Specifications

  • Measurement Range: 200 – 12,000 mm (7.87 – 472.44 inch)
  • Process Connection: 2 NPT, R 2, G 2
  • Ingress Protection: IP66, IP68, Type 4X, 6
  • Material: PVDF Copolymer, ETFE
  • Electrical Connections: 2 x M20 x 1.5, 1 x 1/2 NPT
  • Certifications: CE, UKCA, KC, RCM, EAC

Product Usage Instructions

Installation

  1. Choose a suitable location for mounting the SITRANS Probe LU240.
  2. Ensure proper electrical connections as per the provided instructions.
  3. Securely attach the transmitter using the appropriate process connection.

Configuration

The SITRANS Probe LU240 comes with easy-to-use quick-start wizards for configuration. Follow these steps.

  1. Access the online configuration portal using the provided Article No.
  2. Follow the step-by-step instructions to set up the desired measurements.

Operation

  1. Ensure the device is powered and properly configured.
  2. Monitor the level, volume, or volume flow measurements as required.

FAQ

Q: What is the maximum range of the SITRANS Probe LU240?

A: The maximum range of the SITRANS Probe LU240 is up to 12 meters (40 feet).

Q: What type of materials can be measured using the SITRANS Probe LU240?

A: The SITRANS Probe LU240 can measure liquids, slurries, and bulk materials.

Q: How can I access the online configuration portal for the SITRANS Probe LU240?

A: You can click on the provided Article No. to access the online configuration portal in the PIA Life Cycle Portal.

Overview

  • SITRANS Probe LU240 ultrasonic level transmitter, ideal for level, volume, and volume flow measurements.
  • It works with liquids, slurries, and bulk materials up to 12 m (40 ft).

Benefits

  • Continuous level measurement up to 12 m (40 ft) range
  • Easy installation and simple startup
  • Programming using 4-button HMI or SIMATIC PDM
  • Communication using HART
  • ETFE or PVDF transducers for chemical compatibility
  • Process Intelligence signal processing
  • Auto False Echo Suppression for fixed obstruction avoidance
  • Low power and current startup
  • Optional Bluetooth configuration and monitoring via SITRANS mobile IQ

Application

  • SITRANS Probe LU240 is ideal for level monitoring in the water and wastewater industry, chemical storage vessels, and small bulk hoppers.
  • The range of SITRANS Probe LU240 is 3, 6, or 12 m (10, 20, or 40 ft).
  • Probe LU240 provides unmatched reliability, using Process Intelligence, Auto False Echo Suppression for fixed obstruction avoidance, and accuracy of 0.15 % of range or 6 mm (0.25 inch) (on 6 m and 12 m models only).
  • SITRANS Probe LU240 offers HART communication on certain models and mA output on all models.
  • SITRANS mobile IQ is a Bluetooth app that provides an intuitive interface to quickly configure, set up, and monitor
  • SITRANS Probe LU240 series (available for Android, Apple, and Windows devices). For more information: http://www.siemens.com/mobileIQ.
  • The transducer on the Probe LU240 is available as ETFE or PVDF to suit the chemical conditions of your application.
  • As well, for applications with varying material and process temperatures, Probe LU240 incorporates an internal temperature sensor to compensate for temperature changes.
  • Key Applications: chemical storage vessels, filter beds, liquid storage vessels

Configuration

Selection and ordering data

Selection and Ordering Data   Order code

CCSAUS, KCs, FM – Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T4, INMETRO, IECEx – Ex ia IIC T4 Ga1) For customs, contact a local salesperson. For more information please visit http://www.automa­ tion.siemens.com/aspa_app.| E34
Spare parts and accessories                                         Article No.

Operating Instructions

All literature is available to download for free, in a range of languages, at http://www.siemens.com/processinstru­ mentation/documentation

|
Accessories

Tag, stainless steel, 12 x 45 mm, one text line (max. 16 characters) Stainless steel FMS200 universal box bracket mounting kit 3″ ASME/DIN Universal mounting adapter, 2″ NPT, ETFE 3″ ASME/DIN Universal mounting adapter, 2″ BSP, ETFE 2″ NPT nylon plastic locknut 2″ BSP nylon plastic locknut Over-voltage protection up to 6 kV (external), M20 x 1.5 Over-voltage protection up to 6 kV (external), ½” NPT Cable Gland Polyamide – General Purpose (‑20 … +60 °C) Bluetooth kit SITRANS LT500 is a versatile, single, and multi-vessel level monitor/controller for virtually any application in a wide range of industries.

|

7ML1930- 1AC

7ML1830- 1BK

7ML1830- 1BT

7ML1830- 1BU

7ML1830- 1DT

7ML1830- 1DQ

7MF7903- 7AB

7MF7903-7AC A5E34457564 A5E50514198 7ML60..-…..-….

Spare Parts Spare lid, clear Spare lid, blind Spare o-ring for lid Spare segmented display, and 4-button HMI|

A5E44267491 A5E44267497 A5E44267501 A5E44809382

  1. Available only with Electrical connections/cable entries option K only.
  2. Available only with order codes E31, E32, E33, and E34.
  3. Order codes E31, E32, E33, and E34 are only available with Type of protection option C.
  4. Available only with Measurement range/wetted parts options D, E, G, and H.
  5. Available only with Measurement range/wetted parts options B and C.
  6. Available only with Type of protection options A and B.

Technical specifications

SITRANS Probe LU240

Mode of operation Measuring principle Typical application| Ultrasonic level measurement in storage vessels and simple process vessels
Inputs

Measuring range

• 3 m (10 ft)

• 6 m (20 ft) model

• 12 m (40 ft) model Frequency

| 0.2 … 3 m (8 inches… 10 ft)

0.2 … 6 m (8 inches… 20 ft)

0.2 … 12 m (8 inches… 40 ft) 54 kHz

Outputs

mA/HART

• Range

• Accuracy

• HART version

• Startup current

• Fail-safe

| 4 … 20 mA

± 0.0096 mA

7

3.6 mA

Programmable as high, low, or hold (loss of echo) per NAMUR NE43

Performance Resolution Accuracy

3 m (10 ft) version

6 m (20 ft), 12 m (40 ft) version

Non-repeatability Blanking distance Update time

Temperature compensationBeam angle

|

≤ 3 mm (0.12 inch)

10 mm (0.39 inch)

• ± the greater of 0.15 % of range or 6 mm (0.25 inch) [valid from 0.25 m (0.82 ft)]

• ± 2 mm (0.08 inch) on ranges 4 m (13 ft) or less

≤ 3 mm (0.12 inch)

0.2 m (0.66 ft)

≤ 4 s

Built-in to compensate for temperature range 10°

Rated operating conditions

Ambient conditions

• Location

• Ambient temperature

• Relative humidity/ingress protection

• Installation category

• Pollution degree Medium conditions

• Temperature at flange or threads

• Pressure (vessel) Display

| Indoor/outdoor

• Storage: -40 … +85 °C (-40 … +185 °F)

• Operating: -40 … +80 °C (-40 … +176 °F)

Suitable for outdoor I 4

-40 … +85 °C (-40 … +185 °F)

0.5 bar g (7.25 psi g)

-20 … +80 °C (-4 … +176 °F)

Design

Material (enclosure) Degree of protection Weight

Cable inlet

Material (transducer)

|

PBT (Polybutylene Terephthalate) Type 4X, Type 6, IP66, IP68

0.93 kg (2.1 lb)

2 x M20 x 1.5 cable gland or 1 x ½” NPT thread

ETFE (Ethylene Tetrafluoroethylene) or PVDF (Polyvinylidene Fluoride) Buna-N seal

Process connection

Threaded connection

Flange connection

| 2″ NPT [(Taper), ASME B1.20.1]

R 2″ [(BSPT), EN 10226]

or

G 2″ [(BSPP), EN ISO 228-1]

3 inch (80 mm) universal flange

SITRANS Probe LU240

Other connection| FMS 200 mounting bracket (see FMS mounting bracket product page for more information) or customer-supplied mount.
Display and Controls

Interface

Configuration Memory

| Local: LCD

Remote: Available via HART or Bluetooth 4-button HMI

Non-volatile EEPROM, no battery required

Power supply

4 … 20 mA/HART

| 10.5 … 30 V DC
Certificates and Approvals|
General| FM, CCSAUS, CE, UKCA, RCM, EAC, KC, VLAREM II
Hazardous|
• Intrinsically Safe|
– Europe| ATEX II 1G Ex ia IIC T4 Ga
– UK| UKEX II 1G Ex ia IIC T4 Ga
– International| IECEx SIR 18.0013X Ex ia IIC T4 Ga
– USA/Canada| FM/CCSAUS Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III T4
– Brazil| INMETRO Ex ia IIC T4 Ga
– China| NEPSI Ex ia IIC T4 Ga
– South Africa| SABS Ex ia IIC Tx Ga
– Russia| EAC Ex 1G Ex ia IIC T4 Ga
– Korea| KCs Ex ia IIC T4
• Non-incendive|
– USA| FM, Class I, Div. 2, Groups A, B, C, D Tx
Metrological| MCERTS, CPA, Kazakhstan patterns approval
Radio (Bluetooth)| USA, Canada, EU, China

Options

SITRANS Probe LU240 optional flange adapter, dimensions in mm (inch)

SITRANS Probe LU240 with optional FMS 200 universal box bracket

Dimensional drawings

SITRANS Probe LU240 with optional Bluetooth adapter, dimensions in mm (inch)

Circuit diagrams

SITRANS Probe LU240 connections

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)