AROMAMIST AI-1 Bathing System with 5 Gallon Tank Instruction Manual
- September 20, 2024
- AROMAMIST
Table of Contents
AI-1 Bathing System with 5 Gallon Tank
“`html
Product Information
Specifications
- Models: AI-1, AI-2, AI-1-4, AI-2-4
- Type: Commercial Steam Bath Aroma Bathing Systems
- Features: Advanced chemical metering pump
- Compatibility: Works with most liquid chemicals
- Warranty: Limited Lifetime Warranty
Product Usage Instructions
1. Unpacking
The AromaMist pump comes as a complete metering package. Check
for any shipping damage and contact the shipping company if
needed.
2. Safety Considerations
Always wear proper protective clothing and gear when working
with chemicals and chemical metering pumps. Refer to the Material
Safety Data Sheet (MSDS) in case of accidents.
3. Installation
a. Location: Choose a suitable location for
installation.
b. Electrical: Have a certified electrician
install the AromaMist pump system.
c. Plumbing: Ensure proper plumbing
connections.
d. Injection Valve: Install the injection valve
correctly.
e. Typical Installation: Follow the provided
guidelines for installation.
f. Electrical Detail: Detailed electrical
installation instructions are provided.
4. Maintenance
a. Diaphragm Replacement: Instructions for
replacing the diaphragm are provided.
b. Check Valve Replacement, Suction: Guidance
on replacing the suction check valve.
c. Check Valve Replacement, Discharge:
Instructions for replacing the discharge check valve.
d. Liquid End Description: Details about the
liquid end are provided for maintenance purposes.
5. Troubleshooting
Refer to the troubleshooting section in the manual for
assistance with common issues.
Frequently Asked Questions (FAQ)
Q: Can the AromaMist pump work with all types of liquid
chemicals?
A: The pump is designed to work with most liquid chemicals, but
it is recommended to check the chemical compatibility chart for
specific details.
Q: What should I do in case of a chemical spillage?
A: Consult the Material Safety Data Sheet (MSDS) for specific
instructions on handling chemical spillages.
“`
Model: AI-1 / AI-2
Model: AI-1-4 / AI-2-4
Installation and Operation Manual
AromaMist AI-1 / AI-2 / AI-1-4 / AI-2-4 Commercial Steam Bath Aroma Bathing
Systems
Installation and Operation Manual Table of Contents
I. Introduction…………………………………………………. 3
II. Unpacking…………………………………………………… 3
III. Safety Considerations……………………………………… 3 Pump Package
Contents………………………………….. 4
IV. Installation a. Location……………………………………………………. 5 b.
Electrical…………………………………………………… 5 c. Plumbing…………………………………………………… 6 d.
Injection Valve…………………………………………….. 8 e. Typical Installation…………………………………………
10 f. Electrical Detail……………………………………………. 10
V. Start-up a. Front Panel Description…………………………………. 11 b. Priming the
Pump………………………………………… 12 c. Adjusting Pump Feed Rate……………………………… 13 d.
Adjusting the Limit To……………………………………. 13 e. Adjusting the On
Delay………………………………….. 14 f. Adjusting the Off Delay………………………………….. 15 g.
Restoring Factory Defaults……………………………… 16
VI. Maintenance a. Diaphragm Replacement………………………………… 17 b. Check Valve
Replacement, Suction……………………. 18 c. Check Valve Replacement, Discharge………………….
18 d. Liquid End Description……………………………………. 19
VII. Troubleshooting………………………………………………. 20
VIII. Limited Lifetime Warranty……………………………………. 22
Page 2
I. Introduction
Congratulations, you have just purchased the world’s most advanced chemical
metering pump, the AromaMist pump. The AromaMist pump is a major breakthrough
in affordable chemical metering.
This instruction manual covers all facets of operation of the AromaMist pump,
including unpacking, mounting, electrical and plumbing connection and start-
up. Safety, maintenance and repair, warranty and factory information is also
provided. Please read this manual completely before proceeding.
Observe safety protocols, and heed all warnings and precautions.
WARNING: Steambath equipment can be unique. It is always recommended to have a
certified licensed
electrician install the AromaMist pump system.
II. Unpacking
The AromaMist pump has been shipped to you as a complete metering package,
ready for installation. If shipping carton shows any signs of damage, notify
the shipping company immediately upon receipt. Shipper cannot be held
responsible for damage from shipping.
III. Safety Considerations
NOTE: All AromaMist pumps are primed with water before leaving the factory.
A. Chemical Compatibility
AromaMist metering pumps are designed to work with most liquid chemicals. A
chemical resistance chart is available for determining specific compatibility
with a wide variety of chemicals.
B. Safety Equipment and Preparation
Always wear the proper protective clothing and gear when working around
chemicals and chemical metering pumps. Safety glasses, gloves, and aprons are
critical in preventing accidental exposure to dangerous chemicals.
Page: 3
C. In Case of Accident
If a chemical spillage occurs, consult the Material Safety Data Sheet (MSDS)
for specific instructions regarding the chemical being used.
D. Liquids Under Pressure
Liquids under pressure can present a special hazard when a line or seal is
punctured resulting in the spraying of chemical many yards away.
AromaMist AI-1-4 / AI-2-4 Pump Package Contents
Item
Description
Stock Code
A.
Pump Only (110/120v)
Pump Only (220/240v)
AROMAMIST019 AROMAMIST020
B.
3/8″ Discharge Tubing 20′
AROMAMIST001
Foot Valve (Models AI-1 and AI-2 only, not shown)
AROMAMIST002
Ceramic Weight (Models AI-1 and AI-2 only, not shown) AROMAMIST003
C.
Injection Valve
AROMAMIST004
D.
Electrical Box
AROMAMIST005
E.
Electrical Outlet
110/120v (AI-1)
AROMAMIST006
220/240v (AI-2)
AROMAMIST007
F.
Electrical Cover Plate
AROMAMIST008
G.
Electrical Box Connector
AROMAMIST009
H.
Brass T
AROMAMIST010
I.
Brass Spray Nozzle
AROMAMIST011
Brass ¼” x 4″ Nipple
AROMAMIST012
Brass Reducer
AROMAMIST013
J.
5 Gallon Tank (Option)
AROMAMIST024
K.
Mounting Bracket
L.
- Mounting hardware
AROMAMIST025
(* Included with mounting bracket)
Page 4
IV. Installation
A. Location
Select a mounting location convenient to the chemical supply as well as a
source of power for the pump. Do not install the pump in a location where the
ambient temperature exceeds 120 degrees F (50°C). Higher temperatures will
affect the output as well as the useful life of the pump. While the AromaMist
pump is suitable for most outdoor installations, do not use the standard poly
tubing in direct sunlight. If you must mount pump in direct sunlight or under
bright fluorescent lights, consult your distributor or the factory.
B. Electrical
1. AromaMist pump models AI-1 and AI-1-4 are 120V AC pumps and have a voltage
regulated internal power supply capable of operating in the range of
approximately 95V to 135V AC. Use a power supply of 100 to 120V AC for best
results. The 3-wire grounding plug must be used in a 3-wire wall plug (see
typical steam solenoid electrical hook up below).
CAUTION: Never remove ground wire from plug.
2. AromaMist pump models AI-2 and AI-2-4 are 240V AC pumps and have a voltage
regulated internal power supply capable of operating in the range of
approximately 195V to 260V AC. Use a power supply of 210 to 250V AC for best
results. Pump is supplied without a country specific plug unless otherwise
stated (see typical steam solenoid electrical hook up below).
Page 5
C. Plumbing
1. Piping Connections
The AromaMist pump uses carefully matched components to achieve a predictable
metering output. This predictability can only be maintained if all fitting
sizes remain unaltered. Do not attempt to reduce tubing size. All tubing
connections should be double-checked to insure against leakage. If hazardous
chemicals are being pumped, use shielding around discharge tubing.
NOTE:
When cutting lengths of tubing for your installation, ensure a clean, square cut. Use short lengths of tubing and as few connections as possible.
2. Tubing Nuts
Do not over tighten the tubing connectors. Tighten the fittings no more than
1/4 turn after the fitting contacts the seal. Hand tighten only. Do not use a
wrench or pliers as they may damage the fittings. Do not use Teflon tape
except on NPT fittings. Be sure to observe applicable local plumbing codes.
WARNING: Clear flexible tubing is not intended for pressurized use. 3. Tubing Connections
Page 6
4. Suction Lift vs. Flooded Suction Applications (models AI-1 and AI-2 only)
Suction Lift Installation Mount the AromaMist pump on the top of or above a
chemical tank, not to exceed 5 feet from pump to bottom of tank. Flooded
Suction This installation is recommended wherever possible. Priming is easier
and loss of prime is reduced.
5. Foot Valve Installation (models AI-1 and AI-2 only) A weight is provided
to hold the tubing and foot valve in a vertical position at the bottom of the
tank. Do not allow the foot valve to lie horizontally in the chemical
container. This defeats the action of the valve and can cause the pump to lose
prime. Keep suction tubing reasonably short and avoid high spots or bends.
Page 7
6. Wall Mounting
The fluid end portion (head assembly) of the pump is set up to accommodate
mounting of the pump to the chemical container, either as a flooded suction or
a suction lift. The pump head must be kept in a vertical position for proper
operation. The head can be removed and rotated 90° if needed to keep the inlet
and outlet valves in a vertical position.
7. Injection Valve Installation The injection valve is designed to prevent a
back flow and to inject chemical into the line. To work properly, this valve
must NOT be mounted above the steam line or facing downward into the steam
line. One end of the injection valve is 1/2″ MNPT. Install this end into the
piping system. Use Teflon tape on this fitting only. Connect the pump’s
discharge tubing to the opposite end of the injector. Do not use Teflon tape
or joint compound on this fitting. Connect tubing between this fitting and the
pump discharge fitting at the pump.
8. Priming/Bleed Valve Connection (models AI-1 and AI-2 only) Connect the
clear poly tubing to the outlet of the bleed or priming valve. Position the
free end of this tube in the chemical container, above the fluid level.
Page 7
AromaMist AI-1-4 / AI-2-4
Typical Installation
AromaMist Electrical Detail
Page 9
V. Start-Up
A. Front Panel Description
Model AI-1 and AI-2 pumps come with the following standard panel features:
Programmable Features Strokes Per Minute Limit Timer On-Delay Off-Delay Restore Factory Defaults
Range of Feature 1 to 99 0 to 240 Minutes (4 Hours) 0 to 7200 Seconds (120
Minutes) 0 to 480 Minutes (8 Hours) Y’es or
N’o
Default of Feature 10 Strokes Per Minute 60 Minutes 20 Minutes 4 Hours 40 Minutes N
Page 10
B. Priming the Pump
1.Pump Priming Mode Plug in and/or power up the pump at the switch. If pump is
in stroke mode, (pump LCD display reads “strokes/min”) press the enter (ENTER)
key to initiate the pump priming mode. If pump is in delay mode, (pump LCD
display reads “start in: xxx min xx sec”) power down the pump. With pump off
and while pressing on the down arrow () key, power on the pump at the switch
to initiate pump stroke mode. Press the enter (ENTER) key to initiate the pump
priming mode. Note: Prime mode (125 strokes/minute) will always automatically
default to stroke mode after 1 minute. If additional priming time is desired,
press the enter (ENTER) key during the stroke mode to initiate further
priming. Repeat as necessary until pump priming is complete (see step 2). To
exit the pump priming mode, press the enter (ENTER) key to return to the pump
stroke mode.
2.Priming/Bleed Valve With pump in priming mode, if fluid begins moving up
suction line without hesitation, bleed valve adjustment is not required. If
fluid is not moving up suction line, open bleed valve approximately one (1)
turn or until fluid begins to move. When fluid level reaches the pump head
assembly, close bleed valve allowing fluid to flow through pump head and up to
the injector spray head assembly. Once priming is completed, press the enter
(ENTER) key to return the pump stroke mode. NOTE: Do not over-tighten bleed
valve as damage may occur.
Page 11
C. Adjusting Pump Feed Rate/Strokes per Minute
The AromaMist pump can be adjusted to deliver the exact fluid feed rate
desired. The number of pulses/strokes per minute can be easily adjusted and
displayed on the pump LCD display. Feed rate can be adjusted from 1 to 99
strokes per minute. Depending on application, desired feed rate will vary.
Starting with the factory pre-set 10 strokes per minute, adjust the fluid feed
rate up or down depending on your particular application.
To adjust the feed rate: · While in the pump stroke mode, press the menu
(MENU) button. The LCD display will read “Strokes = 10/min”
· With the blinking cursor on the XX, (the number field) press the up arrow ()
to increase the strokes/minute or press the down arrow () to decrease the
strokes/minute.
· Press the menu (MENU) button to exit the feed rate adjustment mode.
D. Adjusting the “Limit To”
If the AromaMist pump strokes continuously for more than 60 minutes, the pump
will go into an Alarm mode and stop stroking. Further investigation should be
made as to why the electrical source kept the pump in a stroke mode for a
continuous 60 minutes.
If the AromaMist pump is in Alarm mode, turn the power switch to the off mode
and then power it on again to reset the Alarm mode. The “Limit To” factory
default setting is 60 minutes and can be adjusted from 0 to 240 minutes (4
hours). A setting of 0 turns the “Limit To” feature off.
CAUTION: It is not recommended to exceed the factory 60 minute default
setting.
To adjust the “Limit To” setting:
· Press the menu (MENU) button.
· Press the enter (ENTER) button to skip over “strokes = xx/min”.
Page 12
· When the LCD displays “Limit To: XX Min” use the up arrow () and down arrow
() buttons to adjust the desired Limit To.
· Press menu (MENU) to exit “Limit To” adjustment mode
E. Adjusting the “On Delay”
On cold equipment start-up, the AromaMist pump is programmed to delay for 20
minutes before it begins to pump fluid. This “On Delay” allows for the time it
takes steam to be generated before fluid is introduced into the steam line.
When the pump is in the “On Delay” mode, the LCD display will read “start in:
xxx min xx sec”, and the keypad is disabled.
You may override the “On Delay” mode by powering the pump on at the switch
while simultaneously pressing the down arrow () key.
Note: The “On Delay” feature is designed to prevent fluid waste.
Adjustable from 0 – 120 minutes, the “On Delay” should be set for one minute
less than the amount of time it takes your equipment to generate steam on a
cold start-up. If you believe an adjustment must be made for your application,
please consult the factory prior to proceeding.
To adjust the “On Delay” setting:
· Press the menu (MENU) button
· Press the enter (ENTER) button to skip through the Strokes = x/ min
· Press the enter (ENTER) button to skip through the Limit To XX Min
· When the LCD displays “On xxx min xx sec” use the up arrow () and down arrow
() buttons to adjust the desired on delay.
· Press menu (MENU) to exit “On Delay” adjustment mode.
Page 13
F. Adjusting the “Off Delay”
The AromaMist pump allows for an “Off Delay” adjustment in order to determine
when the pump startup should be delayed. After initial cold start-up, and
during operation, there will not be an “On Delay” occurrence unless the
AromaMist Pump has been powered off for the amount of time selected in the
“Off Delay” adjustment mode. The factory default is set for 4 hours 40
minutes. The “Off Delay” is adjustable from 0-8 hours (480 minutes). Note:
“Off Delay” settings need only be adjusted if during any normal operating day,
the AromaMist Pump will NOT be off for more than 4 hours (240 minutes). If you
believe an adjustment must be made for your application, please consult the
factory prior to proceeding.
To adjust the “Off Delay” setting: · Press the menu (MENU) button · Press the
enter (ENTER) button to skip through the Strokes=xx min · Press the enter
(ENTER) button to skip through the Limit To XX Min · Press the enter (ENTER)
button to skip through the “On xxx min xx sec” · When the LCD displays “Off x
hr xx min” then use the up arrow () and down arrow () buttons to adjust the
time accordingly. · Press menu (MENU) to exit the “Off Delay” adjustment mode.
Page 14
G. Restoring Factory Defaults
The AromaMist pump has been programmed with a feature allowing it to be reset
to factory default settings. To clear AromaMist pump memory settings and
return to the factory defaults:
· Press the menu (MENU) button. · Press the enter (ENTER) button to skip
through the “Strokes = xx/min.” · Press the enter (ENTER) button to skip
through the “Limit To XX Min.” · Press the enter (ENTER) button to skip
through the “Limit To.” · Press the enter (ENTER) button to skip through the
“On xxx min xx sec.” · Press the enter (ENTER) button to skip through the “Off
xx hr xx min.” · When the LCD displays “Restore Defaults? N”, press the up
arrow ()
or down arrow () to change the response to “Y.” · Press menu (MENU) to exit
this mode.
VI. Maintenance
The AromaMist pump is designed for long service life with minimum maintenance.
If for any reason maintenance is necessary or desirable, the AromaMist pump is
easily maintained. Before any maintenance or service is performed, observe the
following precautions:
1. Disconnect the AromaMist pump from power source. 2. Drain chemical from
discharge tubing. 3. Disconnect discharge tubing from pump. 4. If the
AromaMist pump is used in a flooded suction application, remove
foot valve from chemical container. 5. Observe relevant safety protocols when
handling parts which have been in
contact with hazardous chemicals.
Page 15
NOTE: Tighten pump head screws after pump’s initial week of operation.
1. Remove fluid end cover by lightly prying it loose from the fluid end. 2.
Remove the four screws attaching the fluid end to pump body. 3. Remove the
fluid end from the pump body. 4. Unscrew the diaphragm from the pump shaft in
a counter-clockwise
direction. Be careful that diaphragm support ring does not fall out. 5. Do not
allow sharp or abrasive objects to come in contact with pump parts. 6. Inspect
end of shaft to assure that threads are in good condition.
Replace shaft bellows if necessary. No further disassembly is recommended. 7.
Screw new diaphragm onto pump shaft until it bottoms out on shoulder of shaft.
It is not necessary to tighten further. 8. Replace fluid end. Make sure that
screws are evenly tightened. 9. Reconnect plumbing and power. Prime the pump.
Page 16
B. Check Valve Replacement, Suction
NOTE: When installing check valves, remember that the seats are always
installed at the bottom.
1. Disconnect suction tubing from pump. 2. Remove fluid end per previous
procedure. 3. Unscrew suction fitting from pump head. 4. Remove check valve
from suction fitting and replace. 5. Remove O-ring from cavity in fluid end.
6. Remove check valve from suction side of pump and replace. 7. Install new
O-ring in suction cavity of fluid end. 8. Replace suction fitting with check
valve in fluid end. 9. Replace fluid end. Make sure that screws are evenly
tightened. 10. Reconnect plumbing and power. Prime the pump.
C. Check Valve Replacement, Discharge.
1. Disconnect discharge tubing from pump. 2. Remove fluid end per previous
procedure. 3. Unscrew discharge fitting from pump head. 4. Remove check valve
from discharge fitting and replace. 5. Remove O-ring from cavity in fluid end.
6. Remove check valve from discharge side of pump and replace.
Some resistance may be encountered when removing this valve from the fluid
end. If so, insert an abrasion free object (the inner tube from a ballpoint
pen, will work) in the face of the pump head to push it out. 7. Install new
O-ring in discharge cavity of fluid end.
Page 17
8. Replace discharge fitting with check valve in fluid end. 9. Replace fluid
end. Make sure that screws are evenly tightened. 10. Reconnect plumbing and
power. Prime the pump.
D. Liquid End Diagram
10 13
6 9 1 14
2
13 12
7 3
4 8
Item Description
1
Complete Head Kit (includes)
2
Pump Head *
3
Pump Diaphragm *
4
Support Ring *
5
Shaft Seal *
6
Head Bolts *
- Not sold separately
57
Discharge Valve
8
Suction Valve
9
Priming Valve
10 Injection Valve
11 Foot Valve
12 Ceramic Weight
13 Discharge & Suction Tubing
14 Priming Tubing
**Brass Check Valve
Stock Code AROMAMIST014
AROMAMIST015 AROMAMIST016 AROMAMIST017 AROMAMIST004 AROMAMIST002 AROMAMIST003
AROMAMIST001 AROMAMIST018 AROMAMIST027
**Tank Plug
AROMAMIST029
11 ** Items not shown and exclusive to aroma tank on model AI-1-4 and AI-2-4 pump systems.
Page 18
VII. Troubleshooting
Problem
Pump does not achieve or maintain prime
Insufficient fluid
Cause
Remedy
Air trapped in suction line
Straighten suction line so as to eliminate high spots.
Foot valve contaminated Inspect foot valve screen and assure that foot
or improperly installed
valve is in a vertical position below fluid level.
Excessive lift
Maximum suction lift is 5 feet with water or fluids of similar specific gravity; less with heavier liquids such as acids. Mount pump in a lower position relative to the chemical container.
Suction fittings not properly tightened
Check fittings. Overtightening may cause
restriction. Conversely, if any leakage occurs, pump will suck air and fail to
prime.
Worn or contaminated check valves
Inspect check valves in fluid end for cleanliness. Clean or replace as necessary.
Kink or pinch in suction tube
Inspect suction tube through its full length to assure that there are no kinks or other restrictions.
Move any objects or equipment which impinges upon suction tube or reroute as required to assure a smooth transition from foot valve to pump.
Low chemical level
Check fluid level in chemical supply tank.
Worn or contaminated check valves
Inspect, clean or replace as necessary.
Obstruction in suction line Check suction line for obstructions, clogging, kinks or pinch points.
Clogged foot valve screen
Clean or replace foot valve screen.
Diaphragm worn or torn
Replace diaphragm, making sure that it is screwed on fully to shoulder of shaft.
Electronic failure
Consult dealer or factory.
Page 19
Problem
Excessive fluid
Pump will not pump
Pump will not run or not plugged in Excessive noise
Cause
Remedy
Failure or lack of antisiphon valve
Inspect or add anti-siphon valve. This is caused when system is in a vacuum condition or valve in delivery applications with flooded suction which feeds systems at very low pressures.
Excessive stroke rate
Lower the stroke rate if adjustable on your pump.
Improper stroke length
Consult dealer or factory.
System pressure too high Check system pressure to assure that it is within system rated parameters of the pressure.
Diaphragm improperly installed
Make sure that diaphragm is screwed fully onto shaft.
Check valves worn or clogged
Clean or replace as required.
Pump not turned on or not plugged in
Check outlet with meter to assure that 95-135 VAC is present on 120V systems, 195-260 VAC is present on 240V systems and that power supply cord is in good condition and plugged in.
Electronic failure
Consult dealer or factory.
Pump not primed
Prime pump.
No output pressure
Add an anti-siphon valve to provide 25 PSI restriction on pump discharge.
Distributed by Accurate Industries www.AccurateIndustries.com
847-465-8990
Page 20
AIM4-1011
VIII. Product Warranty
AromaMist
Limited Lifetime Warranty
If you should experience a problem with an AromaMist pump system, simply call
(800) 97-STEAM (78326), and tell us your model and serial number of the pump
and problem.
If we can’t get your pump working over the phone, a fully warranted
replacement will be shipped out the same day on 30-day memo billing. We will
ask for a P.O. number for tracking purposes on the replacement unit which will
only be used if the non-functioning pump is not returned. It is critical for
us to get the old pump back for engineering evaluation as we continually
strive to enhance our products.
A c c u r a t e I n d u s t r i e s warrants the AromaMist Essential Oil
Delivery System of its manufacture to be free of defects in material or
workmanship for the life of its use provided solely AromaMist essential oils
are used; otherwise, liability under this policy extends for one (1) year from
the date of purchase. Liability is limited to repair or replacement of any
failed equipment or part proven defective in material or workmanship upon
manufacturer examination. Removal and installation costs are not included in
this warranty. Manufacturer’s liability should never exceed the selling price
of equipment or part in question.
A c c u r a t e I n d u s t r i e s disclaims all liability for damage caused
by its products by improper installation, maintenance, use or attempts to
operate products beyond their intended functionality, intentionally or
otherwise, or any unauthorized repair. Accurate Industries, Inc. is not
responsible for damages, injuries or expense incurred through the use of its
products.
The above warranty applies in lieu of other warranties either expressed or
implied. No agent of ours is authorized to provide any warranty other than the
above.
Page 21
1/2″ Brass T
3-Function Valve
Steam Line Priming Tube
Discharge Tubing
AROMAMIST TANK OPTION
(Typical Installation)
Steam Outlet (simulation)
Grounded 120V AC Outlet
Power Supply Outlet Module
AromaMist Switch Cable
Tank Lid
Aroma Tank
Aroma Pump
Bleed Valve
Steam Generator
Suction Tubing
Tank Shut-off Valve
Power Cord (110V AC)
AromaMist Switch
If AromaMist metering pumps are designed to work with AromaMist oils only. you
have recieved this page, you have purchased the AromaMist Aroma Oil Pump
System with the optional Aroma Tank.
This page replaces the installation section IV, letter F on page 7 of the
enclosed installation manual. While following the provided step-by-step
AromaMist Pump Installation detail beginning on page 7, ignore points 1-11 and
14-15, as they do not pertain to an aroma tank installation.
AIM5-507
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>