410 1500 1605 1660 1710 1760 1805 1865 1915 1965 2025 2075 2125 2175 2225 2315 2425 690 780 900 1005 1105 1195 1305 1405 1505 1620 1725 1825 1880 1940 1960 2005 2045 2090 2145 2205 2260 2305 2355 2420 2470
0.3 545 645 725 835 935 1035 1125 1235 1340 1435 1550 1605 1655 1705 1755 1815 1865 1920 1975 2030 2080 2130 2185 2275 2385 580 670 800 910 1015 1110 1225 1335 1435 1555 1660 1765 1825 1885 1905 1950 1990 2040 2095 2155 2215 2260 2315 2375 2430
External Static Pressure (in. w.c.)
0.4
0.5
0.6
0.7
0.8
440 330 210
–
–
535 440 340 220
–
625 530 440 350
230
755 655 570 485
400
860 785 690 610
530
955 880 805 725
645
1040 975 905 830
750
1150 1085 1020 955
885
1265 1190 1130 1065 1010
1365 1290 1230 1175 1115
1485 1415 1350 1295 1240
1540 1475 1410 1350 1300
1595 1530 1465 1405 1355
1650 1585 1525 1460 1410
1700 1640 1580 1515 1465
1760 1705 1645 1585 1530
1815 1760 1705 1645 1590
1870 1820 1765 1710 1650
1930 1880 1830 1775 1720
1985 1935 1885 1835 1785
2035 1990 1945 1895 1845
2090 2045 2000 1955 1910
2145 2100 2055 2015 1970
2240 2200 2160 2115 2075
2335 2285 2230 2175 2115
475 375 285 190
–
570 475 385 300
215
700 615 525 440
360
820 735 650 570
490
930 840 765 685
610
1025 945 865 795
725
1150 1070 995 920
860
1260 1190 1120 1045 975
1365 1295 1230 1165 1095
1485 1420 1360 1295 1230
1600 1535 1475 1415 1355
1705 1645 1590 1530 1470
1765 1710 1650 1595 1545
1825 1770 1715 1660 1605
1850 1790 1740 1685 1630
1900 1840 1790 1735 1685
1940 1885 1835 1780 1730
1990 1935 1885 1835 1790
2045 1995 1940 1895 1850
2105 2055 2010 1960 1915
2165 2120 2075 2030 1985
2220 2175 2130 2085 2040
2270 2230 2185 2145 2100
2335 2290 2250 2205 2150
2385 2345 2290 2230 2170
0.9 –
310 450 570 675 815 940 1060 1180 1245 1305 1360 1415 1480 1540 1605 1670 1730
1795 1860 1920 2020 2050
135 285 415 535 645 790 920 1030 1165 1300 1415 1490 1555 1580 1635 1680 1740
1805 1870 1940 2000 2060 2100 2110
1 185 370 495 610 745 875 995 1130 1195 1255 1310 1370 1435 1495 1560 1625 1685 1750 1815 1875 1965 1985 210 350 465 575 720 850 975 1105 1235 1365 1435 1505 1530 1585 1635 1695 1755 1830 1900 1960 2015 2045 2050
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8
820SB/821SB: Product Data
Table 1 Air Delivery – CFM (with filter)* (Continued)
Unit Size
Airflow Setting
Default Setting
External Static Pressure (in. w.c.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1
Cont. Fan
805 675 575 445 340 230 115
–
–
–
2
875 765 660 555 440 340 230
120
–
–
3
950 840 740 650 540 440 435
290
175
125
4
1045 945 850 765 675 560 475
385
295
195
5
1135 1045 950 865 785 700 595
515
430
350
6
1220 1135 1045 960 885 810 725
630
550
475
7
1320 1245 1165 1080 1010 940 865
790
690
620
8
1415 1345 1270 1190 1120 1055 990
920
845
755
9
1535 1465 1395 1325 1250 1185 1125 1065
1000
930
10
1615 1555 1485 1420 1350 1285 1225 1170
1110
1050
11
Low Cooling
1715 1660 1600 1535 1470 1400 1345 1290
1235
1180
12
66135V24
13
1770 1710 1650 1590 1525 1460 1400 1815 1760 1700 1640 1580 1515 1455
1350 1405
1295 1355
1240 1300
14
1860 1805 1750 1690 1630 1570 1510 1455
1405
1360
15
1925 1870 1815 1760 1705 1645 1585 1530
1475
1430
16
Heating
1980 1930 1875 1820 1765 1705 1650 1595
1545
1495
17
2035 1980 1930 1875 1825 1770 1710 1655
1605
1560
18
2085 2035 1985 1935 1880 1825 1775 1720
1670
1625
19
2135 2090 2040 1990 1940 1885 1835 1785
1730
1685
20
2185 2140 2090 2040 1995 1945 1895 1845
1795
1750
21
2235 2190 2145 2095 2050 2000 1955 1905
1855
1810
22
High Cooling
2285 2240 2195 2150 2105 2060 2010 1965
1920
1875
23
2335 2290 2245 2200 2155 2115 2070 2025
1980
1935
24
2415 2370 2330 2285 2245 2205 2160 2115
2065
2010
25
2505 2460 2420 2380 2330 2275 2215 2155
2090
2020
NOTE:
1. A filter is required for each return-air inlet. Airflow performance
included 3/4-in. (19 mm) washable filter media such as contained in a factory
– authorized accessory filter rack. See accessory list. To determine airflow
performance without this filter, assume an additional 0.1-in. w.c. available
external static pressure.
2. Adjust the blower airflow setting as necessary for the proper air
temperature rise for each installation. 3. Airflows over 1800 CFM require
bottom return, two-side return, or bottom and side return. A minimum filter
size of 20″ x 25″ (508 x 635 mm) is required. 4. For upflow applications, air
entering from one side into both the side of the furnace and a return air base
counts as a side and bottom return 5. The – entry indicates unstable operating
conditions
Table 2 Default Airflow Settings
Default Airflow Settings*
Designated Airflow Settings
Unit Size
Heating
High Cooling
Low Cooling
Heating
Constant Fan
36045V14
7
23
13
(3 – 11)
(1 – 9)
36070V14
15
23
13
(10 – 19)
(1 – 9)
48070V17
13
25
14
(7 – 15)
(1 – 4)
48090V17
14
25
13
(8 – 21)
(1 – 10)
60090V21
12
23
12
(7 – 17)
(1 – 9)
66110V21
13
21
11
(8 – 18)
(1 – 9)
66135V24
16
22
11
(9 – 19)
(1 – 8)
*. Setting #1 is the default setting for Constant Fan
TYPICAL WIRING SCHEMATIC
FURNACE CONTROL BOARD
A200307
Manufacturer reserves the right to change, at any time, specifications and
designs without notice and without obligations. 9
A221520
820SB/821SB: Product Data
VENTING CONFIGURATIONS
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL RIGHT
A02068
SEE NOTES: 1, 2, 4, 7, 8, 9
HORIZONTAL RIGHT
A02069
SEE NOTES: 1, 2, 4, 7, 8, 9
UPFLOW
A02058
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL RIGHT
A02070
SEE NOTES: 1, 2, 4, 7, 8, 9
HORIZONTAL LEFT
A02064
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT
A02065
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
DOWNFLOW
A02061
SEE NOTES: 1, 2, 3, 4, 5, 7, 8, 9
DOWNFLOW
A02060
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT
A02067
SEE NOTES: 1, 2, 4, 5, 7, 8, 9
HORIZONTAL LEFT
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10
A02066
820SB/821SB: Product Data UPFLOW
DOWNFLOW
A02059
Venting notes
1. For common vent, vent connector sizing and vent material: United States,
latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54.
2. Immediately increase to 5-in. (127 mm) vent connector outside furnace
casing when 5-in. (127 mm) vent connector required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B
vent immediately after exiting the furnace, except when Downflow Vent Guard is
used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4-in. (102 mm) single wall vent must be used inside furnace casing and the
Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with
bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications.
Refer to Chimney Adapter Kits for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet
metal screws, space approximately 180 apart.
9. Secure all other single wall vent connector joints with (3) corrosion-
resistant screws spaced approximately 120 apart. Secure Type B vent connectors
per vent connector manufacturer’s recommendations.
A02063
DOWNFLOW
A02062
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11
820SB/821SB: Product Data
ACCESSORIES
PART NO. ACG1425NCB ACG1625NCF ACG2025NCJ ACG2424NCL
325531-402 325531-403 325531-404 KGADA0101ALL KGADA0201ALL KGADA0301ALL
KGARP0301B14
KGARP0301B17
KGARP0301B21
KGARP0301B24
KGACA02014FC
KGACA02015FC
KGAFE0112UPH KGAVE0101DNH KGASB0201ALL
KGBVG0101DFG
AGAGC8NPS01C
AGAGC8PNS01C* AGATWNDTE01C
DESCRIPTION External Filter Rack, 14-1/2 x 25″
External Filter Rack, 16 x 25″
External Filter Rack 20 x 25″
External Filter Rack 24-1/2 x 24″
Washable filter, 3/4″ x 16″ x 25″
Washable filter, 3/4″ x 21″ x 25″
Washable filter 3/4″ x 24″ x 25″
Coil Adapter Kits – No Offset Coil Adapter Kits – Single Offset Coil Adapter
Kits – Double Offset
Return Air Base (Upflow Applications) 14-3/16″ wide
Return Air Base (Upflow Applications) 17″ wide Return Air Base (Upflow
Applications) 21″ wide Return Air Base (Upflow Applications) 24″ wide Chimney
Adapter Kit, up to or equal to 110K BTUh Chimney Adapter Kit, up to or equal
to 110K BTUh Chimney
Adapter Kit, greater than or equal to
135K BTUh Flue Extension Vent Extension Kit Combustible Floor Base Downflow
Vent Guard (Not required when vent is routed through cabinet) Natural-to-
Propane Conversion
Kit Propane-to-Natural Conversion
Kit Twinning Kit FCT-ECM Motor
36045V14 X X X X X X
–
–
–
X
X
X X X
X
X
X –
36070V14 X X X X X X
–
–
–
X
X
X X X
X
X
X –
48070V17 X X X X X –
X
–
–
X
X
X X X
X
X
X X
48090V17 X X X X X –
X
–
–
X
X
X X X
X
X
X X
*. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA (formerly AGA/CGA) recognized X Accessory available
60090V21 X X X X X –
–
X
–
X
X
X X X
X
X
X X
66110V21 X X X X X –
–
–
X
X
X
X X X
X
X
X X
66135V24
X X X X X –
–
–
X
X
X
X X X
X
X
X X
Gas Orifice Kit – #42 (Nat Gas) Gas Orifice Kit – #43 (Nat Gas) Gas Orifice Kit – #44 (Nat Gas) Gas Orifice Kit – #45 (Nat Gas) Gas Orifice Kit – #46 (Nat Gas) Gas Orifice Kit – #47 (Nat Gas) Gas Orifice Kit – #48 (Nat Gas) Gas Orifice Kit – #54 (LP) Gas Orifice Kit – #55 (LP) Gas Orifice Kit – #56 (LP) Gas Orifice Kit – 1.25mm (LP) Gas Orifice Kit – 1.30mm (LP)
ORFICIES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DB078 LH32DB076 LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210
See Installation Instructions for model, altitude, and heat value usages.
DESCRIPTION HUMIDIFIER
HEAT RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR
UV LIGHTS
ACCESSORY Model HUM Model HRV Model ERV Model UVL
Bryant has a wide variety of thermostats for your system, please visit www.Bryant.com to see all thermostat and IAQ products.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12
820SB/821SB: Product Data
ACCESSORIES
DESCRIPTION Bryant Carbon Monoxide Alarm (10 pack) Bryant Evolution Air
Purifier – 16×25 (407×635 mm) Bryant Evolution Air Purifier – 20×25 (508×635
mm) Bryant Evolution Air Purifier Repl. Filter- 16×25 (407×635 mm) Bryant
Evolution Air Purifier Repl. Filter- 20×25 (508×635 mm) Cartridge Media Filter
– 16″ (407 mm) (MERV 11) Cartridge Media Filter – 16″ (407 mm) (MERV 8)
Cartridge Media Filter – 20″ (508 mm) (MERV 8) Cartridge Media Filter – 20″
(508 mm) (MERV11) Cartridge Media Filter – 24″ (610 mm) (MERV 8) Cartridge
Media Filter – 24″ (610 mm) (MERV11) EZ Flex Cabinet Side or Bottom – 16″ EZ
Flex Cabinet Side or Bottom – 20″ EZ Flex Replacement Filters 16″ MERV 10 EZ
Flex Replacement Filters 16″ MERV 13 EZ Flex Replacement Filters 20″ MERV 10
EZ Flex Replacement Filters 20″ MERV 13 EZ Flex Replacement Filters 24″ MERV
10 EZ Flex Replacement Filters 24″ MERV 13 EZ-Flex Filter with End Caps – 16″
(407 mm) (MERV 10) EZ-Flex Filter with End Caps – 16″ (407 mm) (MERV 13) EZ-
Flex Filter with End Caps – 20″ (508 mm) (MERV 10) EZ-Flex Filter with End
Caps – 20″ (508 mm) (MERV 13) EZ-Flex Filter with End Caps – 24″ (610 mm)
(MERV 10) EZ-Flex Filter with End Caps – 24″ (610 mm) (MERV 13) Media Filter
Cabinet – 20″ Media Filter Cabinet – 24″ Media Filter Cabinet – 16″
ACCESSORY COALMBBNRB02-A10
DGAPAXX1625 DGAPAXX2025 GAPBBCAR1625-A05 GAPBBCAR2025-A05 FILXXCAR0116
FILXXCAR0016 FILXXCAR0020 FILXXCAR0120 FILXXCAR0024 FILXXCAR0124 EZXCAB–0016
EZXCAB–0020 EXPXXFIL0016 EXPXXFIL0316 EXPXXFIL0020 EXPXXFIL0320 EXPXXFIL0024
EXPXXFIL0324 EXPXXUNV0016 EXPXXUNV0316 EXPXXUNV0020 EXPXXUNV0320 EXPXXUNV0024
EXPXXUNV0324 FILCABXL0020 FILCABXL0024 FILCABXL0016
14″
17″
21″
24″
X
X
X
X
X
X
–
–
–
–
X
X
X
X
–
–
–
–
X
X
X
X
–
–
X
X
–
–
–
–
X
–
–
–
X
–
–
–
–
X
–
–
–
X
X
X
–
–
–
–
X
X
X
X
–
–
X
X
–
–
–
–
X
–
–
–
X
–
–
–
–
X
–
–
–
X
X
X
–
–
X
X
–
–
–
–
X
–
–
–
X
–
–
–
–
X
–
–
–
X
–
–
X
–
–
–
–
X
X
X
–
–
© 2024 Carrier. All rights reserved. A Proud Member of the Carrier Family
Edition Date: 06/24
Catalog No: PDS820SB-02 Replaces: PDS820SB-01
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
13
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>