BAUHAUS AL 1810 CV Power for All Alliance Instruction Manual

June 15, 2024
BAUHAUS

POWER FOR ALL System
AL 1810 CV | AL 18V-20

AL 1810 CV Power for All Alliance

BAUHAUS AL 1810 CV Power for All Alliance-

BAUHAUS AL 1810 CV Power for All Alliance- icon

BAUHAUS AL 1810 CV Power for All Alliance- parts

Safety instructions

Read all the safety and general instructions. Failure to observe the safety and general instructions may result in electric shock, fire and/or serious injury.

Store these instructions in a safe place.
Only use the charger if you can fully evaluate all functions and carry them out without restrictions, or if you have received corresponding instructions.

  • This charger is not intended for use by children or persons with physical, sensory or mental limitations or a lack of experience or knowledge. This charger can be used by children aged 8 or older and by persons who have physical, sensory or mental limitations or a lack of experience or knowledge if a person responsible for their safety supervises them or has instructed them in the safe operation of the charger and they understand the associated dangers.
    Otherwise, there is a risk of operating errors and injuries.

  • Supervise children during use, cleaning and maintenance. This will ensure that children do not play with the charger.

  • Only charge Bosch Li-ion batteries or PBA 18V POWER FOR ALL system batteries with a capacity of 1.5 Ah. The battery voltage must match the battery charging voltage of the charger. Do not charge any non-rechargeable batteries. Otherwise there is a risk
    of fire and explosion.

Only use the charger in enclosed spaces ana do not expose it to wet conditions. Water entering a charger in- creases the risk of electric shock.

  •  Keep the charger clean. Dirt poses a risk of electric shock.
  • Always check the charge, including the cable and plug, before use. Stop using the charger if you discover any damage. Do not open the charger yourself, and have it repaired only by Bosch or by an authorised after-sales service centre using only original replacement parts. Damaged chargers, cables and plugs increase the risk of electric shock.
  • Do not operate the charger on an easily ignited surface (e.g. paper, textiles, etc.) or in a flammable environment. There is a risk of fire due to the charger heating up during operation.
  • Do not cover the ventilation slots of the charger. Otherwise, the charger may overheat and no long function properly.
  •  Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of batterypack may create a risk of fire when used with another battery pack.
  •  Incase of damage and improper use of the battery, vapours may also be emitted. Ensure the area is well-ventilated and seek med- ical attention should you experience any adverse effects. The vapours may irritate the respiratory system.
  •  Under abusive conditions, liquid may be ejected from the battery; avoid contact.
    If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or bums.

Products sold in GB only:
Your product is fitted with an BS 1363/A approved electric plug with internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be cut off and an appropriate plug fitted in its place by an authorised customer service agent. The replacement plug should have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible shock hazard and should never be inserted into a mains socket elsewhere.

Product description and specifications

Intended use
The battery charger is intended for charging the rechargeable Bosch Li-ion batteries or PBA 18V POWER FOR ALL system batteries.

Product Features

The numbering of the product features refers to the represent- ation of the charger in the images.
(1) Charging slot
(2) Green battery charge indicator

Technical Data

Battery charger AL 1810 CV AL 18V-20
Protection class ![Icon](https://manuals.plus/wp-
content/uploads/2022/05/Screenshot_3-305.png) / II

Icon/ II
Charging currentA)| 1.0 A| 2.0 A
Battery charging voltage
(automatic voltage detection)| 14.4–18 V| 14.4–18 V
Weight according to EPTA-Procedure 01:2014| 0.17 kg| 0.21 kg

A) Depends on temperature and rechargeable battery type

Charging process

  • Pay attention to the mains voltage. The voltage of the power source must match the voltage specified on the rating plate of the charger.
      Ensure that the charging bay (1) and the battery contacts are free of coarse dirt. Ensure that the battery is fully inserted.
    The charging process begins as soon as the mains plug for the charger is inserted into the mains socket and the battery is inserted into the charging bay (1).
      The charging process is only possible when the temperature of the battery is within the permitted charging temperature range (0-45 °C). Thanks to the intelligent charging process, the state of charge of the battery is automatically detected and then charged up with the optimal charge current depending on battery temperature and voltage. In this way, the battery is treated with care and remains permanently fully charged when it is stored in the battery charger. A significantly reduced operating time after charging indicates that the battery has deteriorated and must be replaced. When the charger is used continuously, or for several consecutive charge cycles without interruption, the charger may heat up. This is, however, harmless and does not indicate that the charger has  a technical defect.

Charging times
The following table displays the approximate timerequired in minutes in order to fully charge the battery, depending on the battery type. The charging time depends on the battery type and the temperature.
AL 1810 CV

Rechargeable battery|
---|---
PBA 18V-1,5 Ah| ≈83
PBA 18V-2,0 Ah| ≈115
PBA 18V-2,5 Ah| ≈136
PBA 18V-3,0 Ah| ≈169
PBA 18V-4,0 Ah| ≈228
PBA 18V-4,0 Ah Power Plus| ≈219
PBA 18V-5,0 Ah| ≈276
PBA 18V-6,0 Ah| ≈335

AL 18V-20 CV

Rechargeable battery|
---|---
PBA 18V-1,5 Ah| ≈49
PBA 18V-2,0 Ah| ≈65
PBA 18V-2,5 Ah| ≈80
PBA 18V-3,0 Ah| ≈99
PBA 18V-4,0 Ah| ≈116
PBA 18V-4,0 Ah Power Plus| ≈123
PBA 18V-5,0 Ah| ≈154
PBA 18V-6,0 Ah| ≈188

corresponds to a full state of charge

What the display elements mean
Flashing light battery charge indicator

The charging process is indicated by the flashing of the battery charge indicator (2).
Continuous light green battery charge indicator
A continuous light on the battery charge indicator (2) signals that the battery is fully charged or that the temperature of the battery is not within the permitted charging temperature range (0– 45 °C), and can therefore not be charged. The battery is charged as soon as the permitted charging temperature range is reached. When there is no battery inserted, the continuous light of the battery charge indicator (2) signals that the mains plug is plugged into the plug socket and that the charger is ready to be used.

Troubleshooting

Battery is not being charged
Battery is not being charged and the battery charge indicator (2) is lit up continuously.
Cause: The charger has identifi ed an internal error.
Corrective measure: Ensure that all batteries are fully inserted. Remove the mains plug and reinsert. If the error occurs again, have the charger checked by an authorised after-sales service centre for power tools.

Cause: Battery temperature is outside of the charging range
Corrective measure: Wait until the battery temperature is back within the permitted charging temperature range (0–45 °C).
Cause: Battery is not correctly inserted.
Corrective measure: Insert the battery into the charger correctly.
Cause: The battery contacts and charging contacts are dirty.
Corrective measure: Clean the battery contacts and charging contacts; e.g. by inserting and removing the battery several times.
Cause: Battery defective
Corrective measure: Replace the battery.
Indicators do not light up
None of the indicators are lighting up, battery will not be charged.
Cause: Plug socket, mains cable or battery charger defective
Corrective measure: Check the mains voltage. If necessary, have the charger checked by an authorised after-sales service centre.
Cause: Mains plug of the battery charger is not (correctly) plugged in
Corrective measure: Plug the mains plug (fully) into the plug socket.

Maintenance and Service

Maintenance and Cleaning
Do not operate charger with a damaged cord or plug. If damaged, have it replaced immediately by a qualifi ed servicemen.

Disposal
Chargers, accessories and packaging should be recycled in an environmentally friendly manner.
Do not dispose of chargers along with household waste.

Only for EU countries:
According to the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment and its implementation into national law, chargers that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.
If disposed incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.
Only for United Kingdom:
According to The Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended), products that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

UK Importer and authorised representative:
ACCO UK Limited
Oxford House Oxford Road
Aylesbury HP21 8SZ
United Kingdom

Isaberg Rapid AB
335 71 Hestra
Sweden