Carrier GH5S CP Split System Heat Pump Using Refrigerant Owner’s Manual
- July 25, 2024
- Carrier
Table of Contents
Carrier GH5S CP Split System Heat Pump Using Refrigerant
Product Specifications
- Product: Split-System Heat Pump
- Refrigerant: R-410A
- Design: Two-stage operation
Product Usage Instructions
Identifying Your System
Your heat pump system consists of an outdoor unit and an indoor unit
connected by refrigerant lines. Locate the model and serial numbers on each
unit for future reference.
Using Your New System
Your system is controlled by a wall-mounted thermostat. Refer to the
thermostat’s manual for detailed operation instructions.
2-Stage Operation
If you have a two-stage system, expect longer run times in low-stage
operation for enhanced comfort and energy efficiency.
Heating and Cooling Your Home
- Set the Mode control to the desired heating or cooling mode.
- Adjust the Temperature control to your preferred setting.
- Choose Automatic or On for the Fan control.
Operation Under Extreme Conditions
Your heat pump will adjust its operation based on the indoor temperature
settings. Expect longer run times on extremely hot days or under specific
conditions.
Routine Maintenance
Perform routine maintenance to ensure optimal performance. Regular
inspections by a trained technician are also recommended for safety and
efficiency.
FAQ (Frequently Asked Questions)
-
Q: How often should routine maintenance be performed?
- A: It is recommended to perform routine maintenance on your heat pump system at least once a year to ensure efficient operation.
-
Q: What should I do if my system is not heating or cooling properly?
- A: Check the thermostat settings, air filters, and ensure there are no obstructions around the outdoor unit. If issues persist, contact a qualified service technician for assistance.
OWNER’S MANUAL
SPLIT-SYSTEM HEAT PUMP USING R-410A REFRIGERANT
A NOTE ABOUT SAFETY
Any time you see this symbol in manuals, instructions and on the unit, be
aware of the potential for personal injury. There are three levels of
precaution:
- DANGER identifies the most serious hazards which will result in severe personal injury or death.
- WARNING signifies hazards that could result in personal injury or death.
- CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.
- NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
WARNING
PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD
- Failure to follow this warning could result in personal injury, death and/or property damage.
- Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage.
- Consult a qualified installer, service agency, or your distributor or branch for information or assistance.
- A qualified installer or service agency must use factory-authorized parts or accessories when modifying this product.
- Read and follow all instructions and warnings, including labels shipped with or attached to the unit before operating your new heat pump.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Disconnect all electrical power to the indoor air handler or furnace before
removing access panels to perform any maintenance. Disconnect power to both
the indoor and outdoor units. There may be more than one electrical disconnect
switch.
ABOUT YOUR HEAT PUMP SYSTEM
Our products are designed, tested and built in accordance with US Department
of Energy standardized procedures and other standards; however, actual
operating results and efficiencies may vary based on manufacturing and
supplier tolerances, equipment configuration, operating conditions and
installation practices.
Identifying Your System
Your new heat pump system is what we call a ”split system.” It has an outdoor
unit and an indoor unit connected to each other with copper tubing called
refrigerant lines. Each of these units has a rating plate with the model and
serial numbers you will need to reference when calling an authorized dealer
about your system.
Take a few moments now to locate those numbers and record them in the spaces
provided on the cover of this booklet.
Using Your New System
Your heat pump system is controlled by a wall-mounted thermostat installed
inside your home. Because there are so many thermostats available, please
refer to the owner’s manual supplied with your thermostat for complete details
on system operation.
Stage Operation
If you own a two-stage heat pump system, you may notice your system runs for longer periods of time. When appropriately sized, nearly 80%of the time it’s running, it is operating in low-stage, and your indoor temperature will remain more consistent with fewer drafts, better humidity control, enhanced comfort and enhanced energy efficiency.
Heating and cooling Your Home
For heating or cooling operation, make sure the System or Mode control is set
to the appropriate mode. Then, adjust the Temperature control to your desired
setting. Finally, use the Fan control to select Automatic (turns on and off as
heating is needed) or On (runs continuously).
Depending on your typical heating needs, your home comfort system may also include a supplementary heating source that will automatically turn on as needed. You may also select this heat source manually if desired.
Operation Under Extreme Conditions
Your heat pump will run as long as necessary to maintain the indoor
temperature selected on your thermostat. On extremely hot days, your heat pump
will run for longer periods at a time than on moderate days. Your system will
also run for longer periods of time under the following conditions
- Frequent opening of exterior doors
- Operating laundry appliances
- Taking hot showers
- More than the usual number of people present in the home
- More than the normal number of electric lights in use
- Drapes or blinds are open on the sunny side of the home
IMPORTANT HEAT PUMP FACTS
Heat pump systems have a few unique features and operations that you should be
aware of
- During the heating cycle, air from your registers may seem cooler than you may expect. This is because your heat pump delivers a constant flow of air at around 90° F (32º C) to about 105° F (41º C), compared to sudden blasts of hot air provided by a typical furnace. This air may feel cool if it is slightly below your body temperature, however it is warm enough to keep your home comfortable.
- Ice or frost may form on the outdoor coil during winter heating operation. Your heat pump will automatically melt the ice using its defrost cycle. During defrost, you may see steam or fog rising from the outdoor unit, which is normal.
- Heat pumps installed in areas expecting snow are elevated with support feet.
- In Extreme weather conditions with heavy snow and ice storms, build-up may accumulate on the top of the heat pump and fan blade, causing excessive vibration that may result in damage and or reduced performance. In these conditions, it may be appropriate to turn the heat pump off and run on auxiliary heat until snow and ice has cleared
OWNERS MANUAL SPLIT-SYSTEM HEAT PUMP USING R-410A REFRIGERANT:
ROUTINE MAINTENANCE
Simple, routine maintenance as described below will enhance your heat pump system’s ability to operate economically and dependably. In addition to the routine maintenance that you perform, your home comfort system should be inspected regularly by a properly trained service technician. Always remember the following safety precautions
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges in the
construction of your unit, be extremely careful when handling parts or
reaching into the unit.
-
Keep Filter Clean
A clogged or improperly installed air filter on your indoor unit will increase operating costs and shorten the life of the unit. For detailed filter cleaning information refer to indoor unit literature. -
Do Not Block Floor, Wall or Ceiling Vents
When drapes, furniture, toys or other common household items block vents, the restricted airflow lessens the system’s efficiency and life span. -
Do Not Cover or Block Outdoor Unit
The outdoor unit needs unrestricted airflow. Do not cover it or place items on or next to it. Do not allow grass clippings, leaves, or other debris to accumulate on the sides or top of the unit. And, maintain a 12” (305 mm) minimum clearance between the outdoor unit and tall grass, vines, shrubs, etc. -
Check Condensate Drain
Your heat pump removes humidity from your home during the cooling season. After a few minutes of operation, water should trickle from the condensate drain of the indoor coil. Check this occasionally to be sure the drain system is not clogged. Drainage will be limited if you live in a very dry environment. -
Do Not Operate Below 55°F/13°C in Cooling Mode
Your outdoor unit is not designed to operate when outdoor temperatures are lower than 55°F/13°C without modification. If operation below this temperature is required, consult your authorized dealer. -
Do Not Operate Above 66°F/19°C in Heating Mode
Your outdoor unit is not designed to operate on heating mode when outdoor temperatures are higher than 66°F/19°C. You can safely operate the system above 66°F/19°C on emergency or auxiliary heat. -
Base Pan Drainage
Periodically check for and remove debris that has settled around the base of your outdoor unit. This will ensure proper drainage of the base pan and eliminate standing water inside the outdoor unit. -
Level Installation
Your authorized dealer will install the outdoor unit in a level position. If the support base settles or shifts and the unit is no longer level, be sure to re-level it promptly to assure proper drainage. If you notice water or ice collecting beneath the unit, arrange for it to be drained away from the unit.
Sea Coast Coil Maintenance
Coastal locations often require additional maintenance of the outdoor unit due
to highly corrosive airborne ocean salt. Although your new heat pump system is
made of galvanized metal and is protected by top-grade paint, take the
additional precaution of periodically washing all exposed surfaces and the
outdoor coil approximately every 3 months. Consult your installing authorized
dealer for proper cleaning intervals and procedures for your geographic area
or ask about a service contract for regularly scheduled professional cleaning
and inspections.
TROUBLESHOOTING
Before you request dealer service, check for these easily solved problems
- Check the indoor and outdoor disconnect switches Also check your main electrical panel circuit breakers or fuses.
- Check for sufficient airflow. Air filter(s) should be reasonably clean and interior vents should be open and unobstructed.
- Check thermostat settings. For cooling, your desired temperature setting should be LOWER than the displayed room temperature, and the System/Mode control should be on Cool or Auto. For heating, your temperature setting should be HIGHER than the displayed room temperature, and the System/Mode control is set to Heat or Auto.
- Time delays – depending on the heat pump you have, there may be delays in unit operation that are built-in to protect the equipment and your comfort. Don’t be alarmed if you notice a time delay in operation. It may be a standard protection feature of your equipment. Check with your authorized Dealer for more information on time delays.
Maintenance Checklist | **Recommended Interval*** |
---|---|
Outdoor unit specific: | Monthly |
Clear away debris and vegetation near unit. | X |
Inspect cabinet for damage. Replace components that are damaged or severely
rusted.| | X
Inspect electrical disconnect for proper function. Repair or replace as
necessary.| | X
Inspect electrical wiring and connections. Tighten loose connections. Inspect
and perform functional test of equipment as needed to ensure proper function.
Repair or replace damaged or overheated components and wiring.| | X
Check refrigerant system sub cooling and/or superheat (system dependent).| | X
Inspect inside of unit. Clean if debris is present.| | X
Inspect condenser coil. Clean if dust, dirt, or debris is present. Rinse unit
with fresh water (see Note 2).| | X
Inspect motor and fan for damage. Make sure fan spins freely.| | X
Indoor specific: (for fossil fuel furnaces and accessories, refer to unit-
specific literature)|
Inspect, clean, or replace air filter if dirty.| X|
Inspect and clean blower assembly (includes blower housing, wheel, and
motor).| | X
Inspect internal and external of cabinet. Clean as needed.| | X
Inspect electrical disconnect for proper function. Repair or replace as
necessary.| | X
Inspect electrical components, wiring, and connections. Tighten loose
connections. Repair or replace damaged components and wiring.| | X
Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note
2).| | X
Clean condensate pan, trap, and drain lines (more frequent maintenance may be
required in humid climates – consult your local HVAC dealer).| | X
Inspect airflow system (ductwork). Check for leaks and repair as needed.| | X
Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service technician. Read all waring labels.
Notes
- The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.
- Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast
© 2021 Carrier. All rights reserved.
- Edition Date: 09/21
- Catalog No: OG-HPR410GEN-04
- A Carrier Company
- Replaces : OG-HPR410GEN-03
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.