Specifications
- Product: 60 x 30 alcove Heated BubbleMassageTM air bath, right drain
- Model: K-1947-GHRF
- Dimensions: 60″ x 30″
- Water Depth: 15-1/8″
- Water Capacity: 57 gal (215.8 L)
- Electrical Requirements: Blower – 120 V, 10 A, 60 Hz; Heater – 120 V, 5 A, 60 Hz
Product Usage Instructions
Features
- 120 airjets release thousands of heated bubbles that surround and support the body in a warm massage
- Automatic and manual purge cycles remove residual water from air channels after use
- Variable-speed blower lets you adjust massage intensity to 18 levels
- Comfort Depth® design offers a convenient 19″ step-over height while retaining the same depth as a standard 21″ bath
- Integral lumbar support
- Slotted overflow allows for deep soaking
- Integral flange helps prevent water from seeping behind wall and simplifies alcove installation
- Textured bottom surface
- Coordinates with other products in the Archer collection
- Built-in 600W BubbleMassage™ heater warms humidified air before it enters the bath
- Automatic and manual purge cycles remove residual water from air channels after use
Material
- Acrylic
Technology
- The auto-shutoff timer on the blower allows users to enjoy the Heated BubbleMassage™ experience for 60 minutes before turning off
- User interface: electronic keypad control
Installation
- Right drain
- Alcove
Required Products/Accessories
- K-7271 Brass Slotted Overflow Bath Drain
- K-7272 PVC Slotted Overflow Bath Drain
Recommended Products/Accessories
- K-1446 Remote Installation Kit
- K-23726 Drain treatment
- K-23732 Tub & shower cleaner
- K-31797 Slotted overflow bath drain kit
- K-31795 Slotted overflow above-the-floor bath drain kit
Codes/Standards
- ASME A112.19.7/CSA B45.10
- CSA B45.5/IAPMO Z124
- ASTM E162
- ASTM E662
- UL 1795
- CSA C22.2 No. 218.2
- ADA
- ICC/ANSI A117.1
- IAPMO Certification
- UL Listed
KOHLER® Plastic Baths and Shower Bases Lifetime Limited WarrantyKOHLER®
Hydrotherapy Components Five-Year Limited Warranty
See website for detailed warranty information.
Available Colors/Finishes
Color tiles intended for reference only
Dimension
Installation
Before installation, ensure you have the required products/accessories such as
K-7271 or K-7272 Slotted Overflow Bath Drain. Follow the installation
instructions provided with the product. Two dedicated circuits are required
for electrical connections.
Required Electrical Service
Two dedicated circuits required, protected with Class A GroundFault Circuit-
Interrupter (GFCI). Outside North America, this device may be known as a
Residual Current Device (RCD).
- Blower: 120 V, 15 A, 60 Hz
- Heater: 120 V, 15 A, 60 Hz
Technical Information
All product dimensions are nominal.
- Drain location: Right
- Basin area, bottom: 45-1/8″ x 19-11/16″ (1146 mm x 500 mm)
- Basin area, top : 52-1/8″ x 22-1/16″ (1324 mm x 560 mm)
- Weight: 110 lbs (49.9 kg)
- Minimum floor load: 48 lbs/ft² (234.4 kg/m²)
- Water depth: 15-1/8″ (384 mm)
- Water capacity: 57 gal (215.8 L)
- Electrical component rating:
- Blower: 120 V, 10 A, 60 Hz
- Heater: 120 V, 5 A, 60 Hz
- Minimum flat for door: 2-9/16″ (65 mm)
Notes
Measure your actual product for rough-in details. Install this product
according to the installation instructions. The hot water supply should be 70%
of the capacity of the bath or greater. Installations will vary. Remote blower
installation kit is available for relocating the blower. Provide access for
servicing the blower. Do not relocate or alter the PVC tee or coiled flexible
tubing connected to the blower. Follow the blower relocation instructions
exactly. ADA compliant when installed to the specific requirements of these
regulations.
Maintenance
For optimal performance, use recommended products/accessories like Drain
treatment, Tub & shower cleaner, and Slotted overflow bath drain kit.
Regularly clean the bath to prevent build-up.
Usage
Fill the bath with water to the desired level. Turn on the BubbleMassageTM
feature for a relaxing experience. Ensure the hot water supply meets the
recommended capacity. Do not alter the PVC tee or tubing connected to the
blower.
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product
specifications.
For the most current Specification Sheet, go to
www.kohler.com USA or
www.kohler.ca Canada
2-28-2024 21:45 – US
FAQ
Is this product ADA compliant?
Yes, this product is ADA compliant when installed according to specific
regulations.
What electrical service is required?
The blower requires 120 V, 10 A, 60 Hz, and the heater requires 120 V, 5 A, 60
Hz.
Can I relocate the blower?
A remote blower installation kit is available for relocating the blower.
Follow relocation instructions carefully.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>