iLIVING ILG8SF12V-DC Wall Mounted Shutter Exhaust Fan Owner’s Manual

May 15, 2024
iLIVING

iLIVING ILG8SF12V-DC Wall Mounted Shutter Exhaust Fan

iLIVING-ILG8SF12V-DC-Wall-Mounted-Shutter-Exhaust-Fan-
PRODUCT

Specifications:

  • Models: ILG8SF12V-DC, ILG8SF14V-DC, ILG8SF16V-DC
  • For indoor use only
  • Suitable for commercial or industrial use
  • Electrical Requirements: 120V, 60Hz

Product Usage Instructions

Important Safety Instructions:

  1. Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan.
  2. Always disconnect, lockout, and tag out the power source before installing or servicing.
  3. Do not place body parts or objects in fan or motor openings while the motor is connected to the power source.
  4. CAUTION – For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
  5. Follow all local and state/provincial electrical and safety codes.
  6. Always disconnect the power source before working on or near a motor or its connected load.
  7. Protect the power cable from sharp objects and avoid contact with oil, grease, hot surfaces, or chemicals.

Installation Instructions:

  1. The unit should be securely mounted in a rigid framework to prevent excess vibrations.
  2. Fan frame and motor must be securely grounded to a suitable electrical ground.
  3. Install the shutter fan through 8 holes with screws.
  4. Please ensure the space has a gap for enough air to get into the space.
  5. Install the control box to the wall with screws and connect the USB cord.
  6. Plug the power cord into a grounded wall outlet (120V, 60Hz).

Air Flow: Make sure there is free space of at least 100mm above the upper edges of the corner for proper airflow.

FAQ: Q: Can this fan be used outdoors?
A: No, this fan is designed for indoor use only.

Q: What type of electrical requirements does this fan have?
A: The fan requires 120V, 60Hz electrical input.

Models: ILG8SF12V-DC, ILG8SF14V-DC, ILG8SF16V-DC

PLEASE READ AND SAVE THESE INSTRUCTIONS
PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

BEFORE YOU BEGIN

Installation, troubleshooting, and replacement of parts are to be performed only by authorized service technicians.

Electrical Requirements:
The motor amperage and voltage ratings must be checked for compatibility to supply voltage before the final electrical connection. Please refer to the motor’s nameplate label.

Tools / Materials Needed(Not Included):

  • Mounting Fasteners (8)
  • Sealant or Caulk
  • Regular Screwdriver Set

UNPACKING

Contents:

  • Shutter Mounted Exhaust Fan & Control Box
  • Owner’s Manual

Inspect:

  • After unpacking fan, carefully inspect for any damage that may have occurred during transit. Check for loose, missing, or damaged parts.
  • Check all bolts, screws, set screws, etc. for looseness that may have occurred during transit. Tighten as needed. Rotate the propeller by hand to ensure it turns freely.
  • See Important Safety Instructions on page 2, and Cautions and Warnings as shown.

IMPORTANT SAFETY INSTRUCTIONS

  1. Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan.
  2. Always disconnect, lock-out, and tag-out power source before installing or servicing. Failure to disconnect power source can result in fire, shock, or serious injury.
  3. Do not place body parts or objects in fan or motor openings while motor is connected to the power source.
  4. CAUTION – For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
  5. Follow all local and state/provincial electrical and safety codes in the United States and Canada, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA) in the United States, and the Canadian Electric Code (CEC) in Canada.
  6. Always disconnect power source before working on or near a motor or its connected load.
  7. Protect the power cable from coming in contact with sharp objects.
  8. Do not kink or create tight bends in the power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.
  9. Make certain that the power source conforms to the requirements of your specific exhaust fan model. The fan frame and motor must be electrically grounded to a suitable electrical ground, such as a grounded water pipe or ground wire system.
  10. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
  11. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and similar danger locations.
  12. The discharge air is to be directed to the building exterior.
  13. Not for use in kitchens.
  14. Do not install in a cooking area.

INSTALL IN INTERIOR WALL

  • CAUTION – MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2.5 m (8.2 ft) ABOVE FLOOR OR GRADELEVEL.
  • CAUTION – HOT SURFACE. AVOID CONTACT.
  • WARNING – For indoor use only.
  • WARNING – To reduce the risk of electric shock, do not expose to water or rain.
  • WARNING Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

Suitable for commercial or industrial use.

INSTALLATION INSTRUCTIONS

  1. The unit should be only securely mounted in a rigid framework.
    NOTE : Allowing the fan frame to flex or move will result in excess vibrations, which may cause possible premature motor, propeller, or shutter failure.
    Fan frame and motor must be securely and adequately grounded to a suitable electrical ground, such as a ground water pipe or ground wiring system.

  2. Install the shutter fan through 8 holes with screws. (Screws are not included.)iLIVING-ILG8SF12V-DC-Wall-Mounted-Shutter-Exhaust-Fan-FIG- \(1\)

  3. Please ensure the space has a gap for enough air to get into the space. The fan installed on free space of at least 100mm above the upper edgesof the corner.

  4. Install the control box to the wall with 2 screws.(Screws are not included.)

  5. Plug the power cord into a grounded wall outlet(120V, 60Hz). Plug the USB cord to connect with the control box.iLIVING-ILG8SF12V-DC-Wall-Mounted-Shutter-Exhaust-Fan-FIG- \(3\)

SPECIFICATIONS

  • Power source 120V, 60Hz
  • Mounting Position Vertical
  • Frame Material Galvanized Steel
  • Shutter Blade Material Aluminum Alloy
  • Propeller Material Aluminum Alloy and Galvanized Steel
  • Agency Compliance CSA C22.2 No. 113 & UL 507

Dimensions

iLIVING-ILG8SF12V-DC-Wall-Mounted-Shutter-Exhaust-Fan-FIG-
\(4\)


MODEL

| Prop. Dia.| ****

A

| ****

B

| ****

C

| ****

D

| ****

E

| ****

N

| ****

G

| ****

F

| ****

O

| ****

H

| ****

J

| ****

I

| Suggested wall opening (Sq)
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
ILG8SF12V- DC| 12″| 15″| 15″| 5 3/4″| 2″| 6 5/32″| 13 5/8″| 12 1/8″| 12 1/8″| 8″| 3 1/2″| 9/32″| 1/2″| 13″
ILG8SF14V- DC| 14″| 17″| 17″| 5 3/4″| 2″| 6 5/16″| 15 14/16″| 14 1/4″| 14 1/4″| 10 3/16″| 3 17/32″| 9/32″| 1/2″| 15″
ILG8SF16V- DC| 16″| 18 29/32″| 18 29/32″| 5 3/4″| 2″| 7 7/8″| 17 3/4″| 16″| 16″| 11 29/32″| 3 17/32″| 9/32″| 1/2″| 17″

Performance

Model ILG8SF12V-DC ILG8SF14V-DC ILG8SF16V-DC
Voltage 120 120 120
Frequency 60 60 60
Wattage 45 60 70
AMPS 0.65 0.85 0.9
PRM 1600 1600 1600
CFM 960 1200 1736

OPERATING INSTRUCTIONS

  1. Keep the area free of objects that could impede airflow on both the intake and exhaust side of the fan.
  2. For proper exhaust operation, a window, door, or louver should be opened for fresh air intake on the opposite side of the area to be ventilated.
  3. Connect the power plug to any standard 120-volt AC outlet.
  4. Control Box

iLIVING-ILG8SF12V-DC-Wall-Mounted-Shutter-Exhaust-Fan-FIG-
\(5\)

  • A. LED display
  • B. Power ON/OFF & Mode button
  • C. Increase button
  • D. Decrease button
  • E. RH button

About the Power ON/OFF & Mode button

  • To turn on the shutter fan, press M/ the button; the LED display will turn on and the shutter fan will wait in AUTO Mode.
  • Press M/ the button to toggle between the different modes:
  • AUTO / Manual / TIMER / Power OFF.
  • Press M/ the button for 3 seconds can also Power off the fan.

ATUO Mode

  • AUTO mode is a computerized mode to optimize energy efficiency. It will programmatically select fan speed between 12 and 8 to cool down the room to the desired temperature and humidity in the most effective way.
  • When the room temperature drops to ≤ the set temperature -2~3 degree F, the fan stops running. When the room temperature rises to ≥ the set temperature +2~3 degree F, the fan will turn on. As the same with humidity.
  • When the room humidity drops to ≤ the set humidity -2~3 %, the fan stops running. When the room humidity rises to ≥ the set humidity +2~3 %, the fan will turn on.
  • AUTO mode is the environmental friendly operating mode.

Setting the room temperature

At AUTO mode, it will display the factory default setting temperature 80°F, and humidity 70%. You can press the + or – button to set your desired temperature between 50°F-99°F.

Setting the Humidity
To set the humidity, press the button. The factory default setting is 70%, you can press the + or – button to set your desired humidity between 30%- 90%.

MANUAL Mode

The manual mode is autonomous mode, and the fan will stop detecting the temperature and keep on blowing.
In manual mode, press the + or – button can increase or decrease the fan speed. The fan speed range 0 to 12.

TIMER Mode
Press the TIMER button to set the Timer. The default value is 3 hours.The timer can be set from 0 to 24 hours. The fan will shut OFF automatically when the set time is reached.

To turn the timer OFF,pressing the “–” button to set the time to 0. The timer feature will turn off when the LED stops flashing.
In timer mode, press the + or – button can increase or decrease the setting time.

Display the set temperature
The display shows the room temperature all the time, press and hold M/ the button and then press the button. The set temperature will display for 30 seconds. It will return to room temperature after 30 seconds.

Display Celsius
To display Celsius, press and hold the button and then press the button for 2 seconds. Press and hold the MODE button for 2 seconds again to change back to Fahrenheit.

Memory function
This shutter fan has a memory function, when you turn off by pressing the button, in case of power outages. If the fan operates at maximum speed when it shuts off in a power outage, it will resume its operation at the maximum speed when the power comes back on. The memory function registers the last operating speed.

MAINTAINANCE

  1. Unplug the appliance before servicing.
  2. Periodically clean off accumulated dirt from the propeller, guard, motor, and shutter.

Do not depend on any switch as the sole means of disconnecting power when installing or servicing. If power disconnect is not visible, utilize OSHA Lockout/Tag out procedure.
Failure to do so may result in fatal electrical shock.
Employ proper lock-out/tag-out procedures when performing maintenance.

TROUBLESHOOTING

Symptom Possible Cause(s) Solution



Excessive noise

| Loose propeller| Tighten set screws on propeller hub.
Bent or damaged propeller| Replace propeller
Loose guard assembly or motor fasteners.| Tighten as required to 15- 20 lbs. per inch.
Fan inoperative| Blown fuse or open circuit breaker| Replace fuse or reset circuit breaker
Defective motor| Replace motor
Switch in OFF position| Turn switch ON






Insufficient air flow

| Blocked intake or exhaust opening| Clear intake and exhaust openings of any obstructions.

Clean motor, guard, propeller, and shutter assembly. Increase the

opening of the fresh air intake.

Low voltage| Check electrical wiring.
Speed control set too low| Increase speed with controller

Warranty Information

This product comes with a 1-YEAR LIMITED COMPONENT WARRANTY. If your unit does not appear to be working properly, please contact our service center by calling 1-800-317-1688. Before your call, we encourage you to visit our service-related website www.ilivingusa.com for troubleshooting tips and service instructions if needed.

Register your product at our website

Or visit iLivingUSA.com/register-product

Feedback
Love it? Help us make the product more for you.

Let us know with a customer review.
Please visit: https://www.amazon.com/review/review-your-purchases#
At iLiving USA, we are committed to bringing top-quality products to our customers.

iLIVING USA 860 Mahler Road, Burlingame, CA 94010
Tel: 1-800-317-1688
Email: service@ilivingusa.com

Like us on Facebook: https://www.facebook.com/ilivingusa/
Follow us on Twitter: @iLIVINGUSA
Check out our website: www.ilivingusa.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

iLIVING User Manuals

Related Manuals