HEIMAN matter M1-M Smart Motion Sensor User Manual

July 31, 2024
HEIMAN

HEIMAN matter M1-M Smart Motion Sensor

Specifications

  • Working voltage: DC 3V (CR2)
  • Wireless: 2.4GHz
  • Wireless distance: 70m (in the open area indoors)
  • Installation mode: Wall mounting, Ceiling mounting
  • Detection angle: 1.5m
  • Mounting height: 2.8m
  • Detection distance: 7m (25′)
  • Illuminance detection range: 0~1200Lux
  • Working temperature: -10°C to +55°C
  • Working humidity: 95% (no condensation)
  • Dimensions: 42xH43mm (mounting bracket not included)

Product Introduction

This smart motion sensor, is equipped with automatic valve adjustment technology and automatic temperature compensation technology, so the sensor stability is greatly enhanced, which can effectively prevent the sensor from false alarms and sensor sensitivity reduction caused by temperature changes.

It also adopts wireless networking technology, featuring high security and intelligent linkage characteristics. When the gateway is in “arm” status, once the sensor detects someone moving, it will send alarm signals to the smart gateway and a real-time alarm message will be sent to the user APP through the cloud server.

Illustrations

Technical parameters

Networking

  • The sensor has to work with the gateway, please add the gateway to the corresponding APP first.

  • Long press the reset button by the pin key for about 5 seconds to activate the sensor and it will also enter networking status automatically.

  • Open the APP, select the gateway, tap “+” in my gateway page to add a subdevice, select “Smart
    Motion Sensor” and continue to operate according to APP prompts.

  • WARNING: The sensor must be activated first before normal working.

  • Network inclusion: After activation, the sensor will enter networking status automatically: green LED flashes quickly (5 times/second). When the green LED keeps on for 3 seconds and goes off. APP will prompt network inclusion to be done.

  • If the sensor can not be added to the network successfully within 60 seconds, the green LED will flash slowly for 3 seconds (twice/second) and go off,
    APP will prompt network inclusion fails.
    Note: Pressing the reset button again during networking status will stop the networking process and the green LED will flash slowly for 3 seconds (twice/second) and go off.

Tips: Due to the APP upgrade and update, this guideline may be slightly different from the actual operation, please follow the instructions in the APP. The user could upgrade to the official latest software version to have a better user experience.

Visual indication

Working status instructions

  • Warm-up status : after powered on, the sensor will enter warm-up status for 30 seconds, red LED flash once per second.
  • Test status: the sensor will enter test status for about 20 minutes after the warm-up period ends. In test status, when someone moving is detected, the red LED will be on for about 1 second, and meanwhile “someone is moving” is reported to the user APP, if it detects continuous human movement, the red LED is on once/5 seconds, only if the sensor determines that no one is moving and it last for 1 minute, “No one moves” will be reported to user APP.
  • Power saving mode: the sensor will enter power saving mode at the end of the test mode. Power saving mode is also the sensor’s long-term working mode. In power saving mode, when someone moving is detected, the red LED will be on for about 1 second, and meanwhile “someone is moving” is reported to the user APP.

If it detects continuous human movement, neither the indicator LED nor the APP will alert someone moving is detected. Only after “no one moves” is reported, will the alert function be recovered.
The condition “no one moves” is reported that the sensor determines that no one moves for a certain period, the value is 1 minute.

Installation

  • Installation locations to avoid: It’s forbidden to install the sensor where there is direct exposure to sunshine, under rotatable objects, near the air-conditioner or heat source, pets may touch, or outdoors.
  • The installation surface should be solid without vibration.
  • Recommended installation locations:
    Install the sensor where the intruder may pass by.

Detection area

Installation instructions

Method 1:

  • Attach the sensor to the user’s chosen installation place with double-sided adhesive tape.
  • Notes : for wall mouting, pay attention to the “ ” icon on the bottom cover upward.

Method 2: Attach the mounting bracket to the user’s chosen installation place with double-sided adhesive tape.

Notes:

  • a. For wall mounting, the “ ”icon on the mounting bracket should be upward. Align“ ”icon on the bottom cover and“ ”icon on the mounting bracket to lock them in place.
  • b. For ceiling mounting, align“ ”icon on the bottom cover and“ ”icon on the mounting bracket to lock them in place.

Attention

  1. Make sure the installation surface is smooth, flat, stable, dry, and clean.
  2. After installation, check if the sensor is installed firmly on the installation surface regularly.

Battery replacement

  • Press the disassembly hole by the pin key, and remove the bottom cover from the sensor body.

  • Pay attention to the positive and negative electrode of the battery while replacing the battery. When the bottom cover is installed, please align the arrow icons shown below. Dispose of used batteries in an environmentally friendly way.

FCC Statement

  • The information in the user manual is for reference only and does not constitute any form of commitment.
  • Without the written permission of the manufacturer, any individual or organization shall not extract or copy part or all of the contents of this user manual, and shall not spread it in any form.
  • As the technology is constantly updated, the manufacturer reserves the right to modify the user manual without prior notice. If the user manual and the actual operations are inconsistent, please refer to the actual operation,s and the final interpretation is reserved to the manufacturer herein.

FAQ

  • Q: What should I do if the sensor does not detect any movement?
    • A: If the sensor does not detect any movement for a certain period (1 minute), it will recover the alert function. Continuous human movement may not trigger the alert function until no movement is reported.
  • Q: How do I know if the sensor is in networking status?
    • A: The red LED will flash quickly (5 times/second) during network inclusion status. The green LED will keep on for 3 seconds and then turn off when networking is done.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals