newtech 3175 GW VIA NO-COS ROMA-C Citi Wall Hung Vanity Installation Guide

July 26, 2024
Newtech

new tech 3175 GW VIA NO-COS ROMA-C Citi Wall Hung Vanity

IMPORTANT
Thank you for purchasing one of our products. NEWTECH RECOMMENDS THAT A QUALIFIED TRADESPERSON INSTALL THIS PRODUCT AND THAT IT IS INSTALLED TO A PROFESSIONAL STANDARD. This product carries a full warranty against faulty workmanship and materials. Please inspect for damage before installation. It is the responsibility of the installer to make any necessary adjustments to doors and drawers after installation if required.

Preparation

IMPORTANT – ARE YOU INSTALLING THIS PRODUCT?
Please READ the installation instructions in this booklet BEFORE INSTALLATION. Newtech recommends that a qualified tradesperson install this product and that it is installed to a professional standard, by this instruction booklet. Failing to do so may void the warranty. This product carries a full warranty against faulty workmanship and materials. Please inspect for damage before installation. It is the responsibility of the installer to make any adjustments to doors/drawers after installation if required.

POSITIONING & VENTILATION

  • The floor needs to be level and the wall straight.
  • A gap of at least 150mm needs to be left between a bath and a vanity unit.
  • Do not expose the vanity unit to shower spray.
  • A water barrier, e.g. a glass shower panel needs to be between any vanity unit and shower
  • The bathroom must be adequately ventilated as high humidity can lead to deterioration of materials.

CHECK SUPPORT NOGS

Wall-hung furniture and wall-hung ceramic basins require fixing to support nogs fitted between the studs, as detailed, to give a solid wall backing to attach the vanity. If necessary fix additional support nogs at a desired height for cabinet and basin fixing. Ensure the total width of the support nog exceeds the vanity width. Refer to step 6b ‘fixing basins’

ENSURE WALLS ARE PLUMB AND FLOORS ARE LEVEL
Ensure the Wall is plumb and straight, and ensure the floor is level. If you fix the product to a non-plumb wall or floor the following will happen:

  • Your door or drawers will not operate correctly
  • Door or drawer adjustments will not align.
  • Basins will not sit level, which may cause water to pool or not drain correctly

If it is not possible to make the wall or floor plumb and straight you must pack the vanity out so that it does not follow the out-of-aligned wall. Floor- standing vanities must sit on a level floor or be packed to sit level and true.

CHECK PLUMBING POSITIONS PROPERLY ALIGN
Measure and mark the cabinet for the location of waste and hot/cold water supply. Drill from the inside of the cabinet using an appropriately sized hole saw.

Note: If your product has any electrical fittings please allow for this and talk to your electrician.

Vanity Unit Installation

PREPARE THE CABINET
Remove doors & drawers and drill holes for plumbing in the back panel and/or base of the cabinet with an appropriate-sized hole saw. Pre-drill screw locations for fastening to the wall – see p6.

TAP HOLE
StoneCast Stab Tops require a tap hole to be drilled. We recommend using a Blue-Mole 35mm hole saw. Ensure to drill the hole from the top of the basin.

MEASURE UP
Mark the position of the top of the vanity – factor in the top/ basin thickness to get the correct height. Use a single screw in the center of the vanity, or use some support stands to hold the cabinet in place, ready for installation.

LEVEL THE VANITY

Note: Floor standing vanities should likewise, be checked for sitting level, plumb and square, and suitably packed to achieve this. Fix the wall through the L bracket installed on the cabinet and then ensure solid fixing along the upper back.

SECURE THE CABINET
Cabinet Mounting Brackets require solid fixing (145 x 45mm) behind the wall surface. It must be capable of anchoring 35mm length with a 12g Screw Thread centered 75mm down from the proposed top of cabinet height (see detail B). Note: The Frank vanity has a full-height back, installation requires a screw through the L bracket provided on the vanity. The vanity basin top will sit above this height). Each bracket supports up to 100kg. NOTE: Cabinets require additional fixing points evenly spaced at 300mm along the top edge of the back (see detail C).

Vanity Unit Installation Continued…

FITTING THE WASTE
When installing a waste, be wary not to overighten, as doing so can cause the ceramic to crack. Make sure to use appropriate waste for the basin. Basins fitted with an overflow require an overflowing waste. Basins without overflow should not have overflow waste fitted, as this can cause leaking. Ensure that no excess silicone or putty is obstructing the water flow.

FIXING THE BASIN
Position the top so that it has an equal amount of overhang on each side and use a level to ensure the vanity top surface is level.

Note: If the vanity is being installed in a corner, a packing strip is required and basin location will vary.

FIXING THE BASIN
Apply Silicone Sealant (not included) to all four corners of the cabinet. Place the vanity top/basin onto the cabinet. If installing a basin with wall bolt fixings – ensure basin bolts are fixed into nogs with supplied fixings as well as use a silicone sealant to the top edge of the cabinet.

SEAL
Apply silicone on the seam between the edge of the vanity top and the wall, smooth the bead, and allow it to cure before use. Materials used for the construction of this unit are water resistant and not waterproof. A fine bead of sealant (specifically formulated for bathrooms) must be used to seal edges where water penetration can occur i.e. Between the basin and the cabinet and between the wall and floor of the cabinet.

CLEAN
Clean away all building residue from the cabinet. Take care to dry any spillage or leakage of water on or inside the cabinet during installation. Note: Ensure drawer runners are free of building residue as this may affect the operation.

INSTALLATION NOTE
During the installation of larger vanities ie. 1200 & 1500mm wide, please ensure the top rail is straight. To ensure this stays straight and secure please use a small amount of glue/silicone to secure the basin during installation.

Hinge Adjustments

HINGE REMOVAL
To remove the door hinge lift the catch at the back of the hinge (1), lift the body off the hinge plate (2), and slide the body of the hinge forward (3).

HINGE OVERLAY ADJUSTMENT
To adjust the door horizontally, use a screwdriver (as pictured) turning clockwise or anti-clockwise until the alignment is straight.

DOOR HINGE HEIGHT ADJUSTMENT

To adjust the height of the door release both hinge plate retaining screws (anti-clockwise), slide the hinge plate up or down to the correct position, and tighten the hinge plate retaining screws.

HINGE DEPTH ADJUSTMENT
To adjust the gap between the cabinet and door, use a screwdriver (as pictured) turning clockwise or anti-clockwise until it is straight.

Drawer Runner Adjustments

PLEASE NOTE: FRANK VANITIES HAVE PARTIAL EXTENSION RUNNERS NOT FULL EXTENSION

REMOVING DRAWER
Open the drawer fully. Press the grey levers inwards located under the drawer and pull the drawer forward with both hands placed on either side of the drawer.

INSERTING DRAWERS
With the drawer runners fully retracted, place the drawer back onto the runners, push closed, and listen for a double click and push closed.

INSTALLING & REMOVING COVER CAP
Extend the drawer out and either pull the cap off or push it back on.

REMOVING GALLERY RAILS
To remove the gallery rails, slide the white tabs (1) toward the back of the drawer, and the gallery rail will lift out of the front connector.

REMOVING DRAWER FRONT
To remove the front panel extend the drawer and remove the cover cap. Disconnect the gallery rails and remove the pin located underneath the drawer front. The pin is removed by pressing lightly on the base of the drawer. Once removed, push the blue button, and then the drawer front can be released and lifted out.

NOTE: The drawer runner adjustments apply to all cabinetry drawers, including the internal cosmetic drawer.

Drawer Runner Adjustments continued

ADJUSTING FRONT PANELS (DRAWER FRONTS)

  1. Remove the plastic covers on the side.
  2. To make adjustments up or down use the little cogged wheels to turn each side as above.
  3. To make adjustments left and right use a screwdriver to adjust the screw on the right-hand drawer side as above.
  4. To make adjustments in and out slide the square gallery rail cover back and use a screwdriver to turn the gallery rail adjuster as above.

Troubleshooting

Product Care

Newtech products are produced from materials that are well suited to the bathroom. Our vanities are designed to be water resistant, not waterproof. Your bathroom must be adequately ventilated to eliminate moisture build-up. High humidity will lead to permanent dampness and mould resulting in a deterioration of the materials in your bathroom. Please ensure care is taken that vanities are not exposed to large amounts of continuous water as this can lead to damage and is not covered under our Warranty on page 10.

VANITY INSET BASINS – STONECAST & VITREOUS CHINA
Newtech vanity tops and basins are manufactured from the finest materials and when treated with care will last for many years. Do not subject the basin or vanity top to water at a temperature above 55°C. Keep high heat away from the vanity top or wash basin and avoid metal or other sharp objects which could scratch and damage the surface. A simple wipe-over with a damp cloth after use is all that’s required. If you need to use household cleaners do not use strong citrus-based cleaners, abrasive cleaners, chemicals, disinfectants, acetone, alcohol, or cleaners that incorporate isopropyl alcohol. Carefully read the cleaner product label to ensure the cleaner is safe for use on the material. The use of cleaners containing harmful ingredients (as identified above) will void Newtech’s warranty. Limescale marks may be reduced by regular cleaning of the washbasin. *Handy Tip – Stubborn limescale marks can normally be removed using a solution of vinegar and water.
Ceramic Tops – Newtech Vitreous China Basins are handcrafted and fired at high temperatures, which can lead to visual imperfections and distortions. This all being part of the vitreous China experience, a 5mm tolerance is considered an acceptable quality definition of conformity. StoneCast Tops – Our composite StoneCast basins and slab tops are constructed by combining natural minerals with high-performance resins creating an increased resistance. StoneCast products are moulded into precise designs creating clean, straight lines and edges with no natural imperfections.

CABINETRY, HETTICH HARDWARE, HANDLES & ACCESSORIES
Our products are manufactured from high-quality materials in an easy-to-clean laminate finish (Vista Range). All materials used are water resistant but not waterproof unless stated. All water spillages, leaks, or flooding in or around the cabinet must be sponged off and dried immediately – this includes condensation. Keep heat away from the vanity and avoid metal or other sharp objects that could damage or scratch the surfaces. Do not use abrasive cleaning agents that contain ammonia, bleach, or other strong solvents. We also advise against the use of furniture polish, acetone, ethanol, benzene, and coarse cleaning sponges. Carefully read the cleaner product label to ensure the cleaner is safe for use on the material. For regular cleaning, we recommend cleaning with a soft cloth and wrung in hot water with a mild all- purpose cleaning agent.

Warranty Information

VANITIES

  • Cabinetry & Panels Laminate Finish MRB 5 Years
  • Hettich Soft Close Drawer Runners, Cupboard Drawer & Door Hinges Lifetime

ACCESSORIES

  • Chrome, Matte Black, Brushed Nickel, Gunmetal, Brushed Brass, Brushed Copper & Matte White Accessories & Handles 5 Years
  • Evoke Pop-up Basin & Bath Wastes 1 Year

BASINS

  • Vitreous China Basins 10 Years
  • StoneCast or Composite basins 5 Years

This extended warranty only covers Newtech bathroom ware products, and will not extend to products that you have selected outside our product range. This extended warranty only applies to defects that have arisen solely from faulty materials or workmanship in the Products and do not apply to other defects that may have arisen as a result of, without limitation, the following: accidental damage, abuse, misuse, maltreatment, abnormal stress or strain, harsh or adverse weather conditions, including excessive water pressure or temperature, or neglect of any kind of the Products. As per the Building Code Compliance documentation, the maximum temperature sanitary wear can be subjected to is 55 degrees C. Any warranty assessment where the temperature of water for sanitary wear is above 55 degrees C will be declined. The tempering valve must be subject to and comply with NZS4617 or AS1357.2

Alterations and repairs of the Products other than by a Newtech pre-approved service person are not covered. For the avoidance of doubt, attachment of accessories or use of non-genuine replacement parts other than those manufactured or approved by Newtech are not covered by this extended warranty. This extended warranty for the products commences from the date of purchase or for new buildings on the date of handover for the relevant period set out in the warranty period. In addition to this extended warranty, certain legislation may give you certain rights that cannot be excluded, restricted, or modified. This extended warranty must be read subject to such legislation and nothing in this warranty has the effect of excluding, restricting, or modifying those rights. Newtech warranty periods have changed over time so depending on when you purchased your product the warranty period may be different from what is stated in this publication. To make a warranty claim, the following documentation must be emailed or faxed to Newtech:

  • Name/model of product and photographs of the issue, if available;
  • Proof of installation by a licensed plumber and/or proof of purchase;
  • Your contact details; name, address, and best contact phone number;
  • Handover documentation for new homes.

Consequential loss to the extent permitted by law Newtech will not be liable for any loss or damage to furniture, floor coverings, walls, fixtures, or any other consequential loss of any kind caused by any defect in the products or components. A warranty certificate or equivalent documentation must be supplied for warranty claims to be considered. If the cost of returning any defective parts is unreasonable, please contact Newtech so that if appropriate, we can arrange a collection.

Newtech Bathroomware

  • Head Office: 30 Mill Road, Whanganui
  • Showroom: 525 Great South Road, Penrose, Auckland
  • Phone: 0800 728 662
  • Email: sales@newtech.co.nz

HOW TO MAKE A CLAIM

Please contact the merchant the product/s were purchased through and they will be able to lodge a claim with Newtech on your behalf. Once we receive the claim we will review it and may contact you for further information. Once we have assessed the claim and determined that it is the result of a defect covered by the warranty, we will arrange for the repair, replacement,t or refund that we determine to be the best solution. Please also be aware that once we visit the site to investigate or repair the product and find that it is not a defect or product fault and therefore not covered by this warranty, we may charge for the time and travel incurred.

TO THE INSTALLER

Newtech recommends that a qualified tradesperson install this product and that it is installed to a professional standard. Please inspect for damage before installation. It is the responsibility of the installer to make any adjustments to cabinetry doors and drawers after installation if required. If there is damage to the product on freight arrival please immediately contact the merchant the product/s were purchased through and they will lodge a claim with Newtech. Installers need to know that under the Consumer Guarantees Act (CGA) they are responsible for any product they supply AND/OR install.

  • Product Code:
  • Product Name:
  • Date Purchased:
  • Purchased from:
  • Installed by:

VISIT OUR WEBSITE WWW.NEWTECH.CO.NZ
Visit our website to view and download specification sheets, brochures, flyers, installation guides, product care manuals, watch ‘how to videos’ and much more.

VISIT OUR YOUTUBE CHANNEL NEWTECH.CO.NZ/YOUTUBE Videos about Newtech and our products are available on our YouTube channel as well as our website.

HEAD OFFICE & DISTRIBUTION
30 Mill Road, Whanganui, 0800 728 662, sales@newtech.co.nz

CONCEPT SHOWROOM
525 Great South Road, Penrose, Auckland, 09 930 6200 aucklandshowroom@newtech.co.nz

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals