Miele PFD 103 SCi XXL Integrated XXL Dishwasher
Installation notes
For safe installation and commissioning of the dishwasher please read the
installation plan, the service documentation, the installation sheet and the
operating instructions. This installation plan includes the dimensions of the
appliance, the technical data and the requirements to be met on site for the
installation of the dishwasher.
Installation requirements
This dishwasher must only be installed and commissioned by the Miele
Customer Service Department, a Miele authorised dealer or a suitably qualified
specialist.
Installation should only be performed in accordance with valid regulations,
relevant standards and health and safety codes.
Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any
furniture and fittings in the room must therefore be suitable for purpose.
Vapour barrier film for built-in appliances
The vapour barrier film supplied protects the worktop from damage caused by
steam when the door is opened. Attach the vapour barrier film above the door,
underneath the worktop.
Electrical connection
All work on the electrical connection must be carried out by the Miele
Customer Service Department, an authorised Miele dealer or a qualified
electrician.
Plug connection
The dishwasher should be connected to the electricity supply via a suitably
rated plug and socket.
Hard-wired
If the dishwasher is hard-wired to the power supply, a power switch capable
of disconnecting the dishwasher at all poles must be installed on site. This
power switch must have a contact gap of at least 3 mm. The means for
disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules AS/NZS 3000.
The socket and the power switch must be accessible after the appliance has
been installed. An electrical safety test can then easily be carried out,
e.g., after any service or maintenance work.
The connection cable must be protected from the risk of thermal damage.
Residual current device (RCD)
For increased safety, it is recommended to protect the dishwasher with a
residual current device (RCD) with a trip current of 30 mA.
Equipotential bonding
There is a screw connection point for equipotential bonding at the back of
the dishwasher.
Equipotential bonding should be carried out if possible on site.
Water connection
The dishwasher must only be connected to fully vented pipework. A brief
increase in the water pressure can damage components of the dishwasher.
Water inlet
The quality of the incoming water must correspond to the drinking water
specification of the country in which the dishwasher is being operated. The
dishwasher must be connected to the water supply in strict accordance with
current local and national requirements (e.g. Plumbing Code of Australia
(PCA)). It can be connected to cold or hot water supplies. Connecting the
dishwasher to a hot water supply will reduce programme running times.
For short programme running times, dynamic water pressure of at least 200 kPa
is also required. This appliance must be installed according to AS/NZS 3500.1
and AS/NZS 3500.2. This dishwasher has been supplied with a separate backflow
prevention device (dual check valve).
Installation requirements
The dual check valve supplied separately with this product must be installed
between the tap and the water inlet hose. Screw the dual check valve onto the
tap. Then screw the water inlet hose with the water protection system onto the
thread of the dual check valve. Turn on the the tap gradually to test for
leaks. If there is a leak, the connection might not be on securely, or it may
have been screwed
on at an angle. Unscrew and reconnect the water correctly before tightening
it. If a tap is not available, only a qualified installer may connect the
dishwasher to the mains water supply. The tap should remain accessible once
the dishwasher has been installed so that the water supply can be shut off
whenever the appliance is not in use.
Drain
The dishwasher drain hose should be connected to a separate on-site drainage
system for the dishwasher only. If a separate connection is not available, we
recommend connecting the hose to a dual-chamber siphon. If the hose is to be
fitted directly to the drainage system on site, use the hose clip supplied
with the dishwasher. The on-site connector for the drain hose can be adapted
to different hose diameters. If the connector extends more than 30 mm into the
drain hose, it must be shortened. Otherwise, the drain hose can become
blocked. Lay the drain hose so that it does not kink and is not being
subjected to pressure or tension. If the on-site drain connection is situated
lower than the guide path for the lower basket rollers in the open door, a
siphoning effect during a programme can cause the wash cabinet to empty itself
of water. In this case, lay the drain hose with a bend in it so that its
highest point is at least level with the guide path for the lower basket
rollers
External dispensing
An external dispensing module for liquid cleaning agents can be connected to the back of the dishwasher. The dispensing module is available as an optional accessory and is supplied with installation instructions.
Appliance dimensions and installation dimensions
PFD 103 SCi XXL
Front panel dimensions
Length | [mm] | 540–694 |
---|---|---|
Thickness | [mm] | 16–20 |
Weight | [kg] | 4–11 |
Connections on the back of the appliance
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of appliance to DOS module | [m] | 2.8 |
Length of power cable, back of appliance to DOS module | [m] | 2.8 |
Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.
Technical data
Technical data | |
---|---|
Dimensions and weights | |
Height | [mm] |
Height adjustment | [mm] |
Width | [mm] |
Depth | [mm] |
Depth with door open | [mm] |
Max. plinth return | [mm] |
Weight | [kg] |
Max. floor load | [N] |
Emission levels | |
Sound power level | [dB(A) re 1 pW] |
Sound pressure level in the workplace | [dB(A)] |
Electrical connection
Standard electrical connection
Voltage | AC 230 V | |
---|---|---|
Frequency | [Hz] | 50 |
Fuse rating | [A] | 10 |
Plug | Yes | |
Power cable length | [m] | 1.7 |
Power cable cross-section | [mm2] | 3×1 |
Heat output | [kW] | 1.9 |
Total rated load
Possible voltage variant
| [kW]| 2.1
Voltage| | 3N AC 400 V
Frequency| [Hz]| 50
Fuse rating| [A]| 16
Plug| | –
Power cable * length| [m]| 1.7
Power cable cross-section| [mm2]| 5×2.5
Heat output| [kW]| 7.1
Total rated load| [kW]| 7.3
- Optional accessory
Water inlet
Max. water temperature | [°C] | 60 |
---|---|---|
Max. water hardness | [mmol/l] | 6.5 |
Max. water hardness | [°dH] | 36 |
Water connection pressure | [kPa] | 50–1000 |
On-site threaded union (flat seal) | [inches] | 3/4 |
Connection hose length | [m] | 1.5 |
Drain
Technical data | |
---|---|
Drain | |
Max. water temperature | [°C] |
Drain hose length | [m] |
Max. drain hose length | [m] |
Max. delivery head | [m] |
Max. transient flow rate | [l/min] |
Hose inner diameter | [mm] |
On-site hose sleeve ( x length) | [mm] |
Operating conditions | |
Ambient temperature | [°C] |
Relative humidity:
Up to 31 °C, maximum
| [%]|
80
Linear decreasing to 40 °C| [%]| 50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions
Ambient temperature| [°C]| -20 – +60
Relative humidity| [%]| 10–85
Air pressure| [hPa]| 500–1060
Min. site access dimensions including transport pallet
Height| [mm]| 970
Width| [mm]| 670
Depth| [mm]| 670
Miele Australia Pty. Ltd.
ACN 005 635 398
ABN 96 005 635 398
Melbourne:
Level 4, 141 Camberwell Road Hawthorn East, VIC 3123 Telephone: 1300 731 411
service.prof@miele.com.au
www.miele.com.au/professional sales
@miele-professional.com.au
Miele New Zealand Limited
IRD 98 463 631 8 College Hill Freemans Bay Auckland 1011 New Zealand
References
- Miele Professional AU | Discover our Commercial Solutions
- Miele Professional AU | Discover our Commercial Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>