PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

BEFORE YOU BEGIN

WARNING!

Installation, trouble shooting, and replacement of parts are to be performed only by authorized service technicians.

Electrical Requirements:

  • The motor amperage and voltage ratings must be checked for compatibility to supply voltage prior to final electrical connection. Please refer to the motor’s nameplate label.
  • Wiring must conform to local, state, and national codes.

Tools / Materials Needed:(Not Included)

  • Mounting Fasteners (8)
  • Sealant or Caulk
  • Regular Screwdriver Set

UNPACKING

Contents

  • Shutter Mounted Exhaust Fan
  • Fan control (ILG8SFST)
  • Owner’s Manual

Inspect:

  • After unpacking the fan, carefully inspect for any damage that may have occurred during transit. Check for loose, missing, or damaged parts.
  • Check all bolts, screws, set screws, etc. for looseness that may have occurred during transit. Tighten as needed. Rotate the propeller by hand to ensure it turns freely.
  • See General Safety Instructions on page 3, and Cautions and Warnings as shown.

GENERAL SAFETY INSTRUCTIONS

Fans are UL/CUL Listed, Standard 507.

  1. Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan.
  2. Always disconnect, lock out, and tag out the power source before installing or servicing. Failure to disconnect the power source can result in fire, shock, or serious injury.
  3. The motor will restart without warning after thermal protector trips. Do not touch the operating motor; it may be hot enough to cause injury.
  4. Do not place body parts or objects in fan or motor openings while the motor is connected to the power source.
  5. All electrical connections should be made by a qualified electrician.
  6. These utility exhaust fans are for general-purpose exhaust applications only. Do not use these exhaust fans in an area where corrosive or explosive materials may be found.
  7. Follow all local and state/provincial electrical and safety codes in the United States and Canada, as well as the National Electrical Code (NEC) ahe Occupational Safety and Health Act (OSHA) in the United States, and the Canadian Electric Code (CEC) in Canada.
  8. Always disconnect the power source before working on or near a motor or its connected load.
  9. Protect the power cable from coming in contact with sharp objects.
  10. Do not kink or create tight bends in the power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.
  11. Make certain that the power source conforms to the requirements of your specific exhaust fan model. The fan frame and motor must be electrically grounded to a suitable electrical ground, such as a grounded water pipe or ground wire system.
  12. To reduce the risk of injury to persons, please observe the following: In the United States, OSHA-compliant guards are required when the fan is installed within 7 feet of the floor or working level. In Canada, CSA-compliant guards are required when the fan is installed below 2.5 meters (8.2 feet) above the floor or grade level.
  13. Suitable for use with solid-state speed controls.

INSTAILNLSATTAIOLLNAITNISOTNRIUNCSTTIROUN

  1. The unit should be securely mounted in a rigid framework.
    • NOTE: Allowing the fan frame to flex or move will result in excess vibrations, which may cause possible premature motor, propeller, or shutter failure.
  2. Install any auxiliary components such as thermostats, switches, or speed controls.
  3. Connect power to the motor using an approved wiring method. Refer to the following wiring diagram.
    • Fan frame and motor must be securely and adequately grounded to a suitable electrical ground, such as a ground water pipe or ground wiring system.

Wiring Diagram

Installation Diagram

GENERAL SPECIFICATIONS

Power source 115V, 60Hz
Mounting Position Vertical
Frame Material Galvanized Steel
Shutter Blade Material Aluminum Alloy
Propeller Material Aluminum Alloy and Galvanized Steel
Agency Compliance UL/CUL 507

Dimensions (Inches)

Product Specifications

Model| ILG8SF12V-1
Voltage| 115V
Frequency| 60Hz
Wattage| 65W
AMPS| 0.6A
RPM| 1650
CFM| 960
Suggested wall opening (Sq)| ****

13″

Product Specifications

Model| ILG8SF10V-1
Voltage| 115V
Frequency| 60Hz
Wattage| 65W
AMPS| 0.6A
RPM| 1650
CFM| 820
Suggested wall opening (Sq)| ****

10 1/2″

OPERATING INSTRUCTIONS

  1. Keep the area free of objects that could impede air flow on both the intake and exhaust sides of fan.
  2. For proper exhaust operation, a window, door, or louver should be opened for fresh air intake on the opposite side of the area to be ventilated.
  3. Turn the fan ON; the shutter will open automatically. When the unit is turned OFF, the shutter will close.
  4. Speed-controllable units are designed to operate at a minimum of fifty percent line voltage.

MAINTAINANCE

  1. Disconnect power source before servicing.
  2. Periodically clean off accumulated dirt from the propeller, guard, motor, and shutter.
    • Do not depend on any switch as the sole means of disconnecting power when installing or servicing. If the power disconnect is not visible, utilize OSHA Lockout/Tag out procedure.
    • Failure to do so may result in fatal electrical shock.  Employ proper lock-out/tag-out procedures when performing maintenance.

TROUBLESHOOTING

Symptom Possible Cause(s) Solution




Excessive noise

| Dry motor bearings| Re-lubricate motor bearings as per instructions or replace motor.
Loose propeller| Tighten set screws on propeller hub.
Bent or damaged propeller| Replace propeller
Loose guard assembly or motor fasteners.| Tighten as required to 15- 20 lbs. per inch.
Fan inoperative| Blown fuse or open circuit breaker| Replace fuse or reset circuit breaker
Defective motor| Replace motor
Switch in OFF position| Turn switch ON






Insufficient air flow

| Blocked intake or exhaust opening| Clear intake and exhaust openings of any obstructions.

Clean motor, guard, propeller, and shutter assembly. Increase the opening of the fresh air intake.

Low voltage| Check electrical wiring.
Speed control set too low| Increase speed with controller

Warranty Information

This product comes with a 1-YEAR LIMITED COMPONENT WARRANTY. If your unit does not appear to be working properly, please contact our service center by calling 1-800-317-1688. Prior to your call, we encourage you to visit our service-related website www.ilivingusa.com for troubleshooting tips and service instructions if needed. If you wish to make a warranty claim, please contact the Manufacturer directly at 1-800-317-1688. Please have the Model Number and the Serial Number of the Product ready and the complete Sales Invoice from an authorized seller, showing the date of purchase, condition upon purchase and full details of the Product. Our Customer Service Team will advise you of the process involved in making a claim. Any claim under the Limited Warranty is subject to notify us of the alleged defect within a reasonable time of it coming to your attention, in any case, by no later than the expiry of the Warranty Period.

Warranty Information
Register your product at our website: Or visit iLivingUSA.com/register- product

Feedback
Love it? Help us make the product more for you.

Let us know with a customer review. Please visit: https://www.amazon.com/review/review-your-purchases# At iLiving USA, we are committed to bringing top quality products to our customers.

iLIVING USA 860 Mahler Road, Burlingame, CA 94010 Tel: 1-800-317-1688

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

iLIVING User Manuals

Related Manuals