Danfoss EVRF 3-W Unloader Ange Valve Type
Product Information
Specifications:
- Product Model : 032R9510
- Brand: Danfoss
- Model: A32F915.10
- Type: Unloader flange valve Type EVRF 3-W (NC)
- Max. Working Pressure (PS/MWP): 45.2 bar (405 psig)
- Max. Operating Differential Pressure (MOPD): 25 bar (360 psi)
Product Usage Instructions
Installation Guide:
- Identify the unloader flange valve Type EVRF 3-W (NC) labeled as 032R9510.
- Ensure that the maximum working pressure and operating differential pressure are within the specified limits.
- Connect port In to the appropriate input source and port A to the desired output destination.
- Make sure the coil is energized for the valve to operate as intended.
Usage Steps:
- To open port A, energize the coil connected to the valve.
- To close port A and open port In, de-energize the coil.
- Regularly check for leaks or pressure issues during operation.
FAQ
-
What should I do if the valve is leaking?
If you notice leakage, first check the connections for any loose fittings. If the issue persists, contact customer support for further assistance. -
Can I use this valve for high-pressure systems?
The valve is designed for a maximum working pressure of 45.2 bar (405 psig), so ensure your system does not exceed this limit to prevent damage or malfunction.
SPECIFICATION
- Ambient temperature:
- Min. : tmin. = -40 °C (-40 °F)
- Max. : tmax. = 80 °C (175 °F)
- Media temperature:
- Min. : tmin. = -40 °C (-40 °F)
- Max. : tmax. = 130 °C (265 °F)
- Max. working pressure (PS / MWP): 45.2 bar (405 psig)
- Max. operating di. pressure (MOPD): 25 bar (360 psi)
PRODUCT OVERVIEW
- NC = Normally closed.
- With coil de-energized, port “In“ is closed and port “A” is open to “Out“.