AI-1-4 AromaMist Starter Kit Instruction Manual
- July 26, 2024
- AROMAMIST
Table of Contents
AI-1-4 AromaMist Starter Kit
Specifications
- Limited Lifetime Warranty
Product Information
Congratulations on your purchase of the AromaMist chemical metering pump, a
groundbreaking solution for chemical metering needs. This manual provides
comprehensive guidance on unpacking, installation, electrical and plumbing
connection, safety considerations, maintenance, troubleshooting, and warranty
information. Please read the manual thoroughly before proceeding with the
operation of the pump.
Safety Considerations
It is crucial to follow safety protocols and precautions when handling
chemical metering pumps. Always wear appropriate protective clothing and gear
to prevent accidental exposure to chemicals. In case of a chemical spillage,
refer to the Material Safety Data Sheet (MSDS) for specific instructions
related to the chemical involved.
NOTE: All AromaMist pumps are primed with water before leaving the factory.
-
Chemical Compatibility
AromaMist metering pumps are designed to work with most liquid chemicals. A chemical resistance chart is available for determining specific compatibility with a wide variety of chemicals. -
Safety Equipment and Preparation
Always wear the proper protective clothing and gear when working around chemicals and chemical metering pumps. Safety glasses, gloves, and aprons are critical in preventing accidental exposure to dangerous chemicals. -
In Case of Accident
If a chemical spillage occurs, consult the Material Safety Data Sheet (MSDS) for specific instructions regarding the chemical being used. -
Liquids Under Pressure
Liquids under pressure can present a special hazard when a line or seal is punctured resulting in the spraying of chemical many yards away.
Introduction
Congratulations, you have just purchased the world’s most advanced chemical metering pump, the AromaMist pump. The AromaMist pump is a major breakthrough in affordable chemical metering. This instruction manual covers all facets of operation of the AromaMist pump, including unpacking, mounting, electrical and plumbing connection and start-up. Safety, maintenance and repair, warranty and factory information is also provided. Please read this manual completely before proceeding. Observe safety protocols, and heed all warnings and precautions.
WARNING: Steambath equipment can be unique. It is always recommended to have a certified licensed electrician install the AromaMist pump system.
Product Usage Instructions
- Models: AI-1, AI-2, AI-1-4, AI-2-4
- Product: AromaMist Commercial Steam Bath Aroma Bathing Systems
- Installation and Operation Manual Included
Unpacking
The AromaMist pump has been shipped to you as a complete metering package,
ready for installation. If shipping carton shows any signs of damage, notify
the shipping company immediately upon receipt. Shipper cannot be held
responsible for damage from shipping.
AromaMist AI-1-4 / AI-2-4 Pump Package Contents
Installation
-
Location: Choose a suitable location for installing the pump. Select a mounting location convenient to the chemical supply as well as a source of power for the pump. Do not install the pump in a location where the ambient temperature exceeds 120 degrees F (50°C). Higher temperatures will affect the output as well as the useful life of the pump. While the AromaMist pump is suitable for most outdoor installations, do not use the standard poly tubing in direct sunlight. If you must mount pump in direct sunlight or under bright fluorescent lights, consult your distributor or the factory.
-
Electrical: Ensure proper electrical connections following guidelines provided in the manual
-
AromaMist pump models AI-1 and AI-1-4 are 120V AC pumps and have a voltage-regulated internal power supply capable of operating in the range of approximately 95V to 135V AC. Use a power supply of 100 to 120V AC for best results. The 3-wire grounding plug must be used in a 3-wire wall plug (see typical steam solenoid electrical hook up below).
CAUTION: Never remove ground wire from plug. -
AromaMist pump models AI-2 and AI-2-4 are 240V AC pumps and have a voltage regulated internal power supply capable of operating in the range of approximately 195V to 260V AC. Use a power supply of 210 to 250V AC for best results. Pump is supplied without a country-specific plug unless otherwise stated (see typical steam solenoid electrical hook up below).
-
Plumbing: Connect the pump to the plumbing system as instructed in the manual.
-
Piping Connections
The AromaMist pump uses carefully matched components to achieve a predictable metering output. This predictability can only be maintained if all fitting sizes remain unaltered. Do not attempt to reduce tubing size. All tubing connections should be double-checked to insure against leakage. If hazardous chemicals are being pumped, use shielding around discharge tubing.
NOTE: When cutting lengths of tubing for your installation, ensure a clean, square cut. Use short lengths of tubing and as few connections as possible. -
Tubing Nuts
Do not over tighten the tubing connectors. Tighten the fittings no more than 1/4 turn after the fitting contacts the seal. Hand tighten only. Do not use a wrench or pliers as they may damage the fittings. Do not use Teflon tape except on NPT fittings. Be sure to observe applicable local plumbing codes.
WARNING: Clear flexible tubing is not intended for pressurized use. -
Tubing ConnectionsTubing Connections
-
Suction Lift vs. Flooded Suction Applications (models AI-1 and AI-2 only)
-
Suction Lift Installation
Mount the AromaMist pump on the top of or above a chemical tank, not to exceed 5 feet from pump to bottom of tank. -
Flooded Suction
This installation is recommended wherever possible. Priming is easier and loss of prime is reduced. -
Foot Valve Installation (models AI-1 and AI-2 only)
A weight is provided to hold the tubing and foot valve in a vertical position at the bottom of the tank. Do not allow the foot valve to lie horizontally in the chemical container. This defeats the action of the valve and can cause the pump to lose prime. Keep suction tubing reasonably short and avoid high spots or bends. -
Wall Mounting
The fluid end portion (head assembly) of the pump is set up to accommodate mounting of the pump to the chemical container, either as a flooded suction or a suction lift. The pump head must be kept in a vertical position for proper operation. The head can be removed and rotated 90° if needed to keep the inlet and outlet valves in a vertical position. -
Injection Valve Installation
The injection valve is designed to prevent a back flow and to inject chemical into the line. To work properly, this valve must NOT be mounted above the steam line or facing downward into the steam line. One end of the injection valve is 1/2” MNPT. Install this end into the piping system. Use Teflon tape on this fitting only. Connect the pump’s discharge tubing to the opposite end of the injector. Do not use Teflon tape or joint compound on this fitting. Connect tubing between this fitting and the pump discharge fitting at the pump. -
Priming/Bleed Valve Connection (models AI-1 and AI-2 only)
Connect the clear poly tubing to the outlet of the bleed or priming valve. Position the free end of this tube in the chemical container, above the fluid level. -
Injection Valve: Properly install and set up the injection valve for chemical dispensing.
AromaMist AI-1-4 / AI-2-4
Typical Installation: Follow the step-by-step installation guide provided in the manual.
AromaMist Electrical Detail: Detailed electrical setup instructions are outlined in the manual.
Start-Up
- Front Panel Description
Model AI-1 and AI-2 pumps come with the following standard panel features:
Programmable Features | Range of Feature | Default of Feature |
---|---|---|
Strokes Per Minute | 1 to 99 | 10 Strokes Per Minute |
Limit Timer | 0 to 240 Minutes (4 Hours) | 60 Minutes |
On-Delay | 0 to 7200 Seconds (120 Minutes) | 20 Minutes |
Off-Delay | 0 to 480 Minutes (8 Hours) | 4 Hours 40 Minutes |
Restore Factory Defaults | ‘Y’es or ‘N’o | N |
Priming the Pump
-
Pump Priming Mode
Plug in and/or power up the pump at the switch. If pump is in stroke mode, (pump LCD display reads “strokes/min”) press the enter (ENTER) key to initiate the pump priming mode. If pump is in delay mode, (pump LCD display reads “start in: xxx min xx sec”) power down the pump. With pump off and while pressing on the down arrow (↓) key, power on the pump at the switch to initiate pump stroke mode. Press the enter (ENTER) key to initiate the pump priming mode.
Note: Prime mode (125 strokes/minute) will always automatically default to stroke mode after 1 minute. If additional priming time is desired, press the enter (ENTER) key during the stroke mode to initiate further priming. Repeat as necessary until pump priming is complete (see step 2). To exit the pump priming mode, press the enter (ENTER) key to return to the pump stroke mode. -
Priming/Bleed Valve
With pump in priming mode, if fluid begins moving up suction line without hesitation, bleed valve adjustment is not required. If fluid is not moving up suction line, open bleed valve approximately one (1) turn or until fluid begins to move. When fluid level reaches the pump head assembly, close bleed valve allowing fluid to flow through pump head and up to the injector spray head assembly. Once priming is completed, press the enter (ENTER) key to return the pump stroke mode.
NOTE: Do not over-tighten bleed valve as damage may occur.
Adjusting Pump Feed Rate/Strokes per Minute
The AromaMist pump can be adjusted to deliver the exact fluid feed rate
desired. The number of pulses/strokes per minute can be easily adjusted and
displayed on the pump LCD display. Feed rate can be adjusted from 1 to 99
strokes per minute. Depending on application, desired feed rate will vary.
Starting with the factory pre-set 10 strokes per minute, adjust the fluid feed
rate up or down depending on your particular application.
To adjust the feed rate:
- While in the pump stroke mode, press the menu (MENU) button. The LCD display will read “Strokes = 10/min”
- With the blinking cursor on the XX, (the number field) press the up arrow (↑) to increase the strokes/minute or press the down arrow (↓) to decrease the strokes/minute.
- Press the menu (MENU) button to exit the feed rate adjustment mode.
Adjusting the “Limit To”
If the AromaMist pump strokes continuously for more than 60 minutes, the pump
will go into an Alarm mode and stop stroking. Further investigation should be
made as to why the electrical source kept the pump in a stroke mode for a
continuous 60 minutes. If the AromaMist pump is in Alarm mode, turn the power
switch to the off mode and then power it on again to reset the Alarm mode. The
“Limit To” factory default setting is 60 minutes and can be adjusted from 0 to
240 minutes (4 hours). A setting of 0 turns the “Limit To” feature off.
CAUTION: It is not recommended to exceed the factory 60 minute default setting.
To adjust the “Limit To” setting:
- Press the menu (MENU) button.
- Press the enter (ENTER) button to skip over “strokes = xx/min”.
- When the LCD displays L“imit To: XX Min” use theu p arrow (↑) and down arrow (↓) buttons to adjust thed esired Limit To.
- Press menu (MENU) to exit “Limit To” adjustment mode
Adjusting the “On Delay”
On cold equipment start-up, the AromaMist pump is programmed to delay for 20
minutes before it begins to pump fluid. This “On Delay” allows for the time it
takes steam to be generated before fluid is introduced into the steam line.
When the pump is in the “On Delay” mode, the LCD display will read “start in:
xxx min xx sec”, and the keypad is disabled. You may override the “On Delay”
mode by powering the pump on at the switch while simultaneously pressing the
down arrow (↓) key.
Note: The “On Delay” feature is designed to prevent fluid waste.
Adjustable from 0 – 120 minutes, the “On Delay” should be set for one minute
less than the amount of time it takes your equipment to generate steam on a
cold start-up. If you believe an adjustment must be made for your application,
please consult the factory prior to proceeding.
- To adjust the “On Delay” setting:
- Press the menu (MENU) button
- Press the enter (ENTER) button to skip through the Strokes = x/ min
- Press the enter (ENTER) button to skip through the Limit To XX Min
- When the LCD displays “On xxx min xx sec” use the up arrow (↑) and down arrow (↓) buttons to adjust the desired on delay.
- Press menu (MENU) to exit “On Delay” adjustment mode. Page 14
Adjusting the “Off Delay”
The AromaMist pump allows for an “Off Delay” adjustment in order to determine
when the pump startup should be delayed. After initial cold start-up, and
during operation, there will not be an “On Delay” occurrence unless the
AromaMist Pump has been powered off for the amount of time selected in the
“Off Delay” adjustment mode. The factory default is set for 4 hours 40
minutes. The “Off Delay” is adjustable from 0-8 hours (480 minutes).
Note: “Off Delay” settings need only be adjusted if during any normal operating day, the AromaMist Pump will NOT be off for more than 4 hours (240 minutes). If you believe an adjustment must be made for your application, please consult the factory prior to proceeding.
To adjust the “Off Delay” setting:
- Press the menu (MENU) button
- Press the enter (ENTER) button to skip through the Strokes=xx min
- Press the enter (ENTER) button to skip through the Limit To XX Min
- Press the enter (ENTER) button to skip through the “On xxx min xx sec”
- When the LCD displays“ Off x hr xx min” then use the up arrow (↑) and down arrow (↓) buttons to adjust the time accordingly.
- Press menu (MENU) to exit the “Off Delay” adjustment mode.
Restoring Factory Defaults
The AromaMist pump has been programmed with a feature allowing it to be
reset to factory default settings. To clear AromaMist pump memory settings and
return to the factory defaults:
- Press the menu (MENU) button.
- Press the enter (ENTER) button to skip through the “Strokes = xx/min.”
- Press the enter (ENTER) button to skip through the “Limit To XX Min.”
- Press the enter (ENTER) button to skip through the “Limit To.”
- Press the enter (ENTER) button to skip through the “On xxx min xx sec.”
- Press the enter (ENTER) button to skip through the “Off xx hr xx min.”
- When the LCD displays “Restore Defaults? N”, press the up arrow (↑) or down arrow (↓) to change the response to “Y.”
- Press menu (MENU) to exit this mode.
Maintenance
The AromaMist pump has been programmed with a feature allowing it to be
reset to factory default settings.
- Diaphragm Replacement: Instructions for diaphragm replacement are provided in the manual.
- Check Valve Replacement: Guidelines forreplacing suction and discharge check valves are included.
- Liquid End Description: Understand the liquidend components for maintenance purposes.
To clear AromaMist pump memory settings and return to the factory defaults:
- Press the menu (MENU) button.
- Press the enter (ENTER) button to skip through the “Strokes = xx/min.”
- Press the enter (ENTER) button to skip through the “Limit To XX Min.”
- Press the enter (ENTER) button to skip through the “Limit To.”
- Press the enter (ENTER) button to skip through the “On xxx min xx sec.”
- Press the enter (ENTER) button to skip through the “Off xx hr xx min.”
- When the LCD displays “Restore Defaults? N”, press the up arrow (↑) or down arrow (↓) to change the response to “Y.”
- Press menu (MENU) to exit this mode.
NOTE: Tighten pump head screws after pump’s initial week of operation
Diaphragm replacement
- Remove fluid end cover by lightly prying it loose from the fluid end.
- Remove the four screws attaching the fluid end to pump body.
- Remove the fluid end from the pump body.
- Unscrew the diaphragm from the pump shaft in a counter-clockwise direction. Be careful that diaphragm support ring does not fall out.
- Do not allow sharp or abrasive objects to come in contact with pump parts.
- Inspect end of shaft to assure that threads are in good condition. Replace shaft bellows if necessary. No further disassembly is recommended.
- Screw new diaphragm onto pump shaft until it bottoms out on shoulder of shaft. It is not necessary to tighten further.
- Replace fluid end. Make sure that screws are evenly tightened.
- Reconnect plumbing and power. Prime the pump.
Check Valve Replacement, Suction
NOTE: When installing check valves, remember that the seats are always
installed at the bottom.
- Disconnect suction tubing from pump.
- Remove fluid end per previous procedure.
- Unscrew suction fitting from pump head.
- Remove check valve from suction fitting and replace.
- Remove O-ring from cavity in fluid end.
- Remove check valve from suction side of pump and replace.
- Install new O-ring in suction cavity of fluid end.
- Replace suction fitting with check valve in fluid end.
- Replace fluid end. Make sure that screws are evenly tightened.
- Reconnect plumbing and power. Prime the pump.
Check Valve Replacement, Discharge.
- Disconnect discharge tubing from pump.
- Remove fluid end per previous procedure.
- Unscrew discharge fitting from pump head.
- Remove check valve from discharge fitting and replace.
- Remove O-ring from cavity in fluid end.
- Remove check valve from discharge side of pump and replace. Some resistance may be encountered when removing this valve from the fluid end. If so, insert an abrasion free object (the inner tube from a ballpoint pen, will work) in the face of the pump head to push it out.
- Install new O-ring in discharge cavity of fluid end.
- Replace discharge fitting with check valve in fluid end.
- Replace fluid end. Make sure that screws are evenly tightened.
- Reconnect plumbing and power. Prime the pump.
Liquid End Diagram
Troubleshooting
If you encounter issues with the pump, refer to the troubleshooting section in
the manual for guidance on identifying and resolving common problems.
Problem | Cause | Remedy |
---|
Pump does not achieve or maintain prime
| ****
Air trapped in suction line
Foot valve contaminated or improperly installed
Excessive lift
Suction fittings not properly tightened
Worn or contaminated check valves
Kink or pinch in suction tube
Low chemical level
| ****
Straighten suction line so as to eliminate high spots.
Inspect foot valve screen and assure that foot valve is in a vertical position below fluid level.
Maximum suction lift is 5 feet with water or fluids of similar specific gravity; less with heavier liquids such as acids. Mount pump in a lower position relative to the chemical container.
Check fittings. Overtightening may cause restriction. Conversely, if any leakage occurs, pump will suck air and fail to prime.
Inspect check valves in fluid end for cleanliness. Clean or replace as necessary.
Inspect suction tube through its full length to assure that there are no kinks or other restrictions.
Move any objects or equipment which impinges upon suction tube or reroute as required to assure a smooth transition from foot valve to pump.
Check fluid level in chemical supply tank.
Insufficient fluid
| ****
Worn or contaminated check valves
Obstruction in suction line
Clogged foot valve screen
Diaphragm worn or torn
Electronic failure
| ****
Inspect, clean or replace as necessary.
Check suction line for obstructions, clogging, kinks or pinch points.
Clean or replace foot valve screen.
Replace diaphragm, making sure that it is screwed on fully to shoulder of shaft.
Consult dealer or factory.
Problem | Cause | Remedy |
---|
Excessive fluid
| ****
Failure or lack of anti- siphon valve
Excessive stroke rate Improper stroke length
| ****
Inspect or add anti-siphon valve. This is caused when system is in a vacuum condition or valve in delivery applications with flooded suction which feeds systems at very low pressures.
Lower the stroke rate if adjustable on your pump.
Consult dealer or factory.
Pump will not pump
| ****
System pressure too high
Diaphragm improperly installed
Check valves worn or clogged
| ****
Check system pressure to assure that it is within system rated parameters of the pressure.
Make sure that diaphragm is screwed fully onto shaft.
Clean or replace as required.
Pump will not run or not plugged in
| ****
Pump not turned on or not plugged in
Electronic failure
| ****
Check outlet with meter to assure that 95-135 VAC is present on 120V systems, 195-260 VAC is present on 240V systems and that power supply cord is in good condition and plugged in.
Consult dealer or factory.
Excessive noise
| Pump not primed No output pressure| ****
Prime pump.
Add an anti-siphon valve to provide 25 PSI restriction on pump discharge.
Product Warranty
Limited Lifetime Warranty
If you should experience a problem with an AromaMist pump system, simply call
(800) 97-STEAM (78326), and tell us your model and serial number of the pump
and problem. If we can’t get your pump working over the phone, a fully
warranted replacement will be shipped out the same day on 30-day memo billing.
We will ask for a P.O. number for tracking purposes on the replacement unit
which will only be used if the non-functioning pump is not returned. It is
critical for us to get the old pump back for engineering evaluation as we
continually strive to enhance our products. Accurate Industries warrants the
AromaMist Essential Oil Delivery System of its manufacture to be free of
defects in material or workmanship for the life of its use provided solely
AromaMist essential oils are used; otherwise, liability under this policy
extends for one (1) year from the date of purchase. Liability is limited to
repair or replacement of any failed equipment or part proven defective in
material or workmanship upon manufacturer examination. Removal and
installation costs are not included in this warranty. Manufacturer’s liability
should never exceed the selling price of equipment or part in question.
Accurate Industries disclaims all liability for damage caused by its products
by improper installation, maintenance, use or attempts to operate products
beyond their intended functionality, intentionally or otherwise, or any
unauthorized repair. Accurate Industries, Inc. is not responsible for damages,
injuries or expense incurred through the use of its products. The above
warranty applies in lieu of other warranties either expressed or implied. No
agent of ours is authorized to provide any warranty other than the above.
(Typical Installation)
If AromaMist metering pumps are designed to work with AromaMist oils only. you have recieved this page, you have purchased the AromaMist Aroma Oil Pump System with the optional Aroma Tank. This page replaces the installation section IV, letter F on page 7 of the enclosed installation manual. While following the provided step-by-step AromaMist Pump Installation detail beginning on page 7, ignore points 1-11 and 14-15, as they do not pertain to an aroma tank installation.
FAQ
Q: Is it necessary to have a certified electrician install the AromaMist
pump system?
A: Yes, it is recommended to have a certified licensed electrician install the
system due to the unique nature of steambath equipment.
Distributed by
Accurate Industries
www.AccurateIndustries.com
847-465-8990
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>