GIMA 24-07 Restraint Bed Belt Instruction Manual

July 26, 2024
GIMA

GIMA 24-07 Restraint Bed Belt

Product Information

Specifications

  • Product Name: Restraint Bed Belt
  • Material: 100% Cotton
  • Manufacturer: Erregi S.a.s.
  • Compliance: Medical Device compliant with Regulation (EU) 2017/745

Product Description
This Restraint Bed Belt is designed for restraining bedridden patients. It is made of 100% cotton material, ensuring comfort and durability.

Warnings
Before use, visually inspect the device for any abnormalities. Do not use the product if any irregularities are found. Contact the point of sale for assistance. The manufacturer shall not be held responsible for improper use of the device.

Product Usage Instructions

  • Precautions for Use
    Avoid using the product if the patient is sensitive to the component materials.

  • Washing Instructions
    Remove keys and blocks before washing to prevent damage. Wash according to the provided instructions to maintain the technical features of the aid.

  • Disinfection
    Use medical surgical products for disinfection purposes.

  • Storage
    Store the belt away from light, heat, and humidity to prolong its lifespan.

  • Disposal
    Dispose of the device under environmental protection and recycling regulations.

FAQ

  • Q: Can the Restraint Bed Belt be machine-washed?
    A: Yes, the belt can be washed, but be sure to remove any keys or blocks before washing to avoid damage.

  • Q: Is the Restraint Bed Belt latex-free?
    A: Yes, the product is not made with natural rubber latex.

SAFETY WARNINGS

  • Before carrying out any operation, visually check the integrity of the device. If the product shows any abnormalities, immediately contact the point of sale.
  • Erregi S.a.s. shall not be held responsible in case of improper use of the device. In the event of a serious accident involving the use of the device, please report the incident to the manufacturer and to the competent authority of the member state where the user and/or patient lives.

DESCRIPTION

  • Art 24/07: Double restraint bed belt made of 100% cotton. The locking system employs a magnetic key. The magnetic key is used to open the safety blocks: one block is used to lock the upper belt to the patient’s waist, while the other two blocks are used to anchor the straps to the bed rail. The device is used to restrain an uncooperative patient in need of therapy. It consists of two belts: the inner one is placed around the patient’s waist, while the outer one is fastened to the bed rail utilizing the straps and safety blocks.
    The patient can be placed both in the supine and lateral position with this belt.

  • Art 24/07/01: Single restraint bed belt made of 100% cotton. The locking system uses a magnetic key. The magnetic key is used to open the safety block, the block is used to lock the upper belt to the patient’s waist. The device is used to restrain an uncooperative patient in need of therapy. It consists of one belt, to be placed around the patient’s waist, and two straps with hook closures to be fastened to the bed rail. The belt only allows the patient to be in a supine position.

INDICATION
Devices used for restraining bedridden patients.

CONTRAINDICATIONS

No contraindications were found except in cases of ascertained sensitivity to the component materials.

PRECAUTIONS FOR USE

The device can only be applied by doctors and paramedics. The belt must not be used on the pelvis or ribcage. Devices with magnetic closures; do not use on patients who have a pacemaker, as it may cause tachycardia. Fit the belt on the patient properly; it must be possible to place a hand between the patient and the belt. Always check that the fasteners are securely fastened, otherwise the patient’s safety may be compromised. If the fasteners do not open, the belts can be cut using a cutter or shears. Always wear personal protective clothing when using the device. Device is not fireproof.

MATERIAL
100% COTTON.

WASHING INSTRUCTIONS

Warning:
Remove keys and blocks before washing; their functionality may be compromised if they come into contact with water. The manufacturer is not liable for any changes in the technical features of the aid in the event of failure to observe the washing methods.

DISINFECTION
Use medical-surgical products.

STORAGE
Store away from sources of light, heat, and humidity.

DISPOSAL

Dispose of the device in compliance with the current regulations on environmental protection and recycling.

DO NOT remove the label from the Medical Device, as it allows tracing the supplied product (Manufacturer, UDI, batch number, product code).

GIMA WARRANTY TERMS

The Gima 12-month standard B2B warranty applies.

Erregi S.a.s.

MADE IN ITALY.