AROMAMIST AI-1 Bathing System with 5 Gallon Tank Instruction Manual

September 20, 2024
AROMAMIST

AI-1 Bathing System with 5 Gallon Tank

“`html

Product Information

Specifications

  • Models: AI-1, AI-2, AI-1-4, AI-2-4
  • Type: Commercial Steam Bath Aroma Bathing Systems
  • Features: Advanced chemical metering pump
  • Compatibility: Works with most liquid chemicals
  • Warranty: Limited Lifetime Warranty

Product Usage Instructions

1. Unpacking

The AromaMist pump comes as a complete metering package. Check
for any shipping damage and contact the shipping company if
needed.

2. Safety Considerations

Always wear proper protective clothing and gear when working
with chemicals and chemical metering pumps. Refer to the Material
Safety Data Sheet (MSDS) in case of accidents.

3. Installation

a. Location: Choose a suitable location for
installation.

b. Electrical: Have a certified electrician
install the AromaMist pump system.

c. Plumbing: Ensure proper plumbing
connections.

d. Injection Valve: Install the injection valve
correctly.

e. Typical Installation: Follow the provided
guidelines for installation.

f. Electrical Detail: Detailed electrical
installation instructions are provided.

4. Maintenance

a. Diaphragm Replacement: Instructions for
replacing the diaphragm are provided.

b. Check Valve Replacement, Suction: Guidance
on replacing the suction check valve.

c. Check Valve Replacement, Discharge:
Instructions for replacing the discharge check valve.

d. Liquid End Description: Details about the
liquid end are provided for maintenance purposes.

5. Troubleshooting

Refer to the troubleshooting section in the manual for
assistance with common issues.

Frequently Asked Questions (FAQ)

Q: Can the AromaMist pump work with all types of liquid

chemicals?

A: The pump is designed to work with most liquid chemicals, but
it is recommended to check the chemical compatibility chart for
specific details.

Q: What should I do in case of a chemical spillage?

A: Consult the Material Safety Data Sheet (MSDS) for specific
instructions on handling chemical spillages.

“`

Model: AI-1 / AI-2

Model: AI-1-4 / AI-2-4

Installation and Operation Manual

AromaMist AI-1 / AI-2 / AI-1-4 / AI-2-4 Commercial Steam Bath Aroma Bathing Systems
Installation and Operation Manual Table of Contents
I. Introduction…………………………………………………. 3
II. Unpacking…………………………………………………… 3
III. Safety Considerations……………………………………… 3 Pump Package Contents………………………………….. 4
IV. Installation a. Location……………………………………………………. 5 b. Electrical…………………………………………………… 5 c. Plumbing…………………………………………………… 6 d. Injection Valve…………………………………………….. 8 e. Typical Installation………………………………………… 10 f. Electrical Detail……………………………………………. 10
V. Start-up a. Front Panel Description…………………………………. 11 b. Priming the Pump………………………………………… 12 c. Adjusting Pump Feed Rate……………………………… 13 d. Adjusting the Limit To……………………………………. 13 e. Adjusting the On Delay………………………………….. 14 f. Adjusting the Off Delay………………………………….. 15 g. Restoring Factory Defaults……………………………… 16
VI. Maintenance a. Diaphragm Replacement………………………………… 17 b. Check Valve Replacement, Suction……………………. 18 c. Check Valve Replacement, Discharge…………………. 18 d. Liquid End Description……………………………………. 19
VII. Troubleshooting………………………………………………. 20
VIII. Limited Lifetime Warranty……………………………………. 22
Page 2

I. Introduction
Congratulations, you have just purchased the world’s most advanced chemical metering pump, the AromaMist pump. The AromaMist pump is a major breakthrough in affordable chemical metering.
This instruction manual covers all facets of operation of the AromaMist pump, including unpacking, mounting, electrical and plumbing connection and start- up. Safety, maintenance and repair, warranty and factory information is also provided. Please read this manual completely before proceeding.
Observe safety protocols, and heed all warnings and precautions.
WARNING: Steambath equipment can be unique. It is always recommended to have a certified licensed
electrician install the AromaMist pump system.
II. Unpacking
The AromaMist pump has been shipped to you as a complete metering package, ready for installation. If shipping carton shows any signs of damage, notify the shipping company immediately upon receipt. Shipper cannot be held responsible for damage from shipping.
III. Safety Considerations
NOTE: All AromaMist pumps are primed with water before leaving the factory.
A. Chemical Compatibility
AromaMist metering pumps are designed to work with most liquid chemicals. A chemical resistance chart is available for determining specific compatibility with a wide variety of chemicals.
B. Safety Equipment and Preparation
Always wear the proper protective clothing and gear when working around chemicals and chemical metering pumps. Safety glasses, gloves, and aprons are critical in preventing accidental exposure to dangerous chemicals.
Page: 3

C. In Case of Accident
If a chemical spillage occurs, consult the Material Safety Data Sheet (MSDS) for specific instructions regarding the chemical being used.
D. Liquids Under Pressure
Liquids under pressure can present a special hazard when a line or seal is punctured resulting in the spraying of chemical many yards away.
AromaMist AI-1-4 / AI-2-4 Pump Package Contents

Item

Description

Stock Code

A.

Pump Only (110/120v)

Pump Only (220/240v)

AROMAMIST019 AROMAMIST020

B.

3/8″ Discharge Tubing 20′

AROMAMIST001

Foot Valve (Models AI-1 and AI-2 only, not shown)

AROMAMIST002

Ceramic Weight (Models AI-1 and AI-2 only, not shown) AROMAMIST003

C.

Injection Valve

AROMAMIST004

D.

Electrical Box

AROMAMIST005

E.

Electrical Outlet

110/120v (AI-1)

AROMAMIST006

220/240v (AI-2)

AROMAMIST007

F.

Electrical Cover Plate

AROMAMIST008

G.

Electrical Box Connector

AROMAMIST009

H.

Brass T

AROMAMIST010

I.

Brass Spray Nozzle

AROMAMIST011

Brass ¼” x 4″ Nipple

AROMAMIST012

Brass Reducer

AROMAMIST013

J.

5 Gallon Tank (Option)

AROMAMIST024

K.

Mounting Bracket

L.

  • Mounting hardware

AROMAMIST025

(* Included with mounting bracket)

Page 4

IV. Installation
A. Location
Select a mounting location convenient to the chemical supply as well as a source of power for the pump. Do not install the pump in a location where the ambient temperature exceeds 120 degrees F (50°C). Higher temperatures will affect the output as well as the useful life of the pump. While the AromaMist pump is suitable for most outdoor installations, do not use the standard poly tubing in direct sunlight. If you must mount pump in direct sunlight or under bright fluorescent lights, consult your distributor or the factory.
B. Electrical
1. AromaMist pump models AI-1 and AI-1-4 are 120V AC pumps and have a voltage regulated internal power supply capable of operating in the range of approximately 95V to 135V AC. Use a power supply of 100 to 120V AC for best results. The 3-wire grounding plug must be used in a 3-wire wall plug (see typical steam solenoid electrical hook up below).
CAUTION: Never remove ground wire from plug.
2. AromaMist pump models AI-2 and AI-2-4 are 240V AC pumps and have a voltage regulated internal power supply capable of operating in the range of approximately 195V to 260V AC. Use a power supply of 210 to 250V AC for best results. Pump is supplied without a country specific plug unless otherwise stated (see typical steam solenoid electrical hook up below).
Page 5

C. Plumbing

1. Piping Connections
The AromaMist pump uses carefully matched components to achieve a predictable metering output. This predictability can only be maintained if all fitting sizes remain unaltered. Do not attempt to reduce tubing size. All tubing connections should be double-checked to insure against leakage. If hazardous chemicals are being pumped, use shielding around discharge tubing.

NOTE:

When cutting lengths of tubing for your installation, ensure a clean, square cut. Use short lengths of tubing and as few connections as possible.

2. Tubing Nuts
Do not over tighten the tubing connectors. Tighten the fittings no more than 1/4 turn after the fitting contacts the seal. Hand tighten only. Do not use a wrench or pliers as they may damage the fittings. Do not use Teflon tape except on NPT fittings. Be sure to observe applicable local plumbing codes.

WARNING: Clear flexible tubing is not intended for pressurized use. 3. Tubing Connections

Page 6

4. Suction Lift vs. Flooded Suction Applications (models AI-1 and AI-2 only) Suction Lift Installation Mount the AromaMist pump on the top of or above a chemical tank, not to exceed 5 feet from pump to bottom of tank. Flooded Suction This installation is recommended wherever possible. Priming is easier and loss of prime is reduced.
5. Foot Valve Installation (models AI-1 and AI-2 only) A weight is provided to hold the tubing and foot valve in a vertical position at the bottom of the tank. Do not allow the foot valve to lie horizontally in the chemical container. This defeats the action of the valve and can cause the pump to lose prime. Keep suction tubing reasonably short and avoid high spots or bends.
Page 7

6. Wall Mounting
The fluid end portion (head assembly) of the pump is set up to accommodate mounting of the pump to the chemical container, either as a flooded suction or a suction lift. The pump head must be kept in a vertical position for proper operation. The head can be removed and rotated 90° if needed to keep the inlet and outlet valves in a vertical position.
7. Injection Valve Installation The injection valve is designed to prevent a back flow and to inject chemical into the line. To work properly, this valve must NOT be mounted above the steam line or facing downward into the steam line. One end of the injection valve is 1/2″ MNPT. Install this end into the piping system. Use Teflon tape on this fitting only. Connect the pump’s discharge tubing to the opposite end of the injector. Do not use Teflon tape or joint compound on this fitting. Connect tubing between this fitting and the pump discharge fitting at the pump.
8. Priming/Bleed Valve Connection (models AI-1 and AI-2 only) Connect the clear poly tubing to the outlet of the bleed or priming valve. Position the free end of this tube in the chemical container, above the fluid level.
Page 7

AromaMist AI-1-4 / AI-2-4
Typical Installation
AromaMist Electrical Detail
Page 9

V. Start-Up
A. Front Panel Description
Model AI-1 and AI-2 pumps come with the following standard panel features:

Programmable Features Strokes Per Minute Limit Timer On-Delay Off-Delay Restore Factory Defaults

Range of Feature 1 to 99 0 to 240 Minutes (4 Hours) 0 to 7200 Seconds (120 Minutes) 0 to 480 Minutes (8 Hours) Y’es orN’o

Default of Feature 10 Strokes Per Minute 60 Minutes 20 Minutes 4 Hours 40 Minutes N

Page 10

B. Priming the Pump
1.Pump Priming Mode Plug in and/or power up the pump at the switch. If pump is in stroke mode, (pump LCD display reads “strokes/min”) press the enter (ENTER) key to initiate the pump priming mode. If pump is in delay mode, (pump LCD display reads “start in: xxx min xx sec”) power down the pump. With pump off and while pressing on the down arrow () key, power on the pump at the switch to initiate pump stroke mode. Press the enter (ENTER) key to initiate the pump priming mode. Note: Prime mode (125 strokes/minute) will always automatically default to stroke mode after 1 minute. If additional priming time is desired, press the enter (ENTER) key during the stroke mode to initiate further priming. Repeat as necessary until pump priming is complete (see step 2). To exit the pump priming mode, press the enter (ENTER) key to return to the pump stroke mode.
2.Priming/Bleed Valve With pump in priming mode, if fluid begins moving up suction line without hesitation, bleed valve adjustment is not required. If fluid is not moving up suction line, open bleed valve approximately one (1) turn or until fluid begins to move. When fluid level reaches the pump head assembly, close bleed valve allowing fluid to flow through pump head and up to the injector spray head assembly. Once priming is completed, press the enter (ENTER) key to return the pump stroke mode. NOTE: Do not over-tighten bleed valve as damage may occur.
Page 11

C. Adjusting Pump Feed Rate/Strokes per Minute
The AromaMist pump can be adjusted to deliver the exact fluid feed rate desired. The number of pulses/strokes per minute can be easily adjusted and displayed on the pump LCD display. Feed rate can be adjusted from 1 to 99 strokes per minute. Depending on application, desired feed rate will vary. Starting with the factory pre-set 10 strokes per minute, adjust the fluid feed rate up or down depending on your particular application.
To adjust the feed rate: · While in the pump stroke mode, press the menu (MENU) button. The LCD display will read “Strokes = 10/min”
· With the blinking cursor on the XX, (the number field) press the up arrow () to increase the strokes/minute or press the down arrow () to decrease the strokes/minute.
· Press the menu (MENU) button to exit the feed rate adjustment mode.
D. Adjusting the “Limit To”
If the AromaMist pump strokes continuously for more than 60 minutes, the pump will go into an Alarm mode and stop stroking. Further investigation should be made as to why the electrical source kept the pump in a stroke mode for a continuous 60 minutes.
If the AromaMist pump is in Alarm mode, turn the power switch to the off mode and then power it on again to reset the Alarm mode. The “Limit To” factory default setting is 60 minutes and can be adjusted from 0 to 240 minutes (4 hours). A setting of 0 turns the “Limit To” feature off.
CAUTION: It is not recommended to exceed the factory 60 minute default setting.
To adjust the “Limit To” setting:
· Press the menu (MENU) button.
· Press the enter (ENTER) button to skip over “strokes = xx/min”.
Page 12

· When the LCD displays “Limit To: XX Min” use the up arrow () and down arrow () buttons to adjust the desired Limit To.
· Press menu (MENU) to exit “Limit To” adjustment mode
E. Adjusting the “On Delay”
On cold equipment start-up, the AromaMist pump is programmed to delay for 20 minutes before it begins to pump fluid. This “On Delay” allows for the time it takes steam to be generated before fluid is introduced into the steam line. When the pump is in the “On Delay” mode, the LCD display will read “start in: xxx min xx sec”, and the keypad is disabled.
You may override the “On Delay” mode by powering the pump on at the switch while simultaneously pressing the down arrow () key.
Note: The “On Delay” feature is designed to prevent fluid waste.
Adjustable from 0 – 120 minutes, the “On Delay” should be set for one minute less than the amount of time it takes your equipment to generate steam on a cold start-up. If you believe an adjustment must be made for your application, please consult the factory prior to proceeding.
To adjust the “On Delay” setting:
· Press the menu (MENU) button
· Press the enter (ENTER) button to skip through the Strokes = x/ min
· Press the enter (ENTER) button to skip through the Limit To XX Min
· When the LCD displays “On xxx min xx sec” use the up arrow () and down arrow () buttons to adjust the desired on delay.
· Press menu (MENU) to exit “On Delay” adjustment mode.
Page 13

F. Adjusting the “Off Delay”
The AromaMist pump allows for an “Off Delay” adjustment in order to determine when the pump startup should be delayed. After initial cold start-up, and during operation, there will not be an “On Delay” occurrence unless the AromaMist Pump has been powered off for the amount of time selected in the “Off Delay” adjustment mode. The factory default is set for 4 hours 40 minutes. The “Off Delay” is adjustable from 0-8 hours (480 minutes). Note: “Off Delay” settings need only be adjusted if during any normal operating day, the AromaMist Pump will NOT be off for more than 4 hours (240 minutes). If you believe an adjustment must be made for your application, please consult the factory prior to proceeding.
To adjust the “Off Delay” setting: · Press the menu (MENU) button · Press the enter (ENTER) button to skip through the Strokes=xx min · Press the enter (ENTER) button to skip through the Limit To XX Min · Press the enter (ENTER) button to skip through the “On xxx min xx sec” · When the LCD displays “Off x hr xx min” then use the up arrow () and down arrow () buttons to adjust the time accordingly. · Press menu (MENU) to exit the “Off Delay” adjustment mode.
Page 14

G. Restoring Factory Defaults
The AromaMist pump has been programmed with a feature allowing it to be reset to factory default settings. To clear AromaMist pump memory settings and return to the factory defaults:
· Press the menu (MENU) button. · Press the enter (ENTER) button to skip through the “Strokes = xx/min.” · Press the enter (ENTER) button to skip through the “Limit To XX Min.” · Press the enter (ENTER) button to skip through the “Limit To.” · Press the enter (ENTER) button to skip through the “On xxx min xx sec.” · Press the enter (ENTER) button to skip through the “Off xx hr xx min.” · When the LCD displays “Restore Defaults? N”, press the up arrow ()
or down arrow () to change the response to “Y.” · Press menu (MENU) to exit this mode.
VI. Maintenance
The AromaMist pump is designed for long service life with minimum maintenance. If for any reason maintenance is necessary or desirable, the AromaMist pump is easily maintained. Before any maintenance or service is performed, observe the following precautions:
1. Disconnect the AromaMist pump from power source. 2. Drain chemical from discharge tubing. 3. Disconnect discharge tubing from pump. 4. If the AromaMist pump is used in a flooded suction application, remove
foot valve from chemical container. 5. Observe relevant safety protocols when handling parts which have been in
contact with hazardous chemicals.
Page 15

NOTE: Tighten pump head screws after pump’s initial week of operation.
1. Remove fluid end cover by lightly prying it loose from the fluid end. 2. Remove the four screws attaching the fluid end to pump body. 3. Remove the fluid end from the pump body. 4. Unscrew the diaphragm from the pump shaft in a counter-clockwise
direction. Be careful that diaphragm support ring does not fall out. 5. Do not allow sharp or abrasive objects to come in contact with pump parts. 6. Inspect end of shaft to assure that threads are in good condition.
Replace shaft bellows if necessary. No further disassembly is recommended. 7. Screw new diaphragm onto pump shaft until it bottoms out on shoulder of shaft. It is not necessary to tighten further. 8. Replace fluid end. Make sure that screws are evenly tightened. 9. Reconnect plumbing and power. Prime the pump.
Page 16

B. Check Valve Replacement, Suction
NOTE: When installing check valves, remember that the seats are always installed at the bottom.
1. Disconnect suction tubing from pump. 2. Remove fluid end per previous procedure. 3. Unscrew suction fitting from pump head. 4. Remove check valve from suction fitting and replace. 5. Remove O-ring from cavity in fluid end. 6. Remove check valve from suction side of pump and replace. 7. Install new O-ring in suction cavity of fluid end. 8. Replace suction fitting with check valve in fluid end. 9. Replace fluid end. Make sure that screws are evenly tightened. 10. Reconnect plumbing and power. Prime the pump.
C. Check Valve Replacement, Discharge.
1. Disconnect discharge tubing from pump. 2. Remove fluid end per previous procedure. 3. Unscrew discharge fitting from pump head. 4. Remove check valve from discharge fitting and replace. 5. Remove O-ring from cavity in fluid end. 6. Remove check valve from discharge side of pump and replace.
Some resistance may be encountered when removing this valve from the fluid end. If so, insert an abrasion free object (the inner tube from a ballpoint pen, will work) in the face of the pump head to push it out. 7. Install new O-ring in discharge cavity of fluid end.
Page 17

8. Replace discharge fitting with check valve in fluid end. 9. Replace fluid end. Make sure that screws are evenly tightened. 10. Reconnect plumbing and power. Prime the pump.
D. Liquid End Diagram
10 13

6 9 1 14
2
13 12

7 3
4 8

Item Description

1

Complete Head Kit (includes)

2

Pump Head *

3

Pump Diaphragm *

4

Support Ring *

5

Shaft Seal *

6

Head Bolts *

  • Not sold separately

57

Discharge Valve

8

Suction Valve

9

Priming Valve

10 Injection Valve

11 Foot Valve

12 Ceramic Weight

13 Discharge & Suction Tubing

14 Priming Tubing

**Brass Check Valve

Stock Code AROMAMIST014
AROMAMIST015 AROMAMIST016 AROMAMIST017 AROMAMIST004 AROMAMIST002 AROMAMIST003 AROMAMIST001 AROMAMIST018 AROMAMIST027

**Tank Plug

AROMAMIST029

11 ** Items not shown and exclusive to aroma tank on model AI-1-4 and AI-2-4 pump systems.

Page 18

VII. Troubleshooting

Problem
Pump does not achieve or maintain prime
Insufficient fluid

Cause

Remedy

Air trapped in suction line

Straighten suction line so as to eliminate high spots.

Foot valve contaminated Inspect foot valve screen and assure that foot

or improperly installed

valve is in a vertical position below fluid level.

Excessive lift

Maximum suction lift is 5 feet with water or fluids of similar specific gravity; less with heavier liquids such as acids. Mount pump in a lower position relative to the chemical container.

Suction fittings not properly tightened

Check fittings. Overtightening may cause
restriction. Conversely, if any leakage occurs, pump will suck air and fail to prime.

Worn or contaminated check valves

Inspect check valves in fluid end for cleanliness. Clean or replace as necessary.

Kink or pinch in suction tube

Inspect suction tube through its full length to assure that there are no kinks or other restrictions.

Move any objects or equipment which impinges upon suction tube or reroute as required to assure a smooth transition from foot valve to pump.

Low chemical level

Check fluid level in chemical supply tank.

Worn or contaminated check valves

Inspect, clean or replace as necessary.

Obstruction in suction line Check suction line for obstructions, clogging, kinks or pinch points.

Clogged foot valve screen

Clean or replace foot valve screen.

Diaphragm worn or torn

Replace diaphragm, making sure that it is screwed on fully to shoulder of shaft.

Electronic failure

Consult dealer or factory.

Page 19

Problem
Excessive fluid
Pump will not pump
Pump will not run or not plugged in Excessive noise

Cause

Remedy

Failure or lack of antisiphon valve

Inspect or add anti-siphon valve. This is caused when system is in a vacuum condition or valve in delivery applications with flooded suction which feeds systems at very low pressures.

Excessive stroke rate

Lower the stroke rate if adjustable on your pump.

Improper stroke length

Consult dealer or factory.

System pressure too high Check system pressure to assure that it is within system rated parameters of the pressure.

Diaphragm improperly installed

Make sure that diaphragm is screwed fully onto shaft.

Check valves worn or clogged

Clean or replace as required.

Pump not turned on or not plugged in

Check outlet with meter to assure that 95-135 VAC is present on 120V systems, 195-260 VAC is present on 240V systems and that power supply cord is in good condition and plugged in.

Electronic failure

Consult dealer or factory.

Pump not primed

Prime pump.

No output pressure

Add an anti-siphon valve to provide 25 PSI restriction on pump discharge.

Distributed by Accurate Industries www.AccurateIndustries.com
847-465-8990
Page 20

AIM4-1011

VIII. Product Warranty
AromaMist
Limited Lifetime Warranty
If you should experience a problem with an AromaMist pump system, simply call (800) 97-STEAM (78326), and tell us your model and serial number of the pump and problem.
If we can’t get your pump working over the phone, a fully warranted replacement will be shipped out the same day on 30-day memo billing. We will ask for a P.O. number for tracking purposes on the replacement unit which will only be used if the non-functioning pump is not returned. It is critical for us to get the old pump back for engineering evaluation as we continually strive to enhance our products.
A c c u r a t e I n d u s t r i e s warrants the AromaMist Essential Oil Delivery System of its manufacture to be free of defects in material or workmanship for the life of its use provided solely AromaMist essential oils are used; otherwise, liability under this policy extends for one (1) year from the date of purchase. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer examination. Removal and installation costs are not included in this warranty. Manufacturer’s liability should never exceed the selling price of equipment or part in question.
A c c u r a t e I n d u s t r i e s disclaims all liability for damage caused by its products by improper installation, maintenance, use or attempts to operate products beyond their intended functionality, intentionally or otherwise, or any unauthorized repair. Accurate Industries, Inc. is not responsible for damages, injuries or expense incurred through the use of its products.
The above warranty applies in lieu of other warranties either expressed or implied. No agent of ours is authorized to provide any warranty other than the above.
Page 21

1/2″ Brass T
3-Function Valve
Steam Line Priming Tube
Discharge Tubing

AROMAMIST TANK OPTION
(Typical Installation)

Steam Outlet (simulation)

Grounded 120V AC Outlet

Power Supply Outlet Module
AromaMist Switch Cable

Tank Lid

Aroma Tank

Aroma Pump

Bleed Valve

Steam Generator

Suction Tubing

Tank Shut-off Valve

Power Cord (110V AC)
AromaMist Switch

If AromaMist metering pumps are designed to work with AromaMist oils only. you have recieved this page, you have purchased the AromaMist Aroma Oil Pump System with the optional Aroma Tank.
This page replaces the installation section IV, letter F on page 7 of the enclosed installation manual. While following the provided step-by-step AromaMist Pump Installation detail beginning on page 7, ignore points 1-11 and 14-15, as they do not pertain to an aroma tank installation.
AIM5-507

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals