Product Specifications

  • Dimensions
    • PFD 400, PFD 401: 598mm x 638mm x 1203mm
    • PFD 402, PFD 405: 580mm x 620mm x 1185mm
    • PFD 404, PFD 407: 595mm x 635mm x 1200mm
  • Weight
    • PFD 400, PFD 401: 75 kg (66.5 kg without packaging)
    • PFD 402, PFD 405: 78.5 kg (70.5 kg without packaging)
    • PFD 404, PFD 407: 78.5 kg (76.5 kg without packaging)
  • Electrical Connection: AC 230V, 50Hz, 16A – 20A
  • Water Connection: Standard water inlet and outlet sizes
  • Emissions: Noise levels range from 57 dB(A) to 59 dB(A)

Product Usage Instructions

Installation Requirements
Make sure the dishwasher is installed in a suitable environment with proper ventilation and electrical connections.

Electrical Connection
Follow the provided guidelines for connecting the dishwasher to the power supply. Use appropriate plug or hard-wired connection methods.

Water Connection
Connect the dishwasher to a fully vented pipework for water inlet and outlet. Use the correct water inlet hose for cold or hot water connections.

Drainage
Lay the drain hose without any kinks and ensure it is not under pressure or tension. Avoid siphoning effects by maintaining proper drain hose positioning.

Frequently Asked Questions:

  • Q: What should I do if the dishwasher is not draining properly?

    • A: Check the drain hose for any kinks or blockages. Ensure the hose is positioned correctly to avoid siphoning effects during operation.
  • Q: Can I connect the dishwasher to a hot water supply?

    • A: Yes, for models like PFD 400 and PFD 401 U 125 Edition, you can connect the dishwasher to either cold or hot water using the appropriate water inlet hose.

Installation notes

  • For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation and the oper-ating instructions.
  • This installation plan includes the dimensions of the appliance, the technical data and the requirements to be met on site for the installa-tion of the dishwasher.

Installation requirements

  • This dishwasher must only be installed and commissioned by the Miele Customer Service Department, a Miele authorised dealer or a suitably qualified specialist.
  • Installation should only be performed in accordance with valid regulations, relevant standards and health and safety codes.

Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any furniture and fittings in the room must therefore be suitable for purpose.

Protective sheet for built-under appliances
The protective sheet supplied protects the worktop from damage caused by steam escaping when the door is opened. Fit the protective sheet above the door, underneath the worktop.

Electrical connection
All work on the electrical connection must be carried out by the Miele Customer Service Department, an authorised Miele dealer or a qualified electrician.

Plug connection
The dishwasher should be connected to the electricity supply via a socket.

Hard-wired

  • If the dishwasher is hard-wired to the power supply, a power switch capable of disconnecting the dishwasher at all poles must be installed on site. This power switch must have a contact gap of at least 3 mm.
  • The socket and the power switch must be accessible after the appliance has been installed. An electrical safety test must be carried out after installation and after any servicing work.
  • The mains connection cable must be laid protected from the risk of thermal damage.

Residual current device (RCD)

  • For added safety, every machine should be protected by an RCD type A with a trip current of 30 mA.
  • The RCD must be installed so that it is easily accessible.

Equipotential bonding

  • There is a screw connection point for equipotential bonding at the back of the dishwasher.
  • Equipotential bonding should be carried out if possible on site.

Water connection
The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage components of the dishwasher

Water inlet

  • The quality of the incoming water must correspond to the drinking water specification of the country in which the dishwasher is being operated.
  • The dishwasher must be connected to the water supply in strict ac-cordance with current local and national water authority regulations.
  • The dishwasher can be connected to cold or hot water1) supplies. If hot water is not available, the two water inlet hoses (for cold and hot water) must be connected to the cold water supply via a Y-piece.
  • The Y-piece must be connected after the non-return valve.
  • The stopcocks should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.

PFD 400, PFD 401 U 125 Edition
connection to cold or hot water with a water inlet hose

Drain

  • The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, we recommend connecting the hose to a dual-chamber siphon.
  • If the hose is to be fitted directly to the drainage system on site, use the hose clip supplied with the dishwasher.
  • The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened. Otherwise, the drain hose can become blocked.
  • Lay the drain hose so that it does not kink and is not being subjected to pressure or tension.
  • If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a programme can cause the wash cabinet to empty itself of water. In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers. For AU, NZ the drain should be connected in accordance with AS/NZS 3500.2.

Connecting an external dispensing system
Up to two dispensing systems for liquid cleaning agents and rinsing agents can be connected to the back of the dishwasher. Machines with integrated dispensing systems have an external connection for rinsing agents.

Freestanding appliances

  • PFD 400
  • PFD 401 (DOS)
  • PFD 402 (DOS)
  • PFD 404 (DOS)
  • PFD 405 (DOS)
  • PFD 407 (DOS)

The front of the plinth may vary depending on the model

Built-under appliances

PFD 401 U DOS, PFD 402 U (DOS), PFD 405 U (DOS)

The front of the plinth may vary depending on the model

Built-under appliances

PFD 404 U DOS, PFD 407 U DOS

Connections on the back of the appliance

  • PFD 400
  • PFD 401 U 125 Edition
  • PFD 401 (DOS), PFD 402 (DOS),
  • PFD 405 (DOS)

PFD 404 (DOS), PFD 407 (DOS)

  1. Waste water
  2. Electrical connection
  3. Hot water
  4. Cold water and cold water connection for steam condenser
  5. External dispensing, power supply connection
  6. Equipotential bonding
  7. External dispensing, connection for dispenser hose

On-site connections

  1. Waste water
  2. Electrical connection
  3. Hot water
  4. Cold water and cold water connection for steam condenser
  5. External dispensing, power supply connection
  6. Equipotential bonding
  7. External dispensing, connection for dispenser hose

External dispensing

  • Max. delivery head 1.5 m
  • Length of dispenser hose, DOS module to suction lance 1.8 m
  • Length of dispenser hose, back of appliance to DOS module 2.8 m
  • Length of power cable, back of appliance to DOS module 2.8 m

Place the container on the floor next to the dishwasher or in an adjacent cabinet. The container must not be placed on top of or above the dishwasher.

Electrical connection|
---|---
| Standard| Voltage variant *
Voltage| 3N AC 400 V| AC 230 V
Frequency| 50 Hz| 50 Hz
Fuse rating| 3 x 16 A| 16 A
Plug| CEE **| Typ-F
Mains connection cable length| 1.9 m| 1.9 m
Mains connection cable cross-sec- 5 x 2.5 mm2                          3 x 1.5 mm2 tion

Versions for BE, NO|
---|---
| Standard| Voltage variant *
Voltage| 3 AC 230 V| AC 230 V
Frequency| 50 Hz| 50 Hz
Fuse rating| 3 x 20 A| 16 A
Plug| –| Typ F
Mains connection cable length| 1.9 m| 1.9 m
Mains connection cable cross-sec- 4 x 2.5 mm2                          3 x 1.5 mm2 tion

  • Conversion work done by the Miele Customer Service Department
  • CEE plug only for AT, BE, CH, DE, DK, FI, FR, IE, KZ, LU, NL, NO, RU, SE, UA

Water inlet

Max. water temperature cold water 20 °C
Max. water temperature hot water 65 °C
Max. water hardness 10.71 mmol/l
Max. water hardness 60 °dH
Water connection pressure

Cold water

PFD 400, PFD 401, PFD 402, PFD 405:

| ****

40-1000 kPa

PFD 404, PFD 407:| 100–1000 kPa
Hot water| 40-1000 kPa
Flow rate| 7.5 l/min
On-site threaded union (flat seal)| 3/4 inch
Connection hose length| 1.5 m
Connection hose extension *| 1.5 m

  • Optional accessories

Drainage

Max. water temperature|
---|---
PFD 400, PFD 401:| 70 °C
PFD 402:| 80 °C
PFD 404, PFD 405:| 85 °C
PFD 407:| 93 °C
Drain hose length| 1.5 m
Max. drain hose length| 4 m
Max. delivery head| 1 m
Max. transient flow rate| 16 l/min
Hose inner diameter (Ø)| 22 mm
On-site hose sleeve (Ø x length)| 22 x 30 mm

Dispensing
Integrated dispenser pump (DOS)

Dimensions

| Freestanding appli- ance| Built-under appliance
---|---|---
Height| 835 mm| 820 mm
Height adjustment| 60 mm| 60 mm
Width| 598 mm| 598 mm
Depth| |
PFD 400, PFD 401, PFD 402, PFD 405:| 598 mm| 580 mm
PFD 404, PFD 407:| 598 mm| 595 mm
Depth including control panel| |
PFD 400, PFD 401, PFD 402, PFD 405:| 638 mm| 620 mm
PFD 404, PFD 407:| 638 mm| 635 mm
Depth with door open| |
PFD 400, PFD 401, PFD 402, PFD 405:| 1203 mm| 1185 mm
PFD 404, PFD 407:| 1203 mm| 1200 mm
Weights| |
| PFD 400

PFD 401

| PFD 402

PFD 405

| PFD 404

PFD 407

Freestanding appliance (DOS)| 75 kg| 78.5 kg| 78.5 kg
Built-under appliance (DOS)| 66.5 kg| 70.5 kg| 76.5 kg
Max. floor load| 1200 N| 1200 N| 1200 N

Emissions data

| PFD 400, PFD 401,

PFD 402, PFD 405

| PFD 404, PFD 407
---|---|---
Sound power level| 59 dB(A) re 1 pW| 57 dB(A) re 1 pW
Sound pressure level in the workplace| 47 dB(A)| 45 dB(A)
Heat output into the room| 1.44 MJ/h| 1.44 MJ/h

Operating conditions

Min. site access dimensions including transport pallet

Height| | 920 mm|
---|---|---|---
Width| | 670 mm|
Depth| | 740 mm|
Weights including packaging| | |
| PFD 400

PFD 401

| PFD 402

PFD 405

| PFD 404

PFD 407

Freestanding appliance (DOS)| 85 kg| 88.5 kg| 86.5 kg
Built-under appliance (DOS)| 76.5 kg| 80.5 kg| 86.5 kg

  • Manufacturer
    Miele & Cie. KG
    Carl-Miele-Straße 29
    33332 Gütersloh
    Germany

  • Manufacturing site
    Miele & Cie. KG
    Mielestraße 2
    33611 Bielefeld
    Germany
    Internet: www.miele.com/professional

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals