VS5-3-F Laser Level
“`html
Product Technical Specifications
- Laser Safety Standards: Class II laser products
- Laser Wavelength: Green light 515nm
- Automatic Leveling Range: 1/4 inch
- Automatic Leveling Time
- Horizontal Accuracy
- Vertical Accuracy
- Line Width
- Brightness Adjustment: 3 Levels of Brightness
- Power Supply
- Operating Temperature
- Storage Temperature
- Remote Control Distance
- Base Thread Size
Product Usage Instructions
1. Place the Laser Level
Place the level on the ground or install it on a bracket fixed
on the wall.
2. Adjust the Instrument
Fix the instrument on the bracket and adjust the tail and side
knobs so that the instrument is flat against the wall.
3. Turn on the Laser Level
Turn on the locking switch of the level to start the machine.
The horizontal laser will automatically emit horizontal laser rays.
Control the vertical or horizontal line through the buttons on the
control panel.
4. Operating Modes
To enter slash mode, long press (2-3s) the O key on the control
panel. Long press it again to exit slash mode. Adjust brightness
levels by pressing the B button.
5. Remote Control Functionality
Use the remote control to turn on/off horizontal and vertical
lights, and to control modulation modes.
Accuracy Check
Horizontal Line Check
- Establish 4 points on the four walls as original coordinates
when the horizontal laser is projected.
Vertical Line Check
- Hang a plumb line on the wall.
- Place the instrument 5 meters from the wall.
Frequently Asked Questions (FAQ)
Q: How do I adjust the brightness of the laser level?
A: Short press the B button to cycle through the three levels of
brightness – 100%, 75%, and 50%.
Q: What is slash mode?
A: Slash mode can be entered by long pressing the O key and
allows for specific functionality. Long press it again to exit
slash mode.
Q: How do I check the accuracy of the horizontal line?
A: Establish 4 points on the four walls as original coordinates
when the horizontal laser is projected.
“`
Product Introduction Manual VS5-3-F Laser Level
Please be sure to read all safety clauses and operating instructions in this
manual before using the product -1-
PDF created with pdfFactory Pro trial version www
Product Description
1 Host Introduction
Horizontal Windows Mainframe Housing Vertical Windows
Battery Cover Control Panel Locking Switch
Main unit Base
2 Control Panel
Vertical Button
Horizontal Button
Modulation Burst Button
Battery Indicator
Brightness Adjustment Buzzer Off and On Button
-2-
PDF created with pdfFactory Pro trial version www
3 Bracket Introduction
Move Forward and Backward
4 Remote Control Introduction
Vertical Control Button Horizontal Control Button
Modulation Control Button
5 Other Accessories
L-Shaped Iron Plate
Adjust Up and Down
Rotate Left and Right
1
Laser Target Card Plate 2
Battery
3
Charger
4
Bracket Accessory
-3-
PDF created with pdfFactory Pro trial version www
6 Product Technical Specifications
Laser Safety Standards Laser Wavelength Automatic Leveling Range Automatic Leveling Time Horizontal Accuracy Vertical Accuracy Line Width Brightness Adjustment 3 Levels of Brightness Power Supply Operating Temperature Storage Temperature Remote Control Distance Base Thread Size
Class II laser products Green light 515nm
±0.3mm/m ±0.3mm/m 2mm/5m 100%, 75%, 50% DC3.7V 5000mAh
1/4 inch
7 Operation Method
1 Place the level on the ground or install it on a bracket fixed on the wall.
2 Fix the instrument on the bracket and adjust the tail and side knobs on
the bracket so that the instrument is flat against the wall. 3 Turn on the
locking switch of the level, the machine starts to work, the horizontal
outlet opens automatically, emits horizontal laser rays, and controls the
vertical or horizontal line through V or H on the key board. 4 When this model
is powered on, long press (2-3S) the O key on the key panel to enter the slash
mode; long press (2-3S) the O key on the key panel again to exit the slash
mode.
-4-
PDF created with pdfFactory Pro trial version www
5 When this model is powered on, the vertical and horizontal light of the
instrument are the brightest (100%). Short press the B button to adjust the
vertical and horizontal light brightness of the instrument (3 levels of
brightness, 100%, 75%, 50%, cycle in sequence)
6 button on the remote control to turn on or off the horizontal light of the
instrument, press the V button on the remote control to control the vertical
light of the instrument on or off, press the The OD button controls the
switching of instrument modulation, strobe and normal states.
8 Accuracy Check
Horizontal line check
1 2 Establish 4 points arbitrarily on the four walls as the original
coordinates when the
horizontal laser is projected. 3
Establish 4 points arbitrarily on the four walls as the original coordinates
when the horizontal laser is projected.
Vertical line check
1 Hang a plumb line on the wall. 2 Place the instrument 5 meters from the
wall.
-5-
PDF created with pdfFactory Pro trial version www
3 Use the vertical laser line emitted by the instrument to align the plumb
line to see if the distance between the two is greater than the error range,
and then
the plumb line, and check the distance between the two.is greater than the
error range. 4 The remaining 1 laser inspection is the same as step 3.
9 Common Faults and Troubleshooting
Phenomenon Cause Analysis Solutions
The switch is turned to the “ON” position, but the laser line does not light up.
1. Low battery power 2. The instrument exceeds
the operating temperature range
1. Charge the lithium battery 2. Make sure the operating
temperature of the instrument is between
Laser line flashes
The switch is turned to the “ON” position, but the laser line does not light
up.
The laser line become thicker or blurry
Laser line visibility deteriorates
Instrument out of operating range
1. The ambient temperature of the instrument changes suddenly
2. The instrument has been subject to strong impact or drop.
Adjust the instrument to a roughly level state
1. Leave it for a period of time to make the temperature of the instrument
consistent with the environment.
2. Send for repair
There is dust on the surface of the light outlet glass
Clean with soft cloth dampened in water
1. The ambient light is too bright
2. Low battery power
1. Reduce ambient light brightness
2. Charge the lithium battery
-6-
PDF created with pdfFactory Pro trial version www
10 Operation Precautions
1 The lithium battery wall mounter has only a weak power when it leaves the
factory. Please charge it before use.
2 Before each use, self-check the accuracy of the instrument according to the
instructions in the operation manual, and calibrate the accuracy of the
instrument regularly.
3 Avoid heavy impact or vibration, and lock the locking switch when not in
use. 4 Do not use organic solutions to wipe the surface of the instrument. 5
Avoid exposing the instrument to sunlight. 6 When the instrument is not used
for a long time, the battery should be removed. 7 The instrument should be
stored in a dry and ventilated environment.
11 Security Terms
1 Do not attempt to change the performance of the laser in any way, as this
may cause dangerous laser exposure.
2 This product is harmless to the human body, but do not look directly at the
laser. 3 Class II laser products. Turn on the laser only when using the
instrument.
-7-
PDF created with pdfFactory Pro trial version www
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
-Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
- RF warning for Portable device: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>